You are on page 1of 144

6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

FINAL EXAMINATION (Subject Area C) – 40%


Due
7 Jun at 20:00
Points
153
Questions
154
Available
7 Jun at 16:30 - 7 Jun at 20:00
about 4 hours
Time limit
180 Minutes

Instructions
Carefully follow directions.  This is a closed book, closed notes examination.  Browsing the internet while
using canvas can be detected.  DO NOT CHEAT.

Attempt history
Attempt Time Score
LATEST Attempt 1
155 minutes 90 out of 153
*

* Some questions not yet graded

Score for this quiz:


90 out of 153
*
Submitted 7 Jun at 19:09
This attempt took 155 minutes.

Question 1 1
/ 1 pts

Where should be the location of the main drainage, electrical service


entrance, and main sewer line and water service pipe?

 
At the easement

 
At the setback

 
Along the property line

Correct!  
Within the property line

https://tip.instructure.com/courses/29639/quizzes/428764 1/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

Question 2 1
/ 1 pts

. For a Call Center, which of the following spaces will you recommend to
be adjacent to each other?

 
Maintenance room-chase-fire exit stairs-office

Correct!  
Elevator-electrical room-shaft-ups room

 
Main reception-gm office-training room-interview room

 
Activity area-sleeping room-pantry-toilets

Question 3 1
/ 1 pts

Remedial work done on any damaged or deteriorated portion/s of


building/structure to restore to its original condition.

 
Conversion

 
Alteration

 
Renovation

Correct!  
Repair

Question 4 1
/ 1 pts

https://tip.instructure.com/courses/29639/quizzes/428764 2/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

What wall finish is inappropriate if the objective is to lessen sound


reverberation in a music hall?

 
Patterned plywood

 
) Low relief

Correct!  
Piano finished laminate

 
Flamed granite

Question 5 1
/ 1 pts

              

Any physical change made on buildings/structures to increase the value,


quality, and/or to improve the aesthetic.

 
Alteration

Correct!  
Renovation

 
Addition

 
Conversion

Question 6 1
/ 1 pts

https://tip.instructure.com/courses/29639/quizzes/428764 3/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

It means the degree to which a material can withstand fire as determined


by generally recognized and accepted testing methods.

 
None of the above

 
Fire Resistive time rating

 
Fire spread rating

Correct!  
Fire resistive rating

Question 7 1
/ 1 pts

The scope of National Building code of the Philippines covers all building
related discipline except the following:

 
Indigenous Family Dwelling & PD 1096

 
Indigenous Family Dwelling & RA 9514

 
Indigenous Family Dwelling & BP 344

Correct!  
Indigenous Family Dwelling & BPP 220

Question 8 1
/ 1 pts

https://tip.instructure.com/courses/29639/quizzes/428764 4/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

What type of water distribution system will you recommend for a high rise
building?

 
Pressurized

 
Upfeed

 
Serviced

Correct!  
Downfeed

Question 9 0
/ 1 pts

                              

These are areas where siting of buildings/structures are permitted without


fire-resistivity measures, often located in the country sides or rural areas.

 
Highly Fire Restrictive Zone

orrect answer  
Non-Fire Restricted Zones

ou Answered  
Fire Zones

 
Fire Restrictive Zones

Question 10 1
/ 1 pts

https://tip.instructure.com/courses/29639/quizzes/428764 5/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

A change in the use or occupancy of buildings/structures or any portion/s


thereof, which has different requirements.

 
Addition

 
Alteration

Correct!  
Conversion

 
Renovation

Question 11 1
/ 1 pts

What is the comfortable and minimum area for sleeping quarters of a Call
Center?

 
10 sq. m

Correct!  
18 sq. m.

 
16 sq. m.

 
12 sq. m.

Question 12 0
/ 1 pts

Who is responsible for the preparation of a building evacuation route in


case of fire or earthquake?

https://tip.instructure.com/courses/29639/quizzes/428764 6/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

 
Facilities manager

orrect answer  
Architect

 
Fire department head

ou Answered  
Falar consultant

Question 13 0
/ 1 pts

ou Answered  
No answer text provided.

orrect answer  
No answer text provided.

 
No answer text provided.

 
No answer text provided.

Question 14 1
/ 1 pts

Correct!  
No answer text provided.

 
No answer text provided.

 
No answer text provided.

https://tip.instructure.com/courses/29639/quizzes/428764 7/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

 
No answer text provided.

Question 15 1
/ 1 pts

What critical spatial and dimensional standards must guide the design of
a proposed vehicular system?

 
Maximized on-street parking

 
Provision of basement

 
Safe setback and clearances

Correct!  
Adequate maneuvering room for various type of vehicle

Question 16 1
/ 1 pts

In a hospital, which area does not require the installation of a counter and
sink?

Correct!  
None of the choices

 
New born

 
Pantry

 
Pharmacy

https://tip.instructure.com/courses/29639/quizzes/428764 8/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

Question 17 0
/ 1 pts

This type of construction shall be made of four-hour fire-resistive


throughout material and the structural elements shall be of steel, iron,   
concrete, or masonry construction.

orrect answer  
Type V

ou Answered  
Type IV

 
Type III

 
Type II

Question 18 0
/ 1 pts

How will you incorporate functionality and efficiency to an apartment


building?

orrect answer  
Segregate zoning for functional and utilitarian spaces.

ou Answered  
Zone utilitarian spaces first then functional spaces.

 
Combine zoning for both functional and utilitarian spaces.

 
Zone functional spaces first then utilitarian spaces.

https://tip.instructure.com/courses/29639/quizzes/428764 9/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

Question 19 1
/ 1 pts

What is used to regulate pedestrian flow inside buildings?

 
Security guard

Correct!  
Turnstile

 
Exit plan

 
CCTV

Question 20 1
/ 1 pts

What is a safe ampacity rating of a branch circuit for a combined lighting


and non-lighting outlets of condominium unit?

 
20 AMPS

 
40 AMPS

 
10 AMPS

Correct!  
50 AMPS

Question 21 1
/ 1 pts

https://tip.instructure.com/courses/29639/quizzes/428764 10/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

            A change in the use or occupancy of buildings/structures or any


portion/s thereof, which has different requirements.

 
Renovation

Correct!  
Conversion

 
Repair

 
Alteration

Question 22 0
/ 1 pts

What should be the minimum clear ceiling height of a hallway for an office
building?

 
2.3m

ou Answered  
2.4m

 
2.2m

orrect answer  
2.1m

Question 23 1
/ 1 pts

https://tip.instructure.com/courses/29639/quizzes/428764 11/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

. In terms of cost reduction, operational efficiency and comfort of users,


which is less needed in an office building?

 
Artificial ventilation

 
LAN connectivity

Correct!  
Hot water supply

 
Common toilet

Question 24 0
/ 1 pts

What air conditioning system will you recommend for an office of a


medium-sized company?

ou Answered  
VRV central

orrect answer  
Split type

 
Window type

 
Centralized

Question 25 1
/ 1 pts

What must be incorporated in an office building?

 
Roof deck

https://tip.instructure.com/courses/29639/quizzes/428764 12/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

 
Basement

 
Chapel

Correct!  
Pool

Question 26 1
/ 1 pts

              

The transfer of buildings/structures or portion/s thereof from original


location or position to another, either within the same lot or to a different
one.

 
Renovation

 
Alteration

Correct!  
Moving

 
Demolition

Question 27 1
/ 1 pts

Which of the following occupancies requires a power surge protector?

 
High rise office building

https://tip.instructure.com/courses/29639/quizzes/428764 13/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

Correct!  
Technical training center

 
Automobile assembly hall

 
Gymnasium

Question 28 1
/ 1 pts

Any new construction which increases the height and/or floor area of
existing buildings/structures. 

Correct!  
Addition

 
Conversion

 
Renovation

 
Alteration

Question 29 0
/ 1 pts

What must be the priority sequence in regard with proper orientation of a


building?

 
Wind, solar, noise, odor, privacy, view

ou Answered  
Solar, wind, noise, odor, privacy, view

 
Noise, odor, privacy, view, solar, wind

https://tip.instructure.com/courses/29639/quizzes/428764 14/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

orrect answer  
) Privacy, view, solar, wind, noise, odor

Question 30 1
/ 1 pts

Which of the following in not considered as an architectural interior


element?

 
Elevator lobby ceiling

Correct!  
Eaves

 
Bathroom floor

 
Unit party wall

Question 31 0
/ 1 pts

Which of the following floor finishes will you specify for an office (busy
general staff area) of an international marketing company?

 
Laminated planks

orrect answer  
Locally distributed vinyl tiles

 
Engineered wood

ou Answered  
Imported vinyl tiles

https://tip.instructure.com/courses/29639/quizzes/428764 15/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

Question 32 1
/ 1 pts

A flooring material that is slippery when dust accumulates on it

 
) Bricks

 
Cement

Correct!  
Ceramic

 
Granite

Question 33 1
/ 1 pts

What is the minimum height of an office table?

 
70 cm

 
90 cm

 
80 cm

Correct!  
76 cm

Question 34 1
/ 1 pts

The systematic dismantling or destruction of a building/structure, in whole


or in part.

https://tip.instructure.com/courses/29639/quizzes/428764 16/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

Correct!  
Demolition

 
Renovation

 
Renovation

 
Alteration

Question 35 1
/ 1 pts

For a rehearsal studio, what will you provide to create a sound lock for it?

 
Sound absorbent materials within masonry walls

Correct!  
Two swing doors with space in-between with absorptive floor material

 
) EPDM weather-stripping

 
Sprayed-on insulation

Question 36 1
/ 1 pts

A document issued by the Building Official (BO) to an owner/applicant


when the building design application is found satisfactory and
substantially conforming with the National Building Code of the
Philippines.

 
Ancillary Permit

https://tip.instructure.com/courses/29639/quizzes/428764 17/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

 
Mayor’s Permit

Correct!  
Building Permit

 
Accessory Permit

Question 37 1
/ 1 pts

Areas wherein siting of buildings/structures are permitted within


prescribed fire-resistivity measures for exterior walls of at least two-hour
fire resistivity. Usual locations in suburban areas

Correct!  
Fire Restrictive Zones

 
Fire Zones

 
Non-Fire Restricted Zones

 
Highly Fire Restrictive Zone

Question 38 0
/ 1 pts

What is the minimum size of an office table?

 
2 feet – 8 inches

 
3 feet

ou Answered  
3 feet – 6 inches

https://tip.instructure.com/courses/29639/quizzes/428764 18/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

orrect answer  
2 feet

Question 39 1
/ 1 pts

Which of the following is not a fixture used for residential buildings?

 
Tissue holder

 
Pendant lighting

Correct!  
Wall hanging

 
Luminaire

Question 40 1
/ 1 pts

What should be the height of a modular partition for it to be effective in


noise reduction and efficiency of staff communication?

 
1.2m

 
1.0m

Correct!  
1.5m

 
1.8m

Question 41 0
/ 1 pts

https://tip.instructure.com/courses/29639/quizzes/428764 19/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

. What should be the appropriate clear span of beams for an office


building?

 
6 m

 
4m

ou Answered  
8 m

orrect answer  
10 m

Question 42 1
/ 1 pts

. A common but inefficient mounting location for air conditioning units

 
Near ceiling

Correct!  
Near floor

 
Middle part but near floor

 
Middle part but near ceiling

Question 43 1
/ 1 pts

A building façade concept is based on?

 
Function and style

 
Design principles

https://tip.instructure.com/courses/29639/quizzes/428764 20/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

 
Character only

Correct!  
Function and design principles

Question 44 0
/ 1 pts

ou Answered  
No answer text provided.

 
No answer text provided.

 
No answer text provided.

orrect answer  
No answer text provided.

Question 45 1
/ 1 pts

What is BP 220?

 
National Building Code of the Philippines

Correct!  
Economic & Socialized Housing Act

 
Revised Fire Code of the Philippines

 
Accessibility Law

Question 46 1
/ 1 pts

https://tip.instructure.com/courses/29639/quizzes/428764 21/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

What type of luminaire is commonly seen in office buildings?

 
Eyeball

 
Pinlight

Correct!  
Troffer

 
Box type

Question 47 1
/ 1 pts

Areas wherein highly fire- resistive or non-combustible


buildings/structures and/or construction assemblies of no less than three
to four-hour fire- resistive construction materials are used throughout,
including exterior walls.

Correct!  
Highly Fire Restrictive Zone

 
Fire Zones

 
Non-Fire Restricted Zones

 
Fire Restrictive Zones

Question 48 Not yet graded


/ 0 pts

Kindly re-write the following statement below.

https://tip.instructure.com/courses/29639/quizzes/428764 22/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

PLEDGE OF HONOR

"I shall affirm that I will not give or receive any unauthorized help on
this exam, and that shall be my own"

Your answer:

"I shall affirm that I will not give or receive any unauthorized help on
this exam, and that shall be my own"

Question 49 0
/ 1 pts

Q:

What is the maximum allowable percentage of site occupancy?

----------------

PROJECT# 1: High-Rise Condominium Building

A dynamic development company has decided that its R-5 zoned property
with total lot of 1470 sq. m. And located in Quezon City shall host a high-
Rise Condominium development. The residential units shall be 2 types:
Studio unit with 18 sq. m and one bedroom unit with an area of 22 sq. m.
The building shall have a firewall and floor to floor height of 3 meters. The
ground finish floor level is at the point where the slope of the site and the
front outermost face of the building intersect.

The project site is an inside lot with a 35 meter wide frontage facing west;
sloping 3% towards 20 m wide sidewalks at both sides. The surface of the
sidewalk the project site frontage is considered as elevation 0.0m.

 
60%

ou Answered  
80%

https://tip.instructure.com/courses/29639/quizzes/428764 23/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

orrect answer  
65%

 
70%

Question 50 1
/ 1 pts

Q: Who shall sign the architectural plans of the condominium building?

--------------

PROJECT# 1: High-Rise Condominium Building

A dynamic development company has decided that its R-5 zoned property
with total lot of 1470 sq. m. And located in Quezon City shall host a high-
Rise Condominium development. The residential units shall be 2 types:
Studio unit with 18 sq. m and one bedroom unit with an area of 22 sq. m.
The building shall have a firewall and floor to floor height of 3 meters. The
ground finish floor level is at the point where the slope of the site and the
front outermost face of the building intersect.

The project site is an inside lot with a 35 meter wide frontage facing west;
sloping 3% towards 20 m wide sidewalks at both sides. The surface of the
sidewalk the project site frontage is considered as elevation 0.0m.

 
Licensed Architect

 
Registered Architect

Correct!  
Registered & Licensed Architect

 
Civil Engineer

https://tip.instructure.com/courses/29639/quizzes/428764 24/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

Question 51 0
/ 1 pts

Q: What shall be the building height limit in meters?       

-----------

PROJECT# 1: High-Rise Condominium Building

A dynamic development company has decided that its R-5 zoned property
with total lot of 1470 sq. m. And located in Quezon City shall host a high-
Rise Condominium development. The residential units shall be 2 types:
Studio unit with 18 sq. m and one bedroom unit with an area of 22 sq. m.
The building shall have a firewall and floor to floor height of 3 meters. The
ground finish floor level is at the point where the slope of the site and the
front outermost face of the building intersect.

The project site is an inside lot with a 35 meter wide frontage facing west;
sloping 3% towards 20 m wide sidewalks at both sides. The surface of the
sidewalk the project site frontage is considered as elevation 0.0m.

ou Answered  
36

 
10

orrect answer  
54

 
18

Question 52 0
/ 1 pts

Q:

In Multi-Storey condominium building, what is the best use to complement


the residential area?

https://tip.instructure.com/courses/29639/quizzes/428764 25/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

--------------

PROJECT# 1: High-Rise Condominium Building

A dynamic development company has decided that its R-5 zoned property
with total lot of 1470 sq. m. And located in Quezon City shall host a high-
Rise Condominium development. The residential units shall be 2 types:
Studio unit with 18 sq. m and one bedroom unit with an area of 22 sq. m.
The building shall have a firewall and floor to floor height of 3 meters. The
ground finish floor level is at the point where the slope of the site and the
front outermost face of the building intersect.

The project site is an inside lot with a 35 meter wide frontage facing west;
sloping 3% towards 20 m wide sidewalks at both sides. The surface of the
sidewalk the project site frontage is considered as elevation 0.0m.

ou Answered  
Business

orrect answer  
Commercial

 
Recreational

 
Entertainment

Question 53 0
/ 1 pts

Q:What is NOT included in Deign Development Stage?

--------------------

PROJECT# 1: High-Rise Condominium Building

A dynamic development company has decided that its R-5 zoned property
with total lot of 1470 sq. m. And located in Quezon City shall host a high-
Rise Condominium development. The residential units shall be 2 types:
Studio unit with 18 sq. m and one bedroom unit with an area of 22 sq. m.

https://tip.instructure.com/courses/29639/quizzes/428764 26/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

The building shall have a firewall and floor to floor height of 3 meters. The
ground finish floor level is at the point where the slope of the site and the
front outermost face of the building intersect.

The project site is an inside lot with a 35 meter wide frontage facing west;
sloping 3% towards 20 m wide sidewalks at both sides. The surface of the
sidewalk the project site frontage is considered as elevation 0.0m.

ou Answered  
Cost Estimates

orrect answer  
Engineering Plans

 
Floor Plans and Elevations

 
Outline Specification

Question 54 1
/ 1 pts

Which of the following is not considered an amenity for the condominium


building?

-----------

PROJECT# 1: High-Rise Condominium Building

A dynamic development company has decided that its R-5 zoned property
with total lot of 1470 sq. m. And located in Quezon City shall host a high-
Rise Condominium development. The residential units shall be 2 types:
Studio unit with 18 sq. m and one bedroom unit with an area of 22 sq. m.
The building shall have a firewall and floor to floor height of 3 meters. The
ground finish floor level is at the point where the slope of the site and the
front outermost face of the building intersect.

https://tip.instructure.com/courses/29639/quizzes/428764 27/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

The project site is an inside lot with a 35 meter wide frontage facing west;
sloping 3% towards 20 m wide sidewalks at both sides. The surface of the
sidewalk the project site frontage is considered as elevation 0.0m.

 
Swimming Pool

 
Free Wi-Fi at lobby

Correct!  
Multi-purpose Hall

 
Fitness Gym

Question 55 1
/ 1 pts

Q: A ramp shall be provided as access to the entrance of an office


building not on the same level of the site. What should be the slope of the
ramp?

PROJECT# 1: High-Rise Condominium Building

A dynamic development company has decided that its R-5 zoned property
with total lot of 1470 sq. m. And located in Quezon City shall host a high-
Rise Condominium development. The residential units shall be 2 types:
Studio unit with 18 sq. m and one bedroom unit with an area of 22 sq. m.
The building shall have a firewall and floor to floor height of 3 meters. The
ground finish floor level is at the point where the slope of the site and the
front outermost face of the building intersect.

The project site is an inside lot with a 35 meter wide frontage facing west;
sloping 3% towards 20 m wide sidewalks at both sides. The surface of the
sidewalk the project site frontage is considered as elevation 0.0m.

 
10%

https://tip.instructure.com/courses/29639/quizzes/428764 28/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

 
9.09%

 
12%

Correct!  
8.33%

Question 56 1
/ 1 pts

Q: What is the minimum area of an elevator car to accommodate a


disabled person according to the BP 344?

