VFD-PU06 Digital Keypad Instruction Sheet


 Description of the Digital keypad VFD-PU06
LED Display
Frequency Command Indicates frequency, voltage, current, user
Status indicator defined units, read, and save, etc.
F
Output Frequency H
Status indicator Model Number
U
User Defined Units VFD-PU06
Status indicator Status Display
EXT PU Display the driver's current status.
JOG
By pressing JOG key,
Jog frequency operation. MODE
Change between different display mode.
UP and DOWN Key
Set the parameter number JOG PU
and changes the numerical
data, such as Master Frequency.

Left Key Right key


Move cursor to the left. Move the cursor to the right

FWD/REV Key
Select FWD/REV operation.
STOP STOP/RESET
RUN RESET Stops AC drive operation and reset the drive
after fault occurred.
RUN Key
Start AC drive operation.

 Explanation of Display Message


Display Message Descriptions

The AC motor drive Master Frequency Command.

The Actual Operation Frequency present at terminals U, V, and


W.

The custom unit (u)

The output current present at terminals U, V, and W.

Press to change the mode to READ. Press PROG/DATA


for about 2 sec or until it’s flashing, read the parameters of AC
drive to the digital keypad PU06. It can read 2 groups of
parameters to PU06. (read 0 - read 1)
Press to change the mode to SAVE. Press PROG/DATA
for about 2 sec or until it’s flashing, then write the parameters
from the digital keypad PU06 to AC drive. If it has saved, it will
show the type of AC motor drive.
Display Message Descriptions

The specified parameter setting.

The actual value stored in the specified parameter.

External Fault

“End” displays for approximately 1 second if the entered input


data have been accepted. After a parameter value has been
set, the new value is automatically stored in memory. To modify
an entry, use the
or keys.

“Err” displays if the input is invalid.

Communication Error. Please check the AC motor drive user


manual (Chapter 5, Group 9 Communication Parameter) for
more details.

 Operation Flow Chart


VFD-PU06 Operation Flow Chart

Or

XX Press UP key to select


SAVE or READ.
Press PROG/DATA for
about 2 seconds or until
it is flashing, then save
XX-XX parameters from PU06 to
AC drive or read parameters
from AC drive to PU06.

XXXXX

-ERR- -END-
Program Program
Error Successful