1400 Opus Place
Downers Grove, IL 60515
T-Mobile Designation:
Site Name: USCC-Monmouth
Site Number: CH99223B
Project Description: 2022 MW ADD PROJECT
Site Address: 515 N. State Street, Floor 14, Chicago, IL 60654
Site Coordinates: 40.91130600°, -90.66200000°, Elevation 764’ AMSL
Structure Description: Monopole-Platform Mount
Mountain LTD Engineering has carried out a structural mount analysis of the above referenced
structure for the antenna and equipment noted. This analysis has been performed in
accordance with the ANSI/TIA-222-H Structural Standard for Antenna Supporting Structures
meeting the requirements of the 2018 International Building Code based on ASCE7-16.
EXECUTIVE SUMMARY
T-Mobile’s existing platform mount installed at elevation 174’ AGL on the subject site
Monopole tower is structurally adequate with a maximum rating of 100% when subjected to
the proposed project appurtenance loads.
Sincerely,
T-Mobiles’ existing appurtenances from the prior project (Anchor-phase 3) are installed
on a small low-profile platform mount. T-Mobile’s current project will add a small
microwave/radio to one side of the platform.
As per Ref [5] mapping, T-Mobile’s antenna radiation height & the tower height are at
140’ & 190’ AGL respectively. The platform’s triangular shaped deck consisting of (6) L4
beams and grating is supported on (3) 3.5” OD pipes at the perimeter and (3) 4” square
tube (HSS) arms attached to the tower via a universal ring mount. Three 2-7/8” OD
pipe horizontal rails 4’ above deck with (9) 2-3/8” OD vertical pipes form the 3 sides of
the mount. Refer to Appendix I for photos / sketches and Appendix II for mount analysis.
REFERENCES
Table 1-References
1. [1] 2022 MW Add Construction Drawings by “Mountain, LTD, Engineering, 06/17/2022.
2. [2] 2021 Anchor phase 3 RFDS by “TMO RF Engineering”, Version 2, dated 05/17/2021.
3. [3] 2022 MW Add Microwave path datasheet by “ ComSearch” RCN#220506J4, 05/06/2022.
4. [4] 2021 Anchor phase 3 Construction drawing site walk photos by “ Ramaker”, 08/20/2020.
5. [5] Antenna & Mount Mapping report by “High Tower Solutions”, dated 01/06/2021.
6. [6] 2021 Anchor phase 3 Mount analysis report by “Mission 1 Communications”, 02/08/2021.
7. [7] 2021 Anchor phase 3 Structural analysis report by “Mission 1 Communications”, 05/17/2021.
ANALYSIS CRITERIA
This analysis is completed using RISA-3D package to create & analyze a 3D non-linear
model of the existing mount using the following analysis criteria.
Page | 2
MATERIAL GRADE
Table 3-Materials
WF Shapes, Plates, & bars ASTM A36, Fy=36 KSI
Tubes including HSS shapes ASTM A500 Grade B, Fy=46 KSI
Connection Bolts ASTM A325 or ASTM A490
U-bolt material & temporary bolts ASTM-A307
Pipe mounts ASTM A500, Gr A, Fy=33.0 Ksi
APPURTENANCES
RESULTS
The results of the existing mount analysis subjected to the project appurtenance loads indicate
adequacy of the mount with a maximum capacity usage factor (rating) of 100% in a non-primary
member. A summary of analysis results for mount members is shown below.
CONCLUSIONS
T-Mobile’s proposed project will add a 2’ diameter Microwave dish on the existing platform
mount in sector Beta side. The present analysis results indicates adequacy of the platform
mount without a need for modifications.
Page | 3
Standard Conditions and Considerations
This analysis is based on the theoretical capacity of the members and is not a condition
assessment of the tower. The analysis is solely based on the information supplied. We
consider supplied information to us as reasonably accurate. Mountain LTD
Engineering, LLC has made no independent determination of data accuracy. The
followings are considered applicable to this structural analysis unless otherwise involved
parties of the project inform us to the contrary:
All prior structural modifications, if any, are considered to have been property
completed per the applicable construction documents and to be fully effective. This
tower has been analyzed according to the original design criteria or the minimum
design wind loads recommended by the Telecommunications Industry Association
Standard EIA/TIA-222-G. If the owner or local or state agencies require a higher
design wind load, Mountain, LTD Engineering, LLC should be made aware of this
requirement. The antenna configuration is as supplied and/or stated in the analysis
section and considered to be complete & accurate. All antennas, mounts, coaxial
cables, and waveguides are considered to be properly installed and supported as
per the manufacturer’s requirements.
