LEGENDS:

LOAD DESCRIPTION

#
PB

SCHEDULE OF LOADS CO

ACU

SHORT CIRCUIT CALCULATION

If.l.= 25 * 1000
240
= 104.167 Amp. GENERAL NOTES & SPECS
LIGHTING LAYOUT PLAN POWER LAYOUT PLAN M= 100/1.5*0.9 = 74.07 1. ALL ELECTRICAL INSTALLATION HEREIN SHALL SHALL BE DONE IN ACCORDANCE WITH THE PROVISION OF THE
LATEST EDITION OF THE PHILIPPINE
SCALE 1:100 MTS SCALE 1:100 MTS ELECTRICAL CODE, THE RULES, REGULATIONS AND REQUIREMENTS OF THE LOCAL POWER COMPANY AND THE
LAWS AND ORDINANCES OF THE LOCAL ENFORCING AUTHORITY.
Is.c(fl) = 104.167 x 74.07 2. THE TYPE OF POWER SERVICE TO BE SUPPLIED SHALL BE 230V, 1Ø, 2W+GROUND, 60 HZ.

Is.c(fl) = 7,715.65 Amp. 3. ALL CONDUCTORS SHALL BE COPPER, TYPE THHN/THWN 90°C 600 VOLT INSULATION FOR LINE WIRES AND TYPE TW FOR
GROUND WIRES MINIMUM
SIZE SHALL BE 3.5MM² FOR LINE WIRES AND 2.0MM FOR LINE WIRES AND 2.0MM² SQAURE. UNLESS OTHERWISE SPECIFIED.
PHELPSDODGE OR APPROVED EQUIVALENT.

4. ALL MATERIALS SHALL BE BRAND NEW AND OF THE APPROVED TYPE IN ACCORDANCE WITH THE DRAWINGS AND
Values of Conductor @ 2AWG SPECIFICATION AND MUST BE SUIT FOR THE LOCATION AND INTENDED PURPOSE.

C= 5,907 5. UNLESS OTHERWISE INDICATED, ALL WIRING SHALL BE IN RIGID PVC, FLEXIBLE METAL CONDUIT AND RIGID METAL
CONDUIT.
CONDUIT MINIMUM SIZE SHALL BE:
- RIGID uPVC, 20MM DIAMETER FOR LIGHTING AND POWER EMBEDDED AND CONCEALED IN
GENERAL LIGHTING LOAD @ 100 VA/OUTLET = 2,000 VA f = 2 x L x Is.c(fl)/C x n x VL-L CONCRETE(EMERALD/ANY APPROVED EQUIVALENT).
- FLEXIBLE METAL CONDUIT, 15MM DIAMETER FOR
SMALL APPLIANCES LOAD @ 180 VA/OUTLET = 3,960 VA - LIGHTING FIXTURES CONNECTION (PANASONIC/ANY APPROVED EQUIVALENT).
- RMC CONDUIT FOR EXPOSED INSTALLATION (PANASONIC/ANY APPROVED EQUIVALENT).
= 5,960 VA / 230 V f = 2 x 98.40 x 7,715.65/5,907 x 1 x 240 6. ALL ELECTRICAL WORKS SHALL BE DONE UNDER THE DIRECT SUPERVISION OF A DULY LICENSED / REGISTERED

TOTAL = 25.91 AMPS. f = 1.07 PROFESSIONAL ELECTRICAL ENGINEER.

8. ALL FEEDERS SHALL BE INSTALLED AS INDICATED ON PLANS BRANCH CIRCUITS HOMERUN WIRES SHALL BE
INSTALLED IN INDIVIDUAL HOMERUN.
M = 1/1+1.07 9. FOR EACH SPARE BRANCH CIRCUIT IN PANEL BOARD, PROVIDE ONE 20MM Ø EMPTY CONDUIT TERMINATED TO
M APPLICATION OF DEMAND FACTOR: = 0.48 100MM OCTAGONAL BOX ABOVE CEILING.

10. WHENEVER NECESSARY PULLBOX SHALL BE PROVIDED EVEN IF NOT INDICATED IN PLANS.

FIRST 3000 VA @ 100% D.F. = 3,000 VA Is.c.(L-L) = 7,715.65 x 0.48


11. THE MOUNTING HEIGHTS OF WIRING DEVICES SHALL BE AS FOLLOWS:

REMAINDER @ 35% = 1,050 VA Is.c.(L-L) = 3,703.51 Amp.


