Professional Documents
Culture Documents
ARCHITECTURAL
1 PERSPECTIVE
A100
SITE
STRUCTURAL
SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD
SD
SETOUT POINT
SD
SD
SD
GALERYA
SD
(EXISTING)
SD
SUBSURFACE DRAIN
NEW SEPTIC TANK FOR
SD
SD SD SD SD SD SD SD SD SD
ADMIN BLDG
SD SD SD SD
SD
SD N
DEMOLISH EXISTING SEPTIC TANK
SD
SD
ELECTRICAL
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SUBSURFACE DRAIN
SD
SD
SD
SD
SD
SD
SD
SD
SD
THEATER
(EXISTING)
RA 9514
PROJECT NO. PROJECT TITLE DATE REVISION DESCRIPTION OWNER SHEET CONTENTS SHEET NUMBER
0000 RENOVATION/REPAIR OF AUDITORIUM & UNIVERSITY OF THE PERSPECTIVE, SDP, VICINITY MAP
ARISTOTLE MARC J. GO EXTENSION & REPAINTING OF GALERYA PHILIPPINES BAGUIO
13/11/2012 08:06:21
ARCHITECT
CHECKED BY
KORDILYERA
LOCATION A100
PRC NO: TIN NO: PRC NO: TIN NO:
PTR NO: DATE: PTR NO: DATE: Checker GOVERNMENT CENTER ROAD, BAGUIO CITY
PLACE: PLACE:
13/11/2012 08:06:21 SCALE : As indicated @ A1
THIS DOCUMENT IS THE COPYRIGHT OF 90 DESIGN STUDIO. ALL DIMENSIONS AND SITE CONDITIONS TO BE VERIFIED ON SITE PRIOR TO COMMENCEMENT OF ANY WORK OR PREPARATION OF SHOP DRAWINGS AND/OR THE FABRICATION OF ANY
COMPONENTS. SHOULD THERE BE ANY DISCREPANCIES REFER TO ARCHITECT PRIOR TO COMMENCEMENT OF THE WORK. DO NOT SCALE DRAWINGS - REFER TO FIGURED DIMENSIONS ONLY. DRAWINGS TO BE READ IN CONJUNCTION WITH RELEVENT
DOCUMENTATION FROM ENGINEER AND OTHER SPECIALIST SUB CONSULTANTS. THIS DOCUMENT DESCRIBES THE DESIGN INTENT, DESIGN DETAILS AND / OR FINISHES, SIZES AND RELATIONSHIPS OF ROOMS, BUILDING ENVELOPE AND ARCHITECTURAL
EXPRESSION.
A
A107
A 13,218 B 19,828
400
UP
RW4
3,029
10,926
GALLERY 2
2,979
E
A107
RW3
12,175
B C
3
A106 A106
1 A104
TFL-1 507,120
2,979
2
17,922
4
RW3
49
1,9
5 5
UP
8,936
RW3
GALLERY 1
5,522
D 507,120
A106
507,120 RW4
LEVEL DOWN -200 FROM MUSEUM LEVEL 1
TFL-1
6
GALLERY STORAGE
2,039
RW5
8
EXISTING
AUDITOR
IUM
A A' D E F
PROJECT NO. PROJECT TITLE DATE REVISION DESCRIPTION OWNER SHEET CONTENTS SHEET NUMBER
0000 RENOVATION/REPAIR OF AUDITORIUM & UNIVERSITY OF THE FIRST BASEMENT LEVEL PLAN
ARISTOTLE MARC J. GO EXTENSION & REPAINTING OF GALERYA PHILIPPINES BAGUIO
13/11/2012 08:06:22
ARCHITECT
CHECKED BY
KORDILYERA
LOCATION A101
PRC NO: TIN NO: PRC NO: TIN NO:
PTR NO: DATE: PTR NO: DATE: AMJG GOVERNMENT CENTER ROAD, BAGUIO CITY
PLACE: PLACE:
13/11/2012 08:06:22 SCALE : 1 : 100 @ A1
THIS DOCUMENT IS THE COPYRIGHT OF 90 DESIGN STUDIO. ALL DIMENSIONS AND SITE CONDITIONS TO BE VERIFIED ON SITE PRIOR TO COMMENCEMENT OF ANY WORK OR PREPARATION OF SHOP DRAWINGS AND/OR THE FABRICATION OF ANY
COMPONENTS. SHOULD THERE BE ANY DISCREPANCIES REFER TO ARCHITECT PRIOR TO COMMENCEMENT OF THE WORK. DO NOT SCALE DRAWINGS - REFER TO FIGURED DIMENSIONS ONLY. DRAWINGS TO BE READ IN CONJUNCTION WITH RELEVENT
DOCUMENTATION FROM ENGINEER AND OTHER SPECIALIST SUB CONSULTANTS. THIS DOCUMENT DESCRIBES THE DESIGN INTENT, DESIGN DETAILS AND / OR FINISHES, SIZES AND RELATIONSHIPS OF ROOMS, BUILDING ENVELOPE AND ARCHITECTURAL
EXPRESSION.
