L-G2
C1
M PANTRY M M M M
3.27 AREA
3.27 3.27 3.27 3.27
PB
S1
PB
T&B T&B T&B
-G2
PB
-G1
G -2F -3F -4F
-G3
DP-
DP DP DP
4.35M
2.04M
M M - 200
S2 M - 300
S2 M - 400
S2 M
2.30 2.30 PB
2.30 PB
2.30 PB
2.30 WATER
4.23M
UP TANK
C1
C1
C1
L-200
L-300
L-400
3.18M
C O R R I D O R
C O R R I D O R
C O R R I D O R
S1
2.74M
2.74M
2.74M
OWNER'S OWNER'S OWNER'S
7.43M
7.43M
7.43M
BEDROOM BEDROOM BEDROOM
C1
L-G1
C1
L-502
1.40M
PIPE CHASE CL PIPE CHASE CL PIPE CHASE CL
DP- 5F
0.93M
TOILET DN DN DN OPEN
C1
L-500
0.30M
0.30M
0.30M
0.30M
S1 S1 S1 S1 BELOW S2 S1
PB - 500
C1 C1 C1
C1
L-207
C1
L-307
C1
L-407
S1
S2 L-201
S3 L-301
S3 L-401
S3
STRIP LED LIGHTS
S3 PB - 207 S3 PB - 307 S3 PB - 407 PB - 501
S3 S3 S3
3.93M
3.93M
3.93M
3.93M
S3 S3 S3
2.31M
2.31M
2.31M
S2
3.08M
ROOM 502
STRIP LED LIGHTS
2.78M
3.08M
3.00M
CL CL CL CL
TOILET LOUNGE TOILET LOUNGE TOILET LOUNGE
& AREA & AREA & AREA
13.31M
0.46M
0.46M
0.46M
BATH ROOM 201 PB - 201
BATH ROOM 301 PB - 301
BATH ROOM 401 PB - 401
STRIP LED LIGHTS PB - 502
S3
C O R R I D O R
S3
C O R R I D O R
C1 C1 C1
S3 S2
C1
C-501
L-202 L-302 L-402
9.93M
S3 S3 S3 S3 S3 S3
STRIP LED LIGHTS
3.00M
3.00M
3.00M
3.00M
3.00M
3.00M
3.00M
3.00M
C O R R I D O R
C O R R I D O R
C O R R I D O R
CL CL CL CL
TOILET TOILET TOILET
& & &
5.39M
BATH BATH BATH
LOUNGE
ROOM 202 PB - 202 ROOM 302 PB - 302 ROOM 402 PB - 402 AREA
STRIP LED LIGHTS
S3
KOI POND
C1 C1 C1 S1
OPEN SPACE
L-203 L-303 L-403
S3 S3 S3 S3 S3 S3
STRIP LED LIGHTS
3.00M
3.00M
3.00M
3.00M
3.00M
3.00M
3.00M
CL CL CL
TOILET TOILET TOILET
& & &
BATH ROOM 203 PB - 203
BATH ROOM 303 PB - 303
BATH ROOM 403 PB - 403
1.48M
3.00M
3.00M
3.00M
3.00M
3.00M
3.00M
BATH BATH BATH
CL CL CL
C O R R I D O R
C O R R I D O R
C O R R I D O R
KOI POND
S3 S3 S3 S3 S3 S3
STRIP LED LIGHTS
S3 C1
L-204
C1
L-304
C1
L-404
C1
L-G3
3.00M
3.00M
3.00M
3.00M
3.00M
3.00M
BATH BATH BATH
CL CL CL
9.93M
S3 S3 S3 S3 S3 S3
STRIP LED LIGHTS
C1 C1 C1
S3 L-205
S2 L-305
S2 L-405
S2
0.46M
0.46M
0.46M
13.31M
S2 S2 S2
PB - ELE ELECTRICAL TOILET ROOM 206 TOILET ROOM 306 TOILET ROOM 406
ROOM & PB - 206 & PB - 306 & PB - 406
2.31M
2.31M
2.31M
3.93M
3.93M
3.93M
3.93M
S1
LOUNGE S3 S3
LOUNGE
AREA S3 S3
LOUNGE
AREA S3 S3
LOUNGE
AREA
S2 C1
CL C1
CL C1
CL
L-206 L-306 L-406
0.30M
0.30M
0.30M
S1 S1 S1 S1
7.43M
7.43M
7.43M
2.74M
2.74M
2.74M
2.30 2.30 2.30 2.30 2.30
M UP ELEV M ELEV M ELEV M ELEV M ELEV
ATOR S2 AT S2 AT S2 AT ATOR
OR OR OR
1.61M
1.61M
1.61M
8.99 8.99 8.99 8.99 8.99
M M M M M
3.38 3.42 3.42 3.42 3.42
M M M M M
1.20M 4.00M 1.30M 3.17M 1.20M 4.00M 1.30M 3.17M 1.20M 4.00M 1.30M 3.17M 9.67M
CL
ALL MATERIALS TO BE USED SHALL BE NEW AND APPROVED TYPE FOR BOTH PURPOSE AND LOCATION
INTENDED, ALL WIRE TYPES TW / THW SHALL BE INSULATED FOR 600 VOLTS AND SHALL BE INSIDE
RIGID uPVC PIPES OR METAL WIRE WAYS. ELECTRICAL TRADE SIZES SHALL BE USED (A MIN. OF 20mm
Ø FOR CONDUITS) ALL CIRCUIT BREAKERS SHALL BE BOLT-ON TYPE & INSIDE FACTORY ENCLOSURES.
NO BRANCH CIRCUIT SHALL HAVE A LOAD OF MORE THAN 80% OF ITS RATING.
ELECTRICAL SERVICE REQUIREMENTS SHALL BE 220V, SINGLE PHASE, 60 HERTZ
ALL ELECTRICAL WORKS AND INSTALLATIONS SHALL BE DONE UNDER THE DIRECT SUPERVISION
OF A LICENSED ELECTRICAL ENGINEER AND TO BE REPORTED IN DETAILS IN APPROVAL
TO THE PROJECT CIVIL ENGINEER IN CHARGE.
E
PROPOSED FIVE-STOREY COMMERCIAL (DORM) BUILDING ENGR. ERNEST NOEL SOCONG ENGR. ERNEST NOEL SOCONG 1
INSTRUCTOR INSTRUCTOR
SHT.______OF______SHTS.
1
LOCATION: BOHOL ISLAND STATE UNIVERSITY MAIN CAMPUS BOHOL ISLAND STATE UNIVERSITY