ROAD WORKS/PAVING

CHECKLIST
Project Name: Project No.:
Subcontractor:
Road Section:
Drawing No. Rev. Page 1 of 3
CHECKING ROADWORKS/PAVING Signature for approved
Asphalt Road, Road class C Asphalt Road, Road class D
Darvari tkIS MOL Comment
Concrete Road

SUB-BASE LAYER Inspection date:

Free from obvious visual defects and leveled?

Compaction accepted?
Evd = __________> 50 MN/m² (dynamic load plate test, 1/100m, min. 2/section)
Ev2 = __________> 100 MN/m² (static load plate test, 1/section)
Laboratory test accepted?
Particle size distribution:___________ (1/section)
Survey every 12,5m in cross section done?

BASE LAYER Inspection date:

Compaction accepted?
Evd = __________> 60 MN/m² (dynamic load plate test, 1/100m, mind. 2/section)
Ev2 = __________> 120 MN/m² (static load plate test, 1/100m, mind. 2/section)

Laboratory test accepted?


Particle size distribution:__________ (1/1000m³)
Proctor values measured (1/1000m³)
Organic content: ________<5% (1/1000m³)
Survey every 12,5m and at visible changes of level in cross section done?
Layer thickness accepted?
Thickness:___________mm (1/100m, min. 2/section)
Required thickness= 300mm +/-10mm
Free from obvious visual defects and leveled?

STABILIZED LAYER Inspection date:

A Compaction accepted?
Evd = __________ > 60 MN/m² (dynamic load plate test, 1/100m, random sample)
S Ev2 = __________> 120 MN/m² (static load plate test, 1/100m, random sample)
P Laboratory test of sandy gravel 0/63 accepted?
H Grain size distribution:____________ (1/1000m³)
Proctor values measured (1/1000m³)
A Organic content: ________ <5% (1/1000m³)
Water content: _________<______% (1/day and section)
L Cement content: _________> 4% (1/day and section)
Compression strength on specimen sample ___________ >
T
Slope accepted?
Slope:_________% (random sample)
Required slope= 2,5% or acc. to road design +/-0,2%

Flatness accepted?
Flatness: ________ < 10mm (random sample with 4m straight edge)

Survey every 12,5m and at visible changes of level in cross section done?
Layer thickness accepted?
Thickness:_________mm (1/100m, min. 2/section)
Required t= 200mm +/-10mm
Free from obvious visual defects?

PRIME COAT Inspection date:

Spreded quantity accepted?


Quantity:________ > 1,5 kg/m²

Free from obvious visual defects and application accepted?


Page 2 of 3
Signature for approved
Darvari tkIS MOL Comment
ASPHALT BASE LAYER Asphalt type ____________ Inspection date:

Asphalt tests on site accepted?


Temparature truck load: _________ >150°C (each truck load)
Temparature behind asphalt paver: _________ >140°C (each truck load)
Layer thickness accepted?
Thickness:_________mm (drilling core 1/50m)
Required thickness: Class C=60mm +/-10mm, Class D=100mm +/-10mm

Installed volumen accepted?


Volume:_________< 10% (1/ section and day)

Compaction rate accepted?


Compaction rate: __________ > 98% (1/6000m² or 1/ section and day)

Laboratory test of raw asphalt mixture accepted?


Grain size distribution:___________ (1/1000m³)
Form of aggregates: ____________
Bituminous content:__________
T_R&B of recovered bitumen: __________
Density and void content on test specimen: __________
Compression strength on specimen sample: __________

Survey every 12,5m and at visible changes of level in cross section done?

Slope accepted?
Slope:_________% (random sample)
Required slope= 2,5% or acc. to road design +/-0,2%
Flatness accepted?
Flatness: ________ < 10mm (random sample with 4m straight edge)

Free from obvious visual defects?

TACK COAT Inspection date:

Spreded quantity accepted?


A Quantity:________ > 0,15-0,25 kg/m²

Free from obvious visual defects and application accepted?


S
P 2ND ASPHALT LAYER Asphalt type ____________ Inspection date:

H Asphalt tests on site accepted?


Temparature truck load: _________ °C >150°C (each truck load)
A Temparature behind asphalt paver: _________ °C >140°C (each truck load)

L Layer thickness accepted?


Thickness:_________mm (drilling core randon sample)
T Required t:40mm +/-10mm
Installed volumen accepted?
Volume:_________< 15% (1/ section and day)
Void content accepted?
Void:_________ (1/6000m² or 1/ section and day)
Compaction rate accepted?
Compaction rate: __________ > 98% (1/6000m² or 1/ section and day)
Bond between layers accepted?
Bond: __________ > 12 kN (drilling core 1/6000m² or 1/ section and day)

Laboratory test of raw asphalt mixture accepted?


Grain size distribution:___________ (1/1000m³)
Form of aggregates:_____________
Bituminous content:___________
T_R&B of recovered bitumen: ____________
Elastic recovery of the recovered polymeremodified bitumen: __________
Density and void content on test specimen: ___________

Survey every 12,5m and at visible changes of level in cross section done?

Slope accepted?
Slope:_________% (random sample)
Required slope= 2,5% +/-0,2%
Flatness accepted?
Flatness:_________ < 4mm (random sample)
Grip accepted?
Grip:_________% (1/100m)
Required grip= 0,56 µSKM (Tolerance: -0,03)
Asphalt joints accepted?
Hot-cold joint is clean
cold-cold joint is cutted and clean (before sealing)
cold-cold joint is properly sealed (after sealing)

Free from obvious visual defects?


Page 3 of 3
Signature for approved
Darvari tkIS MOL Comment

CONCRETE ROADS Inspection date:

Concrete Slump test on site passed?


Flow spread of slump test:__________________mm
Required flow spread: 350-410mm (Consistency class F2)
Laboratory test passed?
Compresive strength: _________>

Survey every 25m in cross section done?

Road level accepted?


C
O Free from obvious visual defects?

N OPEN DITCH LINING Inspection date:


C
Concrete Slump test on site passed?
R Flow spread of slump test:__________________mm
E Required flow spread: 350-410mm (Consistency class F2)

T Laboratory test passed?


Compresive strength: _________>
E
Connection between gully trap and manhole is watertight and installed correctly?

Survey check done and execution accepted?

Free from obvious visual defects?

PRE CASTED CURBSTONES Inspection date:

Free from obvious visual defects?

Survey check done and execution accepted?

SHOULDER (BANQUET) Inspection date:

Compaction accepted?
Evd = __________ > 40 MN/m² (dynamic load plate test, 1/100m, random sample)
Ev2 = __________> 80 MN/m² (static load plate test, 1/100m, random sample)
Laboratory test accepted?
Grain size distribution:___________ (1/1000m³)
Proctor values measured (1/1000m³)
Organic content: ________ <5% (1/1000m³)

Free from obvious visual defects?

SIGNING AND MARKING Inspection date:

Execution accepted?