----------------

PROJECT# 1: High-Rise Condominium Building

A dynamic development company has decided that its R-5 zoned property
with total lot of 1470 sq. m. And located in Quezon City shall host a high-
Rise Condominium development. The residential units shall be 2 types:
Studio unit with 18 sq. m and one bedroom unit with an area of 22 sq. m.
The building shall have a firewall and floor to floor height of 3 meters. The
ground finish floor level is at the point where the slope of the site and the
front outermost face of the building intersect.

The project site is an inside lot with a 35 meter wide frontage facing west;
sloping 3% towards 20 m wide sidewalks at both sides. The surface of the
sidewalk the project site frontage is considered as elevation 0.0m.

Correct!  
1.54 sq. m

 
5.0 sqm.

 
3.06 sq. m

 
2.40 sq. m

https://tip.instructure.com/courses/29639/quizzes/428764 29/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

Question 57 1
/ 1 pts

Q:

What shall be minimum total space within lot?

-----------

PROJECT# 1: High-Rise Condominium Building

A dynamic development company has decided that its R-5 zoned property
with total lot of 1470 sq. m. And located in Quezon City shall host a high-
Rise Condominium development. The residential units shall be 2 types:
Studio unit with 18 sq. m and one bedroom unit with an area of 22 sq. m.
The building shall have a firewall and floor to floor height of 3 meters. The
ground finish floor level is at the point where the slope of the site and the
front outermost face of the building intersect.

The project site is an inside lot with a 35 meter wide frontage facing west;
sloping 3% towards 20 m wide sidewalks at both sides. The surface of the
sidewalk the project site frontage is considered as elevation 0.0m.

 
45% of TLA

Correct!  
35% of TLA

 
40% of TLA

 
50% of TLA

Question 58 1
/ 1 pts

https://tip.instructure.com/courses/29639/quizzes/428764 30/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

Q:

Which of the following should not be placed inside a building’s basement


level?

--------------

PROJECT# 1: High-Rise Condominium Building

A dynamic development company has decided that its R-5 zoned property
with total lot of 1470 sq. m. And located in Quezon City shall host a high-
Rise Condominium development. The residential units shall be 2 types:
Studio unit with 18 sq. m and one bedroom unit with an area of 22 sq. m.
The building shall have a firewall and floor to floor height of 3 meters. The
ground finish floor level is at the point where the slope of the site and the
front outermost face of the building intersect.

The project site is an inside lot with a 35 meter wide frontage facing west;
sloping 3% towards 20 m wide sidewalks at both sides. The surface of the
sidewalk the project site frontage is considered as elevation 0.0m.

 
Garbage Room

 
Storage

Correct!  
Incinerator

 
Parking

Question 59 0
/ 1 pts

Q: At What elevation of the site shall the measurement of building height


limit start?

https://tip.instructure.com/courses/29639/quizzes/428764 31/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

PROJECT# 1: High-Rise Condominium Building

A dynamic development company has decided that its R-5 zoned property
with total lot of 1470 sq. m. And located in Quezon City shall host a high-
Rise Condominium development. The residential units shall be 2 types:
Studio unit with 18 sq. m and one bedroom unit with an area of 22 sq. m.
The building shall have a firewall and floor to floor height of 3 meters. The
ground finish floor level is at the point where the slope of the site and the
front outermost face of the building intersect.

The project site is an inside lot with a 35 meter wide frontage facing west;
sloping 3% towards 20 m wide sidewalks at both sides. The surface of the
sidewalk the project site frontage is considered as elevation 0.0m.

ou Answered  
) +0.68

orrect answer  
+1.17

 
0

 
+0.18

Question 60 1
/ 1 pts

Q:

What is the allowable maximum building footprint?

----------------

PROJECT# 1: High-Rise Condominium Building

https://tip.instructure.com/courses/29639/quizzes/428764 32/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

A dynamic development company has decided that its R-5 zoned property
with total lot of 1470 sq. m. And located in Quezon City shall host a high-
Rise Condominium development. The residential units shall be 2 types:
Studio unit with 18 sq. m and one bedroom unit with an area of 22 sq. m.
The building shall have a firewall and floor to floor height of 3 meters. The
ground finish floor level is at the point where the slope of the site and the
front outermost face of the building intersect.

The project site is an inside lot with a 35 meter wide frontage facing west;
sloping 3% towards 20 m wide sidewalks at both sides. The surface of the
sidewalk the project site frontage is considered as elevation 0.0m.

 
882 sq. m

Correct!  
957 sq. m

 
1176 sq. m

 
1029sq. m

Question 61 1
/ 1 pts

Q:What shall be the maximum GFA of the building?

--------------------

PROJECT# 1: High-Rise Condominium Building

A dynamic development company has decided that its R-5 zoned property
with total lot of 1470 sq. m. And located in Quezon City shall host a high-
Rise Condominium development. The residential units shall be 2 types:
Studio unit with 18 sq. m and one bedroom unit with an area of 22 sq. m.
The building shall have a firewall and floor to floor height of 3 meters. The

https://tip.instructure.com/courses/29639/quizzes/428764 33/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

ground finish floor level is at the point where the slope of the site and the
front outermost face of the building intersect.

The project site is an inside lot with a 35 meter wide frontage facing west;
sloping 3% towards 20 m wide sidewalks at both sides. The surface of the
sidewalk the project site frontage is considered as elevation 0.0m.

 
15876 sq. m

Correct!  
13230 sq. m

 
21168 sq. m

 
17876sq. m

Question 62 1
/ 1 pts

Q: Assuming the site will be on a converted rice field, what is the best soil
must the foundation rest?

--------------

PROJECT# 1: High-Rise Condominium Building

A dynamic development company has decided that its R-5 zoned property
with total lot of 1470 sq. m. And located in Quezon City shall host a high-
Rise Condominium development. The residential units shall be 2 types:
Studio unit with 18 sq. m and one bedroom unit with an area of 22 sq. m.
The building shall have a firewall and floor to floor height of 3 meters. The
ground finish floor level is at the point where the slope of the site and the
front outermost face of the building intersect.

The project site is an inside lot with a 35 meter wide frontage facing west;
sloping 3% towards 20 m wide sidewalks at both sides. The surface of the
sidewalk the project site frontage is considered as elevation 0.0m.
https://tip.instructure.com/courses/29639/quizzes/428764 34/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

 
Hard

 
Soft

Correct!  
Very hard

 
Very Soft

Question 63 0
/ 1 pts

Q: Who shall check the shop drawing?

--------------------

PROJECT# 1: High-Rise Condominium Building

A dynamic development company has decided that its R-5 zoned property
with total lot of 1470 sq. m. And located in Quezon City shall host a high-
Rise Condominium development. The residential units shall be 2 types:
Studio unit with 18 sq. m and one bedroom unit with an area of 22 sq. m.
The building shall have a firewall and floor to floor height of 3 meters. The
ground finish floor level is at the point where the slope of the site and the
front outermost face of the building intersect.

The project site is an inside lot with a 35 meter wide frontage facing west;
sloping 3% towards 20 m wide sidewalks at both sides. The surface of the
sidewalk the project site frontage is considered as elevation 0.0m.

 
Contractor

orrect answer  
Architect

ou Answered  
Construction manager

https://tip.instructure.com/courses/29639/quizzes/428764 35/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

 
Supplier

Question 64 1
/ 1 pts

Q:According to NBCP in Rule 12, what is the occupant load factor of


dining establishment?

---------

PROJECT #2: GARMENTS FACTORY

A multi-national company, Far East Garments Manufacturing Inc. (The


Client), has decided to expand its operation in Asia and put up
a GARMENTS FACTORY (The Project) in an Industrial Area at the Subic
Freeport, Olongapo City, Zambales. The factory shall be erected in
a through-lot a Total Lot Area (TLA) of 5,000.00 sq. m. The lot’s 50
meters wide frontage faces north and bounded by a 21.00 meters wide
street. The rear lot faces South on an 18.00 meters wide road right of
way. The rectangular lot which has a depth of 100.00 meters has a
moderate slope of 4 % towards the narrower street.

The Garments Factory is envisioned to be one of the most modern


manufacturing plants in Asia having its aim of providing service to the big
name brands in clothing industry. The major stock holder of the company
is a known environmentalist thus they have hired an Architect who is also
a known practitioner of Green Architecture.

The site bounded on the North by a wide street with 2.40 meters side
walk on each side while the narrower RROW is bounded by a 1.80
meter side walk on each side. To the east of the site is
another garments factory and to its west is a plastic factory.
Across the wider street is a newly-built shoe factory. The rear side of
the lot faces a tire factory.

The following development controls apply to the project site:

1. Zoning Classification is a I-2 (Industrial Two)- a medium industrial


use or occupancy,

https://tip.instructure.com/courses/29639/quizzes/428764 36/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

2. Base on the NCBP 2005 Revised Implementing Rules and


Regulations (R-IRR)

The project site has the following development limitations:

1. The prescribed minimum setbacks at ground floor are 00 meters at


front and 3.0 meter at sides and rear.
2. A building Height Limit (BHL) of 21.00 meters but not exceed the
duly-approved BHL in the major zone it is part of
3. A minimum required parking of 1 bus slot for every 100 workers, 1
loading slot for articulated truck, and 1 loading slot for a standard
truck
4. Provide truck maneuvering area outside the RROW (with in property
lines only).

The Stated Project requirements are as follows:

1. Administration (Two floors)


2. Reception Room
3. Executive area
4. Department Office
5. Conference Room
6. Toilets
7. Employees Facilities ( Ground Floor)
8. Cafeteria
9. Quite Lounges
10. Recreation Area
11. Factory Men’s & Women’s Lockers & Toilet
12. Office Men’s & Women’s Lockers & Toilet
13. Meeting Rooms
14. First Aid Clinic
15. Operations & Maintenance
16. Manufacturing Area
17. Warehousing Area/ Truck Loading Area
18. Utilities
19. Generator Room
20. Domestic Water Cistern
21. Overhead Water
22. Pump Room

https://tip.instructure.com/courses/29639/quizzes/428764 37/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

23. Solid Waste Stora

 
9.30 sq. m

Correct!  
1.40 sq. m

 
28.00 sq. m

 
1.80 sq. m

Question 65 1
/ 1 pts

Q: The Site slopes gently towards 18 m Wide Street at 4%. What is the
difference between the rear and front portions of the lot?

---------

PROJECT #2: GARMENTS FACTORY

A multi-national company, Far East Garments Manufacturing Inc. (The


Client), has decided to expand its operation in Asia and put up
a GARMENTS FACTORY (The Project) in an Industrial Area at the Subic
Freeport, Olongapo City, Zambales. The factory shall be erected in
a through-lot a Total Lot Area (TLA) of 5,000.00 sq. m. The lot’s 50
meters wide frontage faces north and bounded by a 21.00 meters wide
street. The rear lot faces South on an 18.00 meters wide road right of
way. The rectangular lot which has a depth of 100.00 meters has a
moderate slope of 4 % towards the narrower street.

The Garments Factory is envisioned to be one of the most modern


manufacturing plants in Asia having its aim of providing service to the big
name brands in clothing industry. The major stock holder of the company
is a known environmentalist thus they have hired an Architect who is also
a known practitioner of Green Architecture.

The site bounded on the North by a wide street with 2.40 meters side
walk on each side while the narrower RROW is bounded by a 1.80
meter side walk on each side. To the east of the site is

https://tip.instructure.com/courses/29639/quizzes/428764 38/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

another garments factory and to its west is a plastic factory.


Across the wider street is a newly-built shoe factory. The rear side of
the lot faces a tire factory.

The following development controls apply to the project site:

1. Zoning Classification is a I-2 (Industrial Two)- a medium industrial


use or occupancy,
2. Base on the NCBP 2005 Revised Implementing Rules and
Regulations (R-IRR)

The project site has the following development limitations:

1. The prescribed minimum setbacks at ground floor are 00 meters at


front and 3.0 meter at sides and rear.
2. A building Height Limit (BHL) of 21.00 meters but not exceed the
duly-approved BHL in the major zone it is part of
3. A minimum required parking of 1 bus slot for every 100 workers, 1
loading slot for articulated truck, and 1 loading slot for a standard
truck
4. Provide truck maneuvering area outside the RROW (with in property
lines only).

The Stated Project requirements are as follows:

1. Administration (Two floors)


2. Reception Room
3. Executive area
4. Department Office
5. Conference Room
6. Toilets
7. Employees Facilities ( Ground Floor)
8. Cafeteria
9. Quite Lounges
10. Recreation Area
11. Factory Men’s & Women’s Lockers & Toilet
12. Office Men’s & Women’s Lockers & Toilet
13. Meeting Rooms
14. First Aid Clinic
15. Operations & Maintenance

https://tip.instructure.com/courses/29639/quizzes/428764 39/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

16. Manufacturing Area


17. Warehousing Area/ Truck Loading Area
18. Utilities
19. Generator Room
20. Domestic Water Cistern
21. Overhead Water
22. Pump Room
23. Solid Waste Stora

 
5.00 m

 
3.40 m

Correct!  
4.00 m

 
4.50 m

Question 66 0
/ 1 pts

Q: Any ramp for the disabled with a rise greater than.20m and leads down
towards as area where vehicular traffic is possible, should have a railing
across the full width of its lower end not less than _____ from the foot of
the ramp.

-----------

PROJECT #2: GARMENTS FACTORY

A multi-national company, Far East Garments Manufacturing Inc. (The


Client), has decided to expand its operation in Asia and put up a
GARMENTS FACTORY (The Project) in an Industrial Area at the Subic
Freeport, Olongapo City, Zambales. The factory shall be erected in a
through-lot a Total Lot Area (TLA) of 5,000.00 sq. m. The lot’s 50
meters wide frontage faces north and bounded by a 21.00 meters wide
street. The rear lot faces South on an 18.00 meters wide road right of
way. The rectangular lot which has a depth of 100.00 meters has a
moderate slope of 4 % towards the narrower street.

https://tip.instructure.com/courses/29639/quizzes/428764 40/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

The Garments Factory is envisioned to be one of the most modern


manufacturing plants in Asia having its aim of providing service to the big
name brands in clothing industry. The major stock holder of the company
is a known environmentalist thus they have hired an Architect who is also
a known practitioner of Green Architecture.

The site bounded on the North by a wide street with 2.40 meters side
walk on each side while the narrower RROW is bounded by a 1.80
meter side walk on each side. To the east of the site is another
garments factory and to its west is a plastic factory. Across the wider
street is a newly-built shoe factory. The rear side of the lot faces a tire
factory.

The following development controls apply to the project site:

1. Zoning Classification is a I-2 (Industrial Two)- a medium industrial


use or occupancy,
2. Base on the NCBP 2005 Revised Implementing Rules and
Regulations (R-IRR)

The project site has the following development limitations:

1. The prescribed minimum setbacks at ground floor are 00 meters at


front and 3.0 meter at sides and rear.
2. A building Height Limit (BHL) of 21.00 meters but not exceed the
duly-approved BHL in the major zone it is part of
3. A minimum required parking of 1 bus slot for every 100 workers, 1
loading slot for articulated truck, and 1 loading slot for a standard
truck
4. Provide truck maneuvering area outside the RROW (with in property
lines only).

The Stated Project requirements are as follows:

1. Administration (Two floors)


2. Reception Room
3. Executive area
4. Department Office
5. Conference Room
6. Toilets
7. Employees Facilities ( Ground Floor)
https://tip.instructure.com/courses/29639/quizzes/428764 41/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

8. Cafeteria
9. Quite Lounges
10. Recreation Area
11. Factory Men’s & Women’s Lockers & Toilet
12. Office Men’s & Women’s Lockers & Toilet
13. Meeting Rooms
14. First Aid Clinic
15. Operations & Maintenance
16. Manufacturing Area
17. Warehousing Area/ Truck Loading Area
18. Utilities
19. Generator Room
20. Domestic Water Cistern
21. Overhead Water
22. Pump Room
23. Solid Waste Storage

 
2.00m

ou Answered  
1.80m

orrect answer  
1.50m

 
1.20m

Question 67 1
/ 1 pts

Q:

Based on the correct answer of 155, how much minimum floor space
should you allot for the warehouse of this project if there are 6
warehousemen who will occupy it?

https://tip.instructure.com/courses/29639/quizzes/428764 42/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

---------

PROJECT #2: GARMENTS FACTORY

A multi-national company, Far East Garments Manufacturing Inc. (The


Client), has decided to expand its operation in Asia and put up
a GARMENTS FACTORY (The Project) in an Industrial Area at the Subic
Freeport, Olongapo City, Zambales. The factory shall be erected in
a through-lot a Total Lot Area (TLA) of 5,000.00 sq. m. The lot’s 50
meters wide frontage faces north and bounded by a 21.00 meters wide
street. The rear lot faces South on an 18.00 meters wide road right of
way. The rectangular lot which has a depth of 100.00 meters has a
moderate slope of 4 % towards the narrower street.

The Garments Factory is envisioned to be one of the most modern


manufacturing plants in Asia having its aim of providing service to the big
name brands in clothing industry. The major stock holder of the company
is a known environmentalist thus they have hired an Architect who is also
a known practitioner of Green Architecture.

The site bounded on the North by a wide street with 2.40 meters side
walk on each side while the narrower RROW is bounded by a 1.80
meter side walk on each side. To the east of the site is
another garments factory and to its west is a plastic factory.
Across the wider street is a newly-built shoe factory. The rear side of
the lot faces a tire factory.

The following development controls apply to the project site:

1. Zoning Classification is a I-2 (Industrial Two)- a medium industrial


use or occupancy,
2. Base on the NCBP 2005 Revised Implementing Rules and
Regulations (R-IRR)

The project site has the following development limitations:

1. The prescribed minimum setbacks at ground floor are 00 meters at


front and 3.0 meter at sides and rear.
2. A building Height Limit (BHL) of 21.00 meters but not exceed the
duly-approved BHL in the major zone it is part of

https://tip.instructure.com/courses/29639/quizzes/428764 43/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

3. A minimum required parking of 1 bus slot for every 100 workers, 1
loading slot for articulated truck, and 1 loading slot for a standard
truck
4. Provide truck maneuvering area outside the RROW (with in property
lines only).

The Stated Project requirements are as follows:

1. Administration (Two floors)


2. Reception Room
3. Executive area
4. Department Office
5. Conference Room
6. Toilets
7. Employees Facilities ( Ground Floor)
8. Cafeteria
9. Quite Lounges
10. Recreation Area
11. Factory Men’s & Women’s Lockers & Toilet
12. Office Men’s & Women’s Lockers & Toilet
13. Meeting Rooms
14. First Aid Clinic
15. Operations & Maintenance
16. Manufacturing Area
17. Warehousing Area/ Truck Loading Area
18. Utilities
19. Generator Room
20. Domestic Water Cistern
21. Overhead Water
22. Pump Room
23. Solid Waste Stora

 
10.8 sq. m

 
55.8 sq. m

Correct!  
168 sq. m

 
8.5 sq. m

https://tip.instructure.com/courses/29639/quizzes/428764 44/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

Question 68 0
/ 1 pts

Q:

How about the Senior Vice President?

