Professional Documents
Culture Documents
“enduring protection”
introduction
SolaHD understands that your operations depend on clean, continuous power. That’s why, since
1915, SolaHD has focused exclusively on being the premier brand for industrial power quality by
eliminating the power interruptions, transients and noise that can stop production and corrupt data.
Our full breadth of products convert, clean and maintain electric current from the factory entrance
to equipment throughout your facility. Combined with service and support, our total power quality
offering can save you time, money and space to ensure optimal production efficiencies.
Introduction 2
Product Overview 4
SURGE PROTECTION
STV 200/400K Series 7
STFV Plus Series Active Tracking Filters with Surge Protection (Chassis Mount) 17
STFE Elite Series Active Tracking Filters with Surge Protection (DIN Mount) 20
2
HOW DO YOU PROTECT YOUR POWER?
Employing an entire facility protection strategy will safeguard the electrical system against most transients. Multi-stage protection
involves clamping the initial high energy surge, filtering any remaining noise or transients to the protected sensitive equipment and
finally, protecting the data/signal lines entering or leaving the control panel or the factory floor. This coordination of devices provides
the lowest possible let through voltage to the equipment.
STC-PoE
Ethernet Surge STC-DRS
Protective Device DIN mounted
Surge Protective
Device For Data
Signals
D
STS-DRS-060
4
5
STC-CCTV
6
E
OK
LINE
Surge Protective
LINE
C
SHIELD
Device For Coaxial
1
2
3
B
STF Elite
Act
(located behind server) STFive Trac Active Tracking C
A
B
Elit king
e S Filt
erie er Filter With L
E
s Surge Protection ST
C-C
CTV E
-751 Q
ssor U
ppre I
e Su ries Solatron Plus P
Surg 00k Se
STV1 Three Phase
F
E2
LIN
Surge Suppressor
Device (SPD)
r
Suppresso
Surge Series 2
STV100k LINE
1
LINE
SERVICE
STS-DRS-060
4
5
6
LINE
LINE
SHIELD
1
2
3
OK
Active
STF Tracking
Elite
SeriesFilter
K-Factor
Harmonic
Transformer
1
LINE
SERVICE
MCR Series
Constant Voltage
Power Conditioner
LVGP
Transformer
STV 200/400K
Service Entrance
G
Surge Protective Device
L
L1
N
L2
LOA G
e D
Devic
G
A
tective s Stat
Pro Serie
us OK
Surge00/400K
STV2 REDUCEDON
ECTI
s Se er
ALAR
M
ries
L
LIN
L1 E
N
L2
G
G
D S
TC-DRS: DIN Rail mountable, single pair, low voltage data,
surge protective devices. The hybrid design of these data/
signal line protective devices allows them to respond quickly.
3
surge protection, filtering, data/signal line protection
Active Tracking Filtering with Surge protection • Provides Clean AC Power by Eliminating Low-Voltage Noise
Facility Service
Entrance
Distribution Panels
Sub-Distribution
Panels
Branch Panelboards
(Commercial)
Branch Panelboards
(Residential)
Motor Control
Centers
Programmable
Logic Controllers
Control Panels
(AC Power)
Various OEM
Equipment
Transmitters
PoE
(Power-over-Ethernet)
Industrial
Communications
Programmable
Logic Controllers
(I/O Circuits)
Control Panels
(Low Voltage)
Water/Wastewater
Instrumentation
Underwriters Laboratories (UL) Standard for Safety, Transient Voltage Surge Suppressors (UL 1449) has undergone a number of changes
and will continue to drive application changes throughout the industry. This includes a change in nomenclature from transient voltage surge
suppressors (TVSS) to surge protective devices (SPD) and recognition of the standard by the American National Standard Institute (ANSI).
The adoption of the third edition of UL 1449 also affects performance testing methodologies, SPD ratings and the appropriate application
of SPDs.
Prior versions of the standard did not take into account the performance of the protector. So many products have entered the market that
essentially provided no benefit, but were ‘safe for use’. To address this, UL under took these major changes and introduced a 2nd edition
to the standard. Once the new standard was put into practice, it became clear there were still some more issues that needed to be addressed,
therefore, UL decided to make further changes in the form of a 3rd edition to UL 1449.
