You are on page 1of 12

Republic of the Philippines

DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS


AGUSAN DEL SUR 2ND
DISTRICT ENGINEERING OFFICE
REGIONAL OFFICE XIII
San Francisco, Agusan del Sur

Lab. Report No. 02-02-058-2022


O.R No. 1478269
Date. 2-Feb-2022

TEST REPORT ON CONCRETE AGGREGATES

Project : 21NC0096 (Re-ad) - Concreting of Mambaos-Pamangotan-Maputing Farm to Market Road


Location : Loreto, Agusan del Sur
(Name) (Number) (City/Province)
Kind of Material : Aggregate Subbase Course
Sample Identificatio : ASC-01
Quantity Represente : 2,500 cu.m
Sampled at : Jobsite
Original Source : Umayam Riverbed, Loreto, Agusan del Sur
Supplied by : DAVE Construction
Proposed Use : Subbase Course
Spec's Item No. : 200(1) (AASHTO T180/AASHTO T193)
Sampled by : MARIO S. DEL MONTE JR. - Contractor's Materials Engineer 25-Jan-2022
: (Name & Designation) (Date)

Submitted by : ANGEL BERT C. HIMO - Quality Assurance Engineer DPWH ADS 2ND DEO 26-Jan-2022
: (Name & Designation) (Office) (Date)

Contractor : DAVE Construction

TEST REQUIREMENTS RESULTS

Optimum Moisture Content, % 5.82%

California Bearing Ratio


CBR value at MDD, % 30.00 % min. 37.36%

REMARKS/RECOMMENDATION: Passed to its required specifications.


PREPARED BY: CHECKED BY:

EDNA D. CURATO LEODEGARIO M. MAZO


Laboratory Technician II Engineer III
Chief, Quality Assurance Section
ATTESTED BY:

BEN ALDEN R. SERNA


OIC -District Engineer
R.13/12.6/qas/edc.
fgfdg

R.13/12.6/qas/edc.
R.13/12.6/qas/edc.
Republic of the Philippines
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS
AGUSAN DEL SUR 2ND
DISTRICT ENGINEERING OFFICE
REGIONAL OFFICE XIII
San Francisco, Agusan del Sur

WORKSHEET FOR PROCTOR COMPACTION TEST

Project : 21NC0096 (Re-ad) - Concreting of Mambaos-Pamangotan-Maputing Farm to Market Road


Location : Loreto, Agusan del Sur
(Name) (Number) (Province)
Contractor : DAVE Construction
Kind of Material : Aggregate Subbase Course Spec's Item No. 200-1
Sampled at : Jobsite
(Give accurate location as possible)
Original Source : Umayam Riverbed, Loreto, Agusan del Sur
(Pit, Quarry, River, etc. location)
Sampled by : MARIO S. DEL MONTE JR. - Contractor's Materials Engineer 25-Jan-2022
(Name & Designation) (Date)
Tested by : Edna D. Curato - Laboratory Technician II DPWH ADS 2ND DEO 7-Feb-2022
(Name & Designation) (Office) (Date)
Computed by : Edna D. Curato - Laboratory Technician II DPWH ADS 2ND DEO 10-Feb-2022
(Name & Designation) (Office) (Date)
Laboratory No. : 02072022-089
TRIAL NO. 1 2 3 4 5
Water Added, ml 180 ml 180 ml 180 ml 180 ml
Mold + Wet Soil, kg 10.709 11.078 11.181 11.003
Mold, kg 6.180 6.180 6.180 6.180
Wet Soil, kg 4.529 4.898 5.001 4.823
Wet Density, kg/cu.m. 2,131 2,305 2,353 2,270
Container No. J-I X -I P-I A-I
Container + Wet Soil, g 110.44 110.26 110.42 110.35
Container +Dry Soil, g 105.93 105.41 104.88 102.98
Water, g 4.51 4.85 5.54 7.37
Container, g 15.00 15.00 15.00 15.00
Wt. of Dry Soil, g 90.93 90.41 89.88 87.98
Water Content, % 4.96% 5.36% 6.16% 8.38%
Dry Density, kg/cu.m. 2,031 2,188 2,217 2,094