--------------

PROJECT #2: GARMENTS FACTORY

A multi-national company, Far East Garments Manufacturing Inc. (The


Client), has decided to expand its operation in Asia and put up
a GARMENTS FACTORY (The Project) in an Industrial Area at the Subic
Freeport, Olongapo City, Zambales. The factory shall be erected in
a through-lot a Total Lot Area (TLA) of 5,000.00 sq. m. The lot’s 50
meters wide frontage faces north and bounded by a 21.00 meters wide
street. The rear lot faces South on an 18.00 meters wide road right of
way. The rectangular lot which has a depth of 100.00 meters has a
moderate slope of 4 % towards the narrower street.

The Garments Factory is envisioned to be one of the most modern


manufacturing plants in Asia having its aim of providing service to the big
name brands in clothing industry. The major stock holder of the company
is a known environmentalist thus they have hired an Architect who is also
a known practitioner of Green Architecture.

The site bounded on the North by a wide street with 2.40 meters side
walk on each side while the narrower RROW is bounded by a 1.80
meter side walk on each side. To the east of the site is
another garments factory and to its west is a plastic factory.
Across the wider street is a newly-built shoe factory. The rear side of
the lot faces a tire factory.

The following development controls apply to the project site:

1. Zoning Classification is a I-2 (Industrial Two)- a medium industrial


use or occupancy,

https://tip.instructure.com/courses/29639/quizzes/428764 45/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

2. Base on the NCBP 2005 Revised Implementing Rules and


Regulations (R-IRR)

The project site has the following development limitations:

1. The prescribed minimum setbacks at ground floor are 00 meters at


front and 3.0 meter at sides and rear.
2. A building Height Limit (BHL) of 21.00 meters but not exceed the
duly-approved BHL in the major zone it is part of
3. A minimum required parking of 1 bus slot for every 100 workers, 1
loading slot for articulated truck, and 1 loading slot for a standard
truck
4. Provide truck maneuvering area outside the RROW (with in property
lines only).

The Stated Project requirements are as follows:

1. Administration (Two floors)


2. Reception Room
3. Executive area
4. Department Office
5. Conference Room
6. Toilets
7. Employees Facilities ( Ground Floor)
8. Cafeteria
9. Quite Lounges
10. Recreation Area
11. Factory Men’s & Women’s Lockers & Toilet
12. Office Men’s & Women’s Lockers & Toilet
13. Meeting Rooms
14. First Aid Clinic
15. Operations & Maintenance
16. Manufacturing Area
17. Warehousing Area/ Truck Loading Area
18. Utilities
19. Generator Room
20. Domestic Water Cistern
21. Overhead Water
22. Pump Room

https://tip.instructure.com/courses/29639/quizzes/428764 46/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

23. Solid Waste Storage

orrect answer  
18.60 sq. m

ou Answered  
37.20 sq. m

 
9.30 sq. m

 
27.90 sq. m

Question 69 1
/ 1 pts

Q:Door knobs and other hardware should be located betweeb0.82m and


1.06 m above the floor but _____ is preferred

-----------

PROJECT #2: GARMENTS FACTORY

A multi-national company, Far East Garments Manufacturing Inc. (The


Client), has decided to expand its operation in Asia and put up
a GARMENTS FACTORY (The Project) in an Industrial Area at the Subic
Freeport, Olongapo City, Zambales. The factory shall be erected in
a through-lot a Total Lot Area (TLA) of 5,000.00 sq. m. The lot’s 50
meters wide frontage faces north and bounded by a 21.00 meters wide
street. The rear lot faces South on an 18.00 meters wide road right of
way. The rectangular lot which has a depth of 100.00 meters has a
moderate slope of 4 % towards the narrower street.

The Garments Factory is envisioned to be one of the most modern


manufacturing plants in Asia having its aim of providing service to the big
name brands in clothing industry. The major stock holder of the company
is a known environmentalist thus they have hired an Architect who is also
a known practitioner of Green Architecture.

The site bounded on the North by a wide street with 2.40 meters side
walk on each side while the narrower RROW is bounded by a 1.80
meter side walk on each side. To the east of the site is
https://tip.instructure.com/courses/29639/quizzes/428764 47/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

another garments factory and to its west is a plastic factory.


Across the wider street is a newly-built shoe factory. The rear side of
the lot faces a tire factory.

The following development controls apply to the project site:

1. Zoning Classification is a I-2 (Industrial Two)- a medium industrial


use or occupancy,
2. Base on the NCBP 2005 Revised Implementing Rules and
Regulations (R-IRR)

The project site has the following development limitations:

1. The prescribed minimum setbacks at ground floor are 00 meters at


front and 3.0 meter at sides and rear.
2. A building Height Limit (BHL) of 21.00 meters but not exceed the
duly-approved BHL in the major zone it is part of
3. A minimum required parking of 1 bus slot for every 100 workers, 1
loading slot for articulated truck, and 1 loading slot for a standard
truck
4. Provide truck maneuvering area outside the RROW (with in property
lines only).

The Stated Project requirements are as follows:

1. Administration (Two floors)


2. Reception Room
3. Executive area
4. Department Office
5. Conference Room
6. Toilets
7. Employees Facilities ( Ground Floor)
8. Cafeteria
9. Quite Lounges
10. Recreation Area
11. Factory Men’s & Women’s Lockers & Toilet
12. Office Men’s & Women’s Lockers & Toilet
13. Meeting Rooms
14. First Aid Clinic
15. Operations & Maintenance

https://tip.instructure.com/courses/29639/quizzes/428764 48/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

16. Manufacturing Area


17. Warehousing Area/ Truck Loading Area
18. Utilities
19. Generator Room
20. Domestic Water Cistern
21. Overhead Water
22. Pump Room
23. Solid Waste Storage

 
1000mm

 
1050mm

Correct!  
900mm

 
850mm

Question 70 1
/ 1 pts

Q:According to the NBCP in Rule 12, what is the occupant load factor of a
warehouse?

---------

PROJECT #2: GARMENTS FACTORY

A multi-national company, Far East Garments Manufacturing Inc. (The


Client), has decided to expand its operation in Asia and put up
a GARMENTS FACTORY (The Project) in an Industrial Area at the Subic
Freeport, Olongapo City, Zambales. The factory shall be erected in
a through-lot a Total Lot Area (TLA) of 5,000.00 sq. m. The lot’s 50
meters wide frontage faces north and bounded by a 21.00 meters wide
street. The rear lot faces South on an 18.00 meters wide road right of
way. The rectangular lot which has a depth of 100.00 meters has a
moderate slope of 4 % towards the narrower street.

https://tip.instructure.com/courses/29639/quizzes/428764 49/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

The Garments Factory is envisioned to be one of the most modern


manufacturing plants in Asia having its aim of providing service to the big
name brands in clothing industry. The major stock holder of the company
is a known environmentalist thus they have hired an Architect who is also
a known practitioner of Green Architecture.

The site bounded on the North by a wide street with 2.40 meters side
walk on each side while the narrower RROW is bounded by a 1.80
meter side walk on each side. To the east of the site is
another garments factory and to its west is a plastic factory.
Across the wider street is a newly-built shoe factory. The rear side of
the lot faces a tire factory.

The following development controls apply to the project site:

1. Zoning Classification is a I-2 (Industrial Two)- a medium industrial


use or occupancy,
2. Base on the NCBP 2005 Revised Implementing Rules and
Regulations (R-IRR)

The project site has the following development limitations:

1. The prescribed minimum setbacks at ground floor are 00 meters at


front and 3.0 meter at sides and rear.
2. A building Height Limit (BHL) of 21.00 meters but not exceed the
duly-approved BHL in the major zone it is part of
3. A minimum required parking of 1 bus slot for every 100 workers, 1
loading slot for articulated truck, and 1 loading slot for a standard
truck
4. Provide truck maneuvering area outside the RROW (with in property
lines only).

The Stated Project requirements are as follows:

1. Administration (Two floors)


2. Reception Room
3. Executive area
4. Department Office
5. Conference Room
6. Toilets
7. Employees Facilities ( Ground Floor)
https://tip.instructure.com/courses/29639/quizzes/428764 50/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

8. Cafeteria
9. Quite Lounges
10. Recreation Area
11. Factory Men’s & Women’s Lockers & Toilet
12. Office Men’s & Women’s Lockers & Toilet
13. Meeting Rooms
14. First Aid Clinic
15. Operations & Maintenance
16. Manufacturing Area
17. Warehousing Area/ Truck Loading Area
18. Utilities
19. Generator Room
20. Domestic Water Cistern
21. Overhead Water
22. Pump Room
23. Solid Waste Stora

Correct!  
28.00 sq. m

 
9.30 sq. m

 
1.80 sq. m

 
1.40 sq. m

Question 71 1
/ 1 pts

Q: In providing doors for the disabled, there must be a minimum clear


level space of _____before and extending beyond a door?

-----------

PROJECT #2: GARMENTS FACTORY

A multi-national company, Far East Garments Manufacturing Inc. (The


Client), has decided to expand its operation in Asia and put up
a GARMENTS FACTORY (The Project) in an Industrial Area at the Subic

https://tip.instructure.com/courses/29639/quizzes/428764 51/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

Freeport, Olongapo City, Zambales. The factory shall be erected in


a through-lot a Total Lot Area (TLA) of 5,000.00 sq. m. The lot’s 50
meters wide frontage faces north and bounded by a 21.00 meters wide
street. The rear lot faces South on an 18.00 meters wide road right of
way. The rectangular lot which has a depth of 100.00 meters has a
moderate slope of 4 % towards the narrower street.

The Garments Factory is envisioned to be one of the most modern


manufacturing plants in Asia having its aim of providing service to the big
name brands in clothing industry. The major stock holder of the company
is a known environmentalist thus they have hired an Architect who is also
a known practitioner of Green Architecture.

The site bounded on the North by a wide street with 2.40 meters side
walk on each side while the narrower RROW is bounded by a 1.80
meter side walk on each side. To the east of the site is
another garments factory and to its west is a plastic factory.
Across the wider street is a newly-built shoe factory. The rear side of
the lot faces a tire factory.

The following development controls apply to the project site:

1. Zoning Classification is a I-2 (Industrial Two)- a medium industrial


use or occupancy,
2. Base on the NCBP 2005 Revised Implementing Rules and
Regulations (R-IRR)

The project site has the following development limitations:

1. The prescribed minimum setbacks at ground floor are 00 meters at


front and 3.0 meter at sides and rear.
2. A building Height Limit (BHL) of 21.00 meters but not exceed the
duly-approved BHL in the major zone it is part of
3. A minimum required parking of 1 bus slot for every 100 workers, 1
loading slot for articulated truck, and 1 loading slot for a standard
truck
4. Provide truck maneuvering area outside the RROW (with in property
lines only).

The Stated Project requirements are as follows:

https://tip.instructure.com/courses/29639/quizzes/428764 52/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

1. Administration (Two floors)


2. Reception Room
3. Executive area
4. Department Office
5. Conference Room
6. Toilets
7. Employees Facilities ( Ground Floor)
8. Cafeteria
9. Quite Lounges
10. Recreation Area
11. Factory Men’s & Women’s Lockers & Toilet
12. Office Men’s & Women’s Lockers & Toilet
13. Meeting Rooms
14. First Aid Clinic
15. Operations & Maintenance
16. Manufacturing Area
17. Warehousing Area/ Truck Loading Area
18. Utilities
19. Generator Room
20. Domestic Water Cistern
21. Overhead Water
22. Pump Room
23. Solid Waste Storage

Correct!  
1.50m

 
2.00m

 
1.80m

 
1.20m

Question 72 0
/ 1 pts

https://tip.instructure.com/courses/29639/quizzes/428764 53/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

Q:

What is the dominant sun's path of the property?

---------

PROJECT #2: GARMENTS FACTORY

A multi-national company, Far East Garments Manufacturing Inc. (The


Client), has decided to expand its operation in Asia and put up
a GARMENTS FACTORY (The Project) in an Industrial Area at the Subic
Freeport, Olongapo City, Zambales. The factory shall be erected in
a through-lot a Total Lot Area (TLA) of 5,000.00 sq. m. The lot’s 50
meters wide frontage faces north and bounded by a 21.00 meters wide
street. The rear lot faces South on an 18.00 meters wide road right of
way. The rectangular lot which has a depth of 100.00 meters has a
moderate slope of 4 % towards the narrower street.

The Garments Factory is envisioned to be one of the most modern


manufacturing plants in Asia having its aim of providing service to the big
name brands in clothing industry. The major stock holder of the company
is a known environmentalist thus they have hired an Architect who is also
a known practitioner of Green Architecture.

The site bounded on the North by a wide street with 2.40 meters side
walk on each side while the narrower RROW is bounded by a 1.80
meter side walk on each side. To the east of the site is
another garments factory and to its west is a plastic factory.
Across the wider street is a newly-built shoe factory. The rear side of
the lot faces a tire factory.

The following development controls apply to the project site:

1. Zoning Classification is a I-2 (Industrial Two)- a medium industrial


use or occupancy,
2. Base on the NCBP 2005 Revised Implementing Rules and
Regulations (R-IRR)

The project site has the following development limitations:

1. The prescribed minimum setbacks at ground floor are 00 meters at


front and 3.0 meter at sides and rear.

https://tip.instructure.com/courses/29639/quizzes/428764 54/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

2. A building Height Limit (BHL) of 21.00 meters but not exceed the


duly-approved BHL in the major zone it is part of
3. A minimum required parking of 1 bus slot for every 100 workers, 1
loading slot for articulated truck, and 1 loading slot for a standard
truck
4. Provide truck maneuvering area outside the RROW (with in property
lines only).

The Stated Project requirements are as follows:

1. Administration (Two floors)


2. Reception Room
3. Executive area
4. Department Office
5. Conference Room
6. Toilets
7. Employees Facilities ( Ground Floor)
8. Cafeteria
9. Quite Lounges
10. Recreation Area
11. Factory Men’s & Women’s Lockers & Toilet
12. Office Men’s & Women’s Lockers & Toilet
13. Meeting Rooms
14. First Aid Clinic
15. Operations & Maintenance
16. Manufacturing Area
17. Warehousing Area/ Truck Loading Area
18. Utilities
19. Generator Room
20. Domestic Water Cistern
21. Overhead Water
22. Pump Room
23. Solid Waste Stora

 
SW to SE and NW to NE

orrect answer  
SE to SW and NE to NW

ou Answered  
SE to NW and NE to SW

https://tip.instructure.com/courses/29639/quizzes/428764 55/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

 
SE to NW and NW to SE

Question 73 0
/ 1 pts

Q:

Under Rule VIII of the NBCP, what is the Maximum Allowable PSO for an
inidustrail-2 project shall be without fire wall?

---------

PROJECT #2: GARMENTS FACTORY

A multi-national company, Far East Garments Manufacturing Inc. (The


Client), has decided to expand its operation in Asia and put up
a GARMENTS FACTORY (The Project) in an Industrial Area at the Subic
Freeport, Olongapo City, Zambales. The factory shall be erected in
a through-lot a Total Lot Area (TLA) of 5,000.00 sq. m. The lot’s 50
meters wide frontage faces north and bounded by a 21.00 meters wide
street. The rear lot faces South on an 18.00 meters wide road right of
way. The rectangular lot which has a depth of 100.00 meters has a
moderate slope of 4 % towards the narrower street.

The Garments Factory is envisioned to be one of the most modern


manufacturing plants in Asia having its aim of providing service to the big
name brands in clothing industry. The major stock holder of the company
is a known environmentalist thus they have hired an Architect who is also
a known practitioner of Green Architecture.

The site bounded on the North by a wide street with 2.40 meters side
walk on each side while the narrower RROW is bounded by a 1.80
meter side walk on each side. To the east of the site is
another garments factory and to its west is a plastic factory.
Across the wider street is a newly-built shoe factory. The rear side of
the lot faces a tire factory.

The following development controls apply to the project site:

https://tip.instructure.com/courses/29639/quizzes/428764 56/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

1. Zoning Classification is a I-2 (Industrial Two)- a medium industrial


use or occupancy,
2. Base on the NCBP 2005 Revised Implementing Rules and
Regulations (R-IRR)

The project site has the following development limitations:

1. The prescribed minimum setbacks at ground floor are 00 meters at


front and 3.0 meter at sides and rear.
2. A building Height Limit (BHL) of 21.00 meters but not exceed the
duly-approved BHL in the major zone it is part of
3. A minimum required parking of 1 bus slot for every 100 workers, 1
loading slot for articulated truck, and 1 loading slot for a standard
truck
4. Provide truck maneuvering area outside the RROW (with in property
lines only).

The Stated Project requirements are as follows:

1. Administration (Two floors)


2. Reception Room
3. Executive area
4. Department Office
5. Conference Room
6. Toilets
7. Employees Facilities ( Ground Floor)
8. Cafeteria
9. Quite Lounges
10. Recreation Area
11. Factory Men’s & Women’s Lockers & Toilet
12. Office Men’s & Women’s Lockers & Toilet
13. Meeting Rooms
14. First Aid Clinic
15. Operations & Maintenance
16. Manufacturing Area
17. Warehousing Area/ Truck Loading Area
18. Utilities
19. Generator Room
20. Domestic Water Cistern

https://tip.instructure.com/courses/29639/quizzes/428764 57/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

21. Overhead Water


22. Pump Room
23. Solid Waste Stora

orrect answer  
70%

 
90%

ou Answered  
80%

 
75%

Question 74 1
/ 1 pts

Q:

This type of roof is very popular in industrial buildings. It is composed of a


series of small parallel roofs of a triangular cross section, usually
asymmetrical with the shorter slope glazed.

---------

PROJECT #2: GARMENTS FACTORY

A multi-national company, Far East Garments Manufacturing Inc. (The


Client), has decided to expand its operation in Asia and put up
a GARMENTS FACTORY (The Project) in an Industrial Area at the Subic
Freeport, Olongapo City, Zambales. The factory shall be erected in
a through-lot a Total Lot Area (TLA) of 5,000.00 sq. m. The lot’s 50
meters wide frontage faces north and bounded by a 21.00 meters wide
street. The rear lot faces South on an 18.00 meters wide road right of
way. The rectangular lot which has a depth of 100.00 meters has a
moderate slope of 4 % towards the narrower street.

The Garments Factory is envisioned to be one of the most modern


manufacturing plants in Asia having its aim of providing service to the big
name brands in clothing industry. The major stock holder of the company

https://tip.instructure.com/courses/29639/quizzes/428764 58/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

is a known environmentalist thus they have hired an Architect who is also


a known practitioner of Green Architecture.

The site bounded on the North by a wide street with 2.40 meters side
walk on each side while the narrower RROW is bounded by a 1.80
meter side walk on each side. To the east of the site is
another garments factory and to its west is a plastic factory.
Across the wider street is a newly-built shoe factory. The rear side of
the lot faces a tire factory.

The following development controls apply to the project site:

1. Zoning Classification is a I-2 (Industrial Two)- a medium industrial


use or occupancy,
2. Base on the NCBP 2005 Revised Implementing Rules and
Regulations (R-IRR)

The project site has the following development limitations:

1. The prescribed minimum setbacks at ground floor are 00 meters at


front and 3.0 meter at sides and rear.
2. A building Height Limit (BHL) of 21.00 meters but not exceed the
duly-approved BHL in the major zone it is part of
3. A minimum required parking of 1 bus slot for every 100 workers, 1
loading slot for articulated truck, and 1 loading slot for a standard
truck
4. Provide truck maneuvering area outside the RROW (with in property
lines only).

