You are on page 1of 1

CLINICAL NEUROPHYSIOLOGY LABORATORY

EVOKED POTENTIAL

PATIENT’S NAME (Last, First Middle Name) DATE/TIME OF EXAM


NICOLAS, Visitacion Urmatam Feb-23-2023 12:00 PM
PIN BIRTHDATE AGE/GENDER ROOM/BED REQUESTING PHYSICIAN
2208123270 Jul-02-1982 40Y/F 3200A/3200A PASOL, ESTEBAN ANABO M.D. (1017)

EVOKED POTENTIALS

VISUAL EVOKED POTENTIAL - PATTERN REVERSAL

FINDINGS:

Pattern Reversal stimulation of the left eye field using check size 32" with active recording
electrodes at Oz and at 5cm to each side of Oz evoked a cortical occipital potential (P100) with a
latency of 103ms and amplitude of 13.5uV. Stimulation of the right eye field likewise evoked a
P100 with a latency of 104ms at 13.8uV. Both P100 latencies are within normal limits.
Interocular latency difference is not significant. Amplitude ratio is normal.

CONCLUSION:

This is a normal Pattern Reversal (VEP) study.

EMMANUEL G. EDUARDO, M.D.


PRC#48407
Neurophysiology Consultant

This report has been electronically validated. No signature is required.

OR/CI # 0093202302000261 PRINT DATE/TIME: 02 23 2023 05:17 PM


DOCUMENT # 00930223930107 Page 1 of 1