G A
--- A107
A 13,218 B 19,828
SETOUT POINT
1
UP
3,029
RW4
2 SW1
10,896
8,986
2,979
E
A107 GALERYA (EXISTING ) 510,700
GALLERY 2
3
B C
510,700 3
A106 A106
1 A104 507,070
2,979
RW5
2
CHB1
4
1,305 2,099 2,099 7,190
508,360
SW2 SW2
9
84
1,
2,199
1,94
9 5
2,100
UP UP
8,936
FL - 01 GALLERY ENTRANCE FL - 01
4,000
SW2 LOBBY
D
510,470
A106
CAFETERIA RW5
510,700
2056
2909
510,370 UP
2,000
510,220
3762
4614
RAMP UP 510,272
5467
510,320
FL - 01 1
A105
510,370
510,470
A A' D E F
PROJECT NO. PROJECT TITLE DATE REVISION DESCRIPTION OWNER SHEET CONTENTS SHEET NUMBER
0000 RENOVATION/REPAIR OF AUDITORIUM & UNIVERSITY OF THE SECOND BASEMENT LEVEL PLAN
ARISTOTLE MARC J. GO EXTENSION & REPAINTING OF GALERYA PHILIPPINES BAGUIO
13/11/2012 08:06:23
ARCHITECT
CHECKED BY
KORDILYERA
LOCATION A102
PRC NO: TIN NO: PRC NO: TIN NO:
PTR NO: DATE: PTR NO: DATE: Checker GOVERNMENT CENTER ROAD, BAGUIO CITY
PLACE: PLACE:
13/11/2012 08:06:23 SCALE : 1 : 100 @ A1
THIS DOCUMENT IS THE COPYRIGHT OF 90 DESIGN STUDIO. ALL DIMENSIONS AND SITE CONDITIONS TO BE VERIFIED ON SITE PRIOR TO COMMENCEMENT OF ANY WORK OR PREPARATION OF SHOP DRAWINGS AND/OR THE FABRICATION OF ANY
COMPONENTS. SHOULD THERE BE ANY DISCREPANCIES REFER TO ARCHITECT PRIOR TO COMMENCEMENT OF THE WORK. DO NOT SCALE DRAWINGS - REFER TO FIGURED DIMENSIONS ONLY. DRAWINGS TO BE READ IN CONJUNCTION WITH RELEVENT
DOCUMENTATION FROM ENGINEER AND OTHER SPECIALIST SUB CONSULTANTS. THIS DOCUMENT DESCRIBES THE DESIGN INTENT, DESIGN DETAILS AND / OR FINISHES, SIZES AND RELATIONSHIPS OF ROOMS, BUILDING ENVELOPE AND ARCHITECTURAL
EXPRESSION.
G F A
--- A107 A107
A B
6609 6609
SETOUT POINT
3029
2
2979
A107
H
A107
3 FL-02
513,580 513,680
2979
4
A' B
A106
D E C
A106
F
3489
6609 6609 6609
513,630 513,630
513,680 513,680
5
513,656
513,452 FL-02
5447
5447
D
A106
513,630
514,680
513,680 513,680 513,680
6
5681
6320
513,730
DN
513,780
D E F
DN
PROJECT NO. PROJECT TITLE DATE REVISION DESCRIPTION OWNER SHEET CONTENTS SHEET NUMBER
13/11/2012 08:06:23
ARCHITECT
CHECKED BY
KORDILYERA
LOCATION A103
PRC NO: TIN NO: PRC NO: TIN NO:
PTR NO: DATE: PTR NO: DATE: Checker GOVERNMENT CENTER ROAD, BAGUIO CITY
PLACE: PLACE:
13/11/2012 08:06:23 SCALE : 1 : 100 @ A1
THIS DOCUMENT IS THE COPYRIGHT OF 90 DESIGN STUDIO. ALL DIMENSIONS AND SITE CONDITIONS TO BE VERIFIED ON SITE PRIOR TO COMMENCEMENT OF ANY WORK OR PREPARATION OF SHOP DRAWINGS AND/OR THE FABRICATION OF ANY
COMPONENTS. SHOULD THERE BE ANY DISCREPANCIES REFER TO ARCHITECT PRIOR TO COMMENCEMENT OF THE WORK. DO NOT SCALE DRAWINGS - REFER TO FIGURED DIMENSIONS ONLY. DRAWINGS TO BE READ IN CONJUNCTION WITH RELEVENT
DOCUMENTATION FROM ENGINEER AND OTHER SPECIALIST SUB CONSULTANTS. THIS DOCUMENT DESCRIBES THE DESIGN INTENT, DESIGN DETAILS AND / OR FINISHES, SIZES AND RELATIONSHIPS OF ROOMS, BUILDING ENVELOPE AND ARCHITECTURAL
EXPRESSION.
150
904
F A
5 4 3 2 sw A107 A107
H E panel
detail
2200
A107 A107 S103
1296
+514,010
200 3289 200 2779 200 2879 1254 1550 ADMIN LVL 1
+513,780
EXG THEATER LVL 3 FFL
+513,580
FL-02 EXG GALERYA LVL 2 FFL
FL-02
2028
B2 200 x 1000
SW2
89
300
1000
SW1
+510,700
EXG GALERYA LVL 1 FFL
2214
+510,470
SW1 EXG THEATER LVL 2 FFL
CHB1
5410
1953 1058 3575 1058 3131 1800
B6 350 x 750mm
4082
1079 1500
300
3580
RW3 RW3 +508,360
2126
RW3
EXG GALERYA LVL 0
1803
+507,850
+507,270
150
150
MUSEUM LEVEL 1
TFL-1 TFL-1
+513,580
FL-02 EXG GALERYA LVL 2 FFL
900
B1 300 x 500
118
7107 246 1936 2081 1204 300
RW5
+510,700
EXG GALERYA LVL 1 FFL
2304
+510,470
EXG THEATER LVL 2 FFL
SW2 SW2
RW3 +508,360
2126
RW3
EXG GALERYA LVL 0
+507,850
EXG THEATER LVL 1
+507,270
MUSEUM LEVEL 1
TFL-1
2 ELEVATION 1-D
A104 1 : 50
PROJECT NO. PROJECT TITLE DATE REVISION DESCRIPTION OWNER SHEET CONTENTS SHEET NUMBER
13/11/2012 08:06:24
ARCHITECT
CHECKED BY
KORDILYERA
LOCATION A104
PRC NO: TIN NO: PRC NO: TIN NO:
PTR NO: DATE: PTR NO: DATE: Checker GOVERNMENT CENTER ROAD, BAGUIO CITY
PLACE: PLACE:
13/11/2012 08:06:24 SCALE : 1 : 50 @ A1
THIS DOCUMENT IS THE COPYRIGHT OF 90 DESIGN STUDIO. ALL DIMENSIONS AND SITE CONDITIONS TO BE VERIFIED ON SITE PRIOR TO COMMENCEMENT OF ANY WORK OR PREPARATION OF SHOP DRAWINGS AND/OR THE FABRICATION OF ANY
COMPONENTS. SHOULD THERE BE ANY DISCREPANCIES REFER TO ARCHITECT PRIOR TO COMMENCEMENT OF THE WORK. DO NOT SCALE DRAWINGS - REFER TO FIGURED DIMENSIONS ONLY. DRAWINGS TO BE READ IN CONJUNCTION WITH RELEVENT
DOCUMENTATION FROM ENGINEER AND OTHER SPECIALIST SUB CONSULTANTS. THIS DOCUMENT DESCRIBES THE DESIGN INTENT, DESIGN DETAILS AND / OR FINISHES, SIZES AND RELATIONSHIPS OF ROOMS, BUILDING ENVELOPE AND ARCHITECTURAL
EXPRESSION.
