to find a break in a phase conductor, trace the wire until the

WARNING signal stops,


Do not attempt to repair this unit. It to find a break in a neutral conductor, connect a load between
contains no user-serviceable the phase and neutral. Trace the wire until the signal stops.
parts.
NON-CONTACT AC VOLTAGE Do not expose the unit to ex- 5 Operating of voltage detector
tremes in temperature or high hu-
DETECTOR WITH FLASHLIGHT VT-2 midity (see specifications). Test the unit on known functioning circuit or component:
Failure to observe these precautions If the unit does not function as expected on a known func-
can result in injury and can damage tioning circuit, replace the batteries.
the instrument. If the unit still does not function as expected, send the unit to
repair.
Place the probe tip on or near the circuit or unit to be tested.
INSTRUCTION MANUAL LED and audible beeper indicate the presence of AC Voltage
2 Features from 90…1000V (50/60Hz).
WARNING Non-contact detection of AC Voltage 90…1000V (50/60Hz).
Read and understand all of the in- Rugged, double molded case. Note:
structions and safety information in May be used to find a break in a wire or detect the presence of The voltage detector cannot detect voltage on armored cable
this manual before operating or ser- voltage at outlets, lighting fixtures, circuit breakers, wires and or on cable in conduit, behind panels or in metallic enclosures.
vicing this tool. cables. The detector can react to extremely low frequency electrostatic
Bright LED and audible beeper indicator if voltage is present. field, such as electrified materials.
Built-in bright flashlight with ON/OFF button. The detector can show the presence of voltage at a greater di-
1 Safety Convenient size with pocket clip. stance from the object, in the case of high concentration of live
An essential tool for every electrician and tradesperson. objects in the near to measured object (eg. circuits box).
This instruction manual and any markings on the tool provide in-
formation for avoiding hazards and unsafe practices related to the 3 Detector description 6 Battery replacement
use of this tool. Observe all of the safety information provided.
The VT-2 voltage detector is intended to check for the presence 1. Disconnect the unit from the circuit.
WARNING of AC voltage, signaling the user with an LED on. Built-in bright 2. Fold back the clip (4) and remove detector handle (2) by moving it
Read and understand this material flashlight with ON/OFF button and audible beeper indicator. to the right side (according to the picture).
before operating or servicing this 3. Replace the batteries (wrong polarity of batteries may damage de-
6 5 4 3 2 1
equipment. Failure to understand how tector).
to safely operate this tool can result in 4. Put the battery compartment cover.
an accident causing serious injury or
death. 7 Specifications
a) Indicators: LED and audible beeper
WARNING b) Voltage range: 90…1000V AC (50/60Hz)
Electric shock hazard - contact with c) Overvoltage category: Cat III 1000V
live circuits can result in severe injury ① Flashlight. d) Pollution Degree: 2
or death. ② Detector handle. e) Ingress protection: IP 54
③ Flashlight power ON/OFF. f) Operating temperature: : -5…+40 st. C
④ Detector clip. g) Humidity: 80% without condensation
WARNING Detector body.
⑤ h) Battery: 2 x 1,5V batteries (AAA, NEDA 24A or IEC LR 03)
Electric shock hazard: ① Detector cap. i) Dimensions: 177mm (length), Φ27mm (diameter)
Do not use the unit if it is wet or j) Weight: aprox. 100g (without batteries)
damaged. 4 Operation k) Flashlight: one white LED
Do not apply more than the rated
voltage between the probe tip and The Voltage Detector is useful for the identifying phase conduc-
earth ground. tors, finding a break in a wire and detecting the presence of AC volt-
Do not operate with the case age at:
Version 1.0 10.04.2012
open.
Failure to observe these warning can outlets,
result in severe injury or death. switches,
circuit breakers,
fuses,
wires and cables.

Note: The voltage detector can be used to find a break in a wire: