Prepared By:
Hodge Design Associates, P.C.
22 Chestnut Street
Evansville, Indiana 47713-1022
812.422.2558 812.422.3337 (FAX)
www.hodgedesign.com
Project No. 04G-9999
12 July, 2004
Per your request, we have performed a structural analysis for the referenced antenna
tower. The purpose of the analysis was to investigate the structural adequacy of the tower for the
existing configuration (antennas, transmission lines and other appurtenances) under ice and wind
loading conditions with the addition of two, 8’diameter high performance dish antennas with
transmission lines at 200’ AGL.
Our structural analysis of the antenna tower is based on data provided by ABC Tower
and Tower Maintenance, Inc. and manufacturers' product data (please see Appendix A). We
assume that the data is correct. Structural analysis computations were performed utilizing
specialized computer software and the TIA-EIA-222-F Structural Standards for Steel Antenna
Towers and Antenna Supporting Structures. Please see Appendices B, C and D for structural
calculations.
Our structural analysis of the antenna tower indicates that the antenna tower is in
conformance with the referenced design standard for the proposed configuration. The antenna
tower structural analysis may be summarized as follows:
H O D G E D E SI G N A S S O C I A T E S, P.C.
22 Chestnut Street• Evansville, Indiana 47713-1022• tel: 812.422.2558 • fax: 812.422.3337 • www.hodgedesign.com
12 July, 2004
Mr. John Smith
ABC TOWER AND TOWER MAINTENANCE, INC.
123 Main Street
St, Louis, Missouri 99999
Re: Structural Analysis Report
300’ Guyed Antenna Tower
Henderson, Henderson County, Kentucky
HDA Project No. 04G-9999
Page 3
APPURTENANCE LIST
Elevation
(AGL) Appurtenances Transmission Lines
EXISTING
300’ FAA Beacon 2’ Rigid Conduit
300’ 6’ Lightning Rod
295’ (12) DB858 w/12’ T Frames (3 Sections) (12) 1 5/8
280’ (12) DB858 w/12’ T Frames (3 Sections) (12) 1 5/8
260’ (12) DB858 w/12’ T Frames (3 Sections) (12) 1 5/8
200’ Dual Obstruction Lights
100’ Dual Obstruction Lights
PROPOSED
200’ (2) UHX8-59 (2) EW 63
Please review the above appurtenance loading and contact us immediately if any discrepancies are
noted. This listing represents our understanding of the appurtenance loading required.
12 July, 2004
Mr. John Smith
ABC TOWER AND TOWER MAINTENANCE, INC.
123 Main Street
St, Louis, Missouri 99999
Re: Structural Analysis Report
300’ Guyed Antenna Tower
Henderson, Henderson County, Kentucky
HDA Project No. 04G-9999
Page 4
foundation reactions exceed the design reactions. We recommend that the foundation be further
investigated based on geotechnical information applicable for this site and the existing
foundation configurations.
This analysis report has been prepared without a site visit by Hodge Design Associates,
P.C. personnel. All sections, connections hardware, anchor material, etc. have been assumed to
be in good working order. Data provided by others is assumed to be correct. The opinions,
conclusions and recommendations contained in this report pertain only to the computer analysis
of the tower structure and the load carrying capacity of its members. It is the responsibility of
the tower owner, property manager or other responsible party to ensure that the tower is in good
working order and that the data provided by others is accurate and correct. The structural
analysis does not consider the fabrication quality, including welded and bolted connections,
except as specifically addressed in this report. If the structure has been altered or is different
from the tower depicted herein, Hodge Design Associates, P.C. should be informed immediately.
Hodge Design Associates, P.C. makes no warranties, expressed or implied in connection with
this report and disclaims any liability arising from the original design, material, fabrication and
erection deficiencies for this tower. The maximum liability of Hodge Design Associates, P.C.
pursuant to this report shall be limited to the total fee received for the preparation of this report.
If you have any questions regarding this matter, please do not hesitate to contact me.
Sincerely,
D a t a S u p p li e d B y O t h e r s
M a n u f a c t u r e r s' D a t a
APPENDIX B
E xisting A nt e nn a T o w er
3
SR 7/8
SR 7/8
290.0 ft
SR 1
N.A.
0.8
T1
5/8
EH
280.0 ft
SL
C=
37
SR 1 3/4
5'3
SR 3/4
SR 5/8
N.A.
N.A.
N.A.
-15
0.8
T2
/16
"
IT=
260.0 ft
10
%
SR 3/4
SR 3/4
250.0 ft
SR 1
N.A.
0.8
T3
1/2
EH
240.0 ft
SL
C=
R=240' R=240'
34
PLAN
5'4
SR 5/8
-9/
N.A.
N.A.
N.A.
0.9
32
T4
"
IT=
10
SR 5/8
220.0 ft
%
SeeDB858DDH65E-SX
Lightning
(4)
12'
Lighting
T-Frame
E-7 -for
Rod
Dual
Beacon
Feedlines
Sector
6'Obstruction
Mount
and Linear 300
295
280
260
200
100
0
Appurtenances
APPURTENANCES
SR 3/4
SR 3/4
210.0 ft
SR 1
N.A.
0.9
T5
200.0 ft
LC
12' T-Frame Sector Mount 295 12' T-Frame Sector Mount 260
"
0.9
T6
IT=
12' T-Frame Sector Mount 295 12' T-Frame Sector Mount 260
180.0 ft
N.A.
N.A.
0.9
T7
SR 3/4
SYMBOL LIST
0.9
T8
=2 MATERIAL STRENGTH
SR 1
N.A.
76
0.9
T9
'2-
23 GRADE Fy Fu GRADE Fy Fu
SR 5/8
/32
"
120.0 ft IT= A572-50 50 ksi 65 ksi A36 36 ksi 58 ksi
10
%
0.9
N.A.
3. Tower is also designed for a 61 mph basic wind with 0.50 in ice.
4. Deflections are based upon a 50 mph wind.
5. See Sheet E-7 for Feedlines and Linear Appurtenances.
T11
0.7
70.0 ft
SR 1
N.A.
7/16
T12
0.7
EHS
LC=
SR 5/8
248
'4-1
60.0 ft /16"
IT=1
0%
SR 1 3/4
T13
0.7
SR 5/8
40.0 ft
N.A.
N.A.
N.A.
T14
0.7
20.0 ft
B 4 @ 3.20833
T15
0.5
N.A.
33 K
6.7 ft
N.A.
N.A.
N.A.
