You are on page 1of 3

PIPE LENGTH VARIATON

LENGTH
SI.NO. MANOLE REF M.H. DEPTH PIPE DIA 160 MM 250 MM

1 SMH-58-L.ST 250 MM -28.00


2 SMH-58-59 250 MM 29.00
3 SMH-59-60 250 MM 34.00
4 SMH-60-61 250 MM 33.00
5 SMH-61-62 250 MM 45.00
6 SMH-62-63 250 MM 35.00
7 SMH-63-L.ST 250 MM 30.00

TOTAL 178.00
BREAKDOWN ITEMS FOR SEWERAGE WATER PIPE
rate Amount
SI no. DESCRIPTION Qty unit
(AED) (AED)
Supply and lay 250mm diameter
1 GRP pipe including future 178.00 m 156 27,768.00
connection

2 Excavation for 250mm dia pipe 1844.74 m3 29 53,497.37

3 Backfill for 250mm dia pipe 1735.71 m3 68 118,028.40

4 Cartaway for 250mm dia pipe 1844.74 m3 29 53,497.37

5 Natural Gravel (5-10 mm) 109.03 m3 136 14,827.40

6 Geotextile membrane 560.70 m3 4 2,242.80

7 Non detectable warning tape 178.00 m 2 356.00

TOTAL
270,217.33
AMOUNT
250mm diameter pipe SMH58 to SMH63 see attached drawing for reference
H D Y W A h1 h2 Sectional Area 1 ( m2 ) Sectional Area 2 ( m2 ) Length Total Vol.
as per drawing as per drawing ( m3)
Excavation & LENGTH ex depth (m) difference average depth D>350mm;
1 MH NO. LEVAL
Cartaway (L) =(L / 250) (m) (m) Y=150mm / (W x h1) ((A+W)/2) x h2)
Trench Total Depth = D<350mm; Trench Width = Extra Trench Width Trench Depth 1 = Trench Depth 2 =
(Ave. depth +D+ Y) pipe diameter Y=200mm ((Dx1.5m)+500mm) = (W + h2) (300mm+D+Y) (H-h1) (X) (Y) (Z) (( X )+( Y ))x( Z )
SMH-58 3.70 29 0.116 3.70
SMH-59 3.816 34 0.136 4.052 4.327 0.25 0.15 0.875 4.502 0.7 3.627 0.6125 9.7511895 178 1844.74
SMH-60 3.952 33 0.132
SMH-61 4.084 45 0.18
SMH-62 4.264 35 0.14
SMH-63 4.404 0 4.404

TOTAL (A) 1844.74

250mm diameter pipe SMH58 to SMH63 see attached drawing for reference
H D Y W A h1 h2 Sectional Area 1 ( m2 ) Sectional Area 2 ( m2 ) Length Total Vol.
as per drawing as per drawing ( m3)
LENGTH ex depth (m) difference average depth D>350mm;
1 Back filling MH NO. LEVAL
(L) =(L / 250) (m) (m) Y=150mm / (W x h1) ((A+W)/2) x h2)
Trench Total Depth = D<350mm; Trench Width = Extra Trench Width Trench Depth 1 = Trench Depth 2 =
(Ave. depth + Y) pipe diameter Y=200mm ((Dx1.5m)+500mm) = (W + h2) (300mm+D+Y) (H-h1) (X) (Y) (Z) ( Y )x( Z )
SMH-58 3.70 29 0.116 3.70
SMH-59 3.816 34 0.136 4.052 4.327 0.25 0.15 0.875 4.502 0.7 3.627 0.6125 9.7511895 178 1735.71
SMH-60 3.952 33 0.132
SMH-61 4.084 45 0.18
SMH-62 4.264 35 0.14
SMH-63 4.404 0 4.404

TOTAL (A) 1735.71

250mm diameter pipe SMH58 to SMH63 see attached drawing for reference
H D Y W A h1 h2 Sectional Area 1 ( m2 ) Length Total Vol.
as per drawing ( m3)
LENGTH ex depth (m) difference average depth D>350mm;
1 Natural Gravel MH NO. LEVAL
(L) =(L / 250) (m) (m) Y=150mm / (W x h1)
Trench Total Depth = D<350mm; Trench Width = Extra Trench Width Trench Depth 1 = Trench Depth 2 =
(Ave. depth + Y) pipe diameter Y=200mm ((Dx1.5m)+500mm) = (W + h2) (300mm+D+Y) (H-h1) (X) (Z) ( X )x( Z )
SMH-58 3.70 29 0.116 3.70
SMH-59 3.816 34 0.136 4.052 4.327 0.25 0.15 0.875 4.502 0.7 3.627 0.6125 178 109.03
SMH-60 3.952 33 0.132
SMH-61 4.084 45 0.18
SMH-62 4.264 35 0.14
SMH-63 4.404 0 4.404

TOTAL (A) 109.03

250mm diameter pipe SMH58 to SMH63 see attached drawing for reference

H D Y W A h1 h2 Permeter Length 1 ( m ) Length Total Area.


as per drawing ( m2)
Geotextile LENGTH ex depth (m) difference average depth D>350mm;
1 MH NO. LEVAL
Sepration layer (L) =(L / 250) (m) (m) Y=150mm / 2*(W + h1)
Trench Total Depth = D<350mm; Trench Width = Extra Trench Width Trench Depth 1 = Trench Depth 2 =
(Ave. depth + Y) pipe diameter Y=200mm ((Dx1.5m)+500mm) = (W + h2) (300mm+D+Y) (H-h1) (X) (Z) ( X )x( Z )

SMH-58 3.70 29 0.116 3.70


SMH-59 3.816 34 0.136 4.052 4.327 0.25 0.15 0.875 4.502 0.7 3.627 3.15 178 560.70
SMH-60 3.952 33 0.132
SMH-61 4.084 45 0.18
SMH-62 4.264 35 0.14
SMH-63 4.404 0 4.404

TOTAL (A) 560.70

You might also like