B D E F
B C
A106 A106
19828
1000 1000
620
200 300 NW-03
1000
+514,010
ADMIN LVL 1
300 80
230
+513,780
200
EXG THEATER LVL 3 FFL
100
+513,580
EXG GALERYA LVL 2 FFL
750
12
00
900
NW-03
3540
3310
300
RW5
2460
2682 1516 2393
+510,700
EXG GALERYA LVL 1 FFL
230
12
+510,470
00
EXG THEATER LVL 2 FFL
1 ELEVATION 2-A
A105 1 : 50
PROJECT NO. PROJECT TITLE DATE REVISION DESCRIPTION OWNER SHEET CONTENTS SHEET NUMBER
13/11/2012 08:06:24
ARCHITECT
CHECKED BY
KORDILYERA
LOCATION A105
PRC NO: TIN NO: PRC NO: TIN NO:
PTR NO: DATE: PTR NO: DATE: Checker GOVERNMENT CENTER ROAD, BAGUIO CITY
PLACE: PLACE:
13/11/2012 08:06:24 SCALE : 1 : 50 @ A1
THIS DOCUMENT IS THE COPYRIGHT OF 90 DESIGN STUDIO. ALL DIMENSIONS AND SITE CONDITIONS TO BE VERIFIED ON SITE PRIOR TO COMMENCEMENT OF ANY WORK OR PREPARATION OF SHOP DRAWINGS AND/OR THE FABRICATION OF ANY
COMPONENTS. SHOULD THERE BE ANY DISCREPANCIES REFER TO ARCHITECT PRIOR TO COMMENCEMENT OF THE WORK. DO NOT SCALE DRAWINGS - REFER TO FIGURED DIMENSIONS ONLY. DRAWINGS TO BE READ IN CONJUNCTION WITH RELEVENT
DOCUMENTATION FROM ENGINEER AND OTHER SPECIALIST SUB CONSULTANTS. THIS DOCUMENT DESCRIBES THE DESIGN INTENT, DESIGN DETAILS AND / OR FINISHES, SIZES AND RELATIONSHIPS OF ROOMS, BUILDING ENVELOPE AND ARCHITECTURAL
EXPRESSION.
G A
--- A107
A A' B D E F
6307 33046
3,500 1,819
150
150
600
EXISTING GALERYA
904
EXTERIOR AND INTERIOR WALLS REPAINTED
+513,780
1,296
EXG THEATER LVL 3 FFL
+514,010
ADMIN LVL 1
+513,580
EXG GALERYA LVL 2 FFL
1,323 2,936 220 5,642 1,800
980
2,460
0
+510,700
2,325
1,000
EXG GALERYA LVL 1 FFL
770
+510,470
230
EXG THEATER LVL 2 FFL
+508,360
EXG GALERYA LVL 0
2,126
200
+507,270
MUSEUM LEVEL 1
1 SECTION D
A106 1 : 100
6 5
5,447
5 6
230
1,000
ADMIN LVL 1
+513,780 +513,780
330
EXG THEATER LVL 3 FFL EXG THEATER LVL 3 FFL
100
+513,580
100
+513,580
800
1,227
2410
1,983
0 +510,700
+510,700
EXG GALERYA LVL 1 FFL EXG GALERYA LVL 1 FFL
+510,470 +510,470
EXG THEATER LVL 2 FFL EXG THEATER LVL 2 FFL
CHE
CK
34 . 0
0°
3,200
+508,360
EXG GALERYA LVL 0
+508,360
TOP OF GRADE BEAM
580 510
+507,850 +507,850
EXG THEATER LVL 1 EXG THEATER LVL 1
+507,270
200
MUSEUM LEVEL 1
+507,270
MUSEUM LEVEL 1
2 SECTION C 3 SECTION B
A106 1 : 100 A106 1 : 100
PROJECT NO. PROJECT TITLE DATE REVISION DESCRIPTION OWNER SHEET CONTENTS SHEET NUMBER
13/11/2012 08:06:25
ARCHITECT
CHECKED BY
KORDILYERA
LOCATION A106
PRC NO: TIN NO: PRC NO: TIN NO:
PTR NO: DATE: PTR NO: DATE: Checker GOVERNMENT CENTER ROAD, BAGUIO CITY
PLACE: PLACE:
13/11/2012 08:06:25 SCALE : 1 : 100 @ A1
THIS DOCUMENT IS THE COPYRIGHT OF 90 DESIGN STUDIO. ALL DIMENSIONS AND SITE CONDITIONS TO BE VERIFIED ON SITE PRIOR TO COMMENCEMENT OF ANY WORK OR PREPARATION OF SHOP DRAWINGS AND/OR THE FABRICATION OF ANY
COMPONENTS. SHOULD THERE BE ANY DISCREPANCIES REFER TO ARCHITECT PRIOR TO COMMENCEMENT OF THE WORK. DO NOT SCALE DRAWINGS - REFER TO FIGURED DIMENSIONS ONLY. DRAWINGS TO BE READ IN CONJUNCTION WITH RELEVENT
DOCUMENTATION FROM ENGINEER AND OTHER SPECIALIST SUB CONSULTANTS. THIS DOCUMENT DESCRIBES THE DESIGN INTENT, DESIGN DETAILS AND / OR FINISHES, SIZES AND RELATIONSHIPS OF ROOMS, BUILDING ENVELOPE AND ARCHITECTURAL
EXPRESSION.