The Stated Project requirements are as follows:

1. Administration (Two floors)


2. Reception Room
3. Executive area
4. Department Office
5. Conference Room
6. Toilets
7. Employees Facilities ( Ground Floor)
8. Cafeteria
9. Quite Lounges
10. Recreation Area
https://tip.instructure.com/courses/29639/quizzes/428764 59/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

11. Factory Men’s & Women’s Lockers & Toilet


12. Office Men’s & Women’s Lockers & Toilet
13. Meeting Rooms
14. First Aid Clinic
15. Operations & Maintenance
16. Manufacturing Area
17. Warehousing Area/ Truck Loading Area
18. Utilities
19. Generator Room
20. Domestic Water Cistern
21. Overhead Water
22. Pump Room
23. Solid Waste Stora

 
Barrel roof

Correct!  
Saw tooth roof

 
Shed roof

 
Gable roof

Question 75 0
/ 1 pts

Q:

How about the Department heads or Supervisor?

--------------

PROJECT #2: GARMENTS FACTORY

A multi-national company, Far East Garments Manufacturing Inc. (The


Client), has decided to expand its operation in Asia and put up
a GARMENTS FACTORY (The Project) in an Industrial Area at the Subic
https://tip.instructure.com/courses/29639/quizzes/428764 60/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

Freeport, Olongapo City, Zambales. The factory shall be erected in


a through-lot a Total Lot Area (TLA) of 5,000.00 sq. m. The lot’s 50
meters wide frontage faces north and bounded by a 21.00 meters wide
street. The rear lot faces South on an 18.00 meters wide road right of
way. The rectangular lot which has a depth of 100.00 meters has a
moderate slope of 4 % towards the narrower street.

The Garments Factory is envisioned to be one of the most modern


manufacturing plants in Asia having its aim of providing service to the big
name brands in clothing industry. The major stock holder of the company
is a known environmentalist thus they have hired an Architect who is also
a known practitioner of Green Architecture.

The site bounded on the North by a wide street with 2.40 meters side
walk on each side while the narrower RROW is bounded by a 1.80
meter side walk on each side. To the east of the site is
another garments factory and to its west is a plastic factory.
Across the wider street is a newly-built shoe factory. The rear side of
the lot faces a tire factory.

The following development controls apply to the project site:

1. Zoning Classification is a I-2 (Industrial Two)- a medium industrial


use or occupancy,
2. Base on the NCBP 2005 Revised Implementing Rules and
Regulations (R-IRR)

The project site has the following development limitations:

1. The prescribed minimum setbacks at ground floor are 00 meters at


front and 3.0 meter at sides and rear.
2. A building Height Limit (BHL) of 21.00 meters but not exceed the
duly-approved BHL in the major zone it is part of
3. A minimum required parking of 1 bus slot for every 100 workers, 1
loading slot for articulated truck, and 1 loading slot for a standard
truck
4. Provide truck maneuvering area outside the RROW (with in property
lines only).

The Stated Project requirements are as follows:

https://tip.instructure.com/courses/29639/quizzes/428764 61/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

1. Administration (Two floors)


2. Reception Room
3. Executive area
4. Department Office
5. Conference Room
6. Toilets
7. Employees Facilities ( Ground Floor)
8. Cafeteria
9. Quite Lounges
10. Recreation Area
11. Factory Men’s & Women’s Lockers & Toilet
12. Office Men’s & Women’s Lockers & Toilet
13. Meeting Rooms
14. First Aid Clinic
15. Operations & Maintenance
16. Manufacturing Area
17. Warehousing Area/ Truck Loading Area
18. Utilities
19. Generator Room
20. Domestic Water Cistern
21. Overhead Water
22. Pump Room
23. Solid Waste Storage

 
18.60 sq. m

ou Answered  
27.90 sq. m

orrect answer  
9.30 sq. m

 
37.20 sq. m

Question 76 0
/ 1 pts

https://tip.instructure.com/courses/29639/quizzes/428764 62/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

Q: The Architect has decided that the garments factory shall face the
21.00m wide street. If you are the Architect, where will you place the
Administration Department & employee’s facilities on the plan base on
orientation?

-----------

PROJECT #2: GARMENTS FACTORY

A multi-national company, Far East Garments Manufacturing Inc. (The


Client), has decided to expand its operation in Asia and put up
a GARMENTS FACTORY (The Project) in an Industrial Area at the Subic
Freeport, Olongapo City, Zambales. The factory shall be erected in
a through-lot a Total Lot Area (TLA) of 5,000.00 sq. m. The lot’s 50
meters wide frontage faces north and bounded by a 21.00 meters wide
street. The rear lot faces South on an 18.00 meters wide road right of
way. The rectangular lot which has a depth of 100.00 meters has a
moderate slope of 4 % towards the narrower street.

The Garments Factory is envisioned to be one of the most modern


manufacturing plants in Asia having its aim of providing service to the big
name brands in clothing industry. The major stock holder of the company
is a known environmentalist thus they have hired an Architect who is also
a known practitioner of Green Architecture.

The site bounded on the North by a wide street with 2.40 meters side
walk on each side while the narrower RROW is bounded by a 1.80
meter side walk on each side. To the east of the site is
another garments factory and to its west is a plastic factory.
Across the wider street is a newly-built shoe factory. The rear side of
the lot faces a tire factory.

The following development controls apply to the project site:

1. Zoning Classification is a I-2 (Industrial Two)- a medium industrial


use or occupancy,
2. Base on the NCBP 2005 Revised Implementing Rules and
Regulations (R-IRR)

The project site has the following development limitations:

https://tip.instructure.com/courses/29639/quizzes/428764 63/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

1. The prescribed minimum setbacks at ground floor are 00 meters at


front and 3.0 meter at sides and rear.
2. A building Height Limit (BHL) of 21.00 meters but not exceed the
duly-approved BHL in the major zone it is part of
3. A minimum required parking of 1 bus slot for every 100 workers, 1
loading slot for articulated truck, and 1 loading slot for a standard
truck
4. Provide truck maneuvering area outside the RROW (with in property
lines only).

The Stated Project requirements are as follows:

1. Administration (Two floors)


2. Reception Room
3. Executive area
4. Department Office
5. Conference Room
6. Toilets
7. Employees Facilities ( Ground Floor)
8. Cafeteria
9. Quite Lounges
10. Recreation Area
11. Factory Men’s & Women’s Lockers & Toilet
12. Office Men’s & Women’s Lockers & Toilet
13. Meeting Rooms
14. First Aid Clinic
15. Operations & Maintenance
16. Manufacturing Area
17. Warehousing Area/ Truck Loading Area
18. Utilities
19. Generator Room
20. Domestic Water Cistern
21. Overhead Water
22. Pump Room
23. Solid Waste Storage

ou Answered  
South

https://tip.instructure.com/courses/29639/quizzes/428764 64/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

orrect answer  
North

 
West

 
East

Question 77 0
/ 1 pts

Q:

This garments factory has an industrial 2 or I-2 zoning classification.


Under suggested minimum lot size of rule VIII, what is the minimum lot
size of a through lot of industrial-2 zoning?

---------

PROJECT #2: GARMENTS FACTORY

A multi-national company, Far East Garments Manufacturing Inc. (The


Client), has decided to expand its operation in Asia and put up
a GARMENTS FACTORY (The Project) in an Industrial Area at the Subic
Freeport, Olongapo City, Zambales. The factory shall be erected in
a through-lot a Total Lot Area (TLA) of 5,000.00 sq. m. The lot’s 50
meters wide frontage faces north and bounded by a 21.00 meters wide
street. The rear lot faces South on an 18.00 meters wide road right of
way. The rectangular lot which has a depth of 100.00 meters has a
moderate slope of 4 % towards the narrower street.

The Garments Factory is envisioned to be one of the most modern


manufacturing plants in Asia having its aim of providing service to the big
name brands in clothing industry. The major stock holder of the company
is a known environmentalist thus they have hired an Architect who is also
a known practitioner of Green Architecture.

The site bounded on the North by a wide street with 2.40 meters side
walk on each side while the narrower RROW is bounded by a 1.80
meter side walk on each side. To the east of the site is
another garments factory and to its west is a plastic factory.

https://tip.instructure.com/courses/29639/quizzes/428764 65/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

Across the wider street is a newly-built shoe factory. The rear side of


the lot faces a tire factory.

The following development controls apply to the project site:

1. Zoning Classification is a I-2 (Industrial Two)- a medium industrial


use or occupancy,
2. Base on the NCBP 2005 Revised Implementing Rules and
Regulations (R-IRR)

The project site has the following development limitations:

1. The prescribed minimum setbacks at ground floor are 00 meters at


front and 3.0 meter at sides and rear.
2. A building Height Limit (BHL) of 21.00 meters but not exceed the
duly-approved BHL in the major zone it is part of
3. A minimum required parking of 1 bus slot for every 100 workers, 1
loading slot for articulated truck, and 1 loading slot for a standard
truck
4. Provide truck maneuvering area outside the RROW (with in property
lines only).

The Stated Project requirements are as follows:

1. Administration (Two floors)


2. Reception Room
3. Executive area
4. Department Office
5. Conference Room
6. Toilets
7. Employees Facilities ( Ground Floor)
8. Cafeteria
9. Quite Lounges
10. Recreation Area
11. Factory Men’s & Women’s Lockers & Toilet
12. Office Men’s & Women’s Lockers & Toilet
13. Meeting Rooms
14. First Aid Clinic
15. Operations & Maintenance
16. Manufacturing Area

https://tip.instructure.com/courses/29639/quizzes/428764 66/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

17. Warehousing Area/ Truck Loading Area


18. Utilities
19. Generator Room
20. Domestic Water Cistern
21. Overhead Water
22. Pump Room
23. Solid Waste Stora

ou Answered  
365 sq. m

 
238 sq. m

orrect answer  
813 sq. m

 
540 sq. m

Question 78 1
/ 1 pts

Q:This garments factory has several offices. What is the unit area per
occupant of an office?

-----------

PROJECT #2: GARMENTS FACTORY

A multi-national company, Far East Garments Manufacturing Inc. (The


Client), has decided to expand its operation in Asia and put up
a GARMENTS FACTORY (The Project) in an Industrial Area at the Subic
Freeport, Olongapo City, Zambales. The factory shall be erected in
a through-lot a Total Lot Area (TLA) of 5,000.00 sq. m. The lot’s 50
meters wide frontage faces north and bounded by a 21.00 meters wide
street. The rear lot faces South on an 18.00 meters wide road right of
way. The rectangular lot which has a depth of 100.00 meters has a
moderate slope of 4 % towards the narrower street.

The Garments Factory is envisioned to be one of the most modern


manufacturing plants in Asia having its aim of providing service to the big

https://tip.instructure.com/courses/29639/quizzes/428764 67/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

name brands in clothing industry. The major stock holder of the company
is a known environmentalist thus they have hired an Architect who is also
a known practitioner of Green Architecture.

The site bounded on the North by a wide street with 2.40 meters side
walk on each side while the narrower RROW is bounded by a 1.80
meter side walk on each side. To the east of the site is
another garments factory and to its west is a plastic factory.
Across the wider street is a newly-built shoe factory. The rear side of
the lot faces a tire factory.

The following development controls apply to the project site:

1. Zoning Classification is a I-2 (Industrial Two)- a medium industrial


use or occupancy,
2. Base on the NCBP 2005 Revised Implementing Rules and
Regulations (R-IRR)

The project site has the following development limitations:

1. The prescribed minimum setbacks at ground floor are 00 meters at


front and 3.0 meter at sides and rear.
2. A building Height Limit (BHL) of 21.00 meters but not exceed the
duly-approved BHL in the major zone it is part of
3. A minimum required parking of 1 bus slot for every 100 workers, 1
loading slot for articulated truck, and 1 loading slot for a standard
truck
4. Provide truck maneuvering area outside the RROW (with in property
lines only).

The Stated Project requirements are as follows:

1. Administration (Two floors)


2. Reception Room
3. Executive area
4. Department Office
5. Conference Room
6. Toilets
7. Employees Facilities ( Ground Floor)
8. Cafeteria
9. Quite Lounges
https://tip.instructure.com/courses/29639/quizzes/428764 68/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

10. Recreation Area


11. Factory Men’s & Women’s Lockers & Toilet
12. Office Men’s & Women’s Lockers & Toilet
13. Meeting Rooms
14. First Aid Clinic
15. Operations & Maintenance
16. Manufacturing Area
17. Warehousing Area/ Truck Loading Area
18. Utilities
19. Generator Room
20. Domestic Water Cistern
21. Overhead Water
22. Pump Room
23. Solid Waste Storage

 
18.60 sq. m

 
1.80 sq. m

 
1.40 sq. m

Correct!  
9.30 sq. m

Question 79 1
/ 1 pts

Q: Dropped curbs shall be ramped toward adjoining curbs with a gradient


or slope not more than______?

-----------

PROJECT #2: GARMENTS FACTORY

A multi-national company, Far East Garments Manufacturing Inc. (The


Client), has decided to expand its operation in Asia and put up a
GARMENTS FACTORY (The Project) in an Industrial Area at the Subic
Freeport, Olongapo City, Zambales. The factory shall be erected in a
through-lot a Total Lot Area (TLA) of 5,000.00 sq. m. The lot’s 50

https://tip.instructure.com/courses/29639/quizzes/428764 69/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

meters wide frontage faces north and bounded by a 21.00 meters wide
street. The rear lot faces South on an 18.00 meters wide road right of
way. The rectangular lot which has a depth of 100.00 meters has a
moderate slope of 4 % towards the narrower street.

The Garments Factory is envisioned to be one of the most modern


manufacturing plants in Asia having its aim of providing service to the big
name brands in clothing industry. The major stock holder of the company
is a known environmentalist thus they have hired an Architect who is also
a known practitioner of Green Architecture.

The site bounded on the North by a wide street with 2.40 meters side
walk on each side while the narrower RROW is bounded by a 1.80
meter side walk on each side. To the east of the site is another
garments factory and to its west is a plastic factory. Across the wider
street is a newly-built shoe factory. The rear side of the lot faces a tire
factory.

The following development controls apply to the project site:

1. Zoning Classification is a I-2 (Industrial Two)- a medium industrial


use or occupancy,
2. Base on the NCBP 2005 Revised Implementing Rules and
Regulations (R-IRR)

The project site has the following development limitations:

1. The prescribed minimum setbacks at ground floor are 00 meters at


front and 3.0 meter at sides and rear.
2. A building Height Limit (BHL) of 21.00 meters but not exceed the
duly-approved BHL in the major zone it is part of
3. A minimum required parking of 1 bus slot for every 100 workers, 1
loading slot for articulated truck, and 1 loading slot for a standard
truck
4. Provide truck maneuvering area outside the RROW (with in property
lines only).

The Stated Project requirements are as follows:

1. Administration (Two floors)


2. Reception Room

https://tip.instructure.com/courses/29639/quizzes/428764 70/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

3. Executive area
4. Department Office
5. Conference Room
6. Toilets
7. Employees Facilities ( Ground Floor)
8. Cafeteria
9. Quite Lounges
10. Recreation Area
11. Factory Men’s & Women’s Lockers & Toilet
12. Office Men’s & Women’s Lockers & Toilet
13. Meeting Rooms
14. First Aid Clinic
15. Operations & Maintenance
16. Manufacturing Area
17. Warehousing Area/ Truck Loading Area
18. Utilities
19. Generator Room
20. Domestic Water Cistern
21. Overhead Water
22. Pump Room
23. Solid Waste Storage

 
1:10

 
1:8

Correct!  
1:12

 
1:5

Question 80 0
/ 1 pts

https://tip.instructure.com/courses/29639/quizzes/428764 71/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

Q:

What is the Maximum Allowable Paved Open Spaces (ISA) of this


project?

---------

PROJECT #2: GARMENTS FACTORY

A multi-national company, Far East Garments Manufacturing Inc. (The


Client), has decided to expand its operation in Asia and put up
a GARMENTS FACTORY (The Project) in an Industrial Area at the Subic
Freeport, Olongapo City, Zambales. The factory shall be erected in
a through-lot a Total Lot Area (TLA) of 5,000.00 sq. m. The lot’s 50
meters wide frontage faces north and bounded by a 21.00 meters wide
street. The rear lot faces South on an 18.00 meters wide road right of
way. The rectangular lot which has a depth of 100.00 meters has a
moderate slope of 4 % towards the narrower street.

The Garments Factory is envisioned to be one of the most modern


manufacturing plants in Asia having its aim of providing service to the big
name brands in clothing industry. The major stock holder of the company
is a known environmentalist thus they have hired an Architect who is also
a known practitioner of Green Architecture.

The site bounded on the North by a wide street with 2.40 meters side
walk on each side while the narrower RROW is bounded by a 1.80
meter side walk on each side. To the east of the site is
another garments factory and to its west is a plastic factory.
Across the wider street is a newly-built shoe factory. The rear side of
the lot faces a tire factory.

The following development controls apply to the project site:

1. Zoning Classification is a I-2 (Industrial Two)- a medium industrial


use or occupancy,
2. Base on the NCBP 2005 Revised Implementing Rules and
Regulations (R-IRR)

The project site has the following development limitations:

https://tip.instructure.com/courses/29639/quizzes/428764 72/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

1. The prescribed minimum setbacks at ground floor are 00 meters at


front and 3.0 meter at sides and rear.
2. A building Height Limit (BHL) of 21.00 meters but not exceed the
duly-approved BHL in the major zone it is part of
3. A minimum required parking of 1 bus slot for every 100 workers, 1
loading slot for articulated truck, and 1 loading slot for a standard
truck
4. Provide truck maneuvering area outside the RROW (with in property
lines only).

The Stated Project requirements are as follows:

1. Administration (Two floors)


2. Reception Room
3. Executive area
4. Department Office
5. Conference Room
6. Toilets
7. Employees Facilities ( Ground Floor)
8. Cafeteria
9. Quite Lounges
10. Recreation Area
11. Factory Men’s & Women’s Lockers & Toilet
12. Office Men’s & Women’s Lockers & Toilet
13. Meeting Rooms
14. First Aid Clinic
15. Operations & Maintenance
16. Manufacturing Area
17. Warehousing Area/ Truck Loading Area
18. Utilities
19. Generator Room
20. Domestic Water Cistern
21. Overhead Water
22. Pump Room
23. Solid Waste Stora

orrect answer  
20%

 
10%

https://tip.instructure.com/courses/29639/quizzes/428764 73/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

ou Answered  
15%

 
5%

Question 81 0
/ 1 pts

Q:

60. The total lot area of this project is 5000 sq. m. How much is the
maximum area of tiled and hard caped areas?

---------

PROJECT #2: GARMENTS FACTORY

A multi-national company, Far East Garments Manufacturing Inc. (The


Client), has decided to expand its operation in Asia and put up
a GARMENTS FACTORY (The Project) in an Industrial Area at the Subic
Freeport, Olongapo City, Zambales. The factory shall be erected in
a through-lot a Total Lot Area (TLA) of 5,000.00 sq. m. The lot’s 50
meters wide frontage faces north and bounded by a 21.00 meters wide
street. The rear lot faces South on an 18.00 meters wide road right of
way. The rectangular lot which has a depth of 100.00 meters has a
moderate slope of 4 % towards the narrower street.

