Professional Documents
Culture Documents
An A1 event is triggered when the serving cell becomes better than threshold. The threshold is set in the
eNB.
A2 Event:
An A2 event is triggered when the serving cell becomes worse than threshold. The threshold is set in the
eNB.
A3 Event:
An A3 event is triggered when the Neighbour cell becomes offset better than serving cell. The offset is
set in the eNB. This applied to intra frequency measurements.
A4 Event:
An A4 event is triggered when the Neighbour cell becomes offset better than threshold. The threshold
and offset is set in the eNB.
A5 Event:
An A5 event is triggered when serving cell becomes worse than threshold1 and neighbour cell becomes
better than threshold2. Both these thresholds are set in the eNB.
A6 Event:
An A6 event is triggered when neighbour SCell becomes offset better than serving SCell. The offset is set
in the eNB.
B1 Event:
A B1 event is triggered when an Inter RAT neighbour becomes better than threshold.
B2 Event:
A B2 event is triggered when serving cell becomes worse than threshold1 and inter RAT neighbour
becomes better than threshold2.