E H D
E
A107 A107 A106
A107
1 2 3 4 5 6 1 2 3 4 5 6
17,922
17922
3,029 2,979 2,979 3,489 5,447
3029 2979 2979 3489 5447
-
---
+514,010
ADMIN LVL 1
+513,780
EXG THEATER LVL 3 FFL
+513,580
800 200
EXG GALERYA LVL 2 FFL
1000
450
300
3210
1,980
2,410
1980
1,000
+510,700
EXG GALERYA LVL 1 FFL
2,304
6410
+510,470
EXG THEATER LVL 2 FFL
930
230
5410
-
---
3200
+508,360
EXG GALERYA LVL 0
2506
+507,850
EXG THEATER LVL 1
+507,270
150
MUSEUM LEVEL 1
1 SECTION F 3 SECTION A
A107 1 : 100 A107 1 : 100
B A F G
A106 A107 A107 ---
F A
A107 A107
D B A' A
19828 A B
6609 6609 6609 1782
13,218
750
EXISTING GALERYA
1,054
246 220
723 1716 2081 1323 1632
+514,010
ADMIN LVL 1
1,196
+513,780
EXG THEATER LVL 3 FFL
+513,580
EXG GALERYA LVL 2 FFL
1000
1932
1980
GALLERY 2 +510,700
5420
EXG GALERYA LVL 1 FFL
1543
2304
+510,470
EXG THEATER LVL 2 FFL
+508,360
2126
1090
1035
2 SECTION H 4 SECTION E
A107 1 : 100 A107 1 : 100
PROJECT NO. PROJECT TITLE DATE REVISION DESCRIPTION OWNER SHEET CONTENTS SHEET NUMBER
13/11/2012 08:06:27
ARCHITECT
CHECKED BY
KORDILYERA
LOCATION A107
PRC NO: TIN NO: PRC NO: TIN NO:
PTR NO: DATE: PTR NO: DATE: Checker GOVERNMENT CENTER ROAD, BAGUIO CITY
PLACE: PLACE:
13/11/2012 08:06:27 SCALE : 1 : 100 @ A1
THIS DOCUMENT IS THE COPYRIGHT OF 90 DESIGN STUDIO. ALL DIMENSIONS AND SITE CONDITIONS TO BE VERIFIED ON SITE PRIOR TO COMMENCEMENT OF ANY WORK OR PREPARATION OF SHOP DRAWINGS AND/OR THE FABRICATION OF ANY
COMPONENTS. SHOULD THERE BE ANY DISCREPANCIES REFER TO ARCHITECT PRIOR TO COMMENCEMENT OF THE WORK. DO NOT SCALE DRAWINGS - REFER TO FIGURED DIMENSIONS ONLY. DRAWINGS TO BE READ IN CONJUNCTION WITH RELEVENT
DOCUMENTATION FROM ENGINEER AND OTHER SPECIALIST SUB CONSULTANTS. THIS DOCUMENT DESCRIBES THE DESIGN INTENT, DESIGN DETAILS AND / OR FINISHES, SIZES AND RELATIONSHIPS OF ROOMS, BUILDING ENVELOPE AND ARCHITECTURAL
EXPRESSION.
A B
RC1 450 x450 RC1 450 x450
13,218
RF - 3000x300
475
1
C4 300 x 300mm
2225
RW4
RF - 3000x300
3,029
RF - 3000x300
RC1 450 x450 RC1 450 x450
GB 300 x 500
RF - 3000x300
RF - 3000x300
2,979
RW3
RC1 450 x450 RC1 450 x450
GB 300 x 500
RF - 3000x300
RF - 3000x300
3
RW3
2,979
GB 300 x 500
RF - 3000x300
RF - 3000x300
RC2 450 x 450 CC 1 450mmØ RC2 450
RW3x 450 RC2 RW3
450 x 450 RC2 450 RW3
x 450 RC2 450 x 450
375
5
2600
8,936
2225
RF - 3000x300 RF - 3000x300 RF - 3000x300 RF - 3000x300
F1 2000 x 2000 x 300mm
RF - 3000x300
GB 300 x 500
GB 300 x 500
GB 300 x 500
GB
RW4
30
0x
50
0
CC 1 450mmØ CC 1 450mmØ CC 1 450mmØ CC 1 450mmØ CC 1 450mmØ RC2 450 x 450
F1 2000 x 2000 x 300mm
GB 300 x 500 GB 300 x 500 GB 300 x 500 GB 300 x 500 GB 300 x 500
CC 1 450mmØ
F1 2000 x 2000 x 300mm
GB 300 x 500
F1 2000 x 2000 x 300mm F1 2000 x 2000 x 300mm F1 2000 x 2000 x 300mm
CC 1 450mmØ
8
RF - 3000x300
GB 300 x
500
GB 300 x 500
CC 1 450mmØ
GB 300 x
GB 300 x 500
500 RF - 3000x300
F1 2000 x 2000 x 300mm
CC 1 450mmØ
GB 300 x RW4
500
F1 2000 x 2000 x 300mm
CC 1 450mmØ
GB 300 x
500
F1 2000 x 2000 x 300mm
RC2 450 x 450
GB 300 x
500
RW5 F1 2000 x 2000 x 300mm
33,046
A A' D E F
PROJECT NO. PROJECT TITLE DATE REVISION DESCRIPTION OWNER SHEET CONTENTS SHEET NUMBER
13/11/2012 08:06:27
CHECKED BY
KORDILYERA
LOCATION S100
PRC NO: TIN NO: PRC NO: TIN NO:
PTR NO: DATE: PTR NO: DATE: Checker GOVERNMENT CENTER ROAD, BAGUIO CITY
PLACE: PLACE:
13/11/2012 08:06:27 SCALE : 1 : 80 @ A1
THIS DOCUMENT IS THE COPYRIGHT OF 90 DESIGN STUDIO. ALL DIMENSIONS AND SITE CONDITIONS TO BE VERIFIED ON SITE PRIOR TO COMMENCEMENT OF ANY WORK OR PREPARATION OF SHOP DRAWINGS AND/OR THE FABRICATION OF ANY
COMPONENTS. SHOULD THERE BE ANY DISCREPANCIES REFER TO ARCHITECT PRIOR TO COMMENCEMENT OF THE WORK. DO NOT SCALE DRAWINGS - REFER TO FIGURED DIMENSIONS ONLY. DRAWINGS TO BE READ IN CONJUNCTION WITH RELEVENT
DOCUMENTATION FROM ENGINEER AND OTHER SPECIALIST SUB CONSULTANTS. THIS DOCUMENT DESCRIBES THE DESIGN INTENT, DESIGN DETAILS AND / OR FINISHES, SIZES AND RELATIONSHIPS OF ROOMS, BUILDING ENVELOPE AND ARCHITECTURAL
EXPRESSION.