The Garments Factory is envisioned to be one of the most modern


manufacturing plants in Asia having its aim of providing service to the big
name brands in clothing industry. The major stock holder of the company
is a known environmentalist thus they have hired an Architect who is also
a known practitioner of Green Architecture.

The site bounded on the North by a wide street with 2.40 meters side
walk on each side while the narrower RROW is bounded by a 1.80
meter side walk on each side. To the east of the site is
another garments factory and to its west is a plastic factory.
Across the wider street is a newly-built shoe factory. The rear side of
the lot faces a tire factory.

The following development controls apply to the project site:

https://tip.instructure.com/courses/29639/quizzes/428764 74/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

1. Zoning Classification is a I-2 (Industrial Two)- a medium industrial


use or occupancy,
2. Base on the NCBP 2005 Revised Implementing Rules and
Regulations (R-IRR)

The project site has the following development limitations:

1. The prescribed minimum setbacks at ground floor are 00 meters at


front and 3.0 meter at sides and rear.
2. A building Height Limit (BHL) of 21.00 meters but not exceed the
duly-approved BHL in the major zone it is part of
3. A minimum required parking of 1 bus slot for every 100 workers, 1
loading slot for articulated truck, and 1 loading slot for a standard
truck
4. Provide truck maneuvering area outside the RROW (with in property
lines only).

The Stated Project requirements are as follows:

1. Administration (Two floors)


2. Reception Room
3. Executive area
4. Department Office
5. Conference Room
6. Toilets
7. Employees Facilities ( Ground Floor)
8. Cafeteria
9. Quite Lounges
10. Recreation Area
11. Factory Men’s & Women’s Lockers & Toilet
12. Office Men’s & Women’s Lockers & Toilet
13. Meeting Rooms
14. First Aid Clinic
15. Operations & Maintenance
16. Manufacturing Area
17. Warehousing Area/ Truck Loading Area
18. Utilities
19. Generator Room
20. Domestic Water Cistern

https://tip.instructure.com/courses/29639/quizzes/428764 75/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

21. Overhead Water


22. Pump Room
23. Solid Waste Stora

ou Answered  
250 sqm.

 
750 sqm.

orrect answer  
1,000 sq. m

 
500 sqm.

Question 82 1
/ 1 pts

Q:

What is the occupant load factor of a conference room?

---------

PROJECT #2: GARMENTS FACTORY

A multi-national company, Far East Garments Manufacturing Inc. (The


Client), has decided to expand its operation in Asia and put up
a GARMENTS FACTORY (The Project) in an Industrial Area at the Subic
Freeport, Olongapo City, Zambales. The factory shall be erected in
a through-lot a Total Lot Area (TLA) of 5,000.00 sq. m. The lot’s 50
meters wide frontage faces north and bounded by a 21.00 meters wide
street. The rear lot faces South on an 18.00 meters wide road right of
way. The rectangular lot which has a depth of 100.00 meters has a
moderate slope of 4 % towards the narrower street.

The Garments Factory is envisioned to be one of the most modern


manufacturing plants in Asia having its aim of providing service to the big
name brands in clothing industry. The major stock holder of the company
is a known environmentalist thus they have hired an Architect who is also
a known practitioner of Green Architecture.

https://tip.instructure.com/courses/29639/quizzes/428764 76/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

The site bounded on the North by a wide street with 2.40 meters side
walk on each side while the narrower RROW is bounded by a 1.80
meter side walk on each side. To the east of the site is
another garments factory and to its west is a plastic factory.
Across the wider street is a newly-built shoe factory. The rear side of
the lot faces a tire factory.

The following development controls apply to the project site:

1. Zoning Classification is a I-2 (Industrial Two)- a medium industrial


use or occupancy,
2. Base on the NCBP 2005 Revised Implementing Rules and
Regulations (R-IRR)

The project site has the following development limitations:

1. The prescribed minimum setbacks at ground floor are 00 meters at


front and 3.0 meter at sides and rear.
2. A building Height Limit (BHL) of 21.00 meters but not exceed the
duly-approved BHL in the major zone it is part of
3. A minimum required parking of 1 bus slot for every 100 workers, 1
loading slot for articulated truck, and 1 loading slot for a standard
truck
4. Provide truck maneuvering area outside the RROW (with in property
lines only).

The Stated Project requirements are as follows:

1. Administration (Two floors)


2. Reception Room
3. Executive area
4. Department Office
5. Conference Room
6. Toilets
7. Employees Facilities ( Ground Floor)
8. Cafeteria
9. Quite Lounges
10. Recreation Area
11. Factory Men’s & Women’s Lockers & Toilet
12. Office Men’s & Women’s Lockers & Toilet

https://tip.instructure.com/courses/29639/quizzes/428764 77/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

13. Meeting Rooms


14. First Aid Clinic
15. Operations & Maintenance
16. Manufacturing Area
17. Warehousing Area/ Truck Loading Area
18. Utilities
19. Generator Room
20. Domestic Water Cistern
21. Overhead Water
22. Pump Room
23. Solid Waste Stora

 
55.8 sq. m

 
168 sq. m

Correct!  
1.40 sq. m

 
1.80 sq. m

Question 83 0
/ 1 pts

Q:

How wide is the roadway on the southern side?

---------

PROJECT #2: GARMENTS FACTORY

A multi-national company, Far East Garments Manufacturing Inc. (The


Client), has decided to expand its operation in Asia and put up
a GARMENTS FACTORY (The Project) in an Industrial Area at the Subic
Freeport, Olongapo City, Zambales. The factory shall be erected in
a through-lot a Total Lot Area (TLA) of 5,000.00 sq. m. The lot’s 50
meters wide frontage faces north and bounded by a 21.00 meters wide
street. The rear lot faces South on an 18.00 meters wide road right of

https://tip.instructure.com/courses/29639/quizzes/428764 78/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

way. The rectangular lot which has a depth of 100.00 meters has a


moderate slope of 4 % towards the narrower street.

The Garments Factory is envisioned to be one of the most modern


manufacturing plants in Asia having its aim of providing service to the big
name brands in clothing industry. The major stock holder of the company
is a known environmentalist thus they have hired an Architect who is also
a known practitioner of Green Architecture.

The site bounded on the North by a wide street with 2.40 meters side
walk on each side while the narrower RROW is bounded by a 1.80
meter side walk on each side. To the east of the site is
another garments factory and to its west is a plastic factory.
Across the wider street is a newly-built shoe factory. The rear side of
the lot faces a tire factory.

The following development controls apply to the project site:

1. Zoning Classification is a I-2 (Industrial Two)- a medium industrial


use or occupancy,
2. Base on the NCBP 2005 Revised Implementing Rules and
Regulations (R-IRR)

The project site has the following development limitations:

1. The prescribed minimum setbacks at ground floor are 00 meters at


front and 3.0 meter at sides and rear.
2. A building Height Limit (BHL) of 21.00 meters but not exceed the
duly-approved BHL in the major zone it is part of
3. A minimum required parking of 1 bus slot for every 100 workers, 1
loading slot for articulated truck, and 1 loading slot for a standard
truck
4. Provide truck maneuvering area outside the RROW (with in property
lines only).

The Stated Project requirements are as follows:

1. Administration (Two floors)


2. Reception Room
3. Executive area
4. Department Office

https://tip.instructure.com/courses/29639/quizzes/428764 79/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

5. Conference Room
6. Toilets
7. Employees Facilities ( Ground Floor)
8. Cafeteria
9. Quite Lounges
10. Recreation Area
11. Factory Men’s & Women’s Lockers & Toilet
12. Office Men’s & Women’s Lockers & Toilet
13. Meeting Rooms
14. First Aid Clinic
15. Operations & Maintenance
16. Manufacturing Area
17. Warehousing Area/ Truck Loading Area
18. Utilities
19. Generator Room
20. Domestic Water Cistern
21. Overhead Water
22. Pump Room
23. Solid Waste Stora

 
7.20 m

 
10.20 m

ou Answered  
16.20 m

orrect answer  
14.40 m

Question 84 1
/ 1 pts

Q:

How wide is the road right of way on the southern side?

---------

PROJECT #2: GARMENTS FACTORY


https://tip.instructure.com/courses/29639/quizzes/428764 80/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

A multi-national company, Far East Garments Manufacturing Inc. (The


Client), has decided to expand its operation in Asia and put up
a GARMENTS FACTORY (The Project) in an Industrial Area at the Subic
Freeport, Olongapo City, Zambales. The factory shall be erected in
a through-lot a Total Lot Area (TLA) of 5,000.00 sq. m. The lot’s 50
meters wide frontage faces north and bounded by a 21.00 meters wide
street. The rear lot faces South on an 18.00 meters wide road right of
way. The rectangular lot which has a depth of 100.00 meters has a
moderate slope of 4 % towards the narrower street.

The Garments Factory is envisioned to be one of the most modern


manufacturing plants in Asia having its aim of providing service to the big
name brands in clothing industry. The major stock holder of the company
is a known environmentalist thus they have hired an Architect who is also
a known practitioner of Green Architecture.

The site bounded on the North by a wide street with 2.40 meters side
walk on each side while the narrower RROW is bounded by a 1.80
meter side walk on each side. To the east of the site is
another garments factory and to its west is a plastic factory.
Across the wider street is a newly-built shoe factory. The rear side of
the lot faces a tire factory.

The following development controls apply to the project site:

1. Zoning Classification is a I-2 (Industrial Two)- a medium industrial


use or occupancy,
2. Base on the NCBP 2005 Revised Implementing Rules and
Regulations (R-IRR)

The project site has the following development limitations:

1. The prescribed minimum setbacks at ground floor are 00 meters at


front and 3.0 meter at sides and rear.
2. A building Height Limit (BHL) of 21.00 meters but not exceed the
duly-approved BHL in the major zone it is part of
3. A minimum required parking of 1 bus slot for every 100 workers, 1
loading slot for articulated truck, and 1 loading slot for a standard
truck
4. Provide truck maneuvering area outside the RROW (with in property
lines only).

https://tip.instructure.com/courses/29639/quizzes/428764 81/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

The Stated Project requirements are as follows:

1. Administration (Two floors)


2. Reception Room
3. Executive area
4. Department Office
5. Conference Room
6. Toilets
7. Employees Facilities ( Ground Floor)
8. Cafeteria
9. Quite Lounges
10. Recreation Area
11. Factory Men’s & Women’s Lockers & Toilet
12. Office Men’s & Women’s Lockers & Toilet
13. Meeting Rooms
14. First Aid Clinic
15. Operations & Maintenance
16. Manufacturing Area
17. Warehousing Area/ Truck Loading Area
18. Utilities
19. Generator Room
20. Domestic Water Cistern
21. Overhead Water
22. Pump Room
23. Solid Waste Stora

Correct!  
18.00 m

 
17.00 m

 
15.00 m

 
16.00 m

Question 85 1
/ 1 pts

https://tip.instructure.com/courses/29639/quizzes/428764 82/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

Q:

60. What is the Maximum Percentage of Site Occupancy of this project in


sq. m?

---------

PROJECT #2: GARMENTS FACTORY

A multi-national company, Far East Garments Manufacturing Inc. (The


Client), has decided to expand its operation in Asia and put up
a GARMENTS FACTORY (The Project) in an Industrial Area at the Subic
Freeport, Olongapo City, Zambales. The factory shall be erected in
a through-lot a Total Lot Area (TLA) of 5,000.00 sq. m. The lot’s 50
meters wide frontage faces north and bounded by a 21.00 meters wide
street. The rear lot faces South on an 18.00 meters wide road right of
way. The rectangular lot which has a depth of 100.00 meters has a
moderate slope of 4 % towards the narrower street.

The Garments Factory is envisioned to be one of the most modern


manufacturing plants in Asia having its aim of providing service to the big
name brands in clothing industry. The major stock holder of the company
is a known environmentalist thus they have hired an Architect who is also
a known practitioner of Green Architecture.

The site bounded on the North by a wide street with 2.40 meters side
walk on each side while the narrower RROW is bounded by a 1.80
meter side walk on each side. To the east of the site is
another garments factory and to its west is a plastic factory.
Across the wider street is a newly-built shoe factory. The rear side of
the lot faces a tire factory.

The following development controls apply to the project site:

1. Zoning Classification is a I-2 (Industrial Two)- a medium industrial


use or occupancy,
2. Base on the NCBP 2005 Revised Implementing Rules and
Regulations (R-IRR)

The project site has the following development limitations:

1. The prescribed minimum setbacks at ground floor are 00 meters at


front and 3.0 meter at sides and rear.

https://tip.instructure.com/courses/29639/quizzes/428764 83/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

2. A building Height Limit (BHL) of 21.00 meters but not exceed the


duly-approved BHL in the major zone it is part of
3. A minimum required parking of 1 bus slot for every 100 workers, 1
loading slot for articulated truck, and 1 loading slot for a standard
truck
4. Provide truck maneuvering area outside the RROW (with in property
lines only).

The Stated Project requirements are as follows:

1. Administration (Two floors)


2. Reception Room
3. Executive area
4. Department Office
5. Conference Room
6. Toilets
7. Employees Facilities ( Ground Floor)
8. Cafeteria
9. Quite Lounges
10. Recreation Area
11. Factory Men’s & Women’s Lockers & Toilet
12. Office Men’s & Women’s Lockers & Toilet
13. Meeting Rooms
14. First Aid Clinic
15. Operations & Maintenance
16. Manufacturing Area
17. Warehousing Area/ Truck Loading Area
18. Utilities
19. Generator Room
20. Domestic Water Cistern
21. Overhead Water
22. Pump Room
23. Solid Waste Stora

Correct!  
3,500 sq. m

 
4,000 sq. m

 
3,000 sq. m

https://tip.instructure.com/courses/29639/quizzes/428764 84/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

 
2,500 sq. m.

Question 86 1
/ 1 pts

Q: Handrails attached to the walls should have a clearance not less than
____ from the wall?

-----------

PROJECT #2: GARMENTS FACTORY

A multi-national company, Far East Garments Manufacturing Inc. (The


Client), has decided to expand its operation in Asia and put up a
GARMENTS FACTORY (The Project) in an Industrial Area at the Subic
Freeport, Olongapo City, Zambales. The factory shall be erected in a
through-lot a Total Lot Area (TLA) of 5,000.00 sq. m. The lot’s 50
meters wide frontage faces north and bounded by a 21.00 meters wide
street. The rear lot faces South on an 18.00 meters wide road right of
way. The rectangular lot which has a depth of 100.00 meters has a
moderate slope of 4 % towards the narrower street.

The Garments Factory is envisioned to be one of the most modern


manufacturing plants in Asia having its aim of providing service to the big
name brands in clothing industry. The major stock holder of the company
is a known environmentalist thus they have hired an Architect who is also
a known practitioner of Green Architecture.

The site bounded on the North by a wide street with 2.40 meters side
walk on each side while the narrower RROW is bounded by a 1.80
meter side walk on each side. To the east of the site is another
garments factory and to its west is a plastic factory. Across the wider
street is a newly-built shoe factory. The rear side of the lot faces a tire
factory.

The following development controls apply to the project site:

1. Zoning Classification is a I-2 (Industrial Two)- a medium industrial


use or occupancy,
https://tip.instructure.com/courses/29639/quizzes/428764 85/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

2. Base on the NCBP 2005 Revised Implementing Rules and


Regulations (R-IRR)

The project site has the following development limitations:

1. The prescribed minimum setbacks at ground floor are 00 meters at


front and 3.0 meter at sides and rear.
2. A building Height Limit (BHL) of 21.00 meters but not exceed the
duly-approved BHL in the major zone it is part of
3. A minimum required parking of 1 bus slot for every 100 workers, 1
loading slot for articulated truck, and 1 loading slot for a standard
truck
4. Provide truck maneuvering area outside the RROW (with in property
lines only).

The Stated Project requirements are as follows:

1. Administration (Two floors)


2. Reception Room
3. Executive area
4. Department Office
5. Conference Room
6. Toilets
7. Employees Facilities ( Ground Floor)
8. Cafeteria
9. Quite Lounges
10. Recreation Area
11. Factory Men’s & Women’s Lockers & Toilet
12. Office Men’s & Women’s Lockers & Toilet
13. Meeting Rooms
14. First Aid Clinic
15. Operations & Maintenance
16. Manufacturing Area
17. Warehousing Area/ Truck Loading Area
18. Utilities
19. Generator Room
20. Domestic Water Cistern
21. Overhead Water
22. Pump Room

https://tip.instructure.com/courses/29639/quizzes/428764 86/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

23. Solid Waste Storage

 
60mm

Correct!  
50mm

 
70mm

 
80mmm

Question 87 1
/ 1 pts

Q:

The total lot area of this project is 5000 sq. m. How much is the minimum
area of the lot with exposed soil and soft-scaping?

---------

PROJECT #2: GARMENTS FACTORY

A multi-national company, Far East Garments Manufacturing Inc. (The


Client), has decided to expand its operation in Asia and put up
a GARMENTS FACTORY (The Project) in an Industrial Area at the Subic
Freeport, Olongapo City, Zambales. The factory shall be erected in
a through-lot a Total Lot Area (TLA) of 5,000.00 sq. m. The lot’s 50
meters wide frontage faces north and bounded by a 21.00 meters wide
street. The rear lot faces South on an 18.00 meters wide road right of
way. The rectangular lot which has a depth of 100.00 meters has a
moderate slope of 4 % towards the narrower street.

The Garments Factory is envisioned to be one of the most modern


manufacturing plants in Asia having its aim of providing service to the big
name brands in clothing industry. The major stock holder of the company

https://tip.instructure.com/courses/29639/quizzes/428764 87/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

is a known environmentalist thus they have hired an Architect who is also


a known practitioner of Green Architecture.

The site bounded on the North by a wide street with 2.40 meters side
walk on each side while the narrower RROW is bounded by a 1.80
meter side walk on each side. To the east of the site is
another garments factory and to its west is a plastic factory.
Across the wider street is a newly-built shoe factory. The rear side of
the lot faces a tire factory.

The following development controls apply to the project site:

1. Zoning Classification is a I-2 (Industrial Two)- a medium industrial


use or occupancy,
2. Base on the NCBP 2005 Revised Implementing Rules and
Regulations (R-IRR)

The project site has the following development limitations:

1. The prescribed minimum setbacks at ground floor are 00 meters at


front and 3.0 meter at sides and rear.
2. A building Height Limit (BHL) of 21.00 meters but not exceed the
duly-approved BHL in the major zone it is part of
3. A minimum required parking of 1 bus slot for every 100 workers, 1
loading slot for articulated truck, and 1 loading slot for a standard
truck
4. Provide truck maneuvering area outside the RROW (with in property
lines only).

