You are on page 1of 1

M M M M M

3.42 3.42 3.42 3.42 3.42


M M M M M
8.99 8.99 8.99 8.99 8.99

0.80M
1.61M

1.61M

1.61M
L-G2
C1
M PANTRY M M M M
3.27 AREA
3.27 3.27 3.27 3.27

PB
S1

PB
T&B T&B T&B

-G2
PB
-G1
G -2F -3F -4F

-G3
DP-
DP DP DP

4.35M

2.04M
M M - 200
S2 M - 300
S2 M - 400
S2 M
2.30 2.30 PB
2.30 PB
2.30 PB
2.30 WATER

4.23M
UP TANK

C1

C1

C1
L-200

L-300

L-400
3.18M

C O R R I D O R

C O R R I D O R

C O R R I D O R
S1

2.74M

2.74M

2.74M
OWNER'S OWNER'S OWNER'S

7.43M

7.43M

7.43M
BEDROOM BEDROOM BEDROOM
C1
L-G1

C1
L-502

1.40M
PIPE CHASE CL PIPE CHASE CL PIPE CHASE CL

DP- 5F
0.93M
TOILET DN DN DN OPEN

C1
L-500
0.30M

0.30M

0.30M
0.30M
S1 S1 S1 S1 BELOW S2 S1
PB - 500
C1 C1 C1
C1
L-207
C1
L-307
C1
L-407
S1
S2 L-201

S3 L-301

S3 L-401

S3
STRIP LED LIGHTS
S3 PB - 207 S3 PB - 307 S3 PB - 407 PB - 501
S3 S3 S3
3.93M

3.93M

3.93M

3.93M
S3 S3 S3

2.31M

2.31M

2.31M
S2

3.08M
ROOM 502
STRIP LED LIGHTS

STRIP LED LIGHTS

2.78M

3.08M
3.00M
CL CL CL CL
TOILET LOUNGE TOILET LOUNGE TOILET LOUNGE
& AREA & AREA & AREA

13.31M
0.46M

0.46M

0.46M
BATH ROOM 201 PB - 201
BATH ROOM 301 PB - 301
BATH ROOM 401 PB - 401
STRIP LED LIGHTS PB - 502
S3

C O R R I D O R
S3

C O R R I D O R
C1 C1 C1
S3 S2

C1
C-501
L-202 L-302 L-402

STRIP LED LIGHTS


HALLWAY

9.93M
S3 S3 S3 S3 S3 S3
STRIP LED LIGHTS

STRIP LED LIGHTS


3.00M

3.00M

3.00M

3.00M

3.00M

3.00M

3.00M

3.00M

3.00M
C O R R I D O R

C O R R I D O R

C O R R I D O R
CL CL CL CL
TOILET TOILET TOILET
& & &

5.39M
BATH BATH BATH
LOUNGE
ROOM 202 PB - 202 ROOM 302 PB - 302 ROOM 402 PB - 402 AREA
STRIP LED LIGHTS
S3
KOI POND

C1 C1 C1 S1
OPEN SPACE
L-203 L-303 L-403

STRIP LED LIGHTS

S3 S3 S3 S3 S3 S3
STRIP LED LIGHTS

STRIP LED LIGHTS


3.00M

3.00M

3.00M

3.00M

3.00M

3.00M

3.00M

3.00M
CL CL CL
TOILET TOILET TOILET
& & &
BATH ROOM 203 PB - 203
BATH ROOM 303 PB - 303
BATH ROOM 403 PB - 403
1.48M

STRIP LED LIGHTS


S3
S1

C1 STRIP LED LIGHTS

TOILET ROOM 204 TOILET ROOM 304 TOILET ROOM 404


& PB - 204 & PB - 304 & PB - 404
STRIP LED LIGHTS

STRIP LED LIGHTS


3.00M

3.00M

3.00M

3.00M

3.00M

3.00M

3.00M
BATH BATH BATH
CL CL CL

C O R R I D O R

C O R R I D O R

C O R R I D O R
KOI POND

S3 S3 S3 S3 S3 S3
STRIP LED LIGHTS
S3 C1
L-204
C1
L-304
C1
L-404

STRIP LED LIGHTS


1.20M 4.51M
HALLWAY

C1
L-G3

TOILET ROOM 205 TOILET ROOM 305 TOILET ROOM 405


& PB - 205 & PB - 305 & PB - 405
STRIP LED LIGHTS

STRIP LED LIGHTS


3.00M

3.00M

3.00M

3.00M