B1 300 x 500
13,218
1
C3 200 x 200
UP
B1 300 x 500
3,029
RW5
RW4
RC1 450 x450
C4 300 x 300mm
2
RC1 450 x450
B1 300 x 500
B1 300 x 500
RC1 450 x450
2,979
RW3
B1 300 x 500
B1 300 x 500
RC1 450 x450
2,979
RW3
RW3
B1 300 x 500
B1 300 x 500
RW5
RC2 450 x 450 CC 1 450mmØ RC2 450 x 450 RC2 450 x 450 RC2 450 x 450
B6 350 x 750mm
5
B1 300 x 500 B1 300 x 500 B1 300 x 500
UP UP
8,936
B1 300 x 500
B1 300 x 500
B1 300 x 500 B1 300 x 500 B1 300 x 500
B2 300 x 600mm
B2 300 x 600mm
RW4
6
8 CC 1 450mmØ
B4 300 x 400
CC 1 450mmØ
UP
B4 300 x
400 CC 1 450mmØ
B2 300 x 600mm
B2 300 x 600mm
B4 300 x
400
CC 1 450mmØ
RW4
CC 1 450mmØ
33,046
A A' B D E F
PROJECT NO. PROJECT TITLE DATE REVISION DESCRIPTION OWNER SHEET CONTENTS SHEET NUMBER
13/11/2012 08:06:27
CHECKED BY
KORDILYERA
LOCATION S101
PRC NO: TIN NO: PRC NO: TIN NO:
PTR NO: DATE: PTR NO: DATE: Checker GOVERNMENT CENTER ROAD, BAGUIO CITY
PLACE: PLACE:
13/11/2012 08:06:27 SCALE : 1 : 80 @ A1
THIS DOCUMENT IS THE COPYRIGHT OF 90 DESIGN STUDIO. ALL DIMENSIONS AND SITE CONDITIONS TO BE VERIFIED ON SITE PRIOR TO COMMENCEMENT OF ANY WORK OR PREPARATION OF SHOP DRAWINGS AND/OR THE FABRICATION OF ANY
COMPONENTS. SHOULD THERE BE ANY DISCREPANCIES REFER TO ARCHITECT PRIOR TO COMMENCEMENT OF THE WORK. DO NOT SCALE DRAWINGS - REFER TO FIGURED DIMENSIONS ONLY. DRAWINGS TO BE READ IN CONJUNCTION WITH RELEVENT
DOCUMENTATION FROM ENGINEER AND OTHER SPECIALIST SUB CONSULTANTS. THIS DOCUMENT DESCRIBES THE DESIGN INTENT, DESIGN DETAILS AND / OR FINISHES, SIZES AND RELATIONSHIPS OF ROOMS, BUILDING ENVELOPE AND ARCHITECTURAL
EXPRESSION.
9725
B1 300 x 500
B5 200 x 300mm
1
B5 200 x 300mm
B5 200 x 300mm
B5 200 x 300mm
C3 200 x 200
B4 300 x 400
B1 300 x 500
3029
RC1 450 x450 RC1 450 x450
B1 300 x 500
B1 300 x 500
2979
RC1 450 x450 RC1 450 x450
B5 200 x 300mm
B5 200 x 300mm B2 200 x 1000
-
3
B1 300 x 500
B1 300 x 500
2979
B1 300 x 500
B1 300 x 500
3489
RC2 450 x 450 CC 1 450mmØ RC2 450 x 450 RC2 450 x 450 RC2 450 x 450 RC2 450 x 450
B4 300 x 400 B2 200 x 1000 B2 200 x 1000 B1 300 x 500 B1 300 x 500 B1 300 x 500
5 5
B6 350 x 750mm
B6 350 x 750mm
B5 200 x 300mm
B6 350 x 750mm
B6 350 x 750mm
B1 300 x 500
B1 300 x 500
B1 300 x 500 B1 300 x 500 B1 300 x 500
B6 350 x 750mm
B1 300 x 500
5447
B6 350 x 750mm B6 350 x 750mm B6 350 x 750mm B6 350 x 750mm B6 350 x 750mm B6 350 x 750mm
6 6
B6 350 x 750mm
2056
B6 350 x 750mm
CC 1 450mmØ
CC 1 450mmØ
B1 300 x
500
33046
8
S102 1 : 100
PROJECT NO. PROJECT TITLE DATE REVISION DESCRIPTION OWNER SHEET CONTENTS SHEET NUMBER
0000 RENOVATION/REPAIR OF AUDITORIUM & UNIVERSITY OF THE DECK LEVEL FRAMING PLAN
ARISTOTLE MARC J. GO EXTENSION & REPAINTING OF GALERYA PHILIPPINES BAGUIO
13/11/2012 08:06:28
ARCHITECT
CHECKED BY
KORDILYERA
LOCATION S102
PRC NO: TIN NO: PRC NO: TIN NO:
PTR NO: DATE: PTR NO: DATE: Checker GOVERNMENT CENTER ROAD, BAGUIO CITY
PLACE: PLACE:
13/11/2012 08:06:28 SCALE : 1 : 100 @ A1
THIS DOCUMENT IS THE COPYRIGHT OF 90 DESIGN STUDIO. ALL DIMENSIONS AND SITE CONDITIONS TO BE VERIFIED ON SITE PRIOR TO COMMENCEMENT OF ANY WORK OR PREPARATION OF SHOP DRAWINGS AND/OR THE FABRICATION OF ANY
COMPONENTS. SHOULD THERE BE ANY DISCREPANCIES REFER TO ARCHITECT PRIOR TO COMMENCEMENT OF THE WORK. DO NOT SCALE DRAWINGS - REFER TO FIGURED DIMENSIONS ONLY. DRAWINGS TO BE READ IN CONJUNCTION WITH RELEVENT
DOCUMENTATION FROM ENGINEER AND OTHER SPECIALIST SUB CONSULTANTS. THIS DOCUMENT DESCRIBES THE DESIGN INTENT, DESIGN DETAILS AND / OR FINISHES, SIZES AND RELATIONSHIPS OF ROOMS, BUILDING ENVELOPE AND ARCHITECTURAL
EXPRESSION.
A. GENERAL NOTES
1. GENERAL NOTES & TYPICAL STRUCTURAL DETAILS SHALL APPLY TO ALL DRAWINGS UNLESS OTHERWISE SHOWN OR NOTED. 1. BARS SHALL BE CLEAN OF RUST, GREASE OR OTHER MATERIALS LIKELY TOIMPAIR BOND. ALL REINFORCING BAR BENDS
2. FEATURES OF CONSTRUCTION SHOWN ARE TYPICAL & SHALL APPLY GENERALLY THROUGHOUT FOR SIMILAR CONDITIONS. SHALL BE MADE COLD.
MODIFY TYPICAL DETAILS AS REQUIRED TO MEET SPECIAL CONDITIONS. 2. ALL GRADE 60 REINFORCING STEEL SHALL BE CLEARLY MARKED TO DIFFERENTIATE THEM FROM GRADE 40 REINFORCING
3. THE CONTRACTOR SHALL EXAMINE THE DRAWINGS & SHALL NOTIFY THE ENGINEER / ARCHITECT OF ANY DISCREPANCIES HE STEEL IF CONCURRENTLY ON SITE.
MAY FIND BEFORE PROCEEDING WITH THE WORK OR DURING CONSTRUCTION. 3. IN GENERAL, BAR SPLICES SHALL BE MADE AT POINTS OF MINIMUM STRESS.SPLICES SHALL BE SECURELY WIRED
4. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO PROVIDE ADEQUATE SHORING & BRACING. TOGETHER. STAGGER SPLICES AT LEAST 600 mm. WHENEVER POSSIBLE IN BEAMS AND SLABS SPLICE TOP BARS AT MID A
5. ALL MATERIALS & WORKMANSHIP SHALL CONFORM TO THE LATEST APPLICABLE STANDARDS OR SPECIFICATIONS. ALL WORKS SPAN AND BOTTOM BARS NEAR SUPPORT. SPLICE OF REINFORCEMENT SHALL BE MADE ONLY AS REQUIRED OR
SHALL CONFORM WITH THE BEST PRACTICE PREVAILING IN THE VARIOUS TRADES. PERMITTED ON DESIGN DRAWINGS OR AS ALLOWED BY THE ACI CODE OR AS AUTHORIZED BY THE ENGINEER.
6. INSPECTION-ALL CONSTRUCTION & WORKMANSHIP SHALL BE SUBJECT TO INSPECTION, EXAMINATION & TESTING BY THE 4. BARS NOTED AS "CONT. " SHALL HAVE A MINIMUM SPLICE LENGTH OF 42 BAR DIAMETERS BUT NOT LESS THAN 600 mm ,
ENGINEER / ARCHITECT.THE ENGINEER / ARCHITECT SHALL HAVE THE RIGHT TO REJECT DEFECTIVE MATERIALS & UNLESS OTHERWISE NOTED.
WORKMANSHIP OR REQUIRE ITS CORRECTION. 5. REINFORCING SHALL BE SPLICED ONLY AS INDICATED ON THE DRAWINGS.
7. UNLESS SPECIFICALLY DETAILED ELSEWHERE CONTRACTOR SHALL FOLLOW TYPICAL DETAILS AS SHOWN IN THESE 6. MINIMUM CONCRETE COVER FOR REINFORCING BARS SHALL BE.
DRAWINGS.
8. THE CONTRACTOR WILL BE RESPONSIBLE FOR THE COORDINATION OF WORK AMONG THE VARIOUS TRADES AS NECCESSARY
TO AVOID CONFLICTS & TO INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE. ITEMS COVER
9. DO NOT SCALE DRAWINGS. CALLED-OUT DIMENSIONS & STANDARD CODE REQUIREMENTS SHALL GOVERN OVER UN SCALED
DRAWINGS. CONCRETE CAST AGAINST EARTH 75 mm
10.SPECIAL NOTE: DIMENSIONS INDICATED ON THE STRUCTURAL DRAWINGS SHALL BE COORDINATED WITH THE ARCHITECTURAL
DRAWINGS. ARCHITECTURAL DRAWINGS SHALL BE USED TO DEFINE DETAIL CONFIGURATIONS, ELEVATIONS, OPENINGS, EXPOSED TO EXTERIOR WEATHER 38 mm
JOINTS,SLOPES, ETC.
11.THE CONTRACTOR IS GIVEN THE OPTION TO UTILIZE ALTERNATIVE METHODS OF DESIGN & ALTERNATIVE METHOD OF -
FORMED SURFACE BELOW GRADE 50 mm ---
CONSTRUCTION AS DEEMED SUITABLE PROVIDED THAT SUCH OPTION IS IN CONFORMITY WITH THE DESIGN CONCEPT OF THE
PROJECT & IS COMPLIANT WITH THE INFORMATION GIVEN IN THE CONTRACT DOCUMENTS. SLAB ON GRADE 50 mm
LOCATION STRUCTURAL ELEMENTS 28-DAY COMPREHENSIVE STRENGTH DENSITY MAX. LUMP 7. ANY WELDING TO BE PERFORMED MUST HAVE PRIOR WRITTEN APPROVAL OF THE ENGINEER.
8. WELDING OF REINFORCING STEEL IS NOT PERMITTED UNLESS OTHERWISE SHOWN ON THE DRAWINGS. WELDING
OF REINFORCING STEEL SHALLCONFIRM TO AWS D1.4-79 "AWS STRUCTURAL WELDING CODE-REINFORCING
FOUNDATION FOOTINGS 3000 PSI 150 PCF 4" (100mm)
STEEL" OF THE AMERICAN WELDING SOCIETY. REINFORCING STEEL NOT CONFIRMING TO ASTM A 706 MAY BE
FOOTING TIE BEAMS
USED IF MATERIAL PROPERTIES OF THE REINFORCING STEEL CONFIRM TO AWS D1-79.
RETAINING WALLS
9. SHOP DRAWINGS: THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR REINFORCNG STEEL PREPARED IN
ACCORDANCE WITH ACI 315. INDICATE BENDING DIAGRAM, ASSEMBLY DIAGRAM, SPLICING, AND LAPS OF SW PANEL WITH
SLAB, BEAMS ROOTS AND SHAPES DIMENSIONS AND DETAILS FOR REINFORCING BARS. ANCHOR BOLTS, DOWELS AND OTHER 12mmØ REBAR
GROUND TO ROOF
COLUMNS, RAMPS 3500 PSI 150 PCF 4" (100mm) EMBEDDED ITEMS ARE TO BE SECURELY TIED IN PLACE BEFORE CONCRETE IS POURED.
SPACED @600mm
RC WALLS
D. STRUCTURAL STEEL
SCHEDULE OF CONCRETE AGGREGATES
1. ALL STRUCTURAL MILL SECTIONS BUILT UP PLATE SECTION SHALL BE DESIGNED IN ACCORDANCE WITH AISC'S LATEST
AGGREGATE SIZE SPECIFICATION FOR THE DESIGN. FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS. +510,470
ITEMS 2. DESIGN LOADS FOR BUILDINGS SHALL MEET THE REQUIRED STRUCTURAL DESIGN CRITERIA. EXG THEATER LVL 2 FFL
FOOTING TIE BEAM 3/4" (19mm) 3. STEEL PLATES, SHAPES, BARS AND METAL FABRICATIONS: ASTM A-36.
4. STRUCTURAL BOLTS AND NUTS: ASTM A-325, GALVANIZED. 7/8DIAMETER AND BELOW. A-490 1" DIAMETER AND ABOVE.
SLAB BEAMS, COLUMNS, RAMPS 5. ELECTRODES FOR WELDING: ASTM A233 E _60XX SERIES; COMPLY WITH AWS D1.1 CODE REQUIREMENTS.
3/4" (19mm) 6. FLAME CUTTING AND WELDING SHALL BE DONE IN ACCORDANCE WITH LATEST " STANDARD CODE FOR WELDING IN
RC WALLS, RETAINING WALLS
BUILDING CONSTRUCTION" OF THE AMERICAN WELDING SOCIETY.
7. ALL BUTT WELDS SHALL BE FULL PENETRATION WELDS AND SHALL BE PROPERLYBACK-CHIPPED OR GOUGED. BACK-
CURBS & MASS UPPLATES SHALL BE PROVIDED AS REQUIRED.
CONCRETE
1" (25mm) MONOLITHIC STAIRS
8. SHOP PAINTING FOR STRUCTURAL STEEL BE RUST INHIBIT PRIMER WITH MINIMUM D.F.T. OF 2.0 MILS.
9. TOUCH-UP PAINTING : APPLY PAINT TO EXPOSED AREAS IN MANNER SATISFACTORY TO THE ENGINEER WITH SAME
MATERIAL AS SHOP PAINT.
1. INFORM THE ARCHITECT/ENGINEER OF OTHER MISCELLANOUES CONCRETE STRUCTURAL ELEMENTS NOT SHOWN ABOVE TO
10.COMPLY WITH AISC CODE AND SPECIFICATIONS FOR BEARING, ADEQUACY OF TEMPORARY CONNECTION AND
DETERMINE THEIR COMPREHENSIVE STRENGTHS.
ALIGNMENTS.
2. ALL CONCRETE WORK SHALL CONFIRM TO THE LATEST EDITION CODE OF THE AMERICAN CONCRETE INSTITUTE (ACI 318-01)
11.CONTRACTOR SHALL FURNISH COMPLETE ERECTION DRAWINGS FOR THE PROPER IDENTIFICATION AND ASSEMBLY OF
3. LOCATION OF ALL CONSTRUCTION OR COLD JOINTS MUST BE APPROVED BY THE ARCHITECT/ENGINEER.
THE DRAWINGS WILL SHOW ANCHOR BOLTS SETTINGS, PRIMARY, SECONDARY AND ROOF FRAMING, AND NECESSARY
4. PIPES OR DUCTS EXCEEDING ONE THIRD THE SLAB OR WALL THICKNESS SHALL NOT BE PLACED IN STRUCTURAL CONCRETE
INSTALLATION DETAILS. SUBMIT SHOP DRAWINGS FOR APPROVAL BEFORE APPLICATION.
UNLESS SPECIFICALLY DETAILED. PIPES MAY PASS THROUGH STRUCTURAL CONCRETE IN SLEEVES BUT SHALL NOT BE
EMBEDDED THEREIN.
+507,270
5. REINFORCING BARS, ANCHOR BOLTS, AND OTHER INSERTS SHALL BESECURED IN PLACE BEFORE POURING CONCRETE BARS
PLACEMENT AND SUPPORTS SHALL BE IN ACCORDANCE WITH THE RECOMMENDED ACI PRACTICE.
E. FORMWORKS MUSEUM LEVEL 1
6. IN GENERAL, THE LATEST EDITION OF (MANUAL OF STANDARD PRACTICE FOR DETAILING CONCRETE STRUCTURES) ACTS 315,
SHALL BE ADHERED TO, UNLESS SHOWN OTHERWISE. 1. FORMS SHALL BE PROVIDED FOR ALL CONCRETE INDICATED UNLESS
7. USE OF ADMIXTURES IS PERMITTED TO PRODUCE PROPER SLUMP AND WORKABILITY BUT SUBJECT TO THE ENGINNER'S SPECIFIED OTHERWISE. FORMS SHALL BE SET TRUE TO LINE AND GRADE
APPROVAL, ADDITION OF WATER TO CONCRETE AT JOBSITE IS NOT ALLOWED. AND MAINTAINED SO AS TO INSURE COMPLETED WORK WITH THE ITEMS REMOVAL DAYS
ALLOWABLE TOLERANCES SPECIFIED AND SHALL BE MORTAR TIGHT.