Standard Proctor Compaction Curve Standard Proctor Test Method

COMPACTION TEST Mold Diameter, cm. : 15.2000


2,500 Mold Volume, cu.m. : 0.002125
2,300 Rammer, kg. : 4.54
2,100 MDD=2,309 kg/cu.m Height of Drop, mm. : 475.2
1,900
Dry Density, kg/cum.

No. of Layer : 5
1,700
No. of Blows : 56
1,500
1,300
1,100
OMC=5.82%
900
700
500 MDD = 2,309 kg/cu.m.
300 OMC = %
5.82%
100
4.50% 5.00% 5.50% 6.00% 6.50% 7.00% 7.50% 8.00% 8.50% 9.00%

Water Content (%)

WITNESSED BY: CERTIFIED CORRECT:

MARIO S. DEL MONTE JR. ANA MARIE S. VILLACERAN


Contractor's Materials Engineer Engineer II
Head, Materials Testing Unit
R.13/12.6/qas/edc.
kjkjkj

R.13/12.6/qas/edc.
2295
2249

4.96% 5.36% 5.82% 6.16% 8.38%


2,031 2,187.59 2,309.00 2,216.77 2,094.22

8.02
2297

2,309 4.5+F57:Q65
5.82%

500
30
15000

R.13/12.6/qas/edc.
Republic of the Philippines
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS
AGUSAN DEL SUR 2ND
DISTRICT ENGINEERING OFFICE
REGIONAL OFFICE XIII
San Francisco, Agusan del Sur

WORKSHEET FOR CBR TEST

Project : 21NC0096 (Re-ad) - Concreting of Mambaos-Pamangotan-Maputing Farm to Market Road


Location : Loreto, Agusan del Sur
(Name) (Number) (City/Province)
Kind of Material : Aggregate Subbase Course Spec's Item No. 200-1
Sampled at : Jobsite
(Give as accurate location as possible)
Original Source : Umayam Riverbed, Loreto, Agusan del Sur
(Pit, quarry, river, etc. and location)
Sampled by : MARIO S. DEL MONTE JR. - Contractor's Materials Engineer 25-Jan-2022
(Name & Designation) (Date)
Tested by : Edna D. Curato - Laboratory Technician II DPWH ADS 2ND DEO 11-Feb-2022
(Name & Designation) (Office) (Date)
Computed by : Edna D. Curato - Laboratory Technician II DPWH ADS 2ND DEO 18-Feb-2022
(Name & Designation) (Office) (Date)
Laboratory No : 02112022-090

SPECIMEN BEFORE SOAKING (65 BLOWS)


Moisture Content Dry Density
Container No. Y-I I-I Total wet weight 19.601
Total wet weight 111.30 112.05 Weight of mold 14.599
Total dry weight 106.00 106.72 Weight of wet soil 5.002
Wt. of Container 15.00 15.00 Moisture content 5.818
Wt. of water 5.30 5.33 Wet Unit weight of soil 2,354
Wt. of dry soil 91.00 91.72 Volume of mold 0.002125
Moisture Content 5.82 5.81 Dry Density 2,224.47
Average = 5.82

SPECIMEN AFTER SOAKING


Moisture Content
Container No. N-1 H-1 Wt. of water 7.57 7.60
Total wet weight 110.05 112.15 Wt. of dry soil 87.48 89.55
Total dry weight 102.48 104.55 Moisture Content 8.65 8.49
Wt. of Container 15.00 15.00 Average 8.57
CBR TEST
Penetration, (inch.) 0.0125 0.0250 0.0375 0.0500 0.0750 0.1000 0.2000
Dial Reading 0 1 3 7 15 24 30
Load, kg 22.22 22.22 66.67 155.56 345.41 539.69 674.62
Load, kg/sq.cm. 1.15 1.15 3.45 8.04 17.85 27.89 34.86
Standard Loads 70 105
CBR 39.84 33.20
Corrected CBR 37.36%
SWELL
Time/Date 12-Feb-2022 13-Feb-2022 14-Feb-2022 15-Feb-2022
Dial Reading 0.799 1.000 1.224 1.425
% Swell 17.43% 21.81% 26.71% 31.09%