T16
12.4 0.6
A
0.0 ft
52
1K K
40 K
Guy Low-Diagonals
R=240'
Top Guy Pull-Offs
Guy Hi-Diagonals
109 K (Axial)
Diagonal Grade
# Panels @ (ft)
Face Width (ft)
Bottom Girts
Horizontals
Weight (K)
Leg Grade
Diagonals
Top Girts
Mid Girts
Section
Legs
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Guyed Tower (HDA Project No. 04G-9999)
Project: Henderson,
22 Chestnut Street Henderson County, KY --- Existing Tower Condition Analysis
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-1
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-GT-R1.eri
TIA/EIA-222-F - 70 mph/61 mph 0.5000 in Ice
Leg Capacity Leg Compression (K)
150 100 50 <- Minimum 0 Maximum -> -50 -100 -150
300' 300'
290' 290'
280' 280'
260' 260'
250' 250'
240' 240'
220' 220'
210' 210'
200' 200'
180' 180'
Elevation (ft)
160' 160'
140' 140'
120' 120'
100' 100'
80' 80'
70' 70'
60' 60'
40' 40'
20' 20'
6'8-1/32" 6'8-1/32"
0' 0'
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Guyed Tower (HDA Project No. 04G-9999)
Project: Henderson,
22 Chestnut Street Henderson County, KY --- Existing Tower Condition Analysis
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-3
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-GT-R1.eri
TIA/EIA-222-F - 70 mph/61 mph 0.5000 in Ice Maximum Values
Vx Vz Mx Mz
290' 290'
280' 280'
260' 260'
250' 250'
240' 240'
220' 220'
210' 210'
200' 200'
180' 180'
Elevation (ft)
160' 160'
140' 140'
120' 120'
100' 100'
80' 80'
70' 70'
60' 60'
40' 40'
20' 20'
6'8-1/32" 6'8-1/32"
0' 0'
0 5 10 0 50 100
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Guyed Tower (HDA Project No. 04G-9999)
Project: Henderson,
22 Chestnut Street Henderson County, KY --- Existing Tower Condition Analysis
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-4
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-GT-R1.eri
TIA/EIA-222-F - Service - 50 mph Maximum Values
290' 290'
280' 280'
260' 260'
250' 250'
240' 240'
220' 220'
210' 210'
200' 200'
180' 180'
Elevation (ft)
160' 160'
140' 140'
120' 120'
100' 100'
80' 80'
70' 70'
60' 60'
40' 40'
20' 20'
6'8-1/32" 6'8-1/32"
0' 0'
0 5 10 15 0 0.5 0 0.5
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Guyed Tower (HDA Project No. 04G-9999)
Project: Henderson,
22 Chestnut Street Henderson County, KY --- Existing Tower Condition Analysis
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-5
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-GT-R1.eri
Guy Tensions and Tower Reactions
TIA/EIA-222-F - 70 mph/61 mph 0.5000 in Ice
Maximum Values
Anchor 'A'@240 ft Azimuth 0 deg Elev 0 ft
300.0 ft Plane through centroid of tower
290.0 ft 290'
5/8
280.0 ft
EH
S,
SF
=
2.2
8,
260.0 ft
Tm
ax
=
250.0 ft 250'
18
.59
1/2
K,
EH
240.0 ft
Lc
S,
=
SF
37
=
5'3
2.3
-15
3,
/16
Tm
220.0 ft
", L
ax
u=
=
11
210.0 ft 210' 37
.53
4'1
K,
1/2
1-2
Lc
EH
200.0 ft
9/3
=
S,
34
2",
SF
5'4
Ls
=2
-9/
=
32
.58
37
", L
,Tm
6'2
u=
180.0 ft
ax
-13
34
=
/32
10
5'5
.42
"
/8"
,
K,
Ls
Lc
=
=
34
31
160.0 ft
6'1
7'7
-19
-1/
4",
/32
Lu
"
=
31
7'3
6E
/32
HS
",
,
Ls
SF
=
= 2.8
31
6,
8'2
120.0 ft Tm
-17
ax
/32
= 7.2
"
7K
,L
c=
27
100.0 ft 6'2
-23
/32
", L
u=
27
5'1
1-1
80.0 ft 5/1
6", 2K
Ls
70.0 ft 70' = 27
7/16 6'8
EHS -5/
, SF 32
60.0 ft = 3. "
34,
Tm 40 K
ax =
6.23
K, L
c = 24
8'4- PLAN
1/16
40.0 ft ", Lu
= 24
8'1-
11/1
6", L
s = 24
8'7-
13/1
52
20.0 ft 6"
K
6.7 ft
0.0 ft 40 deg 33 K
1K R=240'
109 K (Axial)
40 K
ELEVATION
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Guyed Tower (HDA Project No. 04G-9999)
Project: Henderson,
22 Chestnut Street Henderson County, KY --- Existing Tower Condition Analysis
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-6
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-GT-R1.eri
Feedline Distribution Chart
6'8-1/32" - 300'
Round Flat App In Face App Out Face Truss Leg
300'
Face A Face B Face C 300'
290' 290'
250' 250'
240' 240'
220' 220'
210' 210'
200' 200'
180' 180'
Elevation (ft)
(12) 1 5/8
140' 140'
(12) 1 5/8
120' 120'
100' 100'
80' 80'
70' 70'
60' 60'
40' 40'
20' 20'
10' 10'
6'8-1/32" 6'8-1/32"
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Guyed Tower (HDA Project No. 04G-9999)
Project: Henderson,
22 Chestnut Street Henderson County, KY --- Existing Tower Condition Analysis
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-7
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-GT-R1.eri
Feedline Plan
(12) 1 5/8
Feedline Ladder
B
A
(12) 1 5/8
Feedline Ladder
C
er
dd
La
uit
nd
e
lin
Co
ed
gid
Fe
5/8
Ri
1
2"
2)
(1
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Guyed Tower (HDA Project No. 04G-9999)
Project: Henderson,
22 Chestnut Street Henderson County, KY --- Existing Tower Condition Analysis
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-7
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-GT-R1.eri
Stress Distribution Chart
0' - 300'
> 100% 90%-100% 75%-90% 50%-75% < 50% Overstress
300'
Face A Face B Face C 300'
290' 290'
280' 280'
260' 260'
250' 250'
240' 240'
220' 220'
210' 210'
200' 200'
180' 180'
Elevation (ft)
160' 160'
140' 140'
120' 120'
100' 100'
80' 80'
70' 70'
60' 60'
40' 40'
20' 20'
6'8-1/32" 6'8-1/32"
0' 0'
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Guyed Tower (HDA Project No. 04G-9999)
Project: Henderson,
22 Chestnut Street Henderson County, KY --- Existing Tower Condition Analysis
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-8
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-GT-R1.eri
Job Page
ERITower Structural Analysis Report -- 300' Guyed Tower (HDA Project 1 of 34
No. 04G-9999)
Project Date
Hodge Design Associates, P.C.
22 Chestnut Street Henderson, Henderson County, KY --- Existing Tower 12:34:18 07/23/04
Condition Analysis
Evansville, Indiana 47713-1022 Client Designed by
Phone: 812.422.2558 ABC Towers and Tower Maintenance Gray Hodge
FAX: 812.422.3337
The main tower is a 3x guyed tower with an overall height of 300' above the ground line.
The base of the tower is set at an elevation of 0' above the ground line.
The face width of the tower is 3' at the top and tapered at the base.
This tower is designed using the TIA/EIA-222-F standard.
The following design criteria apply:
Tower is located in Henderson County, Kentucky.
Basic wind speed of 70 mph.
Nominal ice thickness of 0.5000 in.
Ice density of 56 pcf.
A wind speed of 61 mph is used in combination with ice.
Temperature drop of 75 °F.
Deflections calculated using a wind speed of 50 mph.
See Sheet E-7 for Feedlines and Linear Appurtenances..
See Sheet E-8 for Code Check/Stress Distribution..
Pressures are calculated at each section.
Safety factor used in guy design is 2.
Stress ratio used in tower member design is 1.333.
Local bending stresses due to climbing loads, feedline supports, and appurtenance mounts are not considered.
Options
Consider Moments - Legs Distribute Leg Loads As Uniform v Treat Feedline Bundles As Cylinder
Consider Moments - Horizontals Assume Legs Pinned Use ASCE 10 X-Brace Ly Rules
Consider Moments - Diagonals v Assume Rigid Index Plate v Calculate Redundant Bracing Forces
Use Moment Magnification v Use Clear Spans For Wind Area v Ignore Redundant Members in FEA
v Use Code Stress Ratios v Use Clear Spans For KL/r v SR Leg Bolts Resist Compression
v Use Code Safety Factors - Guys v Retension Guys To Initial Tension v All Leg Panels Have Same Allowable
Escalate Ice Bypass Mast Stability Checks Offset Girt At Foundation
Always Use Max Kz v Use Azimuth Dish Coefficients v Consider Feedline Torque
Use Special Wind Profile v Project Wind Area of Appurt. v Include Angle Block Shear Check
v Include Bolts In Member Capacity Autocalc Torque Arm Areas Poles
v Leg Bolts Are At Top Of Section v SR Members Have Cut Ends v Include Shear-Torsion Interaction
v Secondary Horizontal Braces Leg v Sort Capacity Reports By Component Always Use Sub-Critical Flow
Use Diamond Inner Bracing (4 Sided) v Triangulate Diamond Inner Bracing Use Top Mounted Sockets
Add IBC .6D+W Combination
Job Page
ERITower Structural Analysis Report -- 300' Guyed Tower (HDA Project 2 of 34
No. 04G-9999)
Project Date
Hodge Design Associates, P.C.
