Professional Documents
Culture Documents
H4091 MM25 Sterilizer - Final
H4091 MM25 Sterilizer - Final
SAMKUN
CONTENTS
1. Preface
1-1.Purpose of the sterilizer
1-2.General Notice
1-3.Caution
3. Specification
3-1. Specification
3-2. Installation condition
4. Explanations of components
4-1. Standard parts
4-2. Option parts
5. Operating method
1) Preparation
2) Start
3) Operation
4) Stop
6. Installation
6-1. Instruction for installation and assembly
6-2. Moving Method & Condition (Weight, Dimension)
6-3. Warning in regard to inappropriate installation.
6-4. Safety measure to be followed for installation
7. Maintenance.
7-1. Safety Precaution
7-2. Periodic check and adjustment
7-3. Caution of replacement for parts
7-4. Instruction of replacement
7-5. Breakdown and how to check.
1. Preface
1-1. Purpose of the sterilizer
- The water, which is generated for drinking by fresh water generator in vessel or supplied water in
yard, has plenty of germs and bacteria in ship, therefore this water should be disinfected for drinking by
the appropriate method.
- General use below method:
→ U.V sterilizing type.
→ Chlorinator type
→ O3 sterilizing type
→ etc.
- Among those sterilizer units, U.V. sterilizing type is widely used. Because it is easy to control and
repair with simple structure.
- To remove typical viruses, colitis germs and bacteria, U.V. sterilizer is equipped with U.V. lamp that
emits efficiently a large amount of ultraviolet rays 253.7nm which have excellent germicidal effect.
- In order to obtain maximum benefit, the user should confirm that the unit is installed and operated
correctly. Thus, the user can avoid accidents and retain the manufacturer’s warranty.
- These operating instructions help the user to understand as dividing into separate sections for easy
reference.
- Please read carefully before installing and operating the sterilizer
- The sterilizer must be used for the designated purpose and in combination with any devices or
components recommended or approved by the manufacturer.
1-3. Caution.
- The sterilizer must only be inspected and repaired by qualified staff who are familiar with this unit
and possible dangers during inappropriateness operation or service.
- Any electrical work on the sterilizer must only be carried out by skilled staff-qualified electricians or
person under supervision of a qualified staff.
2-2. Address
128-56, MAE-RI, SANGDONG-MYOEN, GIMHAE,
GYEONGNAM, SOUTH KOREA
Tel : +82-55-338-3030, Fax : +82-55-332-7123
3. Specification
3-1.Specification
SPECIFICATION
Sterilizing Capacity 1000 L/H 3000 L/H 5000 L/H 10000 L/H
Germicidal Lamp 20W x 1PCS 39W x 1PCS 39W x 2PCS 39W x 4PCS
Water In / Out
JIS 5/10 K - 25A JIS 5/10K - 25/32A JIS 5/10K - 40A JIS 5/10K - 50A
Connection
Max Water Flowrate 1,200 L/H 3,500 L/H 6,000 L/H 11,000 L/H
Note : The manual of the product out of above mentioned capacity is same as this manual
3-2.Installation condition
1) Temperature
- The sterilizer should be installed between 2 degrees centigrade and 55 degrees centigrade(2℃
~55℃)
2) Humidity
- The sterilizer should be installed in dry place.
- It might be risk of electric leakage, shock and aging, if the product is installed in humid area.
3) Height
- It must be installed at the proper height so that user can operate easily.
- In order to replace filter and quartz sleeve of Sterilizer, the enough maintenance space must be
checked before installing.
4. Explanations of component
4-1. Standard parts
1) Inlet
- The tail of inlet is flange type, which is the first connector to supply portable water in the equipment.
The standard of this flange is based on JIS or KS, and bolt and nut must be tightened to prevent a leak
of water.
- Material is sus304.
2) Outlet
- The tail of outlet is flange type like inlet, which is connector to transport sterilized water from the
equipment to the suitable place. In addition, the standard of flange is based on JIS or KS, and bolt and
nut must be tightened to prevent a leak of water.
3) Filter housing
- This equipment has a filter inside and assembled in front of chamber.
4) Filter element
- This filter would remove refuse in water supplied to the product.