The Stated Project requirements are as follows:

1. Administration (Two floors)


2. Reception Room
3. Executive area
4. Department Office
5. Conference Room
6. Toilets
7. Employees Facilities ( Ground Floor)
8. Cafeteria
9. Quite Lounges
10. Recreation Area
https://tip.instructure.com/courses/29639/quizzes/428764 88/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

11. Factory Men’s & Women’s Lockers & Toilet


12. Office Men’s & Women’s Lockers & Toilet
13. Meeting Rooms
14. First Aid Clinic
15. Operations & Maintenance
16. Manufacturing Area
17. Warehousing Area/ Truck Loading Area
18. Utilities
19. Generator Room
20. Domestic Water Cistern
21. Overhead Water
22. Pump Room
23. Solid Waste Stora

 
250 sq. m

 
750 sq. m

Correct!  
500 sq. m

 
1,000 sq. m

Question 88 1
/ 1 pts

Q: Corridors where disabled persons will pass through shall have a


minimum clearance width of _______

-----------

PROJECT #2: GARMENTS FACTORY

A multi-national company, Far East Garments Manufacturing Inc. (The


Client), has decided to expand its operation in Asia and put up
a GARMENTS FACTORY (The Project) in an Industrial Area at the Subic
Freeport, Olongapo City, Zambales. The factory shall be erected in
a through-lot a Total Lot Area (TLA) of 5,000.00 sq. m. The lot’s 50
meters wide frontage faces north and bounded by a 21.00 meters wide

https://tip.instructure.com/courses/29639/quizzes/428764 89/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

street. The rear lot faces South on an 18.00 meters wide road right of
way. The rectangular lot which has a depth of 100.00 meters has a
moderate slope of 4 % towards the narrower street.

The Garments Factory is envisioned to be one of the most modern


manufacturing plants in Asia having its aim of providing service to the big
name brands in clothing industry. The major stock holder of the company
is a known environmentalist thus they have hired an Architect who is also
a known practitioner of Green Architecture.

The site bounded on the North by a wide street with 2.40 meters side
walk on each side while the narrower RROW is bounded by a 1.80
meter side walk on each side. To the east of the site is
another garments factory and to its west is a plastic factory.
Across the wider street is a newly-built shoe factory. The rear side of
the lot faces a tire factory.

The following development controls apply to the project site:

1. Zoning Classification is a I-2 (Industrial Two)- a medium industrial


use or occupancy,
2. Base on the NCBP 2005 Revised Implementing Rules and
Regulations (R-IRR)

The project site has the following development limitations:

1. The prescribed minimum setbacks at ground floor are 00 meters at


front and 3.0 meter at sides and rear.
2. A building Height Limit (BHL) of 21.00 meters but not exceed the
duly-approved BHL in the major zone it is part of
3. A minimum required parking of 1 bus slot for every 100 workers, 1
loading slot for articulated truck, and 1 loading slot for a standard
truck
4. Provide truck maneuvering area outside the RROW (with in property
lines only).

The Stated Project requirements are as follows:

1. Administration (Two floors)


2. Reception Room
3. Executive area

https://tip.instructure.com/courses/29639/quizzes/428764 90/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

4. Department Office
5. Conference Room
6. Toilets
7. Employees Facilities ( Ground Floor)
8. Cafeteria
9. Quite Lounges
10. Recreation Area
11. Factory Men’s & Women’s Lockers & Toilet
12. Office Men’s & Women’s Lockers & Toilet
13. Meeting Rooms
14. First Aid Clinic
15. Operations & Maintenance
16. Manufacturing Area
17. Warehousing Area/ Truck Loading Area
18. Utilities
19. Generator Room
20. Domestic Water Cistern
21. Overhead Water
22. Pump Room
23. Solid Waste Storage

 
1.10m

Correct!  
1.20m

 
1.00m

 
1.50m

Question 89 1
/ 1 pts

Q:

Based on the correct answer 159, where will you position the glazed
portion of this roof? Remember that Green Architecture must be practiced
in this garments factory.

https://tip.instructure.com/courses/29639/quizzes/428764 91/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

---------

PROJECT #2: GARMENTS FACTORY

A multi-national company, Far East Garments Manufacturing Inc. (The


Client), has decided to expand its operation in Asia and put up
a GARMENTS FACTORY (The Project) in an Industrial Area at the Subic
Freeport, Olongapo City, Zambales. The factory shall be erected in
a through-lot a Total Lot Area (TLA) of 5,000.00 sq. m. The lot’s 50
meters wide frontage faces north and bounded by a 21.00 meters wide
street. The rear lot faces South on an 18.00 meters wide road right of
way. The rectangular lot which has a depth of 100.00 meters has a
moderate slope of 4 % towards the narrower street.

The Garments Factory is envisioned to be one of the most modern


manufacturing plants in Asia having its aim of providing service to the big
name brands in clothing industry. The major stock holder of the company
is a known environmentalist thus they have hired an Architect who is also
a known practitioner of Green Architecture.

The site bounded on the North by a wide street with 2.40 meters side
walk on each side while the narrower RROW is bounded by a 1.80
meter side walk on each side. To the east of the site is
another garments factory and to its west is a plastic factory.
Across the wider street is a newly-built shoe factory. The rear side of
the lot faces a tire factory.

The following development controls apply to the project site:

1. Zoning Classification is a I-2 (Industrial Two)- a medium industrial


use or occupancy,
2. Base on the NCBP 2005 Revised Implementing Rules and
Regulations (R-IRR)

The project site has the following development limitations:

1. The prescribed minimum setbacks at ground floor are 00 meters at


front and 3.0 meter at sides and rear.
2. A building Height Limit (BHL) of 21.00 meters but not exceed the
duly-approved BHL in the major zone it is part of
3. A minimum required parking of 1 bus slot for every 100 workers, 1
loading slot for articulated truck, and 1 loading slot for a standard
truck
https://tip.instructure.com/courses/29639/quizzes/428764 92/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

4. Provide truck maneuvering area outside the RROW (with in property


lines only).

The Stated Project requirements are as follows:

1. Administration (Two floors)


2. Reception Room
3. Executive area
4. Department Office
5. Conference Room
6. Toilets
7. Employees Facilities ( Ground Floor)
8. Cafeteria
9. Quite Lounges
10. Recreation Area
11. Factory Men’s & Women’s Lockers & Toilet
12. Office Men’s & Women’s Lockers & Toilet
13. Meeting Rooms
14. First Aid Clinic
15. Operations & Maintenance
16. Manufacturing Area
17. Warehousing Area/ Truck Loading Area
18. Utilities
19. Generator Room
20. Domestic Water Cistern
21. Overhead Water
22. Pump Room
23. Solid Waste Stora

Correct!  
Towards North

 
Towards east

 
Towards west

 
Towards South

https://tip.instructure.com/courses/29639/quizzes/428764 93/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

Question 90 0
/ 1 pts

Q: According to Time-Saver Standards for Building Types, what is the


minimum standard space that the space planner could give to the
President of a garment factory like this?

--------------

PROJECT #2: GARMENTS FACTORY

A multi-national company, Far East Garments Manufacturing Inc. (The


Client), has decided to expand its operation in Asia and put up
a GARMENTS FACTORY (The Project) in an Industrial Area at the Subic
Freeport, Olongapo City, Zambales. The factory shall be erected in
a through-lot a Total Lot Area (TLA) of 5,000.00 sq. m. The lot’s 50
meters wide frontage faces north and bounded by a 21.00 meters wide
street. The rear lot faces South on an 18.00 meters wide road right of
way. The rectangular lot which has a depth of 100.00 meters has a
moderate slope of 4 % towards the narrower street.

The Garments Factory is envisioned to be one of the most modern


manufacturing plants in Asia having its aim of providing service to the big
name brands in clothing industry. The major stock holder of the company
is a known environmentalist thus they have hired an Architect who is also
a known practitioner of Green Architecture.

The site bounded on the North by a wide street with 2.40 meters side
walk on each side while the narrower RROW is bounded by a 1.80
meter side walk on each side. To the east of the site is
another garments factory and to its west is a plastic factory.
Across the wider street is a newly-built shoe factory. The rear side of
the lot faces a tire factory.

The following development controls apply to the project site:

1. Zoning Classification is a I-2 (Industrial Two)- a medium industrial


use or occupancy,
2. Base on the NCBP 2005 Revised Implementing Rules and
Regulations (R-IRR)

https://tip.instructure.com/courses/29639/quizzes/428764 94/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

The project site has the following development limitations:

1. The prescribed minimum setbacks at ground floor are 00 meters at


front and 3.0 meter at sides and rear.
2. A building Height Limit (BHL) of 21.00 meters but not exceed the
duly-approved BHL in the major zone it is part of
3. A minimum required parking of 1 bus slot for every 100 workers, 1
loading slot for articulated truck, and 1 loading slot for a standard
truck
4. Provide truck maneuvering area outside the RROW (with in property
lines only).

The Stated Project requirements are as follows:

1. Administration (Two floors)


2. Reception Room
3. Executive area
4. Department Office
5. Conference Room
6. Toilets
7. Employees Facilities ( Ground Floor)
8. Cafeteria
9. Quite Lounges
10. Recreation Area
11. Factory Men’s & Women’s Lockers & Toilet
12. Office Men’s & Women’s Lockers & Toilet
13. Meeting Rooms
14. First Aid Clinic
15. Operations & Maintenance
16. Manufacturing Area
17. Warehousing Area/ Truck Loading Area
18. Utilities
19. Generator Room
20. Domestic Water Cistern
21. Overhead Water
22. Pump Room
23. Solid Waste Storage

 
18.60 sq. m

https://tip.instructure.com/courses/29639/quizzes/428764 95/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

 
9.30 sum

orrect answer  
90 sq. m

ou Answered  
37.20 sq. m

Question 91 1
/ 1 pts

Q:

If there are 15 people who will occupy the conference room of this
garments factory, how much minimum space will you allot?

---------

PROJECT #2: GARMENTS FACTORY

A multi-national company, Far East Garments Manufacturing Inc. (The


Client), has decided to expand its operation in Asia and put up
a GARMENTS FACTORY (The Project) in an Industrial Area at the Subic
Freeport, Olongapo City, Zambales. The factory shall be erected in
a through-lot a Total Lot Area (TLA) of 5,000.00 sq. m. The lot’s 50
meters wide frontage faces north and bounded by a 21.00 meters wide
street. The rear lot faces South on an 18.00 meters wide road right of
way. The rectangular lot which has a depth of 100.00 meters has a
moderate slope of 4 % towards the narrower street.

The Garments Factory is envisioned to be one of the most modern


manufacturing plants in Asia having its aim of providing service to the big
name brands in clothing industry. The major stock holder of the company
is a known environmentalist thus they have hired an Architect who is also
a known practitioner of Green Architecture.

The site bounded on the North by a wide street with 2.40 meters side
walk on each side while the narrower RROW is bounded by a 1.80
meter side walk on each side. To the east of the site is
another garments factory and to its west is a plastic factory.

https://tip.instructure.com/courses/29639/quizzes/428764 96/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

Across the wider street is a newly-built shoe factory. The rear side of


the lot faces a tire factory.

The following development controls apply to the project site:

1. Zoning Classification is a I-2 (Industrial Two)- a medium industrial


use or occupancy,
2. Base on the NCBP 2005 Revised Implementing Rules and
Regulations (R-IRR)

The project site has the following development limitations:

1. The prescribed minimum setbacks at ground floor are 00 meters at


front and 3.0 meter at sides and rear.
2. A building Height Limit (BHL) of 21.00 meters but not exceed the
duly-approved BHL in the major zone it is part of
3. A minimum required parking of 1 bus slot for every 100 workers, 1
loading slot for articulated truck, and 1 loading slot for a standard
truck
4. Provide truck maneuvering area outside the RROW (with in property
lines only).

The Stated Project requirements are as follows:

1. Administration (Two floors)


2. Reception Room
3. Executive area
4. Department Office
5. Conference Room
6. Toilets
7. Employees Facilities ( Ground Floor)
8. Cafeteria
9. Quite Lounges
10. Recreation Area
11. Factory Men’s & Women’s Lockers & Toilet
12. Office Men’s & Women’s Lockers & Toilet
13. Meeting Rooms
14. First Aid Clinic
15. Operations & Maintenance
16. Manufacturing Area

https://tip.instructure.com/courses/29639/quizzes/428764 97/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

17. Warehousing Area/ Truck Loading Area


18. Utilities
19. Generator Room
20. Domestic Water Cistern
21. Overhead Water
22. Pump Room
23. Solid Waste Stora

 
27 sq. m

Correct!  
21 sq. m

 
425 sq. m

 
420 sq. m

Question 92 1
/ 1 pts

Q:

How wide is the road right of way on the northern side?

---------

PROJECT #2: GARMENTS FACTORY

A multi-national company, Far East Garments Manufacturing Inc. (The


Client), has decided to expand its operation in Asia and put up
a GARMENTS FACTORY (The Project) in an Industrial Area at the Subic
Freeport, Olongapo City, Zambales. The factory shall be erected in
a through-lot a Total Lot Area (TLA) of 5,000.00 sq. m. The lot’s 50
meters wide frontage faces north and bounded by a 21.00 meters wide
street. The rear lot faces South on an 18.00 meters wide road right of
way. The rectangular lot which has a depth of 100.00 meters has a
moderate slope of 4 % towards the narrower street.

The Garments Factory is envisioned to be one of the most modern


manufacturing plants in Asia having its aim of providing service to the big

https://tip.instructure.com/courses/29639/quizzes/428764 98/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

name brands in clothing industry. The major stock holder of the company
is a known environmentalist thus they have hired an Architect who is also
a known practitioner of Green Architecture.

The site bounded on the North by a wide street with 2.40 meters side
walk on each side while the narrower RROW is bounded by a 1.80
meter side walk on each side. To the east of the site is
another garments factory and to its west is a plastic factory.
Across the wider street is a newly-built shoe factory. The rear side of
the lot faces a tire factory.

The following development controls apply to the project site:

1. Zoning Classification is a I-2 (Industrial Two)- a medium industrial


use or occupancy,
2. Base on the NCBP 2005 Revised Implementing Rules and
Regulations (R-IRR)

The project site has the following development limitations:

1. The prescribed minimum setbacks at ground floor are 00 meters at


front and 3.0 meter at sides and rear.
2. A building Height Limit (BHL) of 21.00 meters but not exceed the
duly-approved BHL in the major zone it is part of
3. A minimum required parking of 1 bus slot for every 100 workers, 1
loading slot for articulated truck, and 1 loading slot for a standard
truck
4. Provide truck maneuvering area outside the RROW (with in property
lines only).

The Stated Project requirements are as follows:

1. Administration (Two floors)


2. Reception Room
3. Executive area
4. Department Office
5. Conference Room
6. Toilets
7. Employees Facilities ( Ground Floor)
8. Cafeteria
9. Quite Lounges
https://tip.instructure.com/courses/29639/quizzes/428764 99/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

10. Recreation Area


11. Factory Men’s & Women’s Lockers & Toilet
12. Office Men’s & Women’s Lockers & Toilet
13. Meeting Rooms
14. First Aid Clinic
15. Operations & Maintenance
16. Manufacturing Area
17. Warehousing Area/ Truck Loading Area
18. Utilities
19. Generator Room
20. Domestic Water Cistern
21. Overhead Water
22. Pump Room
23. Solid Waste Stora

 
10.20 m

 
12.00 m

 
7.20 m

Correct!  
21.00 m

Question 93 1
/ 1 pts

Q:

Based on the Rule VIII of the NBCP, what are the minimum setbacks of
this project on the front, sides and rear if the site is fronting a 25 meters
wide RROW?

---------

PROJECT #2: GARMENTS FACTORY

A multi-national company, Far East Garments Manufacturing Inc. (The


Client), has decided to expand its operation in Asia and put up
a GARMENTS FACTORY (The Project) in an Industrial Area at the Subic
https://tip.instructure.com/courses/29639/quizzes/428764 100/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

Freeport, Olongapo City, Zambales. The factory shall be erected in


a through-lot a Total Lot Area (TLA) of 5,000.00 sq. m. The lot’s 50
meters wide frontage faces north and bounded by a 21.00 meters wide
street. The rear lot faces South on an 18.00 meters wide road right of
way. The rectangular lot which has a depth of 100.00 meters has a
moderate slope of 4 % towards the narrower street.

The Garments Factory is envisioned to be one of the most modern


manufacturing plants in Asia having its aim of providing service to the big
name brands in clothing industry. The major stock holder of the company
is a known environmentalist thus they have hired an Architect who is also
a known practitioner of Green Architecture.

The site bounded on the North by a wide street with 2.40 meters side
walk on each side while the narrower RROW is bounded by a 1.80
meter side walk on each side. To the east of the site is
another garments factory and to its west is a plastic factory.
Across the wider street is a newly-built shoe factory. The rear side of
the lot faces a tire factory.

The following development controls apply to the project site:

1. Zoning Classification is a I-2 (Industrial Two)- a medium industrial


use or occupancy,
2. Base on the NCBP 2005 Revised Implementing Rules and
Regulations (R-IRR)

The project site has the following development limitations:

1. The prescribed minimum setbacks at ground floor are 00 meters at


front and 3.0 meter at sides and rear.
2. A building Height Limit (BHL) of 21.00 meters but not exceed the
duly-approved BHL in the major zone it is part of
3. A minimum required parking of 1 bus slot for every 100 workers, 1
loading slot for articulated truck, and 1 loading slot for a standard
truck
4. Provide truck maneuvering area outside the RROW (with in property
lines only).

The Stated Project requirements are as follows:

https://tip.instructure.com/courses/29639/quizzes/428764 101/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

1. Administration (Two floors)


2. Reception Room
3. Executive area
4. Department Office
5. Conference Room
6. Toilets
7. Employees Facilities ( Ground Floor)
8. Cafeteria
9. Quite Lounges
10. Recreation Area
11. Factory Men’s & Women’s Lockers & Toilet
12. Office Men’s & Women’s Lockers & Toilet
13. Meeting Rooms
14. First Aid Clinic
15. Operations & Maintenance
16. Manufacturing Area
17. Warehousing Area/ Truck Loading Area
18. Utilities
19. Generator Room
20. Domestic Water Cistern
21. Overhead Water
22. Pump Room
23. Solid Waste Stora

 
7.0 m , 3.0 m , 3.0 m

Correct!  
6.0 m , 3.0 m , 3.0 m

 
) 5.0 m , 3.0 m , 3.0 m

 
8.0 m , 5.0 m , 5.0 m

Question 94 1
/ 1 pts

Q:

https://tip.instructure.com/courses/29639/quizzes/428764 102/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

60. How about the articulated truck long hooded prime mover bulk carrier,
what is the minimum dimension of parking/loading slot?

---------

PROJECT #2: GARMENTS FACTORY

A multi-national company, Far East Garments Manufacturing Inc. (The


Client), has decided to expand its operation in Asia and put up
a GARMENTS FACTORY (The Project) in an Industrial Area at the Subic
Freeport, Olongapo City, Zambales. The factory shall be erected in
a through-lot a Total Lot Area (TLA) of 5,000.00 sq. m. The lot’s 50
meters wide frontage faces north and bounded by a 21.00 meters wide
street. The rear lot faces South on an 18.00 meters wide road right of
way. The rectangular lot which has a depth of 100.00 meters has a
moderate slope of 4 % towards the narrower street.

The Garments Factory is envisioned to be one of the most modern


manufacturing plants in Asia having its aim of providing service to the big
name brands in clothing industry. The major stock holder of the company
is a known environmentalist thus they have hired an Architect who is also
a known practitioner of Green Architecture.

The site bounded on the North by a wide street with 2.40 meters side
walk on each side while the narrower RROW is bounded by a 1.80
meter side walk on each side. To the east of the site is
another garments factory and to its west is a plastic factory.
Across the wider street is a newly-built shoe factory. The rear side of
the lot faces a tire factory.

The following development controls apply to the project site:

1. Zoning Classification is a I-2 (Industrial Two)- a medium industrial


use or occupancy,
2. Base on the NCBP 2005 Revised Implementing Rules and
Regulations (R-IRR)

The project site has the following development limitations:

1. The prescribed minimum setbacks at ground floor are 00 meters at


front and 3.0 meter at sides and rear.
2. A building Height Limit (BHL) of 21.00 meters but not exceed the
duly-approved BHL in the major zone it is part of

https://tip.instructure.com/courses/29639/quizzes/428764 103/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

3. A minimum required parking of 1 bus slot for every 100 workers, 1
loading slot for articulated truck, and 1 loading slot for a standard
truck
4. Provide truck maneuvering area outside the RROW (with in property
lines only).

The Stated Project requirements are as follows:

1. Administration (Two floors)


2. Reception Room
3. Executive area
4. Department Office
5. Conference Room
6. Toilets
7. Employees Facilities ( Ground Floor)
8. Cafeteria
9. Quite Lounges
10. Recreation Area
11. Factory Men’s & Women’s Lockers & Toilet
12. Office Men’s & Women’s Lockers & Toilet
13. Meeting Rooms
14. First Aid Clinic
15. Operations & Maintenance
16. Manufacturing Area
17. Warehousing Area/ Truck Loading Area
18. Utilities
19. Generator Room
20. Domestic Water Cistern
21. Overhead Water
22. Pump Room
23. Solid Waste Stora

Correct!  
) 3.60 x 18.00m

 
2.15 x 6.00 m

 
3.60 x 12.00 m

 
2.40 x 5.00 m

https://tip.instructure.com/courses/29639/quizzes/428764 104/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

Question 95 0
/ 1 pts

Q:

Based on the correct answer of no.153, how much floor space should you
allot for the dining hall of the canteen of this project if the 250 workers
shall be divided into 2 shifts?

---------

PROJECT #2: GARMENTS FACTORY

A multi-national company, Far East Garments Manufacturing Inc. (The


Client), has decided to expand its operation in Asia and put up
a GARMENTS FACTORY (The Project) in an Industrial Area at the Subic
Freeport, Olongapo City, Zambales. The factory shall be erected in
a through-lot a Total Lot Area (TLA) of 5,000.00 sq. m. The lot’s 50
meters wide frontage faces north and bounded by a 21.00 meters wide
street. The rear lot faces South on an 18.00 meters wide road right of
way. The rectangular lot which has a depth of 100.00 meters has a
moderate slope of 4 % towards the narrower street.

The Garments Factory is envisioned to be one of the most modern


manufacturing plants in Asia having its aim of providing service to the big
name brands in clothing industry. The major stock holder of the company
is a known environmentalist thus they have hired an Architect who is also
a known practitioner of Green Architecture.

The site bounded on the North by a wide street with 2.40 meters side
walk on each side while the narrower RROW is bounded by a 1.80
meter side walk on each side. To the east of the site is
another garments factory and to its west is a plastic factory.
Across the wider street is a newly-built shoe factory. The rear side of
the lot faces a tire factory.

The following development controls apply to the project site:

1. Zoning Classification is a I-2 (Industrial Two)- a medium industrial


use or occupancy,

https://tip.instructure.com/courses/29639/quizzes/428764 105/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

2. Base on the NCBP 2005 Revised Implementing Rules and


Regulations (R-IRR)

The project site has the following development limitations:

1. The prescribed minimum setbacks at ground floor are 00 meters at


front and 3.0 meter at sides and rear.
2. A building Height Limit (BHL) of 21.00 meters but not exceed the
duly-approved BHL in the major zone it is part of
3. A minimum required parking of 1 bus slot for every 100 workers, 1
loading slot for articulated truck, and 1 loading slot for a standard
truck
4. Provide truck maneuvering area outside the RROW (with in property
lines only).

The Stated Project requirements are as follows:

1. Administration (Two floors)


2. Reception Room
3. Executive area
4. Department Office
5. Conference Room
6. Toilets
7. Employees Facilities ( Ground Floor)
8. Cafeteria
9. Quite Lounges
10. Recreation Area
11. Factory Men’s & Women’s Lockers & Toilet
12. Office Men’s & Women’s Lockers & Toilet
13. Meeting Rooms
14. First Aid Clinic
15. Operations & Maintenance
16. Manufacturing Area
17. Warehousing Area/ Truck Loading Area
18. Utilities
19. Generator Room
20. Domestic Water Cistern
21. Overhead Water
22. Pump Room

https://tip.instructure.com/courses/29639/quizzes/428764 106/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

23. Solid Waste Stora

 
450 sq. m

 
225 sq. m

orrect answer  
175 sq. m

ou Answered  
350 sq. m

Question 96 1
/ 1 pts

Q:

According to the NBCP in Rule 12, what is the occupant load factor of a
warehouse?

---------

PROJECT #2: GARMENTS FACTORY

A multi-national company, Far East Garments Manufacturing Inc. (The


Client), has decided to expand its operation in Asia and put up
a GARMENTS FACTORY (The Project) in an Industrial Area at the Subic
Freeport, Olongapo City, Zambales. The factory shall be erected in
a through-lot a Total Lot Area (TLA) of 5,000.00 sq. m. The lot’s 50
meters wide frontage faces north and bounded by a 21.00 meters wide
street. The rear lot faces South on an 18.00 meters wide road right of
way. The rectangular lot which has a depth of 100.00 meters has a
moderate slope of 4 % towards the narrower street.

The Garments Factory is envisioned to be one of the most modern


manufacturing plants in Asia having its aim of providing service to the big
name brands in clothing industry. The major stock holder of the company

https://tip.instructure.com/courses/29639/quizzes/428764 107/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

is a known environmentalist thus they have hired an Architect who is also


a known practitioner of Green Architecture.

The site bounded on the North by a wide street with 2.40 meters side
walk on each side while the narrower RROW is bounded by a 1.80
meter side walk on each side. To the east of the site is
another garments factory and to its west is a plastic factory.
Across the wider street is a newly-built shoe factory. The rear side of
the lot faces a tire factory.

The following development controls apply to the project site:

1. Zoning Classification is a I-2 (Industrial Two)- a medium industrial


use or occupancy,
2. Base on the NCBP 2005 Revised Implementing Rules and
Regulations (R-IRR)

The project site has the following development limitations:

1. The prescribed minimum setbacks at ground floor are 00 meters at


front and 3.0 meter at sides and rear.
2. A building Height Limit (BHL) of 21.00 meters but not exceed the
duly-approved BHL in the major zone it is part of
3. A minimum required parking of 1 bus slot for every 100 workers, 1
loading slot for articulated truck, and 1 loading slot for a standard
truck
4. Provide truck maneuvering area outside the RROW (with in property
lines only).

The Stated Project requirements are as follows:

1. Administration (Two floors)


2. Reception Room
3. Executive area
4. Department Office
5. Conference Room
6. Toilets
7. Employees Facilities ( Ground Floor)
8. Cafeteria
9. Quite Lounges
10. Recreation Area
https://tip.instructure.com/courses/29639/quizzes/428764 108/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

11. Factory Men’s & Women’s Lockers & Toilet


12. Office Men’s & Women’s Lockers & Toilet
13. Meeting Rooms
14. First Aid Clinic
15. Operations & Maintenance
16. Manufacturing Area
17. Warehousing Area/ Truck Loading Area
18. Utilities
19. Generator Room
20. Domestic Water Cistern
21. Overhead Water
22. Pump Room
23. Solid Waste Stora

 
1.80 sq. m

 
1.40 sq. m

 
9.30 sq. m

Correct!  
28.00 sq. m

Question 97 0
/ 1 pts

Q: Where will you place the ware housing and truck loading area?

-----------

PROJECT #2: GARMENTS FACTORY

A multi-national company, Far East Garments Manufacturing Inc. (The


Client), has decided to expand its operation in Asia and put up
a GARMENTS FACTORY (The Project) in an Industrial Area at the Subic
Freeport, Olongapo City, Zambales. The factory shall be erected in
a through-lot a Total Lot Area (TLA) of 5,000.00 sq. m. The lot’s 50
meters wide frontage faces north and bounded by a 21.00 meters wide
street. The rear lot faces South on an 18.00 meters wide road right of

https://tip.instructure.com/courses/29639/quizzes/428764 109/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

way. The rectangular lot which has a depth of 100.00 meters has a


moderate slope of 4 % towards the narrower street.

The Garments Factory is envisioned to be one of the most modern


manufacturing plants in Asia having its aim of providing service to the big
name brands in clothing industry. The major stock holder of the company
is a known environmentalist thus they have hired an Architect who is also
a known practitioner of Green Architecture.

The site bounded on the North by a wide street with 2.40 meters side
walk on each side while the narrower RROW is bounded by a 1.80
meter side walk on each side. To the east of the site is
another garments factory and to its west is a plastic factory.
Across the wider street is a newly-built shoe factory. The rear side of
the lot faces a tire factory.

The following development controls apply to the project site:

1. Zoning Classification is a I-2 (Industrial Two)- a medium industrial


use or occupancy,
2. Base on the NCBP 2005 Revised Implementing Rules and
Regulations (R-IRR)

The project site has the following development limitations:

1. The prescribed minimum setbacks at ground floor are 00 meters at


front and 3.0 meter at sides and rear.
2. A building Height Limit (BHL) of 21.00 meters but not exceed the
duly-approved BHL in the major zone it is part of
3. A minimum required parking of 1 bus slot for every 100 workers, 1
loading slot for articulated truck, and 1 loading slot for a standard
truck
4. Provide truck maneuvering area outside the RROW (with in property
lines only).

The Stated Project requirements are as follows:

1. Administration (Two floors)


2. Reception Room
3. Executive area
4. Department Office

https://tip.instructure.com/courses/29639/quizzes/428764 110/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

5. Conference Room
6. Toilets
7. Employees Facilities ( Ground Floor)
8. Cafeteria
9. Quite Lounges
10. Recreation Area
11. Factory Men’s & Women’s Lockers & Toilet
12. Office Men’s & Women’s Lockers & Toilet
13. Meeting Rooms
14. First Aid Clinic
15. Operations & Maintenance
16. Manufacturing Area
17. Warehousing Area/ Truck Loading Area
18. Utilities
19. Generator Room
20. Domestic Water Cistern
21. Overhead Water
22. Pump Room
23. Solid Waste Storage

 
East

 
West

orrect answer  
South

ou Answered  
North

Question 98 0
/ 1 pts

Q:

What is the Maximum Allowable Paved Open Spaces (USA) of this


project?

---------

https://tip.instructure.com/courses/29639/quizzes/428764 111/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

PROJECT #2: GARMENTS FACTORY

A multi-national company, Far East Garments Manufacturing Inc. (The


Client), has decided to expand its operation in Asia and put up
a GARMENTS FACTORY (The Project) in an Industrial Area at the Subic
Freeport, Olongapo City, Zambales. The factory shall be erected in
a through-lot a Total Lot Area (TLA) of 5,000.00 sq. m. The lot’s 50
meters wide frontage faces north and bounded by a 21.00 meters wide
street. The rear lot faces South on an 18.00 meters wide road right of
way. The rectangular lot which has a depth of 100.00 meters has a
moderate slope of 4 % towards the narrower street.

The Garments Factory is envisioned to be one of the most modern


manufacturing plants in Asia having its aim of providing service to the big
name brands in clothing industry. The major stock holder of the company
is a known environmentalist thus they have hired an Architect who is also
a known practitioner of Green Architecture.

The site bounded on the North by a wide street with 2.40 meters side
walk on each side while the narrower RROW is bounded by a 1.80
meter side walk on each side. To the east of the site is
another garments factory and to its west is a plastic factory.
Across the wider street is a newly-built shoe factory. The rear side of
the lot faces a tire factory.

The following development controls apply to the project site:

1. Zoning Classification is a I-2 (Industrial Two)- a medium industrial


use or occupancy,
2. Base on the NCBP 2005 Revised Implementing Rules and
Regulations (R-IRR)

The project site has the following development limitations:

1. The prescribed minimum setbacks at ground floor are 00 meters at


front and 3.0 meter at sides and rear.
2. A building Height Limit (BHL) of 21.00 meters but not exceed the
duly-approved BHL in the major zone it is part of
3. A minimum required parking of 1 bus slot for every 100 workers, 1
loading slot for articulated truck, and 1 loading slot for a standard
truck

https://tip.instructure.com/courses/29639/quizzes/428764 112/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

4. Provide truck maneuvering area outside the RROW (with in property


lines only).

The Stated Project requirements are as follows:

1. Administration (Two floors)


2. Reception Room
3. Executive area
4. Department Office
5. Conference Room
6. Toilets
7. Employees Facilities ( Ground Floor)
8. Cafeteria
9. Quite Lounges
10. Recreation Area
11. Factory Men’s & Women’s Lockers & Toilet
12. Office Men’s & Women’s Lockers & Toilet
13. Meeting Rooms
14. First Aid Clinic
15. Operations & Maintenance
16. Manufacturing Area
17. Warehousing Area/ Truck Loading Area
18. Utilities
19. Generator Room
20. Domestic Water Cistern
21. Overhead Water
22. Pump Room
23. Solid Waste Stora

 
5%

ou Answered  
15%

orrect answer  
10%

 
20%

https://tip.instructure.com/courses/29639/quizzes/428764 113/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

Question 99 0
/ 1 pts

Q: What pavement type generates the highest amount of reflected light


and heat?

-----------------

PROJECT# 3: Residential Cluster Development

An owner has decided that his R-1 property, with TLA of 3,840 sq. m; and
located in an urban area, shall serve as an Open Market residential
Cluster Development. Individual lots shall have 20m depth. The project
shall include 10 exclusive, medium cost structures each having total lot
area of 320 sq. m.

The project site is through lot, rectangular in shape, having 48m wide
frontage that is facing east. The project site uniformly slopes at 1 %
draining east. The 15m RROW has 1.80m wide sidewalk on each side.

An 8 m wide cluster street bisects the site lengthwise and intersects the
main RROW at right angle. The road is at 1 % uniform slope from west to
east, which also the direction of the cluster street that serves as direct
access to 10 lots, 5 on each side of the street cluster.

 
Coarse gravel

orrect answer  
Poured or cast-on-site concrete

ou Answered  
Red brick

 
Asphalt

Question 100 0
/ 1 pts

https://tip.instructure.com/courses/29639/quizzes/428764 114/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

Q: Based on fig. VIII.1, what shall be the AMBF for each 320 sq. m. lot?

-----------------

PROJECT# 3: Residential Cluster Development

An owner has decided that his R-1 property, with TLA of 3,840 sq. m; and
located in an urban area, shall serve as an Open Market residential
Cluster Development. Individual lots shall have 20m depth. The project
shall include 10 exclusive, medium cost structures each having total lot
area of 320 sq. m.

The project site is through lot, rectangular in shape, having 48m wide
frontage that is facing east. The project site uniformly slopes at 1 %
draining east. The 15m RROW has 1.80m wide sidewalk on each side.

An 8 m wide cluster street bisects the site lengthwise and intersects the
main RROW at right angle. The road is at 1 % uniform slope from west to
east, which also the direction of the cluster street that serves as direct
access to 10 lots, 5 on each side of the street cluster.

 
150 sq. m

orrect answer  
162 sq. m

 
152 sq. m

ou Answered  
142sq. m

Question 101 1
/ 1 pts

Q: Where is the ideal placement of the bed head board?

------------

https://tip.instructure.com/courses/29639/quizzes/428764 115/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

PROJECT# 3: Residential Cluster Development

An owner has decided that his R-1 property, with TLA of 3,840 sq. m; and
located in an urban area, shall serve as an Open Market residential
Cluster Development. Individual lots shall have 20m depth. The project
shall include 10 exclusive, medium cost structures each having total lot
area of 320 sq. m.

The project site is through lot, rectangular in shape, having 48m wide
frontage that is facing east. The project site uniformly slopes at 1 %
draining east. The 15m RROW has 1.80m wide sidewalk on each side.

An 8 m wide cluster street bisects the site lengthwise and intersects the
main RROW at right angle. The road is at 1 % uniform slope from west to
east, which also the direction of the cluster street that serves as direct
access to 10 lots, 5 on each side of the street cluster.

 
At a wall with fixed window

Correct!  
At a plain wall opposite to the window

 
At a wall with operable window

 
At a plain wall with a toilet on the other side

Question 102 0
/ 1 pts

Q:Which of the following parts of the house is most unsafe during


earthquake?

-------

PROJECT# 3: Residential Cluster Development

An owner has decided that his R-1 property, with TLA of 3,840 sq. m; and
located in an urban area, shall serve as an Open Market residential
Cluster Development. Individual lots shall have 20m depth. The project
https://tip.instructure.com/courses/29639/quizzes/428764 116/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

shall include 10 exclusive, medium cost structures each having total lot
area of 320 sq. m.

The project site is through lot, rectangular in shape, having 48m wide
frontage that is facing east. The project site uniformly slopes at 1 %
draining east. The 15m RROW has 1.80m wide sidewalk on each side.

An 8 m wide cluster street bisects the site lengthwise and intersects the
main RROW at right angle. The road is at 1 % uniform slope from west to
east, which also the direction of the cluster street that serves as direct
access to 10 lots, 5 on each side of the street cluster.

 
Ground Floor

 
Stairway

ou Answered  
Mezzanine

orrect answer  
Attic

Question 103 0
/ 1 pts

Q: Based on calculated AMBF using prescribed setbacks, what shall be


the maximum total gross floor area for each 320sq. m lot?

--------------

PROJECT# 3: Residential Cluster Development

An owner has decided that his R-1 property, with TLA of 3,840 sq. m; and
located in an urban area, shall serve as an Open Market residential
Cluster Development. Individual lots shall have 20m depth. The project
shall include 10 exclusive, medium cost structures each having total lot
area of 320 sq. m.

https://tip.instructure.com/courses/29639/quizzes/428764 117/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

The project site is through lot, rectangular in shape, having 48m wide
frontage that is facing east. The project site uniformly slopes at 1 %
draining east. The 15m RROW has 1.80m wide sidewalk on each side.

An 8 m wide cluster street bisects the site lengthwise and intersects the
main RROW at right angle. The road is at 1 % uniform slope from west to
east, which also the direction of the cluster street that serves as direct
access to 10 lots, 5 on each side of the street cluster.

 
512 sq. m

orrect answer  
486sq. m

ou Answered  
480 sq. m

 
720 sq. m

Question 104 0
/ 1 pts

Q: Based on fig. VIII.1, what shall be the MACA for each 320 sq. m. lot?

1.

------------

PROJECT# 3: Residential Cluster Development

An owner has decided that his R-1 property, with TLA of 3,840 sq. m; and
located in an urban area, shall serve as an Open Market residential
Cluster Development. Individual lots shall have 20m depth. The project
shall include 10 exclusive, medium cost structures each having total lot
area of 320 sq. m.

The project site is through lot, rectangular in shape, having 48m wide
frontage that is facing east. The project site uniformly slopes at 1 %
draining east. The 15m RROW has 1.80m wide sidewalk on each side.

https://tip.instructure.com/courses/29639/quizzes/428764 118/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

An 8 m wide cluster street bisects the site lengthwise and intersects the
main RROW at right angle. The road is at 1 % uniform slope from west to
east, which also the direction of the cluster street that serves as direct
access to 10 lots, 5 on each side of the street cluster.

ou Answered  
72 sq. m

 
234 sq. m

 
80 sq. m

orrect answer  
248 sq. m

Question 105 0
/ 1 pts

Q:Based on fig. VIII.1, what shall be the USA for each 320 sq. m. lot?

