Professional Documents
Culture Documents
Provide, supply and install project mobile sign boards as per TPD
E building permits section standards and regulations to be shifted A279.2 No 20
between different sites as per Engineer/Client Instructions.
200,000.0 200,000.0
15,000.0 360,000.0
20,000.0 20,000.0
6,000.0 6,000.0
5,000.0 100,000.0
10,000.0 240,000.0
6,000.0 144,000.0
DIVISION 01 - DEMOLISION
EXCAVATION
The following items are for earthworks required below the ground
slab formation levels.
Excavate in any type of soil to reach the foundation formation level,
the work shall include removing any obstacles or rocks if any and
supporting excavation sides and all required works to complete the
work as per specifications and drawings and as directed by the
Engineer.
H Excavate through the Existing ground to foundation levels. E290.1 m3 2317.48 18.0 41,714.6
BACKFILLING
CONTINUED
Termite Control
Allow for Anti-Termite treatment to foundations, slabs, and 20cm
A X900.1 m2 656.73
perimeter areas for guard rooms, control rooms and electrical
rooms.
DIVISION 03 - CONCRETE
H Column H900.5 m3
I Beams H900.6 m3
K Parapet H900.8 m3
CARRIED TO COLLECTION
GE NO - B/2
RATE AMOUNT
(AED) (AED)
3.0 1,970.2
392.0 25,844.6
392.0 1,960.0
1,416.0 157,685.8
1,673.0 2,760.5
1,673.0 -
1,416.0 -
1,802.0 -
1,802.0 -
3,218.0 -
2,060.0 -
35.0 686.4
CONTINUED
PRECAST CONCRETE -
Supply and erect Precast boundary panels & columns for the front
elevation as per drawings and as follows:
Panels dimension : 115cm height (95cm height above ground level
& 20cm height below ground level).
Columns and cap dimension : 270cm height above ground for
A foundation level. H450.1 L.m 84.5
Refer to structural drawings.
Complete including erection, foundations, panels, columns, column
caps, dowels, grouting, sealant, service sleeves and electrical
conduits, junction boxes, and ducts. All as per drawings and
specifications to complete the work.
Supply and erect Precast boundary panels & columns, for the front
elevation as per drawings and as follow:
Panels dimension : 240cm height ( 220cm height above ground &
20cm height
below ground level).
Columns and cap dimension : 270cm height above ground for
B H450.2 L.m 430.8
foundation level.
Ref. to structural drawings.
Complete including erection, foundations, panels, columns, column
caps, dowels, grouting, sealant, service sleeves, electrical conduits,
junction boxes, and ducts. All as per drawings and specification to
complete the work.
Supply and erect super structure Precast External wall & parapet
panels for the Guard Room as per drawings and to the following :
Wall & parapet panels height : 420cm
Wall & parapet panels perimeter : 1940cm
C H900.9 m2
Complete including erection, panels, columns, parapet, dowels,
grouting, sealant, service sleeves, electrical conduits, junction
boxes, and ducts. All as per drawings and specification.
Ref. to structural drawings.
Supply and erect super structure Precast External wall & parapet
panels for the Admin & Control Room as per drawings and to the
following :
Wall & parapet panels height : 420cm
D Wall & parapet panels perimeter : 1940cm H900.10 m2
Complete including erection, panels, columns, parapet, dowels,
grouting, sealant, service sleeves, electrical conduits, junction
boxes, and ducts. All as per drawing and specification.
Ref. to structural drawings.
CARRIED TO COLLECTION
GE NO - B/3
RATE AMOUNT
(AED) (AED)
685.0 57,882.5
981.0 422,614.8
502.0 -
501.0 -
290.0 -
290.0 5,336.0
DIVISION 04 - MASONRY
DIVISION 05 - METALS
METAL FABRICATIONS
Specification Section 05500
Supply and fix decorative galvanized steel window grill size 3100X
1700mm height above precast concrete panels at front side as
per drawings Complete including 40x40x2mm thick poder coated
E galvanized steel frames and minimum 4mm thick laser cut M900.1 No. 1
decorative powder coated galvanized steel sheet, with all necessary
fittings and fixing accessories, bolting, as detailed in archititural
drawings. Color to selection of Engineer architect.
Supply and fix decorative galvanized steel Main Gate size 4000X
2200mm height at front side as per drawings Complete including
50x50x2mm thick powder coated galvanized steel frames and
F minimum 6mm thick laser cut decorative powder coated galvanized M900.2 No. 1
steel sheet, with all necessary fittings and fixing accessories, bolting
as detailed in archititural drawings. Color to selection/approval of
Engineer architect.
Supply and fix decorative galvanized steel Main Gate size 6000X
2200mm height at front side as per drawings Complete including
50x50x2mm thick galvanized steel frames and minimum 6mm thick
G M900.3 No. 0
laser cut decorative powder coated galvanized steel , all necessary
fittings and fixing accessories, bolting as detailed in archititural
drawings. Color to selection/approval of Engineer architect.
Supply and fix decorative galvanized steel Main Gate size 3000X
2200mm height at front side as per drawings Complete iincluding
50x50x2mm thick poder coated galvanized steel frames and
H minimum 6mm thick laser cut decorative powder coated galvanized M900.4 No. 0
steel sheet, with all necessary fittings and fixing accessories, bolting
as detailed in architectural drawings. Color to selection/approval of
Engineer architect.
CARRIED TO COLLECTION
GE NO - B/4
RATE AMOUNT
(AED) (AED)
91.0 -
72.0 -
55.0 924.0
531.0 44,869.5
2,198.0 2,198.0
3,942.0 3,942.0
6,016.0 -
3,110.0 -
CONTINUED
Supply and fix decorative galvanized steel Main Gate size 2000X
2200mm height at front side as per drawings Complete iincluding
50x50x2mm thick powder coated galvanized steel frames and
B minimum 6mm thick laser cut decorative powder coated galvanized M900.6 No. 0
steel sheet , with all necessary fittings and Fixing accessories,
bolting as detailed in archititural drawings. Color to
selection/approval of Engineer architect.
Kitchen Cabinet
BELOW-GRADE WATERPROOFING
Polythene sheeting laid on compacted fill.
SUB-STRUCTURE WATERPROOFING
Supply and applying of 3 coats of SBS elastomeric cold applied
bitumen water proofing coating (Single Modified Component Poly-
urethane) for substructure as detailed in drawings and
specificationsas and to manufacturer's recommendations.
H For Foundations and neck column, tie beams, retaining walls etc. W900.5 m2
CARRIED TO COLLECTION
GE NO - B/5
RATE AED AMOUNT AED
1,285.0 1,285.0
2,073.0 -
299.0 -
8,173.0 8,173.0
1,701.0 3,402.0
625.0 1,250.0
3.0 1,962.7
43.0 -
CONTINUED
2 coats of Cold applied bitumen emulsion coating for Toilet and wet
A W190.1 m2 3.5
areas floor.
D Ditto 30cm wide skirting membrane strips for roof. W390.3 L.m. 18
4x4 cm sand cement triangular fillet for corners in roof areas as per
G W390.6 L.m. 18
detailed drawings.
CARRIED TO COLLECTION
GE NO - B/6
RATE AED AMOUNT AED
30.0 105.0
11.0 215.7
42.0 823.6
64.0 1,152.0
4.0 78.4
59.0 1,157.0
14.0 252.0
C AD-01 - 900 X 2200 MM with louver- for electrical room M900.12 No. 0
DIVISION 09 - FINISHES
Plaster
Flooring Finishes
Ceramic Walls
Ceramic Skirting
CARRIED TO COLLECTION
GE NO - B/7
RATE AED AMOUNT AED
1,931.0 1,931.0
1,770.0 1,770.0
1,866.0 -
2,607.0 2,607.0
1,352.0 1,352.0
644.0 1,288.0
42.0 3,209.6
49.0 960.9
53.0 -
100.0 1,020.0
91.0 600.6
283.0 792.4
105.0 -
105.0 3,511.2
20.0 256.0
19.0 -
CONTINUED
Roof Finishes
Roof Skirting
Wall Paint
Ceiling Paint
CARRIED TO COLLECTION
RATE AED AMOUNT AED
106.0 2,078.7
19.0 342.0
23.0 602.1
23.0 234.6
28.0 184.8
33.0 -
71.0 426.0
79.0 1,975.0
75.0 3,750.0
CONTINUED
Maintenance Works
Cutting/Removal/Demolish
Removing the loose, flake & free worn out concrete parts from the concrete
C surface according to the approval of the engineer, and transfer of waste to the D900.4
authorized places.
Dismantling and removal of the existing Grills boundary walls and stored on site
D D900.5
where directed by the Client (APPROXIMATELY 1.9MX0.6M).
F Connect the old concrete with the new concrete using (Bonding Agent). G900.6
Install a clean, rust-free steel Dowels iron or anchoring screws into holes on the
G N900.1
surfaces of different concrete elements, 16 mm diameter.
Supply and installation of a poly modified concrete mortar ready to add water only
when used on a hard, clean, concrete surface and the price includes the removal
of paints , weak/ flake parts from the surface and clean the reinforcing steel from
H X900.3
the rust.
PATCH REPAIR using RENDEROC TG or an equivalent thickness of no more
than 5cm for the layer with the use of EPOXY PRIMER SLOW-SETTING
Supply and installation of a poly modified concrete mortar ready to add water only
when used on a hard, clean, concrete surface and the price includes the removal
J of paints , weak/ flake parts from the surface and clean the reinforcing steel from X900.4
the rust.
Micro-Concrete Repair using (Renderoc La).
Supply and installation of ready-to-use epoxy restoration mortar from three solventfree
compounds for the edges of structural elements not exposed to the sun:
K The edges of columns and the corners of the beams, thickness of up to 5 cm, with X900.5
a density not exceeding 1100 kg / M₃. Resistivity (pressure 40 Nm / M². Curvature
of 15 Nm / M²) after 7 days. The price includes the primer as recommended by the
manufacturer.
Make a circle opening in the concrete parts with a diameter of 10 to 20cm and a
L X900.5
depth of 10 to 20cm.
Two coat of Epoxy Acrylic pain system for Existing boundary surfaces undercoat
primer as per manufacturer instruction & specification including repairing plaster/
M V900.1
concrete surfaces , cracks, flake , clean and remove all the dirts, salt, all to
specifications and drawings (color/texture/pattern subject to Engineer's approval).
PAGE NO - B/9
UNIT QUANTITY RATE AED AMOUNT AED
m3 AED 276.00
m2 AED 31.00
m2 AED 276.00
m2 AED 180.00
m3 AED 6,848.00
m3 AED 9,164.00
m3 AED 13,886.00
m2 AED 66.00