Professional Documents
Culture Documents
400
+8.350 +8.350 +8.350
1. This drawing is to be read in conjunction with sheet NO. 1 /3 and 2 /3 of
1761 drawing no. 3/2019
12 mm dia two legged 2. All dimensions are in millimetres and levels in meters.
+6.589 400 +6.589 +6.589 stirrups @ 150 mm c/c 3. For general notes, please refer sheet no: 1/3.
4. No dimensions shall be scaled off. Only written dimensions are to be followed.
6. High yield strength corrosion resistant deformed bars conforming to
2500 I.S 1786 - 1985 grade Fe 415 shall be used for reinforcement for all
12 mm dia two legged 12 mm dia two legged structural members. Cover for all reinforcement is as per IRC specifications.
stirrups @ 150 mm c/c stirrups @150 mm c/c Sufficient anchorage length and lap length should be provided as per
V V I.S 456-2000.
Q Q
7. Mix used
3 bars curtailed at 2.5 m from top Abutment, Abutment cap - RCC M 30
1000 1200 3800 25 mm dia 150mm c/c Max. aggregate size - 20 mm
25 mm dia 150mm c/c
+1.300 +1.300 +1.300 8. Bending, tying and placing in position of reinforcement
should be as per standards.
1500 12mm dia 150 mm 16 mm dia 150mm c/c 12mm dia 150 mm 16 mm dia 150mm c/c 9. Elastomeric Bearing of size 710 x 220 x 61 mm shall be provided.
all round all round
-0.200 -0.200 -0.200 10. All specifications should be in accordance with the latest editions of IRC
12 mm dia 150mm c/c 25 mm dia 150mm c/c 12 mm dia 150mm c/c 25 mm dia 150mm c/c sections I, II, III, VII and relevant I.S codes.
11. Filling behind abutments should be as per appendix- VI of IRC 78-1983.
22 Nos 32 mm dia Proper drainage facilities (weep holes along with filter material) should be
22 Nos 32 mm dia provided to prevent any accumulation of water in the back fill.
H H
12. Suitable protection works should be provided as per site condition.
13. Bank connections if needed may suitably be provided.
14. Bored cast in situ piles 1000mm dia is provided for foundation.Piles should
15 2350 2350 15 15 2350 2350 15 150 2350 2350 150
500
rest on hard rock with proper embedment.
500 500 500 500 500
6000 6000 6000 shall be provided along the length of piles.
15. All specifications for piles should be strictly in accordance with IS 2911-1979
DETAILS OF COUNTERFORT REINFORCEMENT DETAILS OF COUNTERFORT REINFORCEMENT DETAILS OF END COUNTERFORT part 1 section II.
16. All reinforcement from piles and abutment should be taken into pile cap and
anchored properly.
17. The pile should project 75mm into the pile cap.
18. The load bearing capacity of piles as well as bearing strata should be ensured
Rectangular counterfort before execution by conducting initial pile load test as per IS 2911-1979( part IV).
400 19. Suitable water stops should be provided at the expansion joint proposed
6000 +8.350
1000 1200 3800
between abutment, pier and lockwall for water tightness.
12 mm bars @ 20. A levelling concrete of 100 mm thick in 1:4:8 shall be provided below all pile
two layers of mesh 250mm c/c
650 500
reinforcement 8 mm dia caps after stabilising the soil.
12 mm dia two legged @100 mm c/c in both directions 1761 21. Maximum horizontal load on single pile in counterfort abutment - 35 Tonnes
stirrups @ 150 mm c/c directly under the bearing at Maximum Vertical load on single pile - 180 Tonnes
2250
20 mm and 100 mm from the
3400
top respectively
+6.589
500
+6.189
400 1200
2250 3 bars curtailed at 2.5 m from top
in the form of stirrups
2250
12 mm dia two legged
stirrups @ 150 mm c/c
12 mm dia 150mm c/c
500 22 Nos 32 mm dia
3400
2250
12 mm dia two legged
stirrups @ 150 mm c/c 1000
650 500
SECTION H-H
2350 2350 6000
400 200
2000 8150 1000 8150 2300
300
300
900
800 1050 800 1050 800 1700 1700
800 800 800
4300 4400
3000
TRUE COPY
800 1050 800 1050 800
200 500
650
2450 4200 4200 4200 4200 4200 1250
FILE No.
750 KARINGALIMUKKU IN KOZHIKODE DIST.
PILE ARRANGEMENT OF LOCK SHUTTER PIER DETAILS OF ABUTMENT
(INSIDE RIVER) sd/- sd/- sd/-
PILE ARRANGEMENT OF LOCK SHUTTER PIER DSGN CHD RECM
(BANK SIDE) ASSISTANT DIRECTOR DEPUTY DIRECTOR DIRECTOR
REF. No.