22 Chestnut Street Henderson, Henderson County, KY --- Existing Tower 12:34:18 07/23/04
Condition Analysis
Evansville, Indiana 47713-1022 Client Designed by
Phone: 812.422.2558 ABC Towers and Tower Maintenance Gray Hodge
FAX: 812.422.3337
Wind 180
Guy A
Leg A
Wind 90
Fa
A
ce
ce
B
Fa
X
Leg C Z Leg B
Gu
yC Face C yB
Gu
Wind 0
Tower No. Mid Girt Mid Girt Mid Girt Horizontal Horizontal Horizontal
Elevation of Type Size Grade Type Size Grade
Mid
ft Girts
(36 ksi) (36 ksi)
T4 240'-220' 1 Solid Round 5/8 A36 Solid Round 5/8 A36
(36 ksi) (36 ksi)
T5 220'-200' 1 Solid Round 5/8 A36 Solid Round 5/8 A36
(36 ksi) (36 ksi)
T6 200'-180' 1 Solid Round 5/8 A36 Solid Round 5/8 A36
(36 ksi) (36 ksi)
T7 180'-160' 1 Solid Round 5/8 A36 Solid Round 5/8 A36
(36 ksi) (36 ksi)
T8 160'-140' 1 Solid Round 5/8 A36 Solid Round 5/8 A36
(36 ksi) (36 ksi)
T9 140'-120' 1 Solid Round 5/8 A36 Solid Round 5/8 A36
(36 ksi) (36 ksi)
T10 120'-100' 1 Solid Round 5/8 A36 Solid Round 5/8 A36
(36 ksi) (36 ksi)
T11 100'-80' 1 Solid Round 5/8 A36 Solid Round 5/8 A36
(36 ksi) (36 ksi)
T12 80'-60' 1 Solid Round 5/8 A36 Solid Round 5/8 A36
(36 ksi) (36 ksi)
T13 60'-40' 1 Solid Round 5/8 A36 Solid Round 5/8 A36
(36 ksi) (36 ksi)
T14 40'-20' 1 Solid Round 5/8 A36 Solid Round 5/8 A36
(36 ksi) (36 ksi)
T15 20'-6'8-1/32'' None Solid Round A36 Solid Round 5/8 A36
(36 ksi) (36 ksi)
T16 6'8-1/32''-0' None Solid Round A36 Channel C12x20.7 A36
(36 ksi) (36 ksi)
Tower Gusset Gusset Gusset Grade Adjust. Factor Adjust. Weight Mult. Double Angle Double Angle
Elevation Area Thickness Af Factor Stitch Bolt Stitch Bolt
(per face) Ar Spacing Spacing
Diagonals Horizontals
ft ft2 in in in
T11 100'-80' 0.00 0.0000 A36 1.01 1.05 1.01 36.0000 36.0000
(36 ksi)
T12 80'-60' 0.00 0.0000 A36 1.01 1.05 1.01 36.0000 36.0000
(36 ksi)
T13 60'-40' 0.00 0.0000 A36 1.01 1.05 1.01 36.0000 36.0000
(36 ksi)
T14 40'-20' 0.00 0.0000 A36 1.01 1.05 1.01 36.0000 36.0000
(36 ksi)
T15 20'-6'8- 0.00 0.0000 A36 1.01 1.05 1.01 36.0000 36.0000
1/32'' (36 ksi)
T16 6'8-1/32''- 0.00 0.0000 A36 1.01 1.05 1.01 36.0000 36.0000
0' (36 ksi)
Guy Data
Guy Guy Guy Initial % Guy Guy Lu Anchor Anchor Anchor End
Elevation Grade Size Tension Modulus Weight Radius Azimuth Elevation Fitting
Adj. Efficiency
ft K ksi plf ft ft ° ft %
290 EHS A 5/8 4.24 10% 21000 0.813 375'3/8'' 240' 0.0000 0' 100%
B 5/8 4.24 10% 21000 0.813 375'3/8'' 240' 0.0000 0' 100%
C 5/8 4.24 10% 21000 0.813 375'3/8'' 240' 0.0000 0' 100%
250 EHS A 1/2 2.69 10% 21000 0.517 345'31/32'' 240' 0.0000 0' 100%
B 1/2 2.69 10% 21000 0.517 345'31/32'' 240' 0.0000 0' 100%
C 1/2 2.69 10% 21000 0.517 345'31/32'' 240' 0.0000 0' 100%
210 EHS A 1/2 2.69 10% 21000 0.517 317'4-3/16'' 240' 0.0000 0' 100%
B 1/2 2.69 10% 21000 0.517 317'4-3/16'' 240' 0.0000 0' 100%
C 1/2 2.69 10% 21000 0.517 317'4-3/16'' 240' 0.0000 0' 100%
139.75 EHS A 7/16 2.08 10% 21000 0.399 276'1/8'' 240' 0.0000 0' 100%
B 7/16 2.08 10% 21000 0.399 276'1/8'' 240' 0.0000 0' 100%
C 7/16 2.08 10% 21000 0.399 276'1/8'' 240' 0.0000 0' 100%
70 EHS A 7/16 2.08 10% 21000 0.399 248'1-11/16'' 240' 0.0000 0' 100%
B 7/16 2.08 10% 21000 0.399 248'1-11/16'' 240' 0.0000 0' 100%
C 7/16 2.08 10% 21000 0.399 248'1-11/16'' 240' 0.0000 0' 100%
Guy Data(cont’d)
Job Page
ERITower Structural Analysis Report -- 300' Guyed Tower (HDA Project 8 of 34
No. 04G-9999)
Project Date
Hodge Design Associates, P.C.
22 Chestnut Street Henderson, Henderson County, KY --- Existing Tower 12:34:18 07/23/04
Condition Analysis
Evansville, Indiana 47713-1022 Client Designed by
Phone: 812.422.2558 ABC Towers and Tower Maintenance Gray Hodge
FAX: 812.422.3337
Guy Pressures
Guy Guy z qz qz Ice
Elevation Location Ice Thickness
ft ft psf psf in
290 A 145' 19 14 0.5000
B 145' 19 14 0.5000
C 145' 19 14 0.5000
250 A 125' 18 14 0.5000
B 125' 18 14 0.5000
C 125' 18 14 0.5000
210 A 105' 17 13 0.5000
B 105' 17 13 0.5000
C 105' 17 13 0.5000
139.75 A 69'10-9/16'' 16 12 0.5000
B 69'10-9/16'' 16 12 0.5000
C 69'10-9/16'' 16 12 0.5000
70 A 35' 13 10 0.5000
B 35' 13 10 0.5000
C 35' 13 10 0.5000
Description Face Allow Component Placement Face Lateral # # Clear Width or Perimeter Weight
or Shield Type Offset Offset Per Spacing Diameter
Leg ft in (Frac FW) Row in in in klf
Feedline A Yes Ar (CfAe) 10' - 10' 1.0000 0.25 1 1 1.5000 0.0000 0.01
Ladder
Feedline B Yes Ar (CfAe) 10' - 10' 1.0000 0.25 1 1 1.5000 0.0000 0.01
Ladder
Feedline C Yes Ar (CfAe) 10' - 10' 1.0000 0.25 1 1 1.5000 0.0000 0.01
Ladder
2'' Rigid C Yes Ar (CfAe) 300' - 10' 1.0000 -0.25 1 1 2.0000 2.0000 0.00
Conduit
1 5/8 A Yes Ar (CfAe) 300' - 10' 1.0000 0.25 12 6 0.3750 1.9800 0.00
1 5/8 B Yes Ar (CfAe) 280' - 10' 1.0000 0.25 12 6 0.3750 1.9800 0.00
1 5/8 C Yes Ar (CfAe) 260' - 10' 1.0000 0.25 12 6 0.3750 1.9800 0.00
Load Combinations
Job Page
ERITower Structural Analysis Report -- 300' Guyed Tower (HDA Project 15 of 34
No. 04G-9999)
Project Date
Hodge Design Associates, P.C.
22 Chestnut Street Henderson, Henderson County, KY --- Existing Tower 12:34:18 07/23/04
Condition Analysis
Evansville, Indiana 47713-1022 Client Designed by
Phone: 812.422.2558 ABC Towers and Tower Maintenance Gray Hodge
FAX: 812.422.3337
Comb. Description
No.
1 Dead Only
2 Dead+Wind 0 deg - No Ice+Guy
3 Dead+Wind 30 deg - No Ice+Guy
4 Dead+Wind 60 deg - No Ice+Guy
5 Dead+Wind 90 deg - No Ice+Guy
6 Dead+Wind 120 deg - No Ice+Guy
7 Dead+Wind 150 deg - No Ice+Guy
8 Dead+Wind 180 deg - No Ice+Guy
9 Dead+Wind 210 deg - No Ice+Guy
10 Dead+Wind 240 deg - No Ice+Guy
11 Dead+Wind 270 deg - No Ice+Guy
12 Dead+Wind 300 deg - No Ice+Guy
13 Dead+Wind 330 deg - No Ice+Guy
14 Dead+Ice+Temp+Guy
15 Dead+Wind 0 deg+Ice+Temp+Guy
16 Dead+Wind 30 deg+Ice+Temp+Guy
17 Dead+Wind 60 deg+Ice+Temp+Guy
18 Dead+Wind 90 deg+Ice+Temp+Guy
19 Dead+Wind 120 deg+Ice+Temp+Guy
20 Dead+Wind 150 deg+Ice+Temp+Guy
21 Dead+Wind 180 deg+Ice+Temp+Guy
22 Dead+Wind 210 deg+Ice+Temp+Guy
23 Dead+Wind 240 deg+Ice+Temp+Guy
24 Dead+Wind 270 deg+Ice+Temp+Guy
25 Dead+Wind 300 deg+Ice+Temp+Guy
26 Dead+Wind 330 deg+Ice+Temp+Guy
27 Dead+Wind 0 deg - Service+Guy
28 Dead+Wind 30 deg - Service+Guy
29 Dead+Wind 60 deg - Service+Guy
30 Dead+Wind 90 deg - Service+Guy
31 Dead+Wind 120 deg - Service+Guy
32 Dead+Wind 150 deg - Service+Guy
33 Dead+Wind 180 deg - Service+Guy
34 Dead+Wind 210 deg - Service+Guy
35 Dead+Wind 240 deg - Service+Guy
36 Dead+Wind 270 deg - Service+Guy
37 Dead+Wind 300 deg - Service+Guy
38 Dead+Wind 330 deg - Service+Guy
Maximum Reactions
Location Condition Gov. Vertical Horizontal, X Horizontal, Z
Load K K K
Comb.
Mast Max. Vert 15 109.02 0.00 0.64
Max. Hx 11 78.44 0.61 0.05
Max. Hz 15 109.02 0.00 0.64
Max. Mx 1 0.00 0.00 0.02
Max. Mz 1 0.00 0.00 0.02
Max. Torsion 22 0.32 0.33 -0.41
Min. Vert 1 56.98 0.00 0.02
Min. Hx 5 78.45 -0.60 0.05
Min. Hz 8 71.53 0.00 -0.64
Min. Mx 1 0.00 0.00 0.02
Min. Mz 1 0.00 0.00 0.02
Min. Torsion 16 -0.33 -0.21 0.52
Guy C @ 240 ft Max. Vert 10 -0.60 -0.93 0.54
Elev 0 ft
Azimuth 240 deg
Job Page
ERITower Structural Analysis Report -- 300' Guyed Tower (HDA Project 16 of 34
No. 04G-9999)
Project Date
Hodge Design Associates, P.C.
22 Chestnut Street Henderson, Henderson County, KY --- Existing Tower 12:34:18 07/23/04
Condition Analysis
Evansville, Indiana 47713-1022 Client Designed by
Phone: 812.422.2558 ABC Towers and Tower Maintenance Gray Hodge
FAX: 812.422.3337
Solution Summary
Sum of Applied Forces Sum of Reactions
Load PX PY PZ PX PY PZ % Error
Comb. K K K K K K
1 0.00 -31.78 0.00 -0.00 31.78 0.00 0.003%
2 0.00 -31.96 -28.37 0.00 31.96 28.36 0.014%
3 14.17 -31.78 -24.54 -14.17 31.78 24.53 0.010%
4 24.54 -31.60 -14.17 -24.54 31.60 14.17 0.010%
5 28.33 -31.78 0.00 -28.33 31.78 0.00 0.007%
6 24.57 -31.96 14.18 -24.56 31.96 -14.18 0.010%
7 14.17 -31.78 24.54 -14.16 31.78 -24.54 0.010%
8 0.00 -31.60 28.33 0.00 31.60 -28.34 0.010%
Job Page
ERITower Structural Analysis Report -- 300' Guyed Tower (HDA Project 18 of 34
No. 04G-9999)
Project Date
Hodge Design Associates, P.C.
22 Chestnut Street Henderson, Henderson County, KY --- Existing Tower 12:34:18 07/23/04
Condition Analysis
Evansville, Indiana 47713-1022 Client Designed by
Phone: 812.422.2558 ABC Towers and Tower Maintenance Gray Hodge
FAX: 812.422.3337
Compression Checks
T1 300 - 280 1 3/4 20' 3'3'' 89.1 1.00 17.122 2.4053 -22.43 41.18 0.545
K=1.00
T2 280 - 260 1 3/4 20' 3'3'' 89.1 1.00 17.122 2.4053 -24.27 41.18 0.589
K=1.00
T3 260 - 240 1 3/4 20' 3'3'' 89.1 1.00 17.122 2.4053 -29.82 41.18 0.724
K=1.00
T4 240 - 220 2 20' 3'3'' 78.0 1.00 19.409 3.1416 -43.25 60.98 0.709
K=1.00
T5 220 - 200 2 20' 3'3'' 78.0 1.00 19.409 3.1416 -51.40 60.98 0.843
K=1.00
T6 200 - 180 2 20' 3'3'' 78.0 1.00 19.409 3.1416 -45.97 60.98 0.754
K=1.00
T7 180 - 160 2 20' 3'3'' 78.0 1.00 19.409 3.1416 -37.40 60.98 0.613
K=1.00
T8 160 - 140 2 20' 3'3'' 78.0 1.00 19.409 3.1416 -45.64 60.98 0.749
K=1.00
T9 140 - 120 2 20' 3'3'' 78.0 1.00 19.409 3.1416 -45.65 60.98 0.749
K=1.00
T10 120 - 100 2 20' 3'3'' 78.0 1.00 19.409 3.1416 -34.40 60.98 0.564
Job Page
ERITower Structural Analysis Report -- 300' Guyed Tower (HDA Project 22 of 34
No. 04G-9999)
Project Date
Hodge Design Associates, P.C.
22 Chestnut Street Henderson, Henderson County, KY --- Existing Tower 12:34:18 07/23/04
Condition Analysis
Evansville, Indiana 47713-1022 Client Designed by
Phone: 812.422.2558 ABC Towers and Tower Maintenance Gray Hodge
FAX: 812.422.3337
K=1.00
T11 100 - 80 1 3/4 20' 3'3'' 89.1 1.00 17.122 2.4053 -34.43 41.18 0.836
K=1.00
T12 80 - 60 1 3/4 20' 3'3'' 89.1 1.00 17.122 2.4053 -35.39 41.18 0.859
K=1.00
T13 60 - 40 1 3/4 20' 3'3'' 89.1 1.00 17.122 2.4053 -40.86 41.18 0.992
K=1.00
T14 40 - 20 1 3/4 20' 3'3'' 89.1 1.00 17.122 2.4053 -42.42 41.18 1.030
K=1.00
T15 20 - 6.66667 1 3/4 13'3- 3'2- 88.0 1.00 17.365 2.4053 -41.07 41.77 0.983
31/32'' 17/32'' K=1.00
T16 6.66667 - 0 1 3/4 6'10- 1'10- 50.8 0.95 22.953 2.4053 -30.46 55.21 0.552*
11/16'' 3/16'' K=1.00
*
DL controls
*
DL controls
*
DL controls
*
DL controls
Tension Checks
T2 280 - 260 1 3/4 20' 3'3'' 89.1 30.000 2.4053 3.97 72.16 0.055
T4 240 - 220 2 20' 3'3'' 78.0 30.000 3.1416 5.30 94.25 0.056
T5 220 - 200 2 20' 3'3'' 78.0 30.000 3.1416 11.86 94.25 0.126
T2 280 - 260 3/4 4'5-1/32'' 2'1-3/16'' 134.7 21.600 0.4418 0.83 9.54 0.087
T3 260 - 240 3/4 4'5-1/32'' 2'1-3/16'' 134.7 21.600 0.4418 2.88 9.54 0.301
T4 240 - 220 5/8 4'5-1/32'' 2'1-3/32'' 160.4 21.600 0.3068 1.17 6.63 0.176
T5 220 - 200 5/8 4'5-1/32'' 2'1-3/32'' 160.4 21.600 0.3068 1.48 6.63 0.224
T6 200 - 180 5/8 4'5-1/32'' 2'1-3/32'' 160.4 21.600 0.3068 1.01 6.63 0.152
T7 180 - 160 5/8 4'5-1/32'' 2'1-3/32'' 160.4 21.600 0.3068 0.54 6.63 0.081
T8 160 - 140 5/8 4'5-1/32'' 2'1-3/32'' 160.4 21.600 0.3068 1.02 6.63 0.154
T9 140 - 120 5/8 4'5-1/32'' 2'1-3/32'' 160.4 21.600 0.3068 1.37 6.63 0.207
T10 120 - 100 5/8 4'5-1/32'' 2'1-3/32'' 160.4 21.600 0.3068 0.88 6.63 0.133
T11 100 - 80 5/8 4'5-1/32'' 2'1-3/16'' 161.6 21.600 0.3068 0.93 6.63 0.141
T12 80 - 60 5/8 4'5-1/32'' 2'1-3/16'' 161.6 21.600 0.3068 1.39 6.63 0.210
T13 60 - 40 5/8 4'5-1/32'' 2'1-3/16'' 161.6 21.600 0.3068 1.17 6.63 0.177
T14 40 - 20 5/8 4'5-1/32'' 2'1-3/16'' 161.6 21.600 0.3068 0.89 6.63 0.134
T15 20 - 6.66667 5/8 4'4- 2'1-3/32'' 160.5 21.600 0.3068 0.47 6.63 0.071
11/16''
T3 260 - 240 3/4 4'5-1/32'' 2'1-3/16'' 134.7 21.600 0.4418 0.08 9.54 0.008
T5 220 - 200 3/4 4'5-1/32'' 2'1-3/32'' 133.7 21.600 0.4418 0.87 9.54 0.091
T9 140 - 120 3/4 4'5-1/32'' 2'1-3/32'' 133.7 21.600 0.4418 0.52 9.54 0.055
T12 80 - 60 3/4 4'5-1/32'' 2'1-3/16'' 134.7 21.600 0.4418 0.24 9.54 0.025
T3 260 - 240 3/4 4'5-1/32'' 2'1-3/16'' 134.7 21.600 0.4418 2.59 9.54 0.271
T5 220 - 200 3/4 4'5-1/32'' 2'1-3/32'' 133.7 21.600 0.4418 1.08 9.54 0.113
T8 160 - 140 3/4 4'5-1/32'' 2'1-3/32'' 133.7 21.600 0.4418 0.44 9.54 0.046
T12 80 - 60 3/4 4'5-1/32'' 2'1-3/16'' 134.7 21.600 0.4418 0.22 9.54 0.023
*
DL controls
*
DL controls
*
DL controls
Job Page
ERITower Structural Analysis Report -- 300' Guyed Tower (HDA Project 30 of 34
No. 04G-9999)
Project Date
Hodge Design Associates, P.C.
22 Chestnut Street Henderson, Henderson County, KY --- Existing Tower 12:34:18 07/23/04
Condition Analysis
Evansville, Indiana 47713-1022 Client Designed by
Phone: 812.422.2558 ABC Towers and Tower Maintenance Gray Hodge
FAX: 812.422.3337
*
DL controls
Section Elevation Size Actual Actual Allow. Ratio Actual Actual Allow. Ratio
No. Mx fbx Fbx fbx My fby Fby fby
ft kip-ft ksi ksi Fbx kip-ft ksi ksi Fby
T5 220 - 200 1 0.00 0.497 27.000 0.018 0.00 0.000 27.000 0.000
T9 140 - 120 1 0.00 0.497 27.000 0.018 0.00 0.000 27.000 0.000
T12 80 - 60 1 0.00 0.497 27.000 0.018 0.00 0.000 27.000 0.000
Program Version 3.0.0.16 - 7/10/2004 File:C:/Documents and Settings/ghodge.HODGEDESIGN.000/My Documents/ERITower Project Data Files/Sample
Reports/Sample-GT-R1.eri
APPENDIX C
A nt e nn a T o w er With Propos e d A ddition al A nt e nn a s
3
SR 7/8
SR 7/8
290.0 ft
SR 1
N.A.
0.7
T1
5/8
EH
280.0 ft
SL
C=
37
SR 1 1/2
5'3
SR 3/4
SR 3/4
SR 3/4
SR 3/4
SR 3/4
N.A.
N.A.
N.A.
-15
0.7
T2
/16
"
IT=
260.0 ft
10
%
SR 3/4
SR 3/4
250.0 ft
SR 1
N.A.
0.7
T3
1/2
EH
240.0 ft
SL
C=
R=240' R=240'
34
PLAN
5'4
SR 5/8
-9/
N.A.
N.A.
N.A.
0.7
32
T4
"
IT=
10
220.0 ft
%
SeeDB858DDH65E-SX
Lightning
(4)
12'
UHX8-59
Lighting
T-Frame
E-7 -for
Rod
Dual
Beacon
(Proposed)
Feedlines
Sector
6'Obstruction
Mount
and Linear 300
295
280
260
200
100
0
Appurtenances
APPURTENANCES
SR 3/4
SR 3/4
210.0 ft
SR 1
N.A.
0.7
T5
200.0 ft
LC
IT=
180.0 ft
N.A.
N.A.
0.7
T7
SR 3/4
0.7
T8
SYMBOL LIST
SR 5/8
=2
SR 1
N.A.
76
0.7
T9
'2-
23 MATERIAL STRENGTH
SR 5/8
SR 5/8
SR 5/8
/32
"
120.0 ft IT= GRADE Fy Fu GRADE Fy Fu
10
% A572-50 50 ksi 65 ksi A36 36 ksi 58 ksi
N.A.
T10
0.6
N.A.
2. Tower designed for a 70 mph basic wind in accordance with the TIA/EIA-222-F Standard.
3. Tower is also designed for a 61 mph basic wind with 0.50 in ice.
4. Deflections are based upon a 50 mph wind.
T11
0.6
70.0 ft
SR 1
N.A.
7/16
T12
0.7
EHS
LC=
SR 5/8
248
'4-1
SR 1 5/8
60.0 ft /16"
IT=1
0%
T13
0.6
SR 5/8
40.0 ft
N.A.
N.A.
N.A.
T14
0.6
20.0 ft
B 4 @ 3.20833
T15
0.4
N.A.
34 K
6.7 ft
N.A.
N.A.
N.A.
T16
10.6 0.6
A
0.0 ft
54
1K K
42 K
Guy Low-Diagonals
R=240'
Top Guy Pull-Offs
Guy Hi-Diagonals
112 K (Axial)
Diagonal Grade
# Panels @ (ft)
Face Width (ft)
Bottom Girts
Horizontals
Weight (K)
Leg Grade
Diagonals
Top Girts
Mid Girts
Section
Legs
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Guyed Tower (HDA Project No. 04G-9999)
Project: Henderson,
22 Chestnut Street Henderson County, KY --- Existing Tower With Proposed Additional Antennas
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-1
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-GT-R2.eri
TIA/EIA-222-F - 70 mph/61 mph 0.5000 in Ice
Leg Capacity Leg Compression (K)
100 50 <- Minimum 0 Maximum -> -50 -100
300' 300'
290' 290'
280' 280'
260' 260'
250' 250'
240' 240'
220' 220'
210' 210'
200' 200'
180' 180'
Elevation (ft)
160' 160'
140' 140'
120' 120'
100' 100'
80' 80'
70' 70'
60' 60'
40' 40'
20' 20'
6'8-1/32" 6'8-1/32"
0' 0'
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Guyed Tower (HDA Project No. 04G-9999)
Project: Henderson,
22 Chestnut Street Henderson County, KY --- Existing Tower With Proposed Additional Antennas
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-3
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-GT-R2.eri
TIA/EIA-222-F - 70 mph/61 mph 0.5000 in Ice Maximum Values
Vx Vz Mx Mz
290' 290'
280' 280'
260' 260'
250' 250'
240' 240'
220' 220'
210' 210'
200' 200'
180' 180'
Elevation (ft)
160' 160'
140' 140'
120' 120'
100' 100'
80' 80'
70' 70'
60' 60'
40' 40'
20' 20'
6'8-1/32" 6'8-1/32"
0' 0'
0 5 10 0 50 100
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Guyed Tower (HDA Project No. 04G-9999)
Project: Henderson,
22 Chestnut Street Henderson County, KY --- Existing Tower With Proposed Additional Antennas
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-4
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-GT-R2.eri
TIA/EIA-222-F - Service - 50 mph Maximum Values
290' 290'
280' 280'
260' 260'
250' 250'
240' 240'
220' 220'
210' 210'
200' 200'
180' 180'
Elevation (ft)
160' 160'
140' 140'
120' 120'
100' 100'
80' 80'
70' 70'
60' 60'
40' 40'
20' 20'
6'8-1/32" 6'8-1/32"
0' 0'
0 5 10 0 0.5 0 0.5
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Guyed Tower (HDA Project No. 04G-9999)
Project: Henderson,
22 Chestnut Street Henderson County, KY --- Existing Tower With Proposed Additional Antennas
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-5
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-GT-R2.eri
Guy Tensions and Tower Reactions
TIA/EIA-222-F - 70 mph/61 mph 0.5000 in Ice
Maximum Values
Anchor 'A'@240 ft Azimuth 0 deg Elev 0 ft
300.0 ft Plane through centroid of tower
290.0 ft 290'
5/8
280.0 ft
EH
S,
SF
=
2.3
0,
260.0 ft
Tm
ax
=
250.0 ft 250'
18
.47
1/2
K,
EH
240.0 ft
Lc
S,
=
SF
37
=
5'3
2.2
-15
4,
/16
Tm
220.0 ft
", L
ax
=
u=
12
210.0 ft 210' 37
.02
4'1
K,
1/2
1-1
Lc
EH
200.0 ft
3/1
=
S,
34
6",
SF
5'4
Ls
=2
-9/
=
32
.33
37
", L
,Tm
6'2
u=
180.0 ft
ax
-7/
34
=
32
11
5'1
"
.55
7/3
K,
2",
Lc
Ls
=
=
31
160.0 ft
34
7'7
6'2
-1/
-5/
4",
32
Lu
"
=
31
7'3
6E
/32
HS
",
,
Ls
SF
=
= 2.6
31
0,
8'3
120.0 ft Tm
-13
ax
/16
= 7.9
"
9K
,L
c=
27
100.0 ft 6'2
-23
/32
", L
u=
27
5'1
1-2
80.0 ft 9/3
2", 2K
Ls
70.0 ft 70' = 27
7/16 6'9
EHS -3/
, SF 32
60.0 ft = 3. "
28,
Tm 42 K
ax =
6.33
K, L
c = 24
8'4- PLAN
1/16
40.0 ft ", Lu
= 24
8'1-
21/3
2", L
s = 24
8'7-
15/1
54
20.0 ft 6"
K
6.7 ft
0.0 ft 40 deg 34 K
1K R=240'
112 K (Axial)
42 K
ELEVATION
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Guyed Tower (HDA Project No. 04G-9999)
Project: Henderson,
22 Chestnut Street Henderson County, KY --- Existing Tower With Proposed Additional Antennas
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-6
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-GT-R2.eri
Feedline Distribution Chart
6'8-1/32" - 300'
Round Flat App In Face App Out Face Truss Leg
300'
Face A Face B Face C 300'
290' 290'
250' 250'
240' 240'
220' 220'
210' 210'
180' 180'
Elevation (ft)
(12) 1 5/8
140' 140'
(12) 1 5/8
(2) EW63 (to Proposed Antennas)
120' 120'
100' 100'
80' 80'
70' 70'
60' 60'
40' 40'
20' 20'
10' 10'
6'8-1/32" 6'8-1/32"
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Guyed Tower (HDA Project No. 04G-9999)
Project: Henderson,
22 Chestnut Street Henderson County, KY --- Existing Tower With Proposed Additional Antennas
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-7
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-GT-R2.eri
Feedline Plan
(12) 1 5/8
Feedline Ladder
B
A
(12) 1 5/8
(2) EW63 (to Proposed Antennas)
Feedline Ladder
C
er
dd
La
uit
nd
e
lin
Co
ed
gid
Fe
5/8
Ri
1
2"
2)
(1
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Guyed Tower (HDA Project No. 04G-9999)
Project: Henderson,
22 Chestnut Street Henderson County, KY --- Existing Tower With Proposed Additional Antennas
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-7
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-GT-R2.eri
Stress Distribution Chart
0' - 300'
> 100% 90%-100% 75%-90% 50%-75% < 50% Overstress
300'
Face A Face B Face C 300'
290' 290'
280' 280'
260' 260'
250' 250'
240' 240'
220' 220'
210' 210'
200' 200'
180' 180'
Elevation (ft)
160' 160'
140' 140'
120' 120'
100' 100'
80' 80'
70' 70'
60' 60'
40' 40'
20' 20'
6'8-1/32" 6'8-1/32"
0' 0'
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Guyed Tower (HDA Project No. 04G-9999)
Project: Henderson,
22 Chestnut Street Henderson County, KY --- Existing Tower With Proposed Additional Antennas
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-8
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-GT-R2.eri
Job Page
ERITower Structural Analysis Report -- 300' Guyed Tower (HDA Project 1 of 34
No. 04G-9999)
Project Date
Hodge Design Associates, P.C.