UL now categorizes surge protective devices (SPD) into categories based on its
intended application.
• TYPE 1 - Connect anywhere in the customer’s facility –
we strongly urge this to be specified for all critical installations.
• TYPE 2 - Connect downstream on load side of main breaker.
Be aware that some competitors may have “conditions of acceptability”
that can limit how the device is installed.
• TYPE 3 - Typically cord connected, plug in devices.
• TYPE 4 - Components
IEEE Standard 1100-2005, The Emerald Book: IEEE Recommended Practice for Powering and Grounding Electronic Equipment
recommends a tiered SPD protection from your Service Entrance down to branch panel level.
7.2.4 Surge suppressors: “…Effective surge protection for an entire building power distribution system requires the coordinated use of
large-capacity current-diverting devices at the service entrance followed by lower capacity voltage-clamping devices applied strategically
throughout the power system.”
6
STV 200/400K series
These devices are built to meet your unique requirements, and are
available in hardwire, three phase configuration. They are designed •• Custom options (contact technical support)
for years of trouble free operation and require little or no operator - NEMA 12 enclosure, NEMA 3R, 4, and 4X
intervention after installation.
- Optional rotary disconnect, transient counter and remote
monitor panel
Applications
The STV 200/400K Series can be a facility-wide product family
and may be installed from service entrances to distribution panels
to branch panels.
Selection Table
• Industrial Plants
Catalog Input
• Commercial Buildings Number Voltage
• Institutional Facilities
STV 400K-10Y 120/208 V Three-Phase Wye, 4-Wire + Ground
• Any facility that has an environment with electronics based
equipment STV 200K-10Y 208 Y/120 V Three-Phase Wye, 4-Wire + Ground
•• UL 1449 3rd Edition, Type 1, 20kA I-nominal approved STV 200K-48D 480 V Three-Phase ∆, 3-Wire + Ground
device
•• Industry’s highest surge current repeatability
•• All modes transient protection (L-N, L-G, and N-G)
•• Form C dry contacts and audible alarm status indications
•• Internal/external monitoring, including neutral to ground
•• EMI/RFI Filtering
•• Five year limited warranty
S u r ge p r o t ect io n
STV 200/400K series
Specifications
Catalog Number
Parameters
STV200K-10Y STV200K-27Y STV200K-48D STV400K-10Y STV400K-27Y STV400K-48D
208 Y/120 V 480 Y/277 V 480 V 208 Y/120 V 480 Y/277 V 480 V
Input Voltage 3Ph Wye, 3Ph Wye, 3Ph Delta, 3Ph Wye, 3Ph Wye, 3Ph Delta,
4W+G 4W+G 3W+G 4W+G 4W+G 3W+G
Maximum Continuous
125% of the nominal level for 120 V; 115% for all other voltages
Operating Voltage (MCOV)
Line Frequency 47–63 Hz
Response Time < 0.5 ns
Enclosure Metal, UL Listed /NEMA type 12 (3R, 4, 4X also available)
Mounting Type Wall Mounted (mounting hardware ¼ in.)
Connection Internally connected
Status Indication Red and green LED status indicators, audible alarm, summary alarm contacts
Operating Temperature -40°C to +50°C
Operating Humidity 0% to 95% non-condensing
Noise Attenuation 50 dB maximum
Modes of Protection All Modes: L–N, L–L, L–G, N–G *
AIC Rating 200 kAIC
Nominal Discharge Current
20 kA
Rating (In)
Warranty 5 year limited warranty
UL 1449, 3 Edition, Type 1 Voltage Protection Ratings (VPRs)
rd
Surg e p rotecti on
STV 200/400K series
Dimensional Drawings
Phase L1/A
Phase L2/B
12.00 0.31 8.25 Service Panel for Phase L3/C
Loads to be Protected
(304.8) (7.9) (209.6) Disconnect/Main
Breaker for
Panel
Dedicated Neutral Bus
Disconnect
(Optional) Ground Bus
Recommended Wire
Entrance
(425.5)
(412.8)
16.75
16.25
1 2 3 1 2 3
TB1 TB2
14.25 1.30 max.