2. FORMS AND THEIR SUPPORTS SHALL BE DESIGNED SO AS NOT TO FOUNDATION 24 HRS.
C. REINFORCING STEEL DAMAGE PREVIOUSLY PLACED STRUCTURE. SUSPENDED SLAB EXCEPT
3. NO CONSTRUCTED LOAD SHALL BE SUPPORTED ON, NOR ANY SHORING WHEN ADDITIONAL LOADS 14 DAYS
SCHEDULE OF REINFORCING BARS REMOVED FROM ANY PART OF STRUCTURE UNDER CONSTRUCTION ARE IMPAIRED
EXCEPT WHEN THAT PORTION OF THE STRUCTURE IN COMBINATION WIH
DIA. OF BARS GRADE (fY) ASTM THE REMAINING FORMING AND SHORING SYSTEM HAS SUFFICIENT COLUMNS / WALLS 2 DAYS
2
DIA. 20 AND SMALLER GRADE 40 (40,000 psi.) A615/A615M (DEFORMED) IMPOSED LOADS. BEAMS 14 DAYS
4. FORMS SHALL BE REMOVED IN SUCH MANNERS SO AS NOT TO IMPAIR
DIA. 25 AND LARGER GRADE 40 (40,000 psi.) A615/A615M (DEFORMED) SAFETY AND SERVICE ABILITY OF THE STRUCTURE
5. SCHEDULE OF STRIPPING OF FORMS AND SHORES.
S103 1 : 60
1 STRUCTURAL NOTES
S103 NTS
450
COLUMN SCHEDULE
300 200
Type STR@50mm STR@100mm STR@150mm STR@200mm STR@250mm STR REST AT STR Size B H RSB12mm RSB16mm RSB20mm RSB25mm
450
300
200
COLUMN SCHEDULE
RC1 450 x450 4 3 0 0 0 200 12 mm 450 450 0 8
3 RC2 450 x 450 4 3 0 0 0 200 12 mm 450 450 0 8
S103 1 : 30 300
200
490
BEAM SCHEDULE
350
Type STR@50mm STR@100mm STR@150mm STR@200mm STR@250mm STR REST AT B H STR Size RSB12mm RSB16mm RSB20mm RSB25mm
300 SUPPORT MIDSPAN
300 300
B4
B1 300 x 500 1 0 4 4 0 250 300 500 12 mm 0 6
1,000
200
B2 200 x 1000 1 6 4 4 0 250 200 1,000 12 mm 8
750
600
500
500
S103 1 : 30
PROJECT NO. PROJECT TITLE DATE REVISION DESCRIPTION OWNER SHEET CONTENTS SHEET NUMBER
13/11/2012 08:06:28
CHECKED BY LOCATION
UNIVERSITY OF THE S103
PHILIPPINES BAGUIO
PRC NO: TIN NO: PRC NO: TIN NO:
PTR NO: DATE: PTR NO: DATE: Checker Enter address here SCALE : As indicated @ A1
PLACE: PLACE:
THIS DOCUMENT IS THE COPYRIGHT OF 90 DESIGN STUDIO. ALL DIMENSIONS AND SITE CONDITIONS TO BE VERIFIED ON SITE PRIOR TO COMMENCEMENT OF ANY WORK OR PREPARATION OF SHOP DRAWINGS AND/OR THE
FABRICATION OF ANY COMPONENTS. SHOULD THERE BE ANY DISCREPANCIES REFER TO ARCHITECT PRIOR TO COMMENCEMENT OF THE WORK. DO NOT SCALE DRAWINGS - REFER TO FIGURED DIMENSIONS ONLY. DRAWINGS TO BE
READ IN CONJUNCTION WITH RELEVENT DOCUMENTATION FROM ENGINEER AND OTHER SPECIALIST SUB CONSULTANTS. THIS DOCUMENT DESCRIBES THE DESIGN INTENT, DESIGN DETAILS AND / OR FINISHES, SIZES AND
RELATIONSHIPS OF ROOMS, BUILDING ENVELOPE AND ARCHITECTURAL EXPRESSION.
FOUNDATION SCHEDULE
Type Volume Width Length Rebar L Rebar W Area LxW
FLOOR SCHEDULE
Type Type Mark Level Area Volume Rebar Spacing H Rebar Spacing W
L/4 L/4
L/5 L/5
B B
TOP BARS
STIRRUPS
A
BOTTOM BARS
3,000
SECTION A SECTION B
450 450 A B
BEAM SECTION
4@100mm, REST @ 200 mm REST @ 200 mm
NAT. GRD. LN NAT. GRD. LN 2
S105 1 : 20
VERIFY
VERIFY
1500
1500
300
2,000 3000
CC1 - F1 RC1 - WF
1 FOUNDATION DETAILS
S105 1 : 40
PROJECT NO. PROJECT TITLE DATE REVISION DESCRIPTION OWNER SHEET CONTENTS SHEET NUMBER
13/11/2012 08:06:28
CHECKED BY
KORDILYERA
LOCATION S105
PRC NO: TIN NO: PRC NO: TIN NO:
PTR NO: DATE: PTR NO: DATE: Checker GOVERNMENT CENTER ROAD, BAGUIO CITY
PLACE: PLACE:
13/11/2012 08:06:28 SCALE : As indicated @ A1
THIS DOCUMENT IS THE COPYRIGHT OF 90 DESIGN STUDIO. ALL DIMENSIONS AND SITE CONDITIONS TO BE VERIFIED ON SITE PRIOR TO COMMENCEMENT OF ANY WORK OR PREPARATION OF SHOP DRAWINGS AND/OR THE FABRICATION OF ANY
COMPONENTS. SHOULD THERE BE ANY DISCREPANCIES REFER TO ARCHITECT PRIOR TO COMMENCEMENT OF THE WORK. DO NOT SCALE DRAWINGS - REFER TO FIGURED DIMENSIONS ONLY. DRAWINGS TO BE READ IN CONJUNCTION WITH RELEVENT
DOCUMENTATION FROM ENGINEER AND OTHER SPECIALIST SUB CONSULTANTS. THIS DOCUMENT DESCRIBES THE DESIGN INTENT, DESIGN DETAILS AND / OR FINISHES, SIZES AND RELATIONSHIPS OF ROOMS, BUILDING ENVELOPE AND ARCHITECTURAL
EXPRESSION.