REINFORCED CONCRETE ASSIGNMENT No.

5
DESIGN
1. A 400 mm concrete wall supports a 5. A square footing 2.75m on side is to
dead load D=205kN/m and a live load carry a central load of 675kN DL and
of 146kN/m. The allowable bearing 900kN LL through a 0.40m square
pressure is qa=216kPa and the level at column. fc’=27.6MPa, fy=414MPa.Use
the bottom footing, which is 1.20m strength design method.
below grade the wall footing has an
effective depth of 225mm and total 6. A square footing 2.6m x 2.6m is
depth of 300mm. fc’=21.73MPa, supporting a column 560mm x 560mm
fy=276.5MPa. Assume concrete with a service dead load of 1780kN.
weights 23,5kN/m3 and that of soil is The footing is 0.5m deep with an
15.7kN/m3. Design the footing. effective depth of 0.4m. fc’ =17.24kPa.

2. Design a wall footing to support a 7. A column 450mm x 450mm square


300mm reinforced concrete wall with width fc’=27.65MPa reinforced with 8-
DL=292kN/m, LL=200kN/m. The 25mm bars of fy=345.58MPa supports
bottom of the footing is 1.2m below a dead load of 1003kN and a live load
the final grade, the soil weights 780kN. The allowable bearing pressure
15,700N/m3. The allowable soil is 240kPa. The base of the footing is
pressure is 190 kPa, fy=276.5MPa, 1.5m below the grade fc’=27.56MPa,
fc’=27.5MPa. fy=345.59MPa. Assume weight of soil
and concrete to have an average unit
3. Design a plain concrete footing for a wt of 19.7kN/m3.
300mm reinforced concrete wall that
supports a dead load of 176kN/m 8. A square spread footing supports
including the weight of wall and an 450mm square column supporting a
88kN/m live load. The base footing is service dead load of 1784kN and a
to be 1.5m below the final grade. service live load of 1204kN. The
fc’=20.7kPa and allowable soil column is built of fc’=34.6MPa and has
pressure is 190kPa, weight of soil a 8-28mm diameter with fy=414.7MPa.
15.7kN/m3. Design a spread footing to be
constructed using fc’=20.7MPa,
4. Design a spread footing for a column fy=414.7MPa. The top of the footing
480mm x 480mm in section to carry a will be covered with 150mm of fill with
dead load of 900kN and a live load of a density of 18880N/m3 and a 150mm
1000kN. Allowable soil pressure at of concrete basement floor. The
service load is 170kPa. Neglect the allowable bearing pressure of soil is
weight of soil above the footing. Use 288kPa.
fc’=20MPa, fy=400MPa.
9. Design the square footing having a
column dimension of 600mm x

CENG 115 Page 1


REINFORCED CONCRETE ASSIGNMENT No. 5
DESIGN
600mm and carries an axial load of
1340kN (dead load) and 720kN (live 13. Design a square footing to support a
load). Allowable soil pressure is 260 350mm x 350mm column carrying a
kPa. There is 0.6m earth overburden dead load of 320kN, live load of
having a unit weight of 15.7kN/m3, 560kN, a dead load moment of 12kN-m
fc’=20.7MPa, fy=276.5MPa. and a live load moment of 18kN-m.
Allowable soil pressure = 200kPa, fc’ =
10. Design a reinforced concrete footing 350MPa. Use ACI 318-83.
to support a 450mm square tied
column carrying a dead load = 800kN 14. From the wall footing. Determine the
and a live load = 800kN. The width of total shear at the critical section:
footing is limited to 2.0m. Allowable fc’=28MPa.
soil pressure = 250kPa, fc’ for column =
28MPa, fc’ for footing = 20MPa, fy for Use weight of concrete = 24kN/m3
all steel = 276MPa and longitudinal Unit weight of soil = 16kN/m3
steel column consists of 25mm Allowable soil pressure – 200kPa
diameter bars. Use F.S. of 1.5 form moment

11. A 400mm thick bearing wall of rigid 15. Design a spread footing to carry a PDL-
frame building carries a vertical load of =420kN, PLL=535kN and a MDL=228kN-
300kN dead load and 300kN live load m, MLL=250kN-m plus horizontal thrust
per linear meter, together with a of HDL=42kN, HLL=53kN acting at the
moment of 90kN-m dead load and top of the footing. The column has a
90kN-m live load per linear meter of dimension of 500mm x 500mm,
length. Design the footing to support fy=400MPa, fc’=28MPa. For footing:
the bearing wall for a uniform soil fc’=21MPa, fy=400MPa. Allowable soil
pressure. Allowable soil pressure = pressure is 150kPa. Assume a uniform
300kPa. Use fy=280MPa, fc’ = 20MPa. soil pressure acting at the bottom of
Use ACI 318-83 code. the footing.