5) Filter cover
- Filter cover is the equipment to change it when you want to change filter, which was made clean
water in filter housing.
7) Chamber Body
The inside of chamber is the place where sterilization occurs in.
8) U.V. lamp
- U.V. lamps efficiently emit a large amount of ultraviolet ray 253.7nm(nanometers) which has
excellent germicidal effect.
- These lamps have similar structures and electrical characteristics to general fluorescent lamps used for
illumination but composed of ultraviolet ray glass which efficiently transmits ultraviolet rays at
253.7nm.
9) Quartz sleeve
- This is made of quartz that gets excellent transmissivity of ultraviolet rays.
2) Solenoid valve
- This valve blocks flowing water when abnormal alarm occurs.
- This valve is composed of valve body and coil(220V/110V).
5. Operating method
1) Preparation
- Install this unit on designated place in accordance with section 6 “ installation”
- Confirm all connection including inlet and outlet lines.
- Confirm the proper electric source and water is available.
- Open the water line.
- Check the water leakage
- Supply unit with operating voltage for 24 hours prior to start-up.
2) Start
- Turn on the selector switch after checking the water leakage for about 5 min.
3) Operation
- Check the Ampere meter indicates normal electric current.
- Confirm that it takes a few minute for U.V. lamp to become stable after power on.
- Check the U.V. monitor indicates over 80% after lamp becomes stable.(option part)
- And then check the running lamp on.
- After 15 min., Reset Hour meter.
- In case of abnormal condition, Check the hour meter and Ampere meter.
5) Stop
- Turn off the selector switch.
6. Installation
6-1. Instruction for installation and assembly
z The sterilizer should be installed in a dry room indoors
z Ample free space should be allowed for the maintenance of the device.
z The sterilizer should be installed on straight and even wall
z Special foundation for installation is not necessary.
z When installing the sterilizer, ensure all connections are even and no pressure is placed on
inlet and outlet connections.
z The sterilizer should be installed in safety place.
z The sterilizer should be installed in well-ventilated place.
z The sterilizer should be installed 2℃~55℃
z The water inlet and outlet lines should be equipped with shut off valves and a by-pass
system.
z The drain/plug is provided.
z Within the range of possibility, the outside connection pipe is more than a grade SUS 304.
z Flush the pipe before connecting.
z Connect Fresh water pipe to the sterilizer inlet and lines.
NOTE : PROTECT YOUR EYE AND SKIN AGAINST THE ULTRA VIOLET RAY.
7. Maintenance.
7-1. Safety Precaution
z To obtain maximum efficiency and operation of the sterilizer ensure all sections of the
manual read carefully.
z Don’t touch any electric equipment with wet hands.
z Protect your eye and skin against the ultra violet.
z Turn off the power and drain out all water before replacing the filter.
z Don’t pressure too much when assembling the gland fittings, since it’s very sensitive
part to be broken easily.
z Before the replacement, be sure to clean with soft dry cloth.
z U.V. sterilizer has very sensitive components like U.V. lamp and Quartz sleeve.
Therefore, please pay attention a lot when use it.
z Please turn off the running switch, if it wouldn’t be operating.
z Please drain out and close the inlet valve, if it wouldn’t be operating.
NOTE : TURN OFF THE POWER AND DRAIN OUT ALL WATER
① Dirtiness of filter
In fact, this has no direct relation to sterilization power, however, it is said that the bacteria and germ
are always stick in the filter and it will be replaced periodically at least every 3 month.
② Dirtiness of water tube
As a dirtiness of water tube may be caused decreasing sterilizing power it is always paying attention to
clean it once a three month both side, interior surface with condenser brush and exterior surface with
soft dry cloth.
③ The germicidal lamps get older
It is said that it's average life is generally for about 9,000 hours when all days used and in this case the
100% of sterilizing power will be decreased, even though it is very dangerous to see the light with your
naked eyes when the new replacement, and it is always covered with paper or use any kind of glasses.
④ Dirtiness of germicidal lamp surface
As to decrease the sterilizing effect, it is at least, to clean with soft dry cloth every six months and for
new replacement, should be clean before set-in.