(362.0) (33.0)
Dimensional Specifications
STV 200/400K Series
Allowable
WEIGHT DIMENSIONS Suggested Suggested Wire Allowable
Catalog Number WIRE
LBS (KG) D x W x H (IN.) Breaker Size Size (AWG) Breaker Range
Range
STV200K 35 (15.88) 8.25 x 14.25 x 16.25 40 A #8 15–100 A #14–2
STV400K 42 (19.05) 8.25 x 14.25 x 16.25 100 A #2 15–100 A #14–2
S u r ge p r o t ect io n
STV 100K Series
Applications
• Distribution Panels (<1200 A)
• Branch, Lighting and Control Panels
• Factory Automation Installations
• Dedicated Industrial Equipment
Features
• 100,000 amp peak current rating provides all mode
protection against severe transients E324279
STV 100K-48D 480 V Three Phase, ∆ 3-Wire + Ground Figure 1: Mechanical Dimensions 0.50 2.00
Unit shown is a three-phase wye (12.7) (50.8)
10
Surg e p rotecti on
STV 100K Series
Specifications
Catalog Number
Description
STV 100K-10S STV 100K-10N STV 100K-24L STV 100K-10Y STV 100K-23Y STV 100K-27Y STV 100K-24D STV 100K-48D STV 100K-10D4 STV 100K-24D4
Nominal Input Vac 120/240 V 120 V 240 V 208 Y/120 V 400 Y/230 V 480 Y/277 V 240 V 480 V 240 D/120 V 480 D/240 V
System Single Phase Single Phase Three Phase Wye Three Phase Delta Three Phase Delta High Leg
Configuration 3 wire + Ground 2 wire + Ground 4 wire + Ground 3 wire + Ground 4 wire + Ground
Maximum
Continuous
125% of the nominal level for 120 V; 115% for all other voltages
Operating Voltage
(MCOV)
Line Frequency 47-63 Hz
Response Time < 0.5 nsec
Nominal Discharge
3 kA
Current Rating
Modes of
All Mode: L- N, L - L, L - G, N - G
Protection
Operating
-40°C to +60°C
Temperature
Dimensions -
6.00 in. x 4.00 in. x 3.20 in. (152.4 mm x 101.6 mm x 81.3 mm)
W x D x H - in. (mm)
Connection/
Parallel/Flange
Mounting Type
Status Indication Red and green LED status indicators, audible alarm, Form C contacts
High Leg to Ground N/A N/A N/A N/A N/A N/A N/A N/A 1200 V 2000 V
Per Phase 100 kA 100 kA 100 kA 100 kA 100 kA 100 kA 100 kA 100 kA 100 kA 100 kA
Line to Ground 50 kA 50 kA 50 kA 50 kA 50 kA 50 kA 50 kA 50 kA 50 kA 50 kA
11
S u r ge p r o t ect io n
STV 25K DIN Rail Series
Dimensions
Features
2.56
• Compact and narrow design maximizes panel space. (65.0)
Selection Table
4.75 (120.7)
Catalog Number Input Voltage
12
Surg e p rotecti on
STV 25K DIN Rail Series
Specifications
Catalog Number
Description
STV 25K-10S STV 25K-24S
Input Voltage 120 Vac, Single Phase 0-135 Vrms 240 Vac, Single Phase 0-260 Vrms
Maximum Continuous
120 - 150 Vrms 240 - 275 Vrms
Operating Voltage (MCOV)
Line Frequency 47-63 Hz
DIN Rail Mount (Chassis Mount Bracket Optional order
Connection/Mounting Type
SDN-PMBRK2) with screw terminals for #12 AWG.