ARUNDAS .D sd/- sd/-
DRN REWD APPD
D'Man JOINT DIRECTOR CHIEF ENGINEER
THIRUVANANTHAPURAM DRG NO : 3/2019
DATE : 22.12.2018 SHEET No : 3/3
NOTES
2000 2000 2000 1. This drawing is to be read in conjunction with sheet No.1/3 and 3/3 of
+6.589 +6.589 drawing no. 3/2019.
Canal bund road (+2.500) 1200 1200 1200
+2.500 Canal bund road (+2.500) 2. All dimensions are in millimetres and levels in meters.
P 1200 1200 3. No dimensions shall be scaled off. Only written dimensions are to be
2000 2000 followed.
20 mm dia 150mm c/c 20 mm dia 200mm c/c 20 mm dia 150mm c/c 20 mm dia 150mm c/c 4. All specifications should be stricly in accordance with the latest editions of
relevant IS and IRC codes.
5.The execution of lock shutter portion should only be done after receiving the
10 mm dia clips @ 300mm c/c 10 mm dia clips @ 300mm c/c 10 mm dia clips @ 300mm c/c mechanical drawings for shutter.Groove size provided for the pier is tentative.
The actual size should be fixed in cosultation with the mechanical wing of
20 mm dia 150mm c/c 20 mm dia 150mm c/c Irrigation department before the construction and if any major changes needed
Surface reinforcement of should be informed to this office.
10 mm dia @ 200mm c/c 6. High yield strength corrosion resistant deformed bars conforming to I.S 1786 -
on both ways D D D D 1985 grade Fe 415 shall be used for reinforcement for all structural members.
2300 900 1550 1550 900 2300 V V
Cover for all reinforcement should be as per IRC specifications.Sufficient
V V
-3.650 -3.650 -3.650
20 mm dia 120mm c/c anchorage length and lap length should be provided as per I.S 456-2000.
20 mm dia 120mm c/c 1800 1000 1500 1800 at top and bottom
at top and bottom 7. Concrete Mix to be used for the structure
in both ways Lock Pier - RCC - M30
in both ways -5.150
-5.450 20 mm dia 150mm c/c -5.450 Lock wall - RCC - M30
12mm dia 150 mm 12mm dia 150 mm at top and bottom 12mm dia 150 mm
all round all round 150 all round Pile cap - RCC - M30
150 150 in both ways 150 150 1150 1500 Piles - RCC - M3 5
A A 21 nos 20 mm dia B B A A
V V 30 nos 32 mm dia V V 30 nos 32 mm dia V V
Lock shutter pier - CC M 20
12 mm dia 180mm c/c
12 mm dia 150 mm c/c 12 mm dia 150 mm c/c 1150 -3.650 900 -3.650 8. Bending, tying and placing in position of reinforcement should be as per
1000 2000 1000 standards.
750 2900 750 4300 750 2900 750
1500 1800 9. All the embeded parts required for fixing the gate should be fixed simultaneously
4400 LOCK WALL 4400 -5.150 with the concreting of pier.
SECTION X-X at top and bottom -5.450
12mm dia 150 mm c/c in both ways
all round 20 mm dia @ 150 mm c/c Piles should rest on hard rock with proper embedment. Stiffner rings of
1000 mm dia pile 12mm dia 150 mm c/c at top and bottom
E E all round in both ways 11. All specifications for piles should be strictly in accordance with IS 2911- 1979
1200 mm dia pile V V
F F V V part 1 section II.
12. All reinforcement rods from piles, pier, lock wall should be taken into pile cap and
anchored properly.
13. The pile should project 75mm into the pile cap.
20 mm dia 120mm c/c 1000 650 3000 650 14. The load bearing capacity of piles as well as bearing strata and depth of piles
5000 20 mm dia 150mm c/c 750 2900 750 should be ensured before execution by conducting initial pile load test as per IS
4250 SECTION - BB
DETAILS OF LOCK PIER (INSIDE RIVER) 4400 2911-1985( part IV).
20 mm dia 120mm c/c DETAILS OF LOCK PIER (BANK SIDE) 15. Static evaluation of capacity of piles is only arbitrary and hence the pile load test
20 mm dia 150mm c/c
650 mentioned above are to be strictly conducted and reported to this office.
750 16. Suitable bed protection may be done if necessary during execution to avoid
both ways excessive erosion of bed material.
200 2000 17. A levelling concrete of 100mm thick in 1:4:8 shall be provided below all pile caps
20 mm dia 150mm c/c after stabilizing the soil.
3000 20 mm dia 150mm c/c 18. Maximum horizontal load on single pile (1200mm dia) - 60 Tonnes
4250 300
3000 Maximum Vertical load on single pile (1200mm dia) - 280 Tonnes
5000 Maximum horizontal load on single pile (1000mm dia) - 26 Tonnes
400 400
7300 Maximum Vertical load on single pile (1000mm dia) - 185 Tonnes
20 mm dia 150mm c/c 7500
1200
20 mm dia 200mm c/c
20mm and other at 100 mm from top shall be provided directly under the bearing.
SECTION - AA 3000 20 mm dia 150mm c/c
3000 20 mm dia 150mm c/c
2900
4400 1200
3000
REINFORCEMENT DETAILS OF PILE CAP 4300 DETAILS AT - P 650 3000
LOCK WALL (BANK SIDE) REINFORCEMENT DETAILS OF PILE CAP 650 650 750 2900
4300 750 750
FOR LOCK WALL (INSIDE RIVER) 4400
PLAN OF PILE CAP(LOCK PIER)
(INSIDE RIVER) PLAN OF PILE CAP(LOCK PIER)
(BANK SIDE)
Canal bund road (+2.500) 2200 800 14000 800 2200 800 14000 800 2200
+2.500 Canal bund road (+2.500)
12 mm @ 8L-stirrups 7500
G
V
FILE No.
SECTION - GG
KARINGALIMUKKU IN KOZHIKODE DIST.
DETAILS OF LOCK WALL , BRIDGE PIER & SHUTTER PIER
LOCK PIER CAP DETAILS
sd/- sd/- sd/-
1000
2900 DSGN CHD RECM
SECTION - CC ASSISTANT DIRECTOR DEPUTY DIRECTOR DIRECTOR
4400
REF. No.
3000 ARUNDAS .D sd/- sd/-
REINFORCEMENT DETAILS OF PILE CAP 4300 APPD
DRN REWD
LOCK SHUTTER PIER (BANK SIDE) D'Man JOINT DIRECTOR CHIEF ENGINEER
REINFORCEMENT DETAILS OF PILE CAP
FOR LOCK SHUTTER PIER (INSIDE RIVER) FILE NO: THIRUVANANTHAPURAM DRG NO : 3/2019
DAMS -AD 8 /1/2017/IDRB DATE : 22.12.2018 SHEET No : 2/3
C/L of Canal
+8.350(road level)
NOTES
2000 2000 2000
2000
35000
Sheet pile
8000
9. Suitable bed protection may be done during the execution to avoid excessive erosion of bed material
-11.550
8000
-3.650
if necessary.
sheet pile 10. Groove size provided In the lock wall and lock shutter pier is tentative and can be fixed in
1150 1250
consultation with the Mechanical wing of the Irrigation Dept.Fixing of embedded parts of shutter shall
+2.500
also be done in consultation with mechanical wing.
1000
4200 4200
11. The cutoff wall should suitably be extended into the banks on both sides upto atleast twice their
depth from top of floor (Clause 17.1 of IS 6966- 1988).
12. A lock chamber of 14 m width,a lock pier of size 2x2 m, two shutter piers and 2 abutments are
30 cm dia sluice
provided.
-3.650
minimum thickness of 8.5mm.
LOCK WALL
4250 25. Deck slabs adopted is from standard plans for Highway Bridge Vol.3 MOST
(Drawing No:BD/1-76,BD/2-76 A,BD/3-76 A for16.50 m effective span.
26. The top soil for a depth of 2m below the apron may be removed and filled with sand and the soil
+8.350(road level)
LOCK WALL
5000
4250
below the apron should be stabilized so as to attain a SBC of 6 t/m2.
27. The gabion boxes of size 1mx1mx1m shall be made of mechanically woven double twisted wire
mesh of PVC coated galvanized steel of dia 2.70mm /3.7mm(ID/OD) as per IS 16014-2012.Each
+6.589
3500
2450
box shall be tied upto form a mat
SECTION - ZZ
28. The gabion boxes shall be filled before placing in the required location and the stones shall be larger
3000 3000 than the mesh openings and of more or less uniform size. The basket shall be full and not bulging.
11050
2000 2000 2000
2000 70000 2000 2000 Inverted filter should be provided below the gabion blocks as per IS 6966.
LOCK
PIER 3000
LOCK
PIER
LOCK
PIER 3000 29. 30 cm dia sluice fitted with valve should be provided inside the lock walls for maintaining the water
level inside the lock.
2450 30.Two holes of 1m dia 30cm deep may be provided for each shutter portion in the apron for dewatering.
1000
3500
31. Before taking up the project the technical feasibility and financial viability shall be examined in detail
by the Chief Engineer,I & A, Tvpm.
LOCK WALL
4250
5000
4250
1200
2000
5000
LOCK WALL
LOCK WALL
5000
4250
3500
2450
TRUE COPY
4200 4200
4200 4200
IRRIGATION DEPARTMENT, KERALA
IRRIGATION DESIGN AND RESEARCH BOARD
1000
-3.650 -3.650
4200 4200
CONSTRUCTION OF LOCK CUM BRIDGE ACROSS
+2.500
FILE No.
1150 1250
3000
3000
Sheet pile
GENERAL DRAWING
2000
-8.550
REF. No.
Z ARUNDAS .D sd/- sd/-
DRN REWD APPD
D'Man JOINT DIRECTOR CHIEF ENGINEER
PLAN THIRUVANANTHAPURAM DRG NO : 3/2019
DATE : 22.12.2018 SHEET No : 1/3