WITNESSED BY: CERTIFIED CORRECT:

MARIO S. DEL MONTE JR. ANA MARIE S. VILLACERAN


Contractor's Materials Engineer Engineer II

R.13/12.6/qas/edc.
Head, Materials Testing Unit

R.13/12.6/qas/edc.
Project : 21NC0096 (Re-ad) - Concreting of Mambaos-Pamangotan-Maputing Farm to Market Road

Location : Loreto, Agusan del Sur

100

90

80

70

60

50

40
SOAKED CBR CORRECTED VALUE 37.36%

30

MDD = 2,309 kg/cu.m

20

10

0
1000 2000 3000 4000 5000 6000 7000

DRY DENSITY, kg/m3


61.99

2246
Republic of the Philippines
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS
AGUSAN DEL SUR 2ND
DISTRICT ENGINEERING OFFICE
REGIONAL OFFICE XIII
San Francisco, Agusan del Sur

WORKSHEET FOR SIEVE ANALYSIS

Project : 21NC0096 (Re-ad) - Concreting of Mambaos-Pamangotan-Maputing Farm to Market Road

Location : Loreto, Agusan del Sur


(Name) (Number) (City/Province)
Kind of Materials : Aggregate Subbase Course Spec's /Item No. 200-1
Sampled at : Jobsite
(Give accurate location as possible)
Original Source : Umayam Riverbed, Loreto, Agusan del Sur
(Pit,quarry,river,etc. and location)
Sampled by : MARIO S. DEL MONTE JR. - Contractor's Materials Engineer 25-Jan-2022
(Name & Designation) (Date)
Tested by : Edna D. Curato - Laboratory Technician- I DPWH ADS 2ND DEO 16-Mar-2020
(Name & Designation) (Office) (Date)
Computed by : Edna D. Curato - Laboratory Technician- I DPWH ADS 2ND DEO 23-Mar-2020
(Name & Designation) (Office) (Date)

Lab. No. : 03162020-398 Weight of samples in grams


Dry Unit wt,kg/cu.m Loose Original 5,010.00
Rodded Oven dry 4,721.00
Moisture Content 6.12 % Wash Oven dry 4,509.00
Fineness Modulus

Sieve Size Weight % COMMULATIVE SPEC'S


REMARKS
mm. inch. Retained Retained Wt. Passing % Passing % Retained % Passing
75.00 (3")
63.00 (2 1/2)
50.00 (2") 0 4,720 100 0 100 Passed
37.50 (1 1/2) 614 4,106 87 13
25.00 (1") 360 3,746 79 21 55 - 85 Passed
19.00 (3/4") 346 3,400 72 28
12.50 (1/2) 603 2,797 59 41
9.50 (3/8") 681 2,116 45 55 40 - 75 Passed
4.75 (No.4) 563 1,553 33 67
2.00 (No.10) 701 852 18 82
0.425 (No.40) 315 537 11 89
0.075 (No.200) 201 336.00 7 93 0 - 12 Passed
Pan 124
Washing Pan
212.00
N0. 0.075
Total 4,508.00 212

REMARKS/RECOMMENDATION: Passed to its required specifications.

WITNESSED BY: CERTIFIED CORRECT:

MARIO S. DEL MONTE JR. ANA MARIE S. VILLACERAN


Contractor's Materials Engineer Engineer II
R.13/12.6/qas/jologs
Head, Materials Testing Unit

HJKHJKHJ

R.13/12.6/qas/jologs