Input Current Rating 20 Amps
Phase Configuration 2 wire + GND
Weight - lbs (kg) 3.0 lbs (1.36 kg)
4.87 x 2.56 x 4.75 (123.7 x 65.0 x 120.7)
Dimensions H x W x D - in (mm)
includes mounting bracket
Modes of Protection All Mode: L - N, L - L, L - G, N-G
Status Indication Green LED, Form C Contacts
13
S u r ge p r o t ect io n
STF Series
Applications
• Branch and Control Panels
• Factory Automation Installations
• Point of Use Industrial Service Equipment
• Dedicated Industrial and Machine Tools Equipment
• Telecommunications Equipment
14
Selection Table
Catalog Min. Wire Size Fuse/Circuit Breaker Ampacity Case Dim. Mounting Flange Dim. Weight Design
Amps
Number (AWG Suggested) Suggest Max in (mm) - A x B x C in (mm) - D x E x F lbs (kg) Style
15
Specifications
Description 120/208 Vac Models 277/480 Vac Models 480 Vac Models
Input Voltage 0-150/240 Vrms 0-320/520 Vrms 0-520 Vrms
Line Frequency 50/60 Hz
Transient Attenuation Response
Instantaneous
Time
Mean Time Between Failure (MTBF) > 100,000 Hours (Mil Std. 217F)
Single phase < 30 Amps housed in black, high impact plastic case,
vacuum impregnated magnetics, epoxy encapsulated.
Packaging
Single phase > 30 Amps, 480 Vac,
and three phase units housed in NEMA 12 enclosures.
Operating Temperature -40°C to +45°C; Derate Linearly to 60% at +70ºC
10m sec: 5 x Nominal
Load Surge Current Rating 1 sec : 3 x Nominal
5 sec: 2 x Nominal
Minimum of 40dB from 50 kHz through 50 MHz. Attenuation is greater than 50 dB to the surge withstand
Transient Reduction capability Ringwave test IEEE C62.41, Category “A” (IEEE Category A Ringwave 6 kV, 200A, 100 kHz)
and “B” (IEEE Category B Ringwave 6 kV, 500 A, 100 kHz).
Warranty 10 year limited warranty
Dimensional Drawings
Design Style 2
16 Design Style 4
Applications
• Branch and Control Panels
• Factory Automation Installations
• Point of Use Industrial Service Equipment
• Programmable Logic Controllers
• Dedicated Industrial and Machine Tools
• Telecommunications and IT Equipment
Features
• Non degrading, series filter/TVSS technology
for total durability
• UL surge current capacity – 25,000 amps
• High impact plastic case, epoxy encapsulated enclosure
• Transient protection in all modes (L-N, L-G, and N-G)
• Single phase applications up to 30 amp
• Operating temperature from -40°C to +60°C
• Hardwired connection
• LED power indication
• Ten year limited warranty
17
Selection Table
Mo
Di unti Pulse Capacitor
me ng
nsi high-frequency noise absorption
on
s
18
Specifications
Description Value
19
Features
•• Series connected DIN Rail mounted filter
•• Durable metal mount clip
•• UL Listed surge current capacity – 45,000 Amps
•• Transient protection in all modes (L-N, L-G, and N-G)
•• Single phase applications up to 20 Amp
•• Operating temperature from -40°C to +50°C
•• Screw terminal connections
- Reliable and convenient screw clamp connections
- Accept 10-16 AWG wire
- Meet IP20 specifications for ingress protection
The SolaHD STF Elite DIN Rail Mount Series combines • LED status indication
Active Tracking® technology with UL Listed surge
protection to protect against the full spectrum of voltage •• Form C contact for remote monitoring
transients and surges. It continuously tracks the input AC •• Five year limited warranty
power line responding instantly into action upon detecting
extraneous high frequency noise and high voltage transients
caused by everyday events such as turning on machinery,
motors, or equipment.
They are built to meet your unique requirements, and STFE100-10N 120 V Single Phase, 2 Wire + Ground
are available in hardwired DIN Rail mount, single phase
configuration. They are designed for years of trouble free STFE200-10N 120 V Single Phase, 2 Wire + Ground
operation and require little or no operator intervention after STFE030-24L 240 V Single Phase, 2 Wire + Ground
installation.
