You are on page 1of 3

[AIRBUS Amber]

A320 FAMILY OPERATOR DIFFERENCE REQUIREMENT TABLES AND TASE REFERENCE J01D18012826
FLIGHT CREW
ODR Tables and TASE for MOD ISSUE 1 DATE : 16 March 2018

ODR Table and TASE – A319 CJ

Change title: A319 to A319 CJ.

Modification number: Nil.

Purpose: This ODR table provides the training/checking/currency requirements which must be fulfilled by flight crew in order to extend their privilege to operate from
the A319 variant to the A319 CJ (Corporate Jet version).

1. A319 CJ – General/Design
DIFFERENCE LEVELS

DESIGN DIFFERENCES FLT CHAR PROC CHG TRNG CHECK CUR

General The A319 CJ is a long range version of the A319 (6 300 nm). No No A A A
Cabin The maximum passenger capacity is 8 for maximum range operations. No No A A A
MTOW MLW
Limitations A319 64.4 T to 141 090 lb to 61.0 T to 134 480 lb to
No No A A A
Weight 76.5 T 168 853 lb 62.5 T 137 788 lb
A319 CJ 76.5 T 166 654 lb 62.5 T 137 788 lb
Limitations
There are specific center of gravity limitations for takeoff. No No A A A
Center of gravity
Limitations
The maximum altitude is 41 000 feet. No No A A A
Altitude

© AIRBUS S.A.S. 2021. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT. Page 1 of 3
[AIRBUS Amber]
A320 FAMILY OPERATOR DIFFERENCE REQUIREMENT TABLES AND TASE REFERENCE J01D18012826
FLIGHT CREW
ODR Tables and TASE for MOD ISSUE 1 DATE : 16 March 2018

2. A319 CJ – System (per ATA chapter)


DIFFERENCE LEVELS

SYSTEMS DIFFERENCES FLT CHAR PROC CHG TRNG CHECK CUR

21 – Pressurization
The pressurization flight profile is different.
Architecture No No A A A
The behavior of the safety valve is adapted to the maximum altitude.
Functions
There are from 1 to 6 ACT according to the customization (2 FWD and 4 AFT).
28 – Fuel
There is an additional Auxiliary Level Sense Control Unit (ALSCU).
Architecture No No B A A
There is an additional Auxiliary Fuel Management System (AFMS).
Functions
The fuel can be transferred manually in case of transfer failure.
28 – Fuel There is an additional fuel overhead panel for ACT transfer.
No No B A A
Controls and indications The ECAM page reflects the modifications.
52 – Doors
Architecture There is an additional airstair below the forward passenger door. No No A A A
Functions
52 – Doors
There is an additional airstair panel. No No A A A
Controls and indications

3. A319 CJ – Maneuvers – Normal Operations (per flight phase)


DIFFERENCE LEVELS

MANEUVERS NORMAL OPERATIONS DIFFERENCES FLT CHAR PROC CHG TRNG CHECK CUR

Descent There is an additional recommendation for descent initiation when cruising above FL 380. No No A A A

4. A319 CJ – Maneuvers – Abnormal Operations (per flight phase)


No difference in maneuvers/procedures in abnormal operations per flight phase.

© AIRBUS S.A.S. 2021. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT. Page 2 of 3
[AIRBUS Amber]
A320 FAMILY OPERATOR DIFFERENCE REQUIREMENT TABLES AND TASE REFERENCE J01D18012826
FLIGHT CREW
ODR Tables and TASE for MOD ISSUE 1 DATE : 16 March 2018

5. A319 CJ – Maneuvers – Abnormal Operations (per ATA chapter)


No difference in maneuvers/procedures in abnormal operations per ATA chapter.

6. A319 CJ – Training Areas of Special Emphasis (TASE)


No specific Training Areas of Special Emphasis.

© AIRBUS S.A.S. 2021. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT. Page 3 of 3