------------

PROJECT# 3: Residential Cluster Development

An owner has decided that his R-1 property, with TLA of 3,840 sq. m; and
located in an urban area, shall serve as an Open Market residential
Cluster Development. Individual lots shall have 20m depth. The project
shall include 10 exclusive, medium cost structures each having total lot
area of 320 sq. m.

The project site is through lot, rectangular in shape, having 48m wide
frontage that is facing east. The project site uniformly slopes at 1 %
draining east. The 15m RROW has 1.80m wide sidewalk on each side.

An 8 m wide cluster street bisects the site lengthwise and intersects the
main RROW at right angle. The road is at 1 % uniform slope from west to
east, which also the direction of the cluster street that serves as direct
access to 10 lots, 5 on each side of the street cluster.

https://tip.instructure.com/courses/29639/quizzes/428764 119/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

 
158 sq. m

ou Answered  
86 sq. m

orrect answer  
72 sq.

 
80 sq. m

Question 106 1
/ 1 pts

Q: Which of the following should be considered if the site of the house is a


coastal area?

-----------------

PROJECT# 3: Residential Cluster Development

An owner has decided that his R-1 property, with TLA of 3,840 sq. m; and
located in an urban area, shall serve as an Open Market residential
Cluster Development. Individual lots shall have 20m depth. The project
shall include 10 exclusive, medium cost structures each having total lot
area of 320 sq. m.

The project site is through lot, rectangular in shape, having 48m wide
frontage that is facing east. The project site uniformly slopes at 1 %
draining east. The 15m RROW has 1.80m wide sidewalk on each side.

An 8 m wide cluster street bisects the site lengthwise and intersects the
main RROW at right angle. The road is at 1 % uniform slope from west to
east, which also the direction of the cluster street that serves as direct
access to 10 lots, 5 on each side of the street cluster.

Correct!  
Concrete roof deck

 
Galvanized iron roo

https://tip.instructure.com/courses/29639/quizzes/428764 120/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

 
Tubular steel trellises

 
Cast iron window grilles

Question 107 0
/ 1 pts

Q: What is the Net floor area best applies to standard bedside table, with
drawers closed?

-----------------

PROJECT# 3: Residential Cluster Development

An owner has decided that his R-1 property, with TLA of 3,840 sq. m; and
located in an urban area, shall serve as an Open Market residential
Cluster Development. Individual lots shall have 20m depth. The project
shall include 10 exclusive, medium cost structures each having total lot
area of 320 sq. m.

The project site is through lot, rectangular in shape, having 48m wide
frontage that is facing east. The project site uniformly slopes at 1 %
draining east. The 15m RROW has 1.80m wide sidewalk on each side.

An 8 m wide cluster street bisects the site lengthwise and intersects the
main RROW at right angle. The road is at 1 % uniform slope from west to
east, which also the direction of the cluster street that serves as direct
access to 10 lots, 5 on each side of the street cluster.

orrect answer  
0.21 sq. m

 
0.51 sq. m

 
0.31 sq. m

ou Answered  
) 0.41 sq. m

https://tip.instructure.com/courses/29639/quizzes/428764 121/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

Question 108 1
/ 1 pts

Q:Based on Table VII.G.1 of PD 1096, what shall be the maximum gross


floor area for each 320 sq. m lot?

---------------

PROJECT# 3: Residential Cluster Development

An owner has decided that his R-1 property, with TLA of 3,840 sq. m; and
located in an urban area, shall serve as an Open Market residential
Cluster Development. Individual lots shall have 20m depth. The project
shall include 10 exclusive, medium cost structures each having total lot
area of 320 sq. m.

The project site is through lot, rectangular in shape, having 48m wide
frontage that is facing east. The project site uniformly slopes at 1 %
draining east. The 15m RROW has 1.80m wide sidewalk on each side.

An 8 m wide cluster street bisects the site lengthwise and intersects the
main RROW at right angle. The road is at 1 % uniform slope from west to
east, which also the direction of the cluster street that serves as direct
access to 10 lots, 5 on each side of the street cluster.

Correct!  
480 sq. m

 
512 sq. m

 
) 416 sq. m

 
576 sq. m

Question 109 0
/ 1 pts

https://tip.instructure.com/courses/29639/quizzes/428764 122/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

Q: In terms of architectural exterior finishing & building insulation, which of


the following is not a good color for deck roof, if introduced for  prototype
house?  

-----------------

PROJECT# 3: Residential Cluster Development

An owner has decided that his R-1 property, with TLA of 3,840 sq. m; and
located in an urban area, shall serve as an Open Market residential
Cluster Development. Individual lots shall have 20m depth. The project
shall include 10 exclusive, medium cost structures each having total lot
area of 320 sq. m.

The project site is through lot, rectangular in shape, having 48m wide
frontage that is facing east. The project site uniformly slopes at 1 %
draining east. The 15m RROW has 1.80m wide sidewalk on each side.

An 8 m wide cluster street bisects the site lengthwise and intersects the
main RROW at right angle. The road is at 1 % uniform slope from west to
east, which also the direction of the cluster street that serves as direct
access to 10 lots, 5 on each side of the street cluster.

 
Medium gray

 
Medium beige

orrect answer  
Light gray

ou Answered  
Dark black

Question 110 0
/ 1 pts

https://tip.instructure.com/courses/29639/quizzes/428764 123/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

Q:What is the best façade to be used in the house if there is a limited


budget?

------------

PROJECT# 3: Residential Cluster Development

An owner has decided that his R-1 property, with TLA of 3,840 sq. m; and
located in an urban area, shall serve as an Open Market residential
Cluster Development. Individual lots shall have 20m depth. The project
shall include 10 exclusive, medium cost structures each having total lot
area of 320 sq. m.

The project site is through lot, rectangular in shape, having 48m wide
frontage that is facing east. The project site uniformly slopes at 1 %
draining east. The 15m RROW has 1.80m wide sidewalk on each side.

An 8 m wide cluster street bisects the site lengthwise and intersects the
main RROW at right angle. The road is at 1 % uniform slope from west to
east, which also the direction of the cluster street that serves as direct
access to 10 lots, 5 on each side of the street cluster.

ou Answered  
Tropical Asian

 
American

orrect answer  
Modern Asian

 
Mediterranean

Question 111 0
/ 1 pts

Q: Based on fig. VIII.1, what shall be the ISA for each 320 sq. m. lot?

------------

PROJECT# 3: Residential Cluster Development


https://tip.instructure.com/courses/29639/quizzes/428764 124/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

An owner has decided that his R-1 property, with TLA of 3,840 sq. m; and
located in an urban area, shall serve as an Open Market residential
Cluster Development. Individual lots shall have 20m depth. The project
shall include 10 exclusive, medium cost structures each having total lot
area of 320 sq. m.

The project site is through lot, rectangular in shape, having 48m wide
frontage that is facing east. The project site uniformly slopes at 1 %
draining east. The 15m RROW has 1.80m wide sidewalk on each side.

An 8 m wide cluster street bisects the site lengthwise and intersects the
main RROW at right angle. The road is at 1 % uniform slope from west to
east, which also the direction of the cluster street that serves as direct
access to 10 lots, 5 on each side of the street cluster.

 
72 sq. m

orrect answer  
86 sq. m

ou Answered  
80 sq. m

 
158 sq. m

Question 112 1
/ 1 pts

Q:A king-sized bed should fit inside the master bedroom of each house.
What is the rea of king sized bed?    

-----------------

PROJECT# 3: Residential Cluster Development

An owner has decided that his R-1 property, with TLA of 3,840 sq. m; and
located in an urban area, shall serve as an Open Market residential
Cluster Development. Individual lots shall have 20m depth. The project

https://tip.instructure.com/courses/29639/quizzes/428764 125/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

shall include 10 exclusive, medium cost structures each having total lot
area of 320 sq. m.

The project site is through lot, rectangular in shape, having 48m wide
frontage that is facing east. The project site uniformly slopes at 1 %
draining east. The 15m RROW has 1.80m wide sidewalk on each side.

An 8 m wide cluster street bisects the site lengthwise and intersects the
main RROW at right angle. The road is at 1 % uniform slope from west to
east, which also the direction of the cluster street that serves as direct
access to 10 lots, 5 on each side of the street cluster.

Correct!  
3.8 sq. m

 
3.4 sq. m

 
3.6 sq. m

 
5 sq. m

Question 113 0
/ 1 pts

Q:Which of the following is the best bedroom floor finish for a person with
asthma?

---------------

PROJECT# 3: Residential Cluster Development

An owner has decided that his R-1 property, with TLA of 3,840 sq. m; and
located in an urban area, shall serve as an Open Market residential
Cluster Development. Individual lots shall have 20m depth. The project
shall include 10 exclusive, medium cost structures each having total lot
area of 320 sq. m.

The project site is through lot, rectangular in shape, having 48m wide
frontage that is facing east. The project site uniformly slopes at 1 %
https://tip.instructure.com/courses/29639/quizzes/428764 126/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

draining east. The 15m RROW has 1.80m wide sidewalk on each side.

An 8 m wide cluster street bisects the site lengthwise and intersects the
main RROW at right angle. The road is at 1 % uniform slope from west to
east, which also the direction of the cluster street that serves as direct
access to 10 lots, 5 on each side of the street cluster.

 
Carpet

ou Answered  
Linoleum

 
Vinyl

orrect answer  
Hardwood

Question 114 1
/ 1 pts

Who designed Central Park in New York?

 
Kohn Peterson Fox

 
Robert Wagner

Correct!  
Fredrick Law Olmstead

 
Frank Lloyd Wright

Question 115 0
/ 1 pts

One the following is the approving government unit for subdivision project
development permit. Which would that be?

https://tip.instructure.com/courses/29639/quizzes/428764 127/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

ou Answered  
HLURB

 
NHA

orrect answer  
LGU

 
HIGC

Question 116 0
/ 1 pts

From the major components in a comprehensive or master plan, under


w/c component are hospitals & clinics included?

 
land use plan public utilities

ou Answered  
related service facilities plan

 
circulation transportation plan

orrect answer  
community facilities plan

Question 117 1
/ 1 pts

When designing a low-cost housing project, which of the following laws


would be appropriate as a basis for design?

 
International Law on Human Settlement

Correct!  
BP 220

 
RA 7279 or UDHA

https://tip.instructure.com/courses/29639/quizzes/428764 128/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

 
PD 957

Question 118 1
/ 1 pts

A piece of grassy land, especially one used for growing hay as a pasture
for grazing animals; low grassy land near a river or stream.

Correct!  
Meadow

 
None of the choices

 
contour

 
Farmland Terrain

Question 119 1
/ 1 pts

A profession which falls between planning and architecture. It deals with


the large scale organization and design of the city, with the massing and
organization and the space between them, but not with the design of the
individual buildings.

 
Urban Theorist

 
City administration

 
City Planning

Correct!  
Urban Design

https://tip.instructure.com/courses/29639/quizzes/428764 129/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

Question 120 0
/ 1 pts

There are 4 major components in a comprehensive or master plan, under


w/c component are flood control projects included?

 
land use plan

orrect answer  
public utilities related service facilities plan

ou Answered  
community facilities plan

 
circulation transportation plan

Question 121 1
/ 1 pts

A locale with a sizeable agglomeration of people having characteristics of


an urban being.

 
Composite City

 
Chartered City

 
Independent City

Correct!  
City

Question 122 1
/ 1 pts

Which of the following best describe the theory of the relationship of


Downtown Davao and Calinan Poblacion?

https://tip.instructure.com/courses/29639/quizzes/428764 130/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

 
none of the above

Correct!  
Multiple-nuclei theory

 
Central place theory

 
Concentric zone Sector

Question 123 1
/ 1 pts

Which of the following best describes the criss-crossing of overhead


highways, which sometimes presents a clover-leaf form?                 

 
Sidewalk

Correct!  
Flyover

 
Overpass

 
Skyway

Question 124 1
/ 1 pts

What is the land classification or land use of the Puan Area based on the
approved Zoning Ordinance of Davao City?

 
Commercial

 
Residential

 
Industrial

https://tip.instructure.com/courses/29639/quizzes/428764 131/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

Correct!  
Protected-water resource

Question 125 0
/ 1 pts

Which of the following is a best circulation design alternative for a site


plan?

ou Answered  
Parking on the front of the site

 
Wide vehicular roads

 
Provision of a porte-cochere

orrect answer  
Separate pedestrian and vehicular circulation systems.

Question 126 0
/ 1 pts

Which of the following is a long-term plan that is required of the entire


local government unit in the Philippines?

 
Site Plan

 
Social plan

ou Answered  
Urban plan Local

orrect answer  
Comprehensive development plan

https://tip.instructure.com/courses/29639/quizzes/428764 132/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

Question 127 1
/ 1 pts

The orderly arrangement of urban streets and public spaces.

 
Street Planning

 
Spatial Planning

Correct!  
City Planning

 
Open Space Planning

Question 128 1
/ 1 pts

The rough equivalent of the present tenement cities that existed in


Ancient Rome which resulted from the population growth of the city and

Correct!  
Insula

 
Agoras

 
Domus

 
Tenema

Question 129 0
/ 1 pts

Metro Manila is considered a primate city because __________________.

https://tip.instructure.com/courses/29639/quizzes/428764 133/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

orrect answer  
It contains the country’s primary central business district.

ou Answered  
It has a very large population compared to all other urban centers of the
country.

 
It is the largest urban center of the country.

 
It is a metropolitan center.

Question 130 1
/ 1 pts

If the contour interval is 2.0 meters and the contour distance is uniformly
at 5.0 meters, what is the slope of the topography?

 
27 percent

 
67 percent

Correct!  
40 percent

 
53 percent

Question 131 1
/ 1 pts

Written document to transfer the property to one person to another.

Correct!  
Deed

 
Clearance

https://tip.instructure.com/courses/29639/quizzes/428764 134/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

 
Transfer Certificate Title

 
Equity

Question 132 1
/ 1 pts

Which of the following best describe the existing condition of San Pedro
Street?

Correct!  
Urban Decay

 
CBD

 
Institutional area

 
High density residential area

Question 133 1
/ 1 pts

Which of the following best describe the setback from a water line?

 
Right of Way

 
Setback

Correct!  
Easement

 
Crossing

https://tip.instructure.com/courses/29639/quizzes/428764 135/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

Question 134 1
/ 1 pts

The minimum horizontal dimension of a toilet is _____ mm

 
1200mm

 
1100mm

 
1000mm

Correct!  
900mm

Question 135 0
/ 1 pts

The minimum horizontal dimension of a kitchen is _____ meters.

 
20

 
1.35

ou Answered  
2.00

orrect answer  
1.50

Question 136 1
/ 1 pts

https://tip.instructure.com/courses/29639/quizzes/428764 136/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

The minimum horizontal dimension of a habitable room is _____ meters.

                              

 
80

 
2.10

 
1.75

Correct!  
2.00

Question 137 0
/ 1 pts

Mezzanine floors shall have a clear ceiling height not less than ______
meters above and below it.

ou Answered  
1.75

orrect answer  
80

 
2.10

 
2.00

Question 138 0
/ 1 pts

https://tip.instructure.com/courses/29639/quizzes/428764 137/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

Above- stated rooms with natural ventilation shall have ceiling heights of
not less than ______ meters.

ou Answered  
30

orrect answer  
2.70

 
2.10

 
2.40

Question 139 0
/ 1 pts

Habitable rooms provided with artificial ventilation shall have ceiling


heights not less than _____ meters measured from the floor to the ceiling.

 
3.00

ou Answered  
2.70

orrect answer  
2.40

 
2.10

Question 140 1
/ 1 pts

What is the occupant load of a studio-type unit?


https://tip.instructure.com/courses/29639/quizzes/428764 138/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

 
2-3 persons/unit

 
3-4 persons/unit

 
3-5 persons/unit

Correct!  
1-3 persons/ unit

Question 141 0
/ 1 pts

The required building exterior shall be along classical, neo-classical or


stylized lines combined with modern features, what primary architectural
element should be considered?

orrect answer  
Decorative motif of facade

 
External corridor

ou Answered  
Columns

 
Main entrance

Question 142 1
/ 1 pts

What is the most common structural system employed in a medium to


high rise apartment building?

 
All of the above

 
Flat plate, cast-in place r.c. with randomly place columns

https://tip.instructure.com/courses/29639/quizzes/428764 139/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

 
Structural steel framing with baffle slab

Correct!  
R.C. frame with CHB for external envelope and drywall for internal
partitions

Question 143 1
/ 1 pts

What is the best sequence of priority for the space requirement of a studio
type condo unit?

 
Living room, dining room, kitchen, bedroom

Correct!  
Bedroom, dining area, living room, kitchen

 
Kitchen, dining, bedroom, living room

 
Bedroom, kitchen, dining, living room

Question 144 0
/ 1 pts

From the list of finishes, what would be the best for commercial and hotel
kitchens?

orrect answer  
Ceramic tile

 
Marble tile

 
Vinyl tile

ou Answered  
Granite tile

https://tip.instructure.com/courses/29639/quizzes/428764 140/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

Question 145 0
/ 1 pts

From the list of finishes, what would be the best for bedrooms?

ou Answered  
Wood tile

 
Ceramic tile

 
Vinyl

orrect answer  
Carpet tile

Question 146 0
/ 1 pts

From the list of finishes, what would be the best for common corridors?

 
Marble tile

orrect answer  
Granite tile

 
Ceramic tile

ou Answered  
Vinyl tile

Question 147 1
/ 1 pts

What is the recommended with for a wardrobe in a bedroom area?

https://tip.instructure.com/courses/29639/quizzes/428764 141/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

 
70 cm

Correct!  
60 cm

 
55 cm

 
45 cm

Question 148 0
/ 1 pts

What is the preferred modular dimensions for a single bed?

ou Answered  
1 x 1.8 M with 0.40 M circulatory areas on both sides of the bed

 
0.90 x 2 M with 0.40 circulatory areas on both sides of the bed

 
0.90 x 2 M with 0.40 circulatory areas on one side of the bed

orrect answer  
0.90 x 2 M with 0.40 circulatory areas on both sides of the bed with 0.50 M
at foot of bed

Question 149 0
/ 1 pts

For kitchen worktops, what is the best arrangement recommendation for a


kitchen sink?

 
Worktops at left side of sink

 
Worktops on both side of sink and cooker position

https://tip.instructure.com/courses/29639/quizzes/428764 142/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

orrect answer  
Worktops at both sides of sink

ou Answered  
Worktops at right side of sink

Question 150 0
/ 1 pts

What could be a recommended level of illumination for pedestrian


hallway?

orrect answer  
35 fc

 
20 fc

 
15 fc

ou Answered  
25 fc

Question 151 1
/ 1 pts

What critical spatial and dimensional standards must guide the design of
a proposed vehicular system?

 
Safe setback and clearances

 
Maximized on-street parking

 
Provision of basement

Correct!  
Adequate maneuvering room for various type of vehicle

https://tip.instructure.com/courses/29639/quizzes/428764 143/144
6/7/22, 7:10 PM FINAL EXAMINATION (Subject Area C) – 40%: AR 390-ARCH32S7 - Integregation Course for Architecture 1

Quiz score:
90 out of 153

https://tip.instructure.com/courses/29639/quizzes/428764 144/144

You might also like