You are on page 1of 2

PD1096- signed by Ferdinand Marcos (feb. 19, 1977) revising RA 6541 a.

Vicinity map
b. Site development plan
Chapter 1- general provision- all about safeguard life, health, property
c. Perspective
Chapter 2- administration and enforcement- d. Floor plan
e. Elevations
Chapter 3- permits and inspection f. Sections
Chapter 4- types of construction g. Reflected ceiling plan
h. Details in the form of plans, elevations/sections
 Type 1- wood construction i. Schedule of doors and windows
 Type 2- wood construction with fire-resistant materials j. Schedule of finishes
 Type 3- masonry and wood construction
 Type 4- steel, iron, concrete or masonry (type 1- type 4 one-hour Types of vent
fire resistive) - Wind turbine
 Type 5- same as type 4 but shall be fire resistive - Soffit vent
- Power vent
Chapter 5- requirements of fire zones
- Gable vent
Chapter 6- fire-resistive requirements in construction - Solat attic fan
- Cupola vent
Chapter 7- classification and general requirements of all buildings
Section 704- location on property
 Group a- residential dwelling
 Group b- dwelling more than 10 persons (hotels and apartment Section 708- min. req. for group A dwellings
 Group c- schools and education
Section 804- min. setbacks
 Group d- institutional(government and health services like hospitals
 Group e- business ad mercantile/ commercial Section 805: air vent height not less than 2.4m, one storey 2.7 and
 Group f- industrial with non-explosive materials second story 2.4m
 Group g- storage and hazardous
Section 806- sizes and dimensions of rooms
 Group h- assembly less than 1000
 Group i- assembly load 1000 or more Section 807- air space req.
 Group j-1- agricultural
Section 808- window openings
 Group j-2- accessories
Section 1007- doors, and windows

Chapter 8- light and ventilation Section 1207- stairs, exits and occupants

Chapter 9- sanitation

Old IRR-civil or architect NEW IRR- architect (signing docs.)


Types of lot 6. Accessible signage
7. Accessible communication
 Interior lot- surrounded by 3 other lots and has one frontage on a
street
 Inside lot- surrounded by 3 other lots and has one frontage on a
A.general provisions
street
 Corner lot- located at the intersection of two streets
 Through lot- with frontage on more than one street
 Corner-Through lot- abuts street and alleys on 3 sides
 Corner lot abutting 3 or more streets, alleys, rivers, etc.
 End lot

Courts- occupied space between building lines and lot lines other than yard

yard- req. open space left between the outermost face of the building

setbacks- horizontal distance, measured at right angles from a lot line to the
closest wall of any building on same lot

RESIDENTIAL ZONING CLASSIFICATION

R1- low ensity residential (single family)

R2- medium density residential (low-rise, muti-family dwelling)

R3- high density residential (medium-rise, multi-family dwelling)

R4- medium to high density residential (low-rise townhouse for multi-


dwelling)

R5- very high density residential (condominium buildings)

BP 344- accessibility law

Mininum requirements

1. Accessible entrance
2. Accessible parking
3. Accessible routes
4. Accessible toilets
5. Accessible elevators

You might also like