12. A 550mm square column carries a 16. Design a spread footing to support a
concentric dead load and live load, 350mm x 350mm column carrying a
420kN and 540kN, respectively, aside dead load of 300kN and a live load of
from clockwise moment of 230kN-m 500kN. The footing is subjected to a
due to dead load and 250kN-m due to bi-axial moment produced by the
live load for this column design a effect of dead load, live load and
square footing that such two soil earthquake load. The unfactored
pressure will be uniform. Allowable moments are tabulated below.
soil pressure = 150kPa, fy=415MPa. Use
ACI 318-83 code. MDX=50kN-m MDY=30kN-m

CENG 115 Page 2


REINFORCED CONCRETE ASSIGNMENT No. 5
DESIGN
MLX=60kN-m MLY=50kN-m the extreme face of the
MEX=36kN-m MEY=29kN-m column in order to have a
Allowable soil bearing capacity is uniform distribution of
192MPa, fc’=21MPa, fy=414MPa. pressure.
c. Determine the dimension
17. Design a footing supported by piles to of the footing.
carry a DL of 625kN and a LL of 800kN.
The column is 450mm x 450mm. 20. Design a combined footing to support
Allowable load of 270kN/pile and a an exterior column carrying a dead
working load of 180kN/pile. load of 935kN and a live load of 625kN,
fc’=20.7MPa, fy=276MPa. an interior column carrying a dead
load of 1070kN and a live load of
18. Design a combined footing to support 715kN. The exterior column is 400mm
the exterior column having a x 400mm while the interior column is
dimension of 400mm x 560mm with a 450mm x 450mm. Distance center to
dead load of 930kN and a live load of center of columns is 5.50m. The
620kN and the interior column having footing cannot extend more than
a diameter of 500mm carrying a dead 400mm from the center of the
load of 1070kN and a live load of exterior column. Allowable soil
710kN. The center of the exterior pressure = 240kPa, fc’=20MPa,
column should not exceed 380mm fy=276MPa. Use 318-83.
from the edge of the property line.
The two columns are spaced 5.48m, 21. Design a combined footing for a given
center to center. Allowable soil set of loads tabulated below.
pressure = 240kPa, fc’=20.7MPa, Allowable soil pressure is 96kPa.
fy=276.5MPa. Use ACI 318-83. Assume the location of the footing to
be 1.8m below the grade, weight of
19. The base of the footing is 1.8m below soil is 15.7kN/m3, fc’=20.7MPa,
the ground surface. It has a surcharge fy=414.7MPa.
of 4.8kPa on the ground surface. The
thickness of the footing is 1.2m. Exterior column Interior column
Allowable bearing pressure of the soil 300mm x 300mm 375mm x
is 280kPa. Weight of concrete 375mm
2.4kN/m3 and soil is 18kN/m3. DL=268kN DL=490kN
LL=266kN LL=490kN
a. Determine the effective MDL=27kN-m MDL=40.5kN-m
bearing pressure of the MLL=27kN-m MLL=40.5kN-m
soil Spacing of column = 4.6m
b. Determine the distance of Center to property line of exterior
the resultant force from column = 0.15m

CENG 115 Page 3


REINFORCED CONCRETE ASSIGNMENT No. 5
DESIGN
24kN/m3 and soil is 18kN/m3. Design
22. Design a combined footing for a the footing.
300mm exterior wall whose outside
face is on a property line, 6m from the
center of a 500mm x 500mm interior
column. the load on the wall is 300kN
dead load and 600kN live load and the
load on the column is 400kN dead load
and 600kN live load. Allowable soil
pressure is 250kPa, fc’=28MPa, and
fy=414MPa. Use ACI 318-83 code.

23. Design a trapezoidal footing to


support two 500mm x 500mm column
5.50m apart. Column 1 carries a dead
load of 1200kN and a live load of
800kN. Column 2 carries a dead load
of 900kN and a live load of 660kN.
Allowable soil pressure = 190kPa,
fc’=21MPa, fy=415MPa.

24. The base of the footing is 1.8m below


the ground surface. It has a surcharge
of 4.8kPa on the ground surface. The
thickness of the footing is 1.2m.
Allowable bearing pressure of the soil
is 280kPa. Weight of concrete is

CENG 115 Page 4