A.) LIGHT SWITCHES . . . . . . . . . . . . 1.40M ABOVE FLOOR FINISH
B.) CONVENIENCE OUTLET . . . . . . . . . 0.30M ABOVE FLOOR FINISH OR AS REQUIRED.
= 4,050 VA C.) PANEL BOARDS AND CABINETS . . 1.80M ABOVE FLOOR FINISH OR AS REQUIRED.
USED : CIRCUIT BREAKER with 4 KAIC RATING D.) KILOWATT HOUR METER . . . . . . . . MIN. OF 1.2 MAX 1.8 ABOVE FINISH FLOOR LINE

OTHER LOADS: Therefore Used 10 KAIC Rating for Market Availability 12. UPON COMPLETION OF COMPLETION OF ELECTRICAL CONSTRUCTION WORKS, THE FOLLOWING TEST SHALL BE PERFORMED BY THE
CONTRACTOR INCLUSIVE OF THE
INSTALLATION TO BE REPORTED IN DETAILS ON FORMS APPROVED BY THE OWNNER'S REPRESENTATIVE:

1 - REF = 2,475 VA
VOLTAGE DROP CALCULATION A INSULATION RESISTANCE TEST
B. OPERATIONAL TEST

L.O 1 2 C.O 3 - ACU = 7,425 VA


C. SYSTEM TEST

ALL MOUNTING HEIGHTS SHALL BE SUBJECTED TO THE ARCHITECTS APPROVAL PRIOR TO INSTALLATION. ANY ALTERATION AND
= 19,910 VA / 230 V VOLTAGE DROP CALCULATION: %VD = (VD/230) * 100 %VD = (VD/230) * 100
CHANGES OF THE DESIGN MUST BE FIRST CONSULTED TO THE DESIGN ENGINEER FOR APPROVAL. IF IN DOUBT PLEASE ASK.

C.O 3 4 REF TOTAL = 86.57 AMPS. %VD = (1.07V/230V) * 100 %VD = (1.81/230V) * 100
LIGHTING OUTLET: %VD = 0.46 %VD = 0.78
VD= 2 x L x R x I / 1000
ACU 5 6 ACU IT = 25.91 (25%) + 86.57 AMPS. VD= 2 x 98ft. x 1.980 x 8.70 / 1000
VD= 3.39 VOLT
ACU 1
VD= 2 x L x R x I / 1000
= 93.05 AMPS. %VD = (VD/230) * 100
VD= 2 x 40ft. x 1.240 x 10.76 / 1000
VD= 0.1.07 VOLT
ACU 7 8 SPARE %VD = (3.39V/230V) * 100
2 2 %VD = 1.47 %VD = (VD/230) * 100
USE: MAIN FEEDER: 2-30mm + 1-5.5mm THW COPPER WIRE %VD = (1.07V/230V) * 100
CONVENIENCE OUTLET:
@ 40mmɸ RSC PIPE VD= 2 x L x R x I / 1000
%VD = 0.46

MAIN CIRCUIT BREAKER: 100 AT, 230V, 2P, 60HZ, MCB VD= 2 x 30ft. x 1.980 x 8.61 / 1000 ACU 2
VD= 1.02 VOLT VD= 2 x L x R x I / 1000
VD= 2 x 40ft. x 1.240 x 10.76 / 1000
%VD = (VD/230) * 100 VD= 0.1.07 VOLT
SINGLE LINE DIAGRAM %VD = (1.02V/230V) * 100
%VD = 0.44 %VD = (VD/230) * 100
%VD = (1.07V/230V) * 100
CONVENIENCE OUTLET: %VD = 0.46
DESIGN COMPUTATION VD= 2 x L x R x I / 1000
VD= 2 x 30ft. x 1.980 x 8.61 / 1000 ACU 3
VD= 1.02 VOLT VD= 2 x L x R x I / 1000
VD= 2 x 40ft. x 1.240 x 10.76 / 1000
%VD = (VD/230) * 100 VD= 0.1.07 VOLT
%VD = (1.02V/230V) * 100
%VD = 0.44 %VD = (VD/230) * 100
%VD = (1.07V/230V) * 100
REF %VD = 0.46
VD= 2 x L x R x I / 1000
VD= 2 x 40ft. x 1.240 x 10.76 / 1000 MAIN LINE:
VD= 1.07 VOLT VD = 2 x L x R x I / 1000
VD = 2 x 50ft. x 0.194 x 93.05 / 1000
VD = 1.81

CONTRACTOR: ENGINEER: PROJECT:TITLE:


PROJECT APPROVED BY: DESIGNED BY: REVISIONS: SHEET CONTENTS: SHEET No.
No. DATE
CADD BY:

SWARA
CORPORATION
SUG MEDIA

PRC No :
SWARA
CORPORATION
SUG MEDIA

SWARA
CORPORATION
SUG MEDIA
PROFESSIONAL ELECTRICAL ENGINEER

PTR No :
PROJECT LOCATION:
OWNER
DATE:
CHECKED BY:
CAD FILE:
E-1
T.I.N. DATE ISSUED :
DATE : PLACE ISSUED : APPROVED BY: