Professional Documents
Culture Documents
HIGH PEAK
PULSE
Copyright © 2018 - ASA srl | All rights reserved. Complete or partial copying, printing and distribution of the information present in this document is prohibited, unless written consent from the owner is granted. 10/2018.
Boosted
MLS®
Homogeneity
of treatment
Game-changing
Technology
MLS®
Corporate Headquarters
Registered Office
HIGH PEAK
PULSE
ASA srl Safety
Via Alessandro Volta, 9
36057 Arcugnano (VI) - Italy
asalaser@asalaser.com
asalaser.com
t. +39 0444 28 92 00
f. +39 0444 28 90 80
Ergonomics
Research Division / Branch
Joint Laboratory and practicality
Department of Experimental and Clinical
Biomedical Sciences
University of Florence
Viale G. Pieraccini, 6
50139 Firenze - Italy
asacampus@asalaser.com Optic fibre
MiS ASA
Since its foundation in 1983, ASAlaser has established itself
internationally in the laser therapy scene for its use in the most
diverse disciplinary fields: from physiotherapy to rehabilitation,
from muscle and joint pain management to sports medicine
and veterinary medicine.
MiS History
Since 2003, with the launch of MLS® ASA now presents MiS: the result of
Laser Therapy (Multiwave Locked the work of a dedicated and competent
System), ASA revolutionises the treatment team that has been able to imagine new
of painful pathologies: the coordinated horizons for laser therapy by concretizing
and synchronized emission of several them into a device with never-before-
laser emissions with different wavelengths seen performance, capable of combining
– pulsed and continuous – allows in fact the synchronized action of MLS®
to focus the action on the therapeutic Laser Therapy with Hilterapia® distinctive
result by modulating and controlling pulsed power.
the emission.
2003
2004
9
MiS
Boosted MLS® Safety
It inherits the proven efficacy and therapeutic The very high instantaneous power, which
superiority of the synchronized emission of MLS® reaches the order of kW, is modulated through
and enhances its power – in particular the peak very short pulses that allow the stimulation
power of the pulsed component – for an even of the therapeutic biological processes while
stronger and deeper action. This opens the doors maintaining control of the thermal effect and
to new therapeutic goals, in particular in the therefore the safety of the treatment, which has
context of peripheral neuropathies. always been an essential requirement for ASA.
The spatial overlap between the different Light, compact, and multifunctional handpiece.
wavelengths ensures the diffusion of the The mechanical connection system of the
MiS energy mix on the irradiated area. optical terminals has been designed to allow
The adopted optical technology allows a immediate interchangeability and is equipped
uniform beam profile and a homogeneous with a recognition sensor to adjust the emission
energy distribution on the target area. parameters automatically.
It has gone beyond the technological state It combines in a single bundle the multisource
of the art by optimizing the fibre coupling of 7 power, maximizing the therapeutic performance.
diode laser sources, pulsed and continuous, Flexible, handy and durable thanks to the internal
reaching peak powers of 1kW and an emission steel sheath.
quality of very high level.
13
MLS®
HIGH PEAK 2
PULSE • Pain Management
Joint problems
Tendinopathies
Muscle pain
Contractures
3 Trigger points
• Peripheral Neuropathies
6
• Edema
• Tissue Lesions
Superficial Wounds
Deep Lesions
7 5
1• HEAD
2• CERVICAL AREA
8 3• SHOULDER
4• ELBOW
5• WRIST - HAND
6• BACK
7• HIP
8• KNEE
9 9• ANKLE - FOOT
15
ACTION
Anti-inflammatory action: treatment with MiS exerts a marked Marked anti-inflammatory action through the reduction
of inflammation mediators.
inhibitory action on the production of pro-inflammatory molecules.
RESULT
Significant decrease in pain, accompanied by functional
Tissue repair action: treatment with MiS accelerates healing times improvement.
and improves the quality of newly formed tissue.
