Alternator Technical Data - LSAM 47.2 L9 519KVA 400V 50Hz IP23 H-H Baja Capacidad Corto
Alternator Technical Data - LSAM 47.2 L9 519KVA 400V 50Hz IP23 H-H Baja Capacidad Corto
Main data C 1
Generator type: LSA 47.2 L9 / 4p 1
Power: 519,0 kVA 415,2 kWe 437,6 kWm 1
Voltage: 400 V Star serial 1
Rated voltage range: +5/-5% 1
Power factor - Lagging: 0,8 1
Frequency: 50 Hz 1
Speed: 1500 rpm 1
Nominal current: 749 A 1
Winding type: p2/3 1
Classes (Insulation / Temperature Rise): H/H 1
Ambient Temperature: 45 °C 1
Altitude: 1000 m 1
-
Installation Quantity 1 1
Client: Finanzauto 1
Prime mover: Reciprocating engine 1
Manufacturer: - 1
Type: - 1
Duty: Base Rating 1
Industry: Marine 1
-
Mechanical Construction IM1201 1
Type of construction: Single bearing 1
Mounting arrangement: Horizontal Axis 1
Direction of rotation: Clockwise (seen when facing the drive end - DE) 1
Bearing type: Anti-friction 1
Bearing Lubrication: Regreasable 1
Bearing insulation: Not insulated 1
Flector type: SAE 18 1
Balancing - Class (ISO 1940/1): To be defined - G2,5 (std) 1
Flange: SAE 0 1
Shaft height: 355 mm 1
Width: 710 mm 1
-
Additional specificities 1
Stabilized Runaway speed: 1800 rpm - 2 min. 1
-
Cooling Method IC01 1
Degree of protection: IP23 1
Coolant: Air / Temperature: 45 °C 1
Air quality: Clean 1
Ventilation (internal): Self-ventilated 1
Filters: Without 1
Ducting for air inlet: No 1
Ducting for air outlet: No 1
-
Connection, Excitation & Regulation 1
Parallel operation: Between alternators (1F) - 1x //CT 1
Excitation: Self-excited - Brushless - Type: AREP 1
Sustained 3-phase Isc: > 3 x FLC for 10s. 1
AVR type: R450 1
AVR location: In terminal box 1
Alternator Voltage sensing: In terminal box 1
-
Terminal box
Power connection: 12 connectors (reconnectable) 1
Main Terminal box location: 1 terminal box on the top 1
Line side outlet: Left hand side (seen when facing the drive end - D) 1
Gland plate: Standard - Cable gland plate not drilled 1
- 1
-
Protection and measurement accessories 1
1
Temperature detection 1
1
Anti-condensation heating 1
Voltage: 230 V - 1Ph / Power: 250 W 1
-
-
Various items
Paint: C3M-P - Polyurethane - CAT 1
Documentation: PDF manual 1
Documentation Language: Spanish 1
-
Controls
-
Main data: C
Power: 519,0 kVA 415,2 kWe 437,6 kWm 1
Voltage: 400 V Frequency: 50 Hz 1
Rated voltage range: +5% / -5% Speed: 1500 rpm 1
Power factor - Lagging: 0,8 1
Nominal current: 749 A Phases 3
Insulation / Temperature rise: H/H Connexion Star serial 1
Cooling: IC01 Winding type: p2/3 1
Winding: 6 - 12 Wires 1
Ambient Temperature: 45 °C 1
Altitude: 1000 m Overspeed (rpm) 1800 1
Duty: Base Rating Total Harmonic Distortion (THD) < 5% 1
Resistances (%)
Ra 3,5 Armature resistance R0 17,8 Zero sequence resistance 1
X/R X/R ratio (without unit) R2 3,3 Negative sequence resistance
rating is provided for the specified temperature rise, by resistance measurement according to IEC60034-1
According to: I.E.C. 60034.1 - 60034.2 - NEMA MG 1-32
Products and materials shown in this catalogue may, at any time, be modified in order to follow the latest technological developments,
#¡REF!
Umax + 5% 420 V
Capability Curve Un 400 V
Umin - 5% 380 V
0,8
PF -0,6 PF 0,6
0,6
PF -0,5 PF 0,5
PF -0,4 PF 0,4
0,4
PF -0,3 PF 0,3
PF -0,1 PF 0,1
0
-1,0 -0,8 -0,6 -0,4 -0,2 0,0 0,2 0,4 0,6 0,8 1,0
kVAr // rated
kVAr ratedkVA
kVA
PF 1 PF 0,8
97,0
96,41 96,39 96,33
96,5
95,96
Efficiency - Rendement en %
96,0
95,5
95,0 95,17
95,00
94,87
94,5 94,70
94,0
93,64
93,5
93,0 92,98
92,5
25 50 75 100 125
Isc ( Short circuit current per rated current - Courant de court circuit / In )
Symmetrical Phase to neutral short circuit
12 Symmetrical two phase short circuit
Symmetrical three phase short circuit
Thermal limit curve
court circuit aux bornes de l'alternateur
10
short circuit at generator terminals -
0
0,001 0,01 0,1 1 10 100
Time - Temps (second.)
Isc ( Short circuit current per rated current - Courant de court circuit / In )
Symmetrical three phase short circuit (rms)
25
Asymmetrical three phase short circuit (peak)
20
court circuit aux bornes
15
10
0
0,001 0,01 0,1 1 10 100
Time - Temps (second.)
5%
10%
15%
20%
25%
PF = 0,8 PF = 0,6 PF = 0,3 PF = 0,6 100%
25%
20%
15%
10%
5%
0%
0 200 400 600 800 1 000 1 200 1 400
PF = 0,8 100%
Stator current
(per rated current)
6
5,5
4,5
3,5
2,5
1,5
1
1 10 100 1000 10000
Maximum duration - durée maximum (second.)
2 50 C
B
1 25
A
0 0
1 10 100 1000 10000 0 1 2 3 4 5 6 7 8 9 10 11 12
Maximum duration of fault - Maximum duration of fault -
Durée max. du defaut (second.) Durée max. du defaut (second.)