You are on page 1of 18

FF00001OF

‫خن‬ BAR BENDING SCHEDULE


TOTAL
MEMBER TYPE SIZE NUMBER OF BARS/MEMBER NUMBER OF TOTAL Nos. LENGTH OF SHAPE CODE
MEMBERS (Nos.) BARS BAR (mm) (BS 8666:2000)

STRIP FOOTING

BOTTOM REINFORCEMENT
0.000
Long Span
T 16 1 14 14 BARS 14 6850 21
1.578 Longitudinal
Short Span
T 16 1 14 14 BARS 14 5150 21
1.578 Longitudinal
Long Span
Transverse T 16 1 66 66 BARS 66 1550 21
1.578
Short Span
Transverse T 16 1 50 50 BARS 50 1550 21
1.578
TOP REINFORCEMENT
0.000
Long Span
T 16 1 14 14 BARS 14 6825 21
1.578 Longitudinal
Short Span
T 16 1 14 14 BARS 14 5125 21
1.578 Longitudinal
Long Span
Transverse T 16 1 66 66 BARS 66 1525 21
1.578
Short Span
Transverse T 16 1 50 50 BARS 50 1525 21
1.578
DOWEL-BARS
0.000
ANCHOR T 16 1 1 1 BAR 1 1300 0
1.578

*Specifies Multiple Of 5mm -**Specifies Multiple Of 25mm


FF00002OF

A B C WEIGHT OF
(mm) (mm) (mm) REBAR (Kg) BS 8666:2000 Bending Dimensions and Scheduling of Bars for Reinforcement of
Concrete

└ ──── ┘ Strip Footing


250 6350 250 151
Footing depth = 400mm
250 4650 250 114
Footing width = 1200mm
250 1050 250 161
Spacing = 200mm
250 1050 250 122
Clear Cover = 75mm

┌ ──── ┐ Rebar Diameter (mm) Weight (Kg)

250 6318 250 151 ⌀10 0

250 4618 250 113 ⌀12 0

250 1018 250 159 ⌀16 1094

250 1018 250 120 Total Weight =


(Tons) 1.094

────
Total Weight with loss =
(Tons) 1.204

1300 0 0 2

*Specifies Multiple Of 5mm -**Specifies Multiple Of 25mm


The values for minimum radius and end projection, r and P respectively, as specified in Table 2, shall apply to all
shape codes.

The dimensions in parentheses are the free dimensions. If the shape given in the table is required but a different
dimension is to allow for possible deviations, the shape shall be drawn out and given the shape code 99 and the free
dimension shall be indicated in parentheses.

The straight length between two bends shall be at least 4d, see figure 6.

NOTE 1 The length equations for shape codes 14, 15, 25, 26, 27, 28, 29, 34, 35, 36 and 46 are approximate and where
the bend angle is greater than 45º, the length should be calculated more accurately allowing for the difference
between the specified overall dimensions and the true length measured along the central axis of the bar. When the
bending angles approach 90º, it is preferable to specify shape code 99 with a fully dimensioned sketch.

NOTE 2 Five bends or more might be impractical within permitted tolerances.

NOTE 3 For shapes with straight and curved lengths (e.g. shape codes 12, 13, 22, 33 and 47) the largest practical
mandrel size for the production of a continuous curve is 400 mm. See also Clause 10.

NOTE 4 Stock lengths are available in a limited number of lengths (e.g. 6 m, 12 m).

Dimension A for shape code 01 should be regarded as indicative and used for the purpose of calculating total length.

Actual delivery lengths should be by agreement with the supplier. See also the footnote to Table 5.
, shall apply to all

ed but a different
code 99 and the free

pproximate and where


r the difference
of the bar. When the
sketch.

e largest practical

lculating total length.

e 5.
BAR SHAPE CODE
00
01
###
###
###
###
###
###
###
###
###
###
###
###
###
###
###
###
###
###
###
###
###
###
###
###
###
###
###
###
###
###
###
98
###
99A
99B
99C
99D
99E