LTJ-CVL-007-CA-05
CALCULATION SHEET OF WARESHOUSE
Revision : A Status : IFR
The wind loads are calculated based on SNI 1727:2013 and ASCE 7-10 with the basic wind speed
of 120 km/h or 33 m/sec. Wind load are applied on buildings and other structures considering height
up to 18 m based on Envelope Procedure. A minimum wind pressure of 0.77 kN/m2 is to be applied
as per ASCE 7-10 cp. 27.4.7.
Pada dinding,
q p
Wind Direction G Cpnet
N/m 2
N/m2
Arah angin datang 490 0.85 0.98 408.02
Contract No : CSPBD - 19001 Document No :
LTJ-CVL-007-CA-05
CALCULATION SHEET OF WARESHOUSE
Revision : A Status : IFR