You are on page 1of 1

NATIONAL WATER AND SEWERAGE CORPORATION

CENTRAL LABORATORY - BUGOLOBI


P.O BOX 7053 KAMPALA Email: waterquality@nwsc.co.ug

Student: Richard Rupiny


Address: Kyambogo University
P.O. Box 1, Kyambogo
Date Sample Received: 11/01/2023
Water Quality assessment lab results
Standards
for
Test Parameter Units Borehole Borehole Mukura Mukura
Untreated
H/C III King of Stream I Stream II Potable
water
Kings S.S
Lab number 096/2023/C 097/2023/C 098/2023/C 099/2023/C
Bact: Faecal coliforms CFU/100mL 0 0 13 10 0
Iron: Total mg/l 0.390 1.553 2.056 0.317 0.300
Colour (True) TCU 32 1260 233 28 50
Electrical conductivity (EC) µS/cm 748 126.0 347 176.2 2500

Hardness: Total mg/l 130 41.2 35.6 42.4 600


pH ---- 7.06 6.49 5.71 6.05 5.5 – 9.5
Total suspended solids (TSS) mg/l 3 48 113 7 0

Turbidity NTU 0.57 31.2 25.0 1.56 25

Supervised by: Bayo Robert


Sign: ………………………….
Date:…………………………