STFE050-24L 240 V Single Phase, 2 Wire + Ground
20
Specifications
To load or
N/L2 N/L2 equipment
N/L2 N/L2
protect
Relay
GND Contacts GND
GND GND
NO COM NC
To remote indication
if needed
21
Series Application
22
Specifications
Description STC-P0E-65FF STC-CAT6-PoE-I
Normal Mode (L-L) All Lines (1-8) Protected (L-L) and (L-G)
Mode of Protection
All Lines (1-8) Protected Signal High-Low; High-Ground; Low-Ground
DC Breakover Voltage 60 Vdc
Insertion Loss < .1 dB
Certified Transmission Speeds 10baseT, 100baseT, 1000baseT
Peak Surge Energy 300 Watt 750 Watt
Response Time <1 ns
Connectors RJ-45 (Female - Female)
Dimensions - in (mm) 2.30 x 1.00 x .80 (58.4 x 25.4 x 20.3) 5.40 x 1.60 x 1.70 (137.2 x 40.7 x 43.2)
Warranty 3 year limited warranty 5 year limited warranty
23
Features
• Low-Voltage data surge protection
• Three-Stage hybrid technology
• Sneak/Fault current protection with
resetable fuses (PTCs)
• Low profile packaging
• Easy installation
• Fits standard 35 mm DIN Rail
• Fast response time <1 nanosecond Notes:
These protectors are intended for indoor use on communication loop
• Five year limited warranty circuits that have been isolated from the Public Switch Telephone Network.
The communication loop circuits shall not be exposed to accidental contact with
the electric light or power conductors. The protectors shall be installed per the
applicable requirements of the National Electric Code, ANSI/NFPA 70.
Selection Table
24
• Intended for indoor use on communication loop STC-FM4-DRC Optional DIN Rail Mounting Clip for STC-PCB1B
circuits which have been isolated from the Public
Switch Telephone Network.
• RS232 applications used with STC642-020 and
Specifications
STC-PCB1B
Description STC642-020* STC642-036*
• 4-20 ma signal applications used with STC642-
036 and STC-PCB1B Peak Surge Current 8x20 s .. 10kA
(10 times) 10x700 s 500A per line
• For use in service capable of supplying less than
8x20 s (2000A) .. >100 occurrences
150 milliamperes continuously. Life Expectancy
10x700 s (400A)
Response Time <1ns
Features
Voltage Clamp 20 36
• Lightning protection for low voltage data
Technology SAD Hybrid
• Signal lines
Resistance 5 (typical)
• Three-stage protection
• Sneak/fault current protection Capacitance (typical) 1500pf
25
2.16 2.41
(55.0) (61.2)
Ground Terminal 1 or 10 (internally tied together) to building approved ground. The STC-PCB1B accommodates 24 to 10 AWG wire.
0.12 (3.0)
0.49 (12.4)
2.40
(61.0)
Top View
0.80 (20.3)
Side View
26
Specifications
Operating Voltage 5
Clamping Voltage 6
Equipment
IEEE Category C, and Category B
Location
The STC-CCTV Series is tailored specifically to CCTV, Primary Stage: Gas Tubes,
data, audio and cable applications. These units are STC Technology Secondary Stage: Silicon Avalanche Components
Third Stage: resetable fuses (PTCs)
single Coax Surge Protective Devices implementing
three-stage hybrid technology. They address overvoltage Modes of Protection Signal to Ground
transients with a primary gas tube, and secondary Nominal Discharge
silicon avalanche components. Over-currents (e.g. 10.0 kA
Current per Mode
sneak and fault currents) are mitigated with solid-state
Maximum
resetable fuses (PTCs). The STC-CCTV units are Discharge 20.0 kA
designed in accordance with NFPA 780 (2004 Edition) Current per Mode
requirements, with up to 20kA of surge current EMI Attenuation < 0.1 dB at 20 MHz
capability. The STC-CCTV-75I model has an isolated
VSWR < 1.2
ground and is recommended for use at the camera end.
Continuous Power 0.72 Watts
Applications Operating
0-95 % Non-condensing
• CCTV Head End Humidity
27
Appleton Grp LLC d/b/a Appleton Group. The Appleton, O-Z/Gedney, SolaHD, EasyHeat, Nelson and Emerson logos are registered in the U.S. Patent and Trademark Office.
EasyHeat, Inc. is a wholly owned subsidiary of Appleton Grp LLC. All other product or service names are the property of their registered owners. © 2014, Appleton Grp LLC. All rights reserved.