You are on page 1of 2

TDB x09 TERR.

- TV - DEMODULATOR
ATV (AM) ® A/V

Device variants
BLINE TDB 109 9251.01 VHF I ® A/V
TDB 209 9252.01 VHF II ® A/V
TV - RF
IN
TV - HF - Input TDB 309 9253.01 VHF III ® A/V
TDB 409 9254.01 UHF IV/V ® A/V

TERR. - TV DEMODULATOR
ATV (AM) ® A/V
MODEL: TDB 109 ART.-No.:9251.01
-
TV-RF IN 47 ... 72 MHz
INPUT LEVEL 950 … 2150 MHz
VIDEO OUT 1 Vpp
AUDIO OUT 1,5 Veff
TV-STANDARDS B/G, D/K, I, L, M
SUPPLY CURRENT 0,3 A

Operating voltage General


Control bus The terrestrial TV - demodulators TDB x09 are modules of the headend system
X1 X2

LED “STANDBY” (red) B-LINE which is conceived as a complete system for middle sized networks.
STANDBY

READY
LED “READY” (green) The modules convert analogue terr. TV-signals into A/V - signals.
ADDR.
All modules will be programmed and controlled via a central control unit and are
LED “ADDR.” (Yellow) working fully independently afterwards.
Address selection switch
The status of each individual module will be displayed via a colored LED.
VIDEO
OUT Video - Ouput
· Red - STANDBY Standby mode
AUDIO
OUT
Audio - Output · Green - READY Operating status
· Yellow - ADDR. Remote control mode

Bild 01
Function description
The terr. TV-demodulator is equiped with a ajdustable filter for the terr. partial frequency range at the input (4 input variants)

The noise storage of the input device enables a direct processing of the antenna signals.
The constance of the output-level via a wide input voltage range will be granted through a two stage level control with delayed
HF - control core.

After IF - filtration the demodulation in Audio and Video takes place.

Additional functions: Remote supply pre-amplifier (Fig. 4)

Software HCB 100: 9650.01 / 9650.02 from V 1.48


9650.03 from V 2.10

PROGRAMING Adjustment with the head end controller


· Adjustment of the addresses at the bus extender BEB 100 and at the
modules
· Activation of the programming mode of each module by selecting the
line (BEB 100) and the module position (01... 15) at the head end
controller(HCB 100)
® yellow LED will be lit up til the beginning of the parameter
adjustment
Start - TDB x09 · Adjustment of the UCB 1x6 parameter(see fig.02)
Program name ® green LED is lit up
· After the programming the UCB 1x6 will be automatically switched into
TV - Input the operating status
Frequency 47000 … 75000 kHz ® yellow LED lights up briefly / green LED is lit up
75000 … 100000 kHz
174000 … 230000 kHz
470000 … 862000 kHz
Adjustment with the PC / Laptop
TV - Standard B/G; D/K; M; N; I; L
Audio Mode Mono, Stereo, Dual · Condition for the remote programming is an “online - connection”
Audio Level +3dB ..... -20dB after IP - standard and an ethernet connection at the PC / Laptop
Video Level +10 ..... -5% · Adjustment of the line / position addresses at the bus extender BEB
Videofilter Ein/ Aus
100 as well as at the modules
Device status · At the head end controller HCB 100 IP - address input
(e.g. 192.168.001.001)
End - TDB x09 · For “direct connection” between a PC and HCB 100 use a crossed
patch cable (RJ 45)
· For connection over a deviation use an uncrossed patch cable
· HTML - browser start-up and put in IP - address as target address
· If connected correctly the HTML - control surface at the PC will open up
and a green LED (LINK) at the HCB 100 will be lit up
· All adjustment of the modules are specified at the control surface

a green LED (LINK) at the HCB 100 will be lit up

Fig. 02
The manual instructions of the head end controller HCB 100 and the bus extender BEB 100 have to be considered!
TECHNICAL DATAS
TV - INPUT Operating parameter
Frequency range Voltage / Current 12 V ( ±0,2 V ) / 250 mA
VHF I 47 ... 75 Mhz Residual ripple of
VHF II 75 ... 100 MHz Supply voltage £10 mVss
VHF III 174 ... 230 MHz
UHF iV ... V 470 ... 862 MHz Environmental conditions
Tunig grid 31,25 kHz Temperature range -10 ... +55 °C
AGC - Level range 52 ... 90 dBµV Relative humidity £80 % (not condens.)
Impedance 75 W Mounting method vertically
Nominal input level 72 dBµV Mounting location squirting- and dripping
Connectors F - Socket water protected
Noise storage £10 dB (dry environment)
TV - Norm/Standard B/G; D/K; M; N; I; L
Preamplifier-remote supply 12 V / 400 mA
Additional
(pluggable)
Dimesions (L x H x W)
without 19“ - Adapter 50 x 276 x 148 mm
Video - OUTPUT
With 19” - Adapter 50 x 301 x 148 mm
Output voltage 1 Vss
Weight 1.215 g
Impedance 75 W
Connector BNC - Socket
Delivery content
Audio - OUTPUT 1 x Bus connector
Level (at 600 W) 6 dBm (= 1,55 Veff) 1 x Audio - control cable ASK 525
Output resistance £30 W 1 x Video - connection cable VVK 526
Connector Socket in accordance to
DIN 45326 /I EC 130 - 9 - 20

HEAD END BUS STRUCTURE Additional functions


Remote supply of a pre-amplifier
ADDR. 01

ADDR. 01

ADDR. 15
BEB 100
HCB 100

Module

Module

HCB 100 OFF ON


Head end
controller
VV: +12 V
ST 1
ADDR. 01
ADDR. 02

ADDR. 15
BEB 100

Module

Module

With a view to remote supply of a pre-amplifier without own supply


BEB 100 the 12 V operating voltage of the converter can be put to the TV - RF
Bus extender - input sockets.
After opening the cover (left cover) the jumber bridge at the tuner-
circuit board (”W: +12V” /St1) has to be plugged to position “ON”.
Fig. 04
Module
ADDR. 01
ADDR. 15

ADDR. 15
BEB 100

Module

Module

Reception unit Allocation Audio - socket


8 1 Stereo Left
7 6 2 Screenting / Earth - Mass
7
8
6 3 Stereo Right
3 3 1
1 4 Earth-Mass Left
5
2
4
5 Earth-Mass Right
The number of the possible module connections (00 ... 15) to a BEB 6 Control line contact 1(jumbered with Pin 8)
5 4 7 Control line contact 2 (open)
100 depends on the total power consumption of this line! 2 8 Control line return wire (Earth - Mass)
Fig. 03 Fig. 05
SECURITY AND OPERATING INSTRUCTIONS
When assembling, starting-up and adjusting the modules, it is necessary to consider the system specific references in the
manual instruction!

The modules may only be installed and started up by authorized technical personnel!

When assembling the modules into the receiving points, the adherence of the EMV regulations is to be secured!

The assembly and wiring have to be done without voltage!

All active modules may only be operated with the head end controller HCB 100 or bus extender BEB 100!

The main voltage for all power supply units is 230 V, 50 Hz.

With all work the defaults of the DIN EN 50083 have to be considered!
Especially the safety relevant execution of the DIN EN 50083/1 is necessary!

Options and other TV standards available upon request!


Version 01 Part- N° 925x.01

BLANKOM Antennentechnik GmbH


Hermann - Petersilge - Str. 1 · 07422 Bad Blankenburg · Germany · Phone +49 (0) 36741/ 60-0 · Fax +49 (0) 36741/ 60-100