You are on page 1of 1

CLIENT SMART 

COMMUNICATION INC.
SHEET 1
CALCS BY ENGR. SARZA
CHECKED BY ‐
DATE 14‐Sep‐20
SUBJECT GUY CABLE CHECK
SITE 447_ANTIPOLO PADILLA

LOADING CONDITION: EX
GUY  ACTUAL  INITIAL  ALLOWABLE  BREAKING  REQUIRED  ACTUAL  DEMAND 
DIAMETER  TENSION  TENSION TENSION LOAD FACTOR OF  FACTOR OF  OVER  REMARKS
∅ (mm) (kN) (kN) (kN) (kN) SAFETY SAFETY CAPACITY
1 9.5 20.851 6.052 30.258 60.516 2 2.902 0.689 OK!
2 9.5 13.430 6.052 30.258 60.516 2 4.506 0.444 OK!
3 9.5 10.853 6.052 30.258 60.516 2 5.576 0.359 OK!
4
5
6
7
8

LOADING CONDITION: EX+PR
GUY  ACTUAL  INITIAL  ALLOWABLE  BREAKING  REQUIRED  ACTUAL  DEMAND 
DIAMETER  TENSION  TENSION TENSION LOAD FACTOR OF  FACTOR OF  OVER  REMARKS
∅ (mm) (kN) (kN) (kN) (kN) SAFETY SAFETY CAPACITY
1 9.5 23.090 6.052 30.258 60.516 2 2.621 0.763 OK!
2 9.5 13.104 6.052 30.258 60.516 2 4.618 0.433 OK!
3 9.5 10.650 6.052 30.258 60.516 2 5.682 0.352 OK!
4
5
6
7
8

LOADING CONDITION: EX+PR+FU
GUY  ACTUAL  INITIAL  ALLOWABLE  BREAKING  REQUIRED  ACTUAL  DEMAND 
DIAMETER  TENSION  TENSION TENSION LOAD FACTOR OF  FACTOR OF  OVER  REMARKS
∅ (mm) (kN) (kN) (kN) (kN) SAFETY SAFETY CAPACITY
1 9.5 27.060 6.052 30.258 60.516 2 2.236 0.894 OK!
2 9.5 15.255 6.052 30.258 60.516 2 3.967 0.504 OK!
3 9.5 11.383 6.052 30.258 60.516 2 5.316 0.376 OK!
4
5
6
7
8

LOADING CONDITION: RETRO
GUY  ACTUAL  INITIAL  ALLOWABLE  BREAKING  REQUIRED  ACTUAL  DEMAND 
DIAMETER  TENSION  TENSION TENSION LOAD FACTOR OF  FACTOR OF  OVER  REMARKS
∅ (mm) (kN) (kN) (kN) (kN) SAFETY SAFETY CAPACITY
1 11.5 31.877 8.170 40.849 81.697 2 2.563 0.780 OK!
2 11.5 23.975 8.170 40.849 81.697 2 3.408 0.587 OK!
3 11.5 17.369 8.170 40.849 81.697 2 4.704 0.425 OK!
4 9.5 8.656 6.052 30.258 60.516 2 6.991 0.286 OK!
5
6
7
8

You might also like