You are on page 1of 1

13. WIRE ROPEc CALCULATIONS.

The wire rope calculation is done according to Ch. 2 - Sec. 3 - B500 and Ch. 2
- Sec. 7 - C200 - DNV STANDARD FOR CERTIFICATION No.2.22 - LIFTING
APPLIANCES - June 2013.

The Dynamic Safety Factor SF of wire ropes for both running and standing
application is bigger value given by the following expressions:

10
3 5
0.885 ∙ 1910

2.3 ∙
where:
 is Dynamic Factor of the Crane
 is Safe Working Load of Crane, in kN.

Where the static submersed load measured at the crane tip (F ) exceeds SWL,
SWL should be substituted by F in the above equation.

The minimum breaking load MBL is given by the following expression:


where:
 is safety factor of wire rope required.
 is the static load in the wire rope taking due account of the friction in
the sheaves over which the wire rope passes.

1.3 Offshore Conditions / 1.7 Subsea Conditions

60000 588.6
100
& 1000 9.81

∅54 14.1 ⁄ 1410 13.8

588.6 13.8 602.4

1.5% sheaves with anti-friction bearing



 OFFSHORE:

2.3 ∙ 2.99
(OFFSHORE) 588.6 9.81 598.41
4.11
. ∙

∙ . with: 1.015 ∙ 635.13

 SUBSEA:

2.3 ∙ 3.91
(OFFSHORE) 588.6 13.8 9.81 612.2
4.09
. ∙

∙ . with: 1.015 ∙ 649.77