3.00M

3.00M

3.00M
BATH BATH BATH
CL CL CL

9.93M
S3 S3 S3 S3 S3 S3
STRIP LED LIGHTS
C1 C1 C1
S3 L-205
S2 L-305
S2 L-405
S2

0.46M

0.46M

0.46M

13.31M
S2 S2 S2

PB - ELE ELECTRICAL TOILET ROOM 206 TOILET ROOM 306 TOILET ROOM 406
ROOM & PB - 206 & PB - 306 & PB - 406

BATH BATH BATH


CL CL CL

2.31M

2.31M
2.31M
3.93M

3.93M

3.93M

3.93M
S1

LOUNGE S3 S3
LOUNGE
AREA S3 S3
LOUNGE
AREA S3 S3
LOUNGE
AREA

S2 C1
CL C1
CL C1
CL
L-206 L-306 L-406

0.30M

0.30M

0.30M
S1 S1 S1 S1

TOILET PIPE CHASE DN PIPE CHASE DN PIPE CHASE DN

7.43M
7.43M

7.43M
2.74M
2.74M

2.74M
2.30 2.30 2.30 2.30 2.30
M UP ELEV M ELEV M ELEV M ELEV M ELEV
ATOR S2 AT S2 AT S2 AT ATOR
OR OR OR

FIR FIR FIR FIR FIR


3.27 E EX 3.27 E EX 3.27 E EX 3.27 E EX 3.27 E EX
M IT M IT M IT M IT M IT

1.61M
1.61M

1.61M
8.99 8.99 8.99 8.99 8.99
M M M M M
3.38 3.42 3.42 3.42 3.42
M M M M M

1.20M 4.00M 1.30M 3.17M 1.20M 4.00M 1.30M 3.17M 1.20M 4.00M 1.30M 3.17M 9.67M

9.67M 9.67M 9.67M


1.13M 5.12M

LIGHTING OUTLET PLAN 5TH FLOOR


LIGHTING OUTLET PLAN GROUND FLOOR
LIGHTING OUTLET PLAN 2ND FLOOR LIGHTING OUTLET PLAN 3RD FLOOR LIGHTING OUTLET PLAN 4TH FLOOR

GENERAL SPECIFICATIONS : LEGEND :


ALL ELECTRICAL WORKS AND INSTALLATION SHALL BE DONE IN ACCORDANCE WITH THE LATEST
EDITION OF THE PHILIPPINE ELECTRICAL CODE, RULES AND REGULATIONS OF THE NATIONAL AUTHORITIES
CONCERNED IN THE IMPLEMENTATION OF ELECTRICAL LAWS AND ORDINANCES
AND THE LOCAL AND POWER UTILITY AND TELEPHONE COMPANIES.

CL
ALL MATERIALS TO BE USED SHALL BE NEW AND APPROVED TYPE FOR BOTH PURPOSE AND LOCATION
INTENDED, ALL WIRE TYPES TW / THW SHALL BE INSULATED FOR 600 VOLTS AND SHALL BE INSIDE
RIGID uPVC PIPES OR METAL WIRE WAYS. ELECTRICAL TRADE SIZES SHALL BE USED (A MIN. OF 20mm
Ø FOR CONDUITS) ALL CIRCUIT BREAKERS SHALL BE BOLT-ON TYPE & INSIDE FACTORY ENCLOSURES.

NO BRANCH CIRCUIT SHALL HAVE A LOAD OF MORE THAN 80% OF ITS RATING.
ELECTRICAL SERVICE REQUIREMENTS SHALL BE 220V, SINGLE PHASE, 60 HERTZ

ALL ELECTRICAL WORKS AND INSTALLATIONS SHALL BE DONE UNDER THE DIRECT SUPERVISION
OF A LICENSED ELECTRICAL ENGINEER AND TO BE REPORTED IN DETAILS IN APPROVAL
TO THE PROJECT CIVIL ENGINEER IN CHARGE.

SEAL PROJECT TITLE RECOMMENDING APPROVAL: APPROVED: REVISION SHEET NO.

E
PROPOSED FIVE-STOREY COMMERCIAL (DORM) BUILDING ENGR. ERNEST NOEL SOCONG ENGR. ERNEST NOEL SOCONG 1
INSTRUCTOR INSTRUCTOR
SHT.______OF______SHTS.
1
LOCATION: BOHOL ISLAND STATE UNIVERSITY MAIN CAMPUS BOHOL ISLAND STATE UNIVERSITY