SEATWORK # 1
COPY AND ANSWER. SHOW YOUR COMPLETE SOLUTION AND BOX YOUR FINAL ANSWER.
A combined footing carries an exterior column 300mm by 450mm at the property line which is
subjected to a total service load P1=890kn and P2=1,557kn. The live load is 35% of the total load. The
bearing capacity of the soil at the level of the footing base is 192kpa and the average value of the soil and
footing unit weight is 18.85kn/m3. A surcharge of 4.8kpa results from the slab on the grade fc’=20.7mpa
fy=415mpa. Base at the footing is at 2.13m below the grade. Assume thickness of footing to be 875mm.
Normal weight of concrete and use 75mm as steel covering.
1. Determine the dimension of the rectangular combined footing and check for shear strength.
2. Determine the longitudinal reinforcement.
3. Determine the transverse reinforcement.
PAMANTASAN NG LUNGSOD NG VALENZUELA
COLLEGE OF ENGINEERING AND INFORMATION TECHNOLOGY
CIVIL ENGINEERING DEPARTMENT
QUIZ # 2
COPY AND ANSWER. SHOW YOUR COMPLETE SOLUTION AND BOX YOUR FINAL ANSWER.
1. A 300mm square column is supported by a 2.2m by .90m rectangular footing. Fc’= 27.60mpa
Fy= 414.7mpa. Effective depth of footing is 300mm. Allowable soil pressure is 240kpa.Use 2001
NSCP.
PD = 220 KN MD = 10 KN-M
PL = 137 KN ML = 16 KN-M
ME = 8 KN-M
2. The base of the footing is 1.8 m below the ground surface. It has a surcharge of 4.8 kpa on the
ground surface. The thickness of the footing is 1.2m. The allowable bearing pressure of the soil
is 280kpa. Weight of concrete is 24kN/m3 and soil is 18Kn/m3.