PERIPHERAL NEUROPATHIES
Action on the pain and its causes: treatment with MiS induces a short ACTION
and long-term analgesic effect and promotes a significant and lasting Marked anti-inflammatory effect and lasting analgesic action.
functional recovery because it does not only act on the pain Promotes recovery and trophism of damaged structures.
symptomatology but also on the causes that determine it. RESULT
Significant and persistent improvement of pain symptomatology
and concomitant recovery of functionality.
In addition to the therapeutic characteristics typical of the MLS® family,
MiS finds an application in peripheral neuropathies, as demonstrated EDEMA
by ASACampus scientific research.
ACTION
Modulation of the microcirculation and reduction
The application of MiS in a recognized model of chronic neuropathic pain of the inflammatory component.
shows a clear and lasting reduction in pain symptomatology, accompanied RESULT
by functional recovery. Promotes fluid drainage and resorption of the edema.
From the biological point of view, the treatment with MiS promotes the TISSUE LESIONS: Superficial, Deep.
recovery of the nerve fibres that have been damaged in the lesion area, ACTION
as confirmed by histological and immunohistochemical evaluations. Stimulation of tissue repair processes.
Specifically, sheath reorganization is important both for nerve trophism RESULT
and conduction. Thus, MiS is particularly indicated for the treatment Reduces healing times, improves the quality of the repair tissue
of neuropathic pain. and prevents the formation of fibrotic scarring.
17
MiS technology
TECHNICAL CHARACTERISTICS TROLLEY LASER APPLICATOR
6 Pulsed laser diodes (PW) @905nm Tool-carrying trolley with magnetic 1500 μm optical fibre VISIBLE AND INVISIBLE LASER RADIATION
fixing system AVOID EYE OR SKIN EXPOSURE
TO DIRECT OR SCATTERED RADIATION.
1 Continuous/Frequency-modulated Patent pending mechanical system
laser diode (CW/FW) @808nm 4 swivel wheels with self-locking for rapid connection between CLASS 4 LASER PRODUCT.
system suitable for all floors handpiece and optical terminal, with
Average power (max): 6W ± 20% integrated recognition system
Glasses compartment
Peak power (max): 1kW Ergonomic handpiece with a button
to control the emission and multicolour
LED to indicate the status of the
4 EMISSION METHODS
machine at any time
Synchronized Continuous/Frequency-
modulated and Pulsed at maximum
peak power (MLS® HPP 808+905nm)
Synchronized Continuous/
Frequency-modulated and Pulsed
(MLS® 808+905nm)
Handpiece with 5 cm optical terminal Ø 5 cm
Single Continuous/Frequency-
modulated (808nm) 5 cm diameter homogeneous target area
Single Pulsed (905nm)
Automatic adjustment of the parameters
Frequency: variable according to optimize the intensity on the tissue
to modulation
Ideal for the treatment of large
Intensity: from 1% to 100% anatomical areas homogeneously,
reducing treatment times
Time: from 1 sec to 30 min
FEATURES
Weight: 25 kg
19
MiS software
The innovation of MiS is also expressed The system includes predefined protocols that are dynamically determined
in the user interface, where a high- according to the selected anatomical area, the pathology, the characteristics
resolution 10” touchscreen combines of the patient, and the clinical phase.
with an advanced, versatile,
and intuitive software. Each predefined protocol includes indications of the area to be irradiated with
The high operational flexibility allows it to illustrations and videos; the user can also set the dimensions of the treatment
adapt to the experience of different users
area by drawing it directly on the screen.
and is easily updatable via USB.
Total autonomy for setting the treatment parameters in the manual area
and possibility to set and store programs in the personal area.
ASA srl
Via Alessandro Volta, 9
36057 Arcugnano (VI) - Italy
asalaser@asalaser.com
asalaser.com
t. +39 0444 28 92 00
f. +39 0444 28 90 80
Joint Laboratory
Dipartimento di Scienze
Biomediche Sperimentali e Cliniche
Università di Firenze
Viale G. Pieraccini, 6
50139 Firenze - Italy
asacampus@asalaser.com
FOLLOW US
MLSLASER-MIS.COM