22 Chestnut Street Henderson, Henderson County, KY --- Existing Tower With 12:43:27 07/23/04
Proposed Additional Antennas
Evansville, Indiana 47713-1022 Client Designed by
Phone: 812.422.2558 ABC Towers and Tower Maintenance Gray Hodge
FAX: 812.422.3337
The main tower is a 3x guyed tower with an overall height of 300' above the ground line.
The base of the tower is set at an elevation of 0' above the ground line.
The face width of the tower is 3' at the top and tapered at the base.
This tower is designed using the TIA/EIA-222-F standard.
The following design criteria apply:
Tower is located in Henderson County, Kentucky.
Basic wind speed of 70 mph.
Nominal ice thickness of 0.5000 in.
Ice density of 56 pcf.
A wind speed of 61 mph is used in combination with ice.
Temperature drop of 75 °F.
Deflections calculated using a wind speed of 50 mph.
See Sheet E-7 for Feedlines and Linear Appurtenances..
See Sheet E-8 for Code Check/Stress Distribution..
Pressures are calculated at each section.
Safety factor used in guy design is 2.
Stress ratio used in tower member design is 1.333.
Local bending stresses due to climbing loads, feedline supports, and appurtenance mounts are not considered.
Options
Consider Moments - Legs Distribute Leg Loads As Uniform v Treat Feedline Bundles As Cylinder
Consider Moments - Horizontals Assume Legs Pinned Use ASCE 10 X-Brace Ly Rules
Consider Moments - Diagonals v Assume Rigid Index Plate v Calculate Redundant Bracing Forces
Use Moment Magnification v Use Clear Spans For Wind Area v Ignore Redundant Members in FEA
v Use Code Stress Ratios v Use Clear Spans For KL/r v SR Leg Bolts Resist Compression
v Use Code Safety Factors - Guys v Retension Guys To Initial Tension v All Leg Panels Have Same Allowable
Escalate Ice Bypass Mast Stability Checks Offset Girt At Foundation
Always Use Max Kz v Use Azimuth Dish Coefficients v Consider Feedline Torque
Use Special Wind Profile v Project Wind Area of Appurt. v Include Angle Block Shear Check
v Include Bolts In Member Capacity Autocalc Torque Arm Areas Poles
v Leg Bolts Are At Top Of Section v SR Members Have Cut Ends v Include Shear-Torsion Interaction
v Secondary Horizontal Braces Leg v Sort Capacity Reports By Component Always Use Sub-Critical Flow
Use Diamond Inner Bracing (4 Sided) v Triangulate Diamond Inner Bracing Use Top Mounted Sockets
Add IBC .6D+W Combination
Job Page
ERITower Structural Analysis Report -- 300' Guyed Tower (HDA Project 2 of 34
No. 04G-9999)
Project Date
Hodge Design Associates, P.C.
22 Chestnut Street Henderson, Henderson County, KY --- Existing Tower With 12:43:27 07/23/04
Proposed Additional Antennas
Evansville, Indiana 47713-1022 Client Designed by
Phone: 812.422.2558 ABC Towers and Tower Maintenance Gray Hodge
FAX: 812.422.3337
Wind 180
Guy A
Leg A
Wind 90
Fa
A
ce
ce
B
Fa
X
Leg C Z Leg B
Gu
yC Face C yB
Gu
Wind 0
Tower No. Mid Girt Mid Girt Mid Girt Horizontal Horizontal Horizontal
Elevation of Type Size Grade Type Size Grade
Mid
ft Girts
(36 ksi) (36 ksi)
T4 240'-220' 1 Solid Round 5/8 A36 Solid Round 5/8 A36
(36 ksi) (36 ksi)
T5 220'-200' 1 Solid Round 5/8 A36 Solid Round 5/8 A36
(36 ksi) (36 ksi)
T6 200'-180' 1 Solid Round 5/8 A36 Solid Round 5/8 A36
(36 ksi) (36 ksi)
T7 180'-160' 1 Solid Round 5/8 A36 Solid Round 5/8 A36
(36 ksi) (36 ksi)
T8 160'-140' 1 Solid Round 5/8 A36 Solid Round 5/8 A36
(36 ksi) (36 ksi)
T9 140'-120' 1 Solid Round 5/8 A36 Solid Round 5/8 A36
(36 ksi) (36 ksi)
T10 120'-100' 1 Solid Round 5/8 A36 Solid Round 5/8 A36
(36 ksi) (36 ksi)
T11 100'-80' 1 Solid Round 5/8 A36 Solid Round 5/8 A36
(36 ksi) (36 ksi)
T12 80'-60' 1 Solid Round 5/8 A36 Solid Round 5/8 A36
(36 ksi) (36 ksi)
T13 60'-40' 1 Solid Round 5/8 A36 Solid Round 5/8 A36
(36 ksi) (36 ksi)
T14 40'-20' 1 Solid Round 5/8 A36 Solid Round 5/8 A36
(36 ksi) (36 ksi)
T15 20'-6'8-1/32'' None Solid Round A36 Solid Round 5/8 A36
(36 ksi) (36 ksi)
T16 6'8-1/32''-0' None Solid Round A36 Channel C12x20.7 A36
(36 ksi) (36 ksi)
Tower Gusset Gusset Gusset Grade Adjust. Factor Adjust. Weight Mult. Double Angle Double Angle
Elevation Area Thickness Af Factor Stitch Bolt Stitch Bolt
(per face) Ar Spacing Spacing
Diagonals Horizontals
ft ft2 in in in
T11 100'-80' 0.00 0.0000 A36 1.01 1.05 1.01 36.0000 36.0000
(36 ksi)
T12 80'-60' 0.00 0.0000 A36 1.01 1.05 1.01 36.0000 36.0000
(36 ksi)
T13 60'-40' 0.00 0.0000 A36 1.01 1.05 1.01 36.0000 36.0000
(36 ksi)
T14 40'-20' 0.00 0.0000 A36 1.01 1.05 1.01 36.0000 36.0000
(36 ksi)
T15 20'-6'8- 0.00 0.0000 A36 1.01 1.05 1.01 36.0000 36.0000
1/32'' (36 ksi)
T16 6'8-1/32''- 0.00 0.0000 A36 1.01 1.05 1.01 36.0000 36.0000
0' (36 ksi)
Guy Data
Guy Guy Guy Initial % Guy Guy Lu Anchor Anchor Anchor End
Elevation Grade Size Tension Modulus Weight Radius Azimuth Elevation Fitting
Adj. Efficiency
ft K ksi plf ft ft ° ft %
290 EHS A 5/8 4.24 10% 21000 0.813 375'3/8'' 240' 0.0000 0' 100%
B 5/8 4.24 10% 21000 0.813 375'3/8'' 240' 0.0000 0' 100%
C 5/8 4.24 10% 21000 0.813 375'3/8'' 240' 0.0000 0' 100%
250 EHS A 1/2 2.69 10% 21000 0.517 345'31/32'' 240' 0.0000 0' 100%
B 1/2 2.69 10% 21000 0.517 345'31/32'' 240' 0.0000 0' 100%
C 1/2 2.69 10% 21000 0.517 345'31/32'' 240' 0.0000 0' 100%
210 EHS A 1/2 2.69 10% 21000 0.517 317'4-3/16'' 240' 0.0000 0' 100%
B 1/2 2.69 10% 21000 0.517 317'4-3/16'' 240' 0.0000 0' 100%
C 1/2 2.69 10% 21000 0.517 317'4-3/16'' 240' 0.0000 0' 100%
139.75 EHS A 7/16 2.08 10% 21000 0.399 276'1/8'' 240' 0.0000 0' 100%
B 7/16 2.08 10% 21000 0.399 276'1/8'' 240' 0.0000 0' 100%
C 7/16 2.08 10% 21000 0.399 276'1/8'' 240' 0.0000 0' 100%
70 EHS A 7/16 2.08 10% 21000 0.399 248'1-11/16'' 240' 0.0000 0' 100%
B 7/16 2.08 10% 21000 0.399 248'1-11/16'' 240' 0.0000 0' 100%
C 7/16 2.08 10% 21000 0.399 248'1-11/16'' 240' 0.0000 0' 100%
Guy Data(cont’d)
Job Page
ERITower Structural Analysis Report -- 300' Guyed Tower (HDA Project 8 of 34
No. 04G-9999)
Project Date
Hodge Design Associates, P.C.
22 Chestnut Street Henderson, Henderson County, KY --- Existing Tower With 12:43:27 07/23/04
Proposed Additional Antennas
Evansville, Indiana 47713-1022 Client Designed by
Phone: 812.422.2558 ABC Towers and Tower Maintenance Gray Hodge
FAX: 812.422.3337
Guy Pressures
Guy Guy z qz qz Ice
Elevation Location Ice Thickness
ft ft psf psf in
290 A 145' 19 14 0.5000
B 145' 19 14 0.5000
C 145' 19 14 0.5000
250 A 125' 18 14 0.5000
B 125' 18 14 0.5000
C 125' 18 14 0.5000
210 A 105' 17 13 0.5000
B 105' 17 13 0.5000
C 105' 17 13 0.5000
139.75 A 69'10-9/16'' 16 12 0.5000
B 69'10-9/16'' 16 12 0.5000
C 69'10-9/16'' 16 12 0.5000
70 A 35' 13 10 0.5000
B 35' 13 10 0.5000
C 35' 13 10 0.5000
Description Face Allow Component Placement Face Lateral # # Clear Width or Perimeter Weight
or Shield Type Offset Offset Per Spacing Diameter
Leg ft in (Frac FW) Row in in in klf
Feedline A Yes Ar (CfAe) 10' - 10' 1.0000 0.25 1 1 1.5000 0.0000 0.01
Ladder
Feedline B Yes Ar (CfAe) 10' - 10' 1.0000 0.25 1 1 1.5000 0.0000 0.01
Ladder
Feedline C Yes Ar (CfAe) 10' - 10' 1.0000 0.25 1 1 1.5000 0.0000 0.01
Ladder
2'' Rigid C Yes Ar (CfAe) 300' - 10' 1.0000 -0.25 1 1 2.0000 2.0000 0.00
Conduit
1 5/8 A Yes Ar (CfAe) 300' - 10' 1.0000 0.25 12 6 0.3750 1.9800 0.00
1 5/8 B Yes Ar (CfAe) 280' - 10' 1.0000 0.25 12 6 0.3750 1.9800 0.00
1 5/8 C Yes Ar (CfAe) 260' - 10' 1.0000 0.25 12 6 0.3750 1.9800 0.00
EW63 A Yes Af (CfAe) 200' - 10' 1.0000 -0.25 2 1 1.5742 1.5742 5.0668 0.00
(to Proposed
Antennas)
Dishes
Job Page
ERITower Structural Analysis Report -- 300' Guyed Tower (HDA Project 15 of 34
No. 04G-9999)
Project Date
Hodge Design Associates, P.C.
22 Chestnut Street Henderson, Henderson County, KY --- Existing Tower With 12:43:27 07/23/04
Proposed Additional Antennas
Evansville, Indiana 47713-1022 Client Designed by
Phone: 812.422.2558 ABC Towers and Tower Maintenance Gray Hodge
FAX: 812.422.3337
Description Face Dish Offset Offsets: Azimuth 3 dB Elevation Outside Aperture Weight
or Type Type Horz Adjustment Beam Diameter Area
Leg Lateral Width
Vert
ft ° ° ft ft ft2 K
UHX8-59 A Paraboloid From 1.00 0.0000 200' 8.00 No Ice 50.26 0.25
(Proposed) w/Shroud (HP) Leg 0' 1/2'' Ice 51.29 0.51
0'
UHX8-59 C Paraboloid From 1.00 0.0000 200' 8.00 No Ice 50.26 0.25
(Proposed) w/Shroud (HP) Face 0' 1/2'' Ice 51.29 0.51
0'
Load Combinations
Comb. Description
No.
1 Dead Only
2 Dead+Wind 0 deg - No Ice+Guy
3 Dead+Wind 30 deg - No Ice+Guy
4 Dead+Wind 60 deg - No Ice+Guy
5 Dead+Wind 90 deg - No Ice+Guy
6 Dead+Wind 120 deg - No Ice+Guy
7 Dead+Wind 150 deg - No Ice+Guy
8 Dead+Wind 180 deg - No Ice+Guy
9 Dead+Wind 210 deg - No Ice+Guy
10 Dead+Wind 240 deg - No Ice+Guy
11 Dead+Wind 270 deg - No Ice+Guy
12 Dead+Wind 300 deg - No Ice+Guy
13 Dead+Wind 330 deg - No Ice+Guy
14 Dead+Ice+Temp+Guy
15 Dead+Wind 0 deg+Ice+Temp+Guy
16 Dead+Wind 30 deg+Ice+Temp+Guy
17 Dead+Wind 60 deg+Ice+Temp+Guy
18 Dead+Wind 90 deg+Ice+Temp+Guy
19 Dead+Wind 120 deg+Ice+Temp+Guy
20 Dead+Wind 150 deg+Ice+Temp+Guy
21 Dead+Wind 180 deg+Ice+Temp+Guy
22 Dead+Wind 210 deg+Ice+Temp+Guy
23 Dead+Wind 240 deg+Ice+Temp+Guy
24 Dead+Wind 270 deg+Ice+Temp+Guy
25 Dead+Wind 300 deg+Ice+Temp+Guy
26 Dead+Wind 330 deg+Ice+Temp+Guy
27 Dead+Wind 0 deg - Service+Guy
28 Dead+Wind 30 deg - Service+Guy
29 Dead+Wind 60 deg - Service+Guy
30 Dead+Wind 90 deg - Service+Guy
31 Dead+Wind 120 deg - Service+Guy
32 Dead+Wind 150 deg - Service+Guy
33 Dead+Wind 180 deg - Service+Guy
34 Dead+Wind 210 deg - Service+Guy
35 Dead+Wind 240 deg - Service+Guy
36 Dead+Wind 270 deg - Service+Guy
37 Dead+Wind 300 deg - Service+Guy
38 Dead+Wind 330 deg - Service+Guy
Maximum Reactions
Job Page
ERITower Structural Analysis Report -- 300' Guyed Tower (HDA Project 16 of 34
No. 04G-9999)
Project Date
Hodge Design Associates, P.C.
22 Chestnut Street Henderson, Henderson County, KY --- Existing Tower With 12:43:27 07/23/04
Proposed Additional Antennas
Evansville, Indiana 47713-1022 Client Designed by
Phone: 812.422.2558 ABC Towers and Tower Maintenance Gray Hodge
FAX: 812.422.3337
Solution Summary
Sum of Applied Forces Sum of Reactions
Load PX PY PZ PX PY PZ % Error
Comb. K K K K K K
1 0.00 -30.64 0.00 -0.00 30.64 0.00 0.002%
2 0.00 -30.82 -31.51 0.00 30.82 31.50 0.019%
3 14.78 -30.64 -27.27 -14.78 30.64 27.26 0.019%
4 25.63 -30.46 -16.17 -25.63 30.46 16.17 0.000%
5 30.05 -30.64 0.00 -30.04 30.64 0.00 0.016%
6 25.95 -30.82 16.35 -25.94 30.82 -16.35 0.017%
7 14.78 -30.64 27.27 -14.77 30.64 -27.27 0.005%
8 0.00 -30.46 31.14 0.00 30.46 -31.14 0.000%
9 -14.78 -30.64 27.27 14.78 30.64 -27.27 0.004%
10 -25.95 -30.82 16.35 25.94 30.82 -16.35 0.017%
11 -30.05 -30.64 0.00 30.04 30.64 0.00 0.016%
12 -25.63 -30.46 -16.17 25.63 30.46 16.17 0.001%
13 -14.78 -30.64 -27.27 14.78 30.64 27.26 0.019%
14 0.00 -54.50 0.00 -0.00 54.50 0.00 0.001%
15 0.00 -54.90 -34.43 0.00 54.90 34.43 0.011%
16 15.83 -54.50 -28.70 -15.83 54.50 28.69 0.010%
17 27.09 -54.10 -16.69 -27.09 54.10 16.68 0.004%
18 32.03 -54.50 0.00 -32.03 54.50 0.00 0.008%
19 28.79 -54.90 17.67 -28.79 54.90 -17.67 0.010%
20 15.83 -54.50 28.70 -15.83 54.50 -28.69 0.001%
21 0.00 -54.10 32.46 -0.00 54.10 -32.46 0.000%
22 -15.83 -54.50 28.70 15.83 54.50 -28.69 0.001%
23 -28.79 -54.90 17.67 28.79 54.90 -17.67 0.010%
24 -32.03 -54.50 0.00 32.03 54.50 0.00 0.008%
25 -27.09 -54.10 -16.69 27.09 54.10 16.68 0.005%
26 -15.83 -54.50 -28.70 15.83 54.50 28.69 0.010%
27 0.00 -30.73 -16.08 0.00 30.73 16.08 0.004%
28 7.54 -30.64 -13.91 -7.54 30.64 13.91 0.004%
29 13.08 -30.55 -8.25 -13.08 30.55 8.25 0.007%
30 15.33 -30.64 0.00 -15.33 30.64 0.00 0.007%
31 13.24 -30.73 8.34 -13.24 30.73 -8.34 0.006%
32 7.54 -30.64 13.91 -7.54 30.64 -13.91 0.006%
33 0.00 -30.55 15.89 0.00 30.55 -15.89 0.001%
34 -7.54 -30.64 13.91 7.54 30.64 -13.91 0.006%
35 -13.24 -30.73 8.34 13.24 30.73 -8.34 0.006%
36 -15.33 -30.64 0.00 15.33 30.64 0.00 0.007%
37 -13.08 -30.55 -8.25 13.08 30.55 8.25 0.007%
38 -7.54 -30.64 -13.91 7.54 30.64 13.91 0.004%
Compression Checks
T1 300 - 280 1 1/2 20' 3'3'' 104.0 1.00 13.767 1.7672 -22.36 24.33 0.919
K=1.00
T2 280 - 260 1 1/2 20' 3'3'' 104.0 1.00 13.767 1.7672 -24.30 24.33 0.999
K=1.00
T3 260 - 240 1 1/2 20' 3'3'' 104.0 1.00 13.767 1.7672 -25.01 24.33 1.028
K=1.00
T4 240 - 220 1 3/4 20' 3'3'' 89.1 1.00 17.122 2.4053 -34.71 41.18 0.843
K=1.00
Job Page
ERITower Structural Analysis Report -- 300' Guyed Tower (HDA Project 22 of 34
No. 04G-9999)
Project Date
Hodge Design Associates, P.C.
22 Chestnut Street Henderson, Henderson County, KY --- Existing Tower With 12:43:27 07/23/04
Proposed Additional Antennas
Evansville, Indiana 47713-1022 Client Designed by
Phone: 812.422.2558 ABC Towers and Tower Maintenance Gray Hodge
FAX: 812.422.3337
T5 220 - 200 1 3/4 20' 3'3'' 89.1 1.00 17.122 2.4053 -40.10 41.18 0.974
K=1.00
T6 200 - 180 1 3/4 20' 3'3'' 89.1 1.00 17.122 2.4053 -31.67 41.18 0.769
K=1.00
T7 180 - 160 1 3/4 20' 3'3'' 89.1 1.00 17.122 2.4053 -31.32 41.18 0.760
K=1.00
T8 160 - 140 1 3/4 20' 3'3'' 89.1 1.00 17.122 2.4053 -44.22 41.18 1.074
K=1.00
T9 140 - 120 1 3/4 20' 3'3'' 89.1 1.00 17.122 2.4053 -44.22 41.18 1.074
K=1.00
T10 120 - 100 1 5/8 20' 3'3'' 96.0 1.00 15.618 2.0739 -34.79 32.39 1.074
K=1.00
T11 100 - 80 1 5/8 20' 3'3'' 96.0 1.00 15.618 2.0739 -36.90 32.39 1.139
K=1.00
T12 80 - 60 1 5/8 20' 3'3'' 96.0 1.00 15.618 2.0739 -40.69 32.39 1.256
K=1.00
T13 60 - 40 1 5/8 20' 3'3'' 96.0 1.00 15.618 2.0739 -40.36 32.39 1.246
K=1.00
T14 40 - 20 1 5/8 20' 3'3'' 96.0 1.00 15.618 2.0739 -42.00 32.39 1.297
K=1.00
T15 20 - 6.66667 1 5/8 13'3- 3'2- 94.8 1.00 15.894 2.0739 -41.05 32.96 1.245
31/32'' 17/32'' K=1.00
T16 6.66667 - 0 1 5/8 6'10- 1'7- 49.0 0.94 22.952 2.0739 -30.30 47.60 0.637*
11/16'' 29/32'' K=1.00
*
DL controls
T9 140 - 120 5/8 4'5-1/32'' 2'1-3/16'' 121.2 10.111 0.3068 -1.91 3.10 0.616
K=0.75
T10 120 - 100 5/8 4'5-1/32'' 2'1-5/16'' 121.6 10.047 0.3068 -1.25 3.08 0.407*
K=0.75
T11 100 - 80 5/8 4'5-1/32'' 2'1-5/16'' 121.6 10.047 0.3068 -1.30 3.08 0.422*
K=0.75
T12 80 - 60 5/8 4'5-1/32'' 2'1-5/16'' 121.6 10.047 0.3068 -1.41 3.08 0.457*
K=0.75
T13 60 - 40 5/8 4'5-1/32'' 2'1-5/16'' 121.6 10.047 0.3068 -1.44 3.08 0.468*
K=0.75
T14 40 - 20 5/8 4'5-1/32'' 2'1-5/16'' 121.6 10.047 0.3068 -1.48 3.08 0.481*
K=0.75
T15 20 - 6.66667 5/8 4'4- 2'1-3/16'' 120.8 10.169 0.3068 -1.49 3.12 0.477*
11/16'' K=0.75
*
DL controls
*
DL controls
*
DL controls
Tension Checks
T2 280 - 260 1 1/2 20' 3'3'' 104.0 30.000 1.7672 4.82 53.01 0.091
T5 220 - 200 1 3/4 20' 3'3'' 89.1 30.000 2.4053 4.60 72.16 0.064
T2 280 - 260 3/4 4'5-1/32'' 2'1-7/16'' 135.6 21.600 0.4418 0.80 9.54 0.084
T3 260 - 240 3/4 4'5-1/32'' 2'1-7/16'' 135.6 21.600 0.4418 2.84 9.54 0.297
T4 240 - 220 5/8 4'5-1/32'' 2'1-3/16'' 161.6 21.600 0.3068 1.00 6.63 0.151
T5 220 - 200 5/8 4'5-1/32'' 2'1-3/16'' 161.6 21.600 0.3068 2.23 6.63 0.336
T6 200 - 180 5/8 4'5-1/32'' 2'1-3/16'' 161.6 21.600 0.3068 0.87 6.63 0.132
T7 180 - 160 5/8 4'5-1/32'' 2'1-3/16'' 161.6 21.600 0.3068 1.05 6.63 0.158
T8 160 - 140 5/8 4'5-1/32'' 2'1-3/16'' 161.6 21.600 0.3068 1.57 6.63 0.237
T9 140 - 120 5/8 4'5-1/32'' 2'1-3/16'' 161.6 21.600 0.3068 1.48 6.63 0.223
T10 120 - 100 5/8 4'5-1/32'' 2'1-5/16'' 162.2 21.600 0.3068 1.04 6.63 0.157
T11 100 - 80 5/8 4'5-1/32'' 2'1-5/16'' 162.2 21.600 0.3068 1.10 6.63 0.166
T12 80 - 60 5/8 4'5-1/32'' 2'1-5/16'' 162.2 21.600 0.3068 1.57 6.63 0.237
Job Page
ERITower Structural Analysis Report -- 300' Guyed Tower (HDA Project 27 of 34
No. 04G-9999)
Project Date
Hodge Design Associates, P.C.
22 Chestnut Street Henderson, Henderson County, KY --- Existing Tower With 12:43:27 07/23/04
Proposed Additional Antennas
Evansville, Indiana 47713-1022 Client Designed by
Phone: 812.422.2558 ABC Towers and Tower Maintenance Gray Hodge
FAX: 812.422.3337
T13 60 - 40 5/8 4'5-1/32'' 2'1-5/16'' 162.2 21.600 0.3068 1.34 6.63 0.203
T14 40 - 20 5/8 4'5-1/32'' 2'1-5/16'' 162.2 21.600 0.3068 0.99 6.63 0.149
T15 20 - 6.66667 5/8 4'4- 2'1-3/16'' 161.1 21.600 0.3068 0.40 6.63 0.060
11/16''
T5 220 - 200 3/4 4'5-1/32'' 2'1-3/16'' 134.7 21.600 0.4418 1.65 9.54 0.173
T9 140 - 120 3/4 4'5-1/32'' 2'1-3/16'' 134.7 21.600 0.4418 0.39 9.54 0.041
T12 80 - 60 3/4 4'5-1/32'' 2'1-5/16'' 135.1 21.600 0.4418 0.25 9.54 0.026
T3 260 - 240 3/4 4'5-1/32'' 2'1-7/16'' 135.6 21.600 0.4418 2.44 9.54 0.256
T5 220 - 200 3/4 4'5-1/32'' 2'1-3/16'' 134.7 21.600 0.4418 0.74 9.54 0.077
T8 160 - 140 3/4 4'5-1/32'' 2'1-3/16'' 134.7 21.600 0.4418 0.94 9.54 0.099
T12 80 - 60 3/4 4'5-1/32'' 2'1-5/16'' 135.1 21.600 0.4418 0.25 9.54 0.026
*
DL controls
*
DL controls
*
DL controls
*
DL controls
*
DL controls
*
DL controls
Program Version 3.0.0.16 - 7/10/2004 File:C:/Documents and Settings/ghodge.HODGEDESIGN.000/My Documents/ERITower Project Data Files/Sample
Reports/Sample-GT-R2.eri