DEEP CYCLE

DEEP CYCLE AGM BATTERY

LDC6-400-L16 BCI Group 903

Features & Benefits


True deep cycle AGM technology-GREEN SOLUTION
Over 99.99% virgin lead for grid plate and active material
Heavy duty grid/paste design for deep cycle application
Maintenance free, non-spillable, valve-regulated
Double separator configuration:long cycle life &
High energy density and super anti-vibration design
Low self-discharge for longer shelf life

Electrical Specifications
Capacity (AH) Reserve Capacity (Min)
Voltage(V)
100HR 20HR 10HR 5HR 3HR @25A @56A @75A

6 435 400 375 342 320 925 / 265

Physical Specifications

Dimensions (mm/inches)
Model Weight (kg/Ibs) Terminal Type Case Material
Length Width Height Total Height (Standard)

LDC6-400-L16 295 (11.61) 180 (7.09) 406 (15.98) 428 (16.85) 54.2 (119.5) DT-5/16 PP

Operating Temperature Range

Discharge Charge Storage

-15℃~50℃(5 F~122 F) 0℃~40℃(32 F~104 F) -15℃~40℃(5 F~104 F)

MEMBER
LDC6-400-L16
Dimensions
DT-5/16 Terminal

D 5/16"

17
22

20
406±2
428±2
DEEP CYCLE AGM BATTERY

180±2
30 24

295±2
37.5 ±0.1

0 0
Note: D:Positive 19.5 -0.3 , D:Negative 17.9-0.3 ; Terminal Torque Values in-Ib(Nm) :176-203(20-23)

Performance Characteristics

LEOCH LDC AGM Charging Profile Relationship of OCV and State Of Charge (25℃,77℉)

2.20
Voltage O O Current
(V/Cell)
(25 C,77 F) (xCA)
2.15

2.10
2.6 2.58V
Battery voltage (V/cell)

2.47V 2.47V 0.25


2.40V 2.05
2.4
2.30V 0.20
CHARGED VOLTAGE 2.00
2.2 0.15-0.18C a (A)
0.15
1.95
2.0 2.0V
0.1-0.12C a (A) 0.10
1.90
CHARGE CURRENT
1.8 0.05C a (A)
0.05
0.05C a (A)
0.01C a (A) 1.85
0 0 0 10 20 30 40 50 60 70 80 90 100
t1≦0.5h t2≦6h t3≦2h t4≦2h t5≦2h tfloat(No limited)
Charging time (hours) State of Charge(%)

Cycle life in relation to Depth Of Discharge Self-discharge Characteristic

120
100 No supplementary
charge required(Carry
100 90 out supplementary
charge before use if
0 o C / 32℉ 100% capacity is required
80 80
Capacity(%)
Capacity(%)

Supplementary charge
70 required before use to
60 recover full capacity.
50
80%DOD 50%DOD 30%DOD 60
40 20 o C / 68℉ Supplementary charge
o o may often fail to recover
40 C / 104℉ 30 C / 86℉
the capacity. The battery
50 should never be left
20
standingtill this is
reached.
40
0 2 4 6 8 10 12 14 16 18 20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200
Storage time(months) The Max storage time shouldn’t be above 15 months
Average Cycles Expected

LEOCH INTERNATIONAL SALES OFFICE:


Add: 5th Floor, Xinbaohui Bldg.
Nanhai Blvd, Nanshan, Shenzhen, China. 518054
Tel: +86-755-86036060(100 lines)Fax: +86-755-26067269
E-mail: export@leoch.com
web:www.leoch.com
© 2018 LEOCH. All rights reserved.Trademarks and logos are the property of LEOCH and its affiliates unless otherwise noted.Subject to revisions without prior notice. Publication No: LB-LDC-PD-EN-V1.0-201807