Antenna and mount sizes and their projected areas used in the analysis are based
on the best interpretation of the supplied data, knowledge of antenna type, and
industry practice. Miscellaneous items such as minor Uni-struts, mounts, & supports
have not been structurally analyzed, designed, or detailed as a part of our work. We
recommend contractor to purchase and provide material of adequate size and
strength from a reputable tower manufacturer. The existing foundation is considered
to be in good condition with no structural defects affecting member capacities.
Page | 4
APPENDIX I-Photos & Sketches
Page | 5
7 through 14 – TMO’s Existing Mount -Ref [4]
Page | 6
PROPOSED APPURTENANCE LAYOUT-Ref [1] & [2]
SK-1
Page | 7
ASCE 7 Hazards Report
Address: Standard: ASCE/SEI 7-22 Elevation: 688.23 ft (NAVD 88)
1303 Clyde Dr Risk Category: III Latitude: 41.747661
Naperville, Illinois
60565
Soil Class: Default Longitude: -88.135492
Wind
Results:
Data Source: ASCE/SEI 7-22, Fig. 26.5-1C and Figs. CC.2-1–CC.2-4, and Section 26.5.2
Date Accessed: Thu Jun 16 2022
Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear
interpolation between contours. Wind speeds are interpolated in accordance with the 7-22 Standard. Wind speeds
correspond to approximately a 3% probability of exceedance in 50 years (annual exceedance probability =
0.000588, MRI = 1,700 years). Values for 10-year MRI, 25-year MRI, 50-year MRI and 100-year MRI are Service
Level wind speeds, all other wind speeds are Ultimate wind speeds.
PGA M : 0.091 TL : 12
S MS : 0.21 SS : 0.17
S M1 : 0.16 S1 : 0.074
S DS : 0.14 S DC :
S D1 : 0.1 V S30 : 260
Snow
Results:
2
Ground Snow Load, pg : 63 lb/ft
Allowable Stress Design Ground Snow Load: 44.1 lb/ft^2
20-year MRI Value: 15.29 lb/ft^2
Winter Wind Parameter: 55
Elevation: 688.2 ft
Data Source: ASCE/SEI 7-22, Figures 7.6-1 and 7.6-2 A-D
Date Accessed: Thu Jun 16 2022
ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent
professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such
professionals in interpreting and applying the contents of this Tool or the ASCE 7 standard.
In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors,
employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential
damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by
law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data
provided by the ASCE 7 Hazard Tool.
Page | 8
Y
Z X
Mountain Ltd SK - 4
RN Platform with HR June 23, 2022 at 5:12 PM
CH99223B-Anchor Platform on MP. (a).062322.r3d
X
Y Z
Mountain Ltd SK - 5
RN Platform with HR June 23, 2022 at 5:13 PM
CH99223B-Anchor Platform on MP. (a).062322.r3d
Y
Z X
N144
N133
N131 N137
N132
N121 PIPE_2.0
.5x
N148 N72
N122 L2
5x2
N152
PIPE_2.0
N146 .5x
N33 N143 N141 2 .5x N82
L2.
5x2PIPE_2.0
3 N71
N80
N37 N139 N151
N153A
3
N94
N26 N150N31
N147 N16 N99
3.0
PIPE_2.0
N69
E_
N84
L2.
N17 4X
PIPE_2.0
N57
6
N18 L N151B 4 X
4X
4X
N19 S N97
N134 HS N157 L N56
4X N65
L4X PIPE_2.0
HSS4X N29N20 4X
N159
N135 4X 4
N49 N77
6
6
4X
PIPE_2.0
N11 N153
N43
6
N1
3.0
N54
PIPE_2.0
N48
E_
N64
HS
N40 X 6
N9A P L4X 4 N59
IP
S4
N8AE_3 L 4 X 4 X6
X4
. N155
N38 N2 0 N42 N60
X4
N13
N45 N36 N3 N47 4 X 6 N85
L4X N61 N66
N4 L4X 4X 6 N154
N14N5
N62
N34 N89
N8 N96
N87
N35
Mountain Ltd SK - 3
RN Platform with HR June 23, 2022 at 5:10 PM
CH99223B-Anchor Platform on MP. (a).062322.r3d
Code Check
Y ( Env )
No Calc
> 1.0
.90-1.0
Z X .75-.90
.50-.75
0.-.50
.31
.7 7
.91
.82
.7 6
.82
1.0 .90
0 NC
.31
.76
.24 .5 0
.2 3
.4 9 .89
.92 .4 4
.78
.80
.44
.37
.6 3
.62 .4 9
.72
.46
.99
.48
.24
.75
.43
.2 4
.60
.49
.45
.44
Mountain Ltd SK - 2
RN Platform with HR June 23, 2022 at 5:06 PM
CH99223B-Anchor Platform on MP. (a).062322.r3d
Company : Mountain Ltd June 23, 2022
Designer : RN 5:08 PM
Job Number : CH99223B-Anchor Checked By:_____
Model Name : Platform with HR