Twisted pair color code: When furnished as twisted pair, the following color code shall
apply:
Capacitance. The capacitance of a 50-foot twisted-pair sample, after first drying for 4 hours
at 30° C., and then followed by exposure for 24 hours to 30° C. and 90 per cent relative
humidity, shall not exceed 2500 micro-microfarads at 1000 cycles per second. When the
capacitance measurements are made, the sample shall be removed from the coil frame used
for humidification purposes, and tested either in a straight length or in such position as to
portion (such as might be introduced were adjacent loops to touch in a closely coiled
specimen).
Insulation resistance. The direct current insulation resistance (between conductor) of a 50-
foot twisted-pair sample, after exposure for 24 hours to conditions of 30° C. (86° F.) and 90
percent relative humidity, shall be not less than 1,000 megohms. The insulation resistance
measurements shall be made immediately following the capacitance measurements.
#22 Single Wire Telephone Code. Single conductors shall be furnished in the following
colors, as required: