You are on page 1of 9

INSPECTION REPORT

KPJB TANJUNG JATI UNIT 3 & 4 – JEPARA


Report No: 003–CVR-DT/Tj B U 3&4 – 12/NES- 2016

CERAMIC COATING ON VOLVO FM440

December 19, 2016

Reported by

Dian Indiarto
Technical Representative

For applicator
PT. STAHLINDO
ENGINEERING
INSPECTION REPORT
Form no.002 / NES /QC –TSR / 16

: DUMP TRUCK Rep.No 02/KPJB– 2016


Part of inspection
Date 13 Dec 2016
Project : TRIAL NOVAPLATE 325 ON FLOOR DUMP TRUCK
Costumers : PT. STAHLINDO ENGINEERING Area Internal Floor Dump
Truck
Client / owner : PT. KPJB TANJUNG JATI 3 & 4 JEPARA Sqm 22 m2

SURFACE PREPARATION ( CLEANED)


SSPC VIS Rust Grade : C Actual : -
Cleaning method : SSPC SP 3 Date & Time : 13/12/2016 & 10.00 PM
Re –Blast if necessary Date : Time : No require
NON DESTRUCTIVE PAINT TEST REFERENCES ( DFT –MEASUREMENT)
T
hickness NO YET CARRY OUT ( ON GOING )
SSPC PA 2 Measurement of Dry Film Coating Thickness with Magnetic Gages
PAINTING INFORMATION
Start date : 13 – 12 – 2016 Time : 10..00 PM
Product name /Code : NOVAPLATE 235 Batch No : XM0645 BF
Paint Consumption : Batch No :XM0325 UY
Thinner name /Code : Batch No : N/A
Thinner consumption : % consumption :
PAINTING APPLICATION
Application method : Tip Nozzle size :
Climatic Conditions Sunny Clear Rainy Fog W. Speed
Dry temperature : 260C - - x - N/A Knot/Hours
Wet temperature : 240C R.Humidity (RH) 78 % Dew Point :20 0
C
0
Steel Temperature : 20 C
NOMINAL DRY FILM THICKNESS ( DFT)
Measurement DFT –1
Reading In micron Average (
Product Name Area Comment
1 2 3 4 AVG)
NOVAPLATE 325 Internal

Total Nominal Dry Film Thickness


Measurement DFT – 2 Average (
Product Name Area Comment
1 2 3 4 AVG)
NOVAPLATE 325 Internal

Total Nominal Dry Film Thickness Not YET

Page 2 of 9
INSPECTION REPORT
Form no.002 / NES /QC –TSR / 16

: DUMP TRUCK Rep.No 02/KPJB– 2016


Part of inspection
Date 14 Dec 2016
Project : TRIAL NOVAPLATE 325 ON FLOOR DUMP TRUCK
Costumers : PT. STAHLINDO ENGINEERING Area Internal Floor Dump
Truck
Client / owner : PT. KPJB TANJUNG JATI 3 & 4 JEPARA Sqm 22 m2

SURFACE PREPARATION ( CLEANED)


SSPC VIS Rust Grade : C Actual : -
Cleaning method : SSPC SP 3 Date & Time : 14/12/2016 & 09.00 PM
Re –Blast if necessary Date : Time : 09.00 PM
NON DESTRUCTIVE PAINT TEST REFERENCES ( DFT –MEASUREMENT)
T
hickness NO YET CARRY OUT ( ON GOING )
SSPC PA 2 Measurement of Dry Film Coating Thickness with Magnetic Gages
PAINTING INFORMATION
Start date : 14 – 12 – 2016 Time : 09.00 PM
Product name /Code : NOVAPLATE 235 Batch No : XM0645 BF
Paint Consumption : Batch No :XM0325 UY
Thinner name /Code : Batch No : N/A
Thinner consumption : % consumption :
PAINTING APPLICATION
Application method : Tip Nozzle size :
Climatic Conditions Sunny Clear Rainy Fog W. Speed
Dry temperature : 290C - x - - N/A Knot/Hours
Wet temperature : 250C R.Humidity (RH) 78 % Dew Point :25 0
C
0
Steel Temperature : 29 C
NOMINAL DRY FILM THICKNESS ( DFT)
Measurement DFT –1
Reading In micron Average (
Product Name Area Comment
1 2 3 4 AVG)
NOVAPLATE 325 Floor With trowel

Total Nominal Dry Film Thickness


Measurement DFT – 2 Average (
Product Name Area Comment
1 2 3 4 AVG)
NOVAPLATE 325 Internal

Total Nominal Dry Film Thickness Not YET

Page 3 of 9
INSPECTION REPORT
Form no.002 / NES /QC –TSR / 16

: DUMP TRUCK Rep.No 02/KPJB– 2016


Part of inspection
Date 16 Dec 2016
Project : TRIAL NOVAPLATE 325 ON FLOOR DUMP TRUCK
Costumers : PT. STAHLINDO ENGINEERING Area Internal Floor Dump
Truck
Client / owner : PT. KPJB TANJUNG JATI 3 & 4 JEPARA Sqm 22 m2

SURFACE PREPARATION ( CLEANED)


SSPC VIS Rust Grade : C Actual : -
Cleaning method : SSPC SP 3 Date & Time : 16/12/2016 & 10.00 PM
Re –Blast if necessary Date : Time : 10.00 PM
NON DESTRUCTIVE PAINT TEST REFERENCES ( DFT –MEASUREMENT)
Thickness
NO YET CARRY OUT ( ON GOING )
SSPC PA 2 Measurement of Dry Film Coating Thickness with Magnetic Gages
PAINTING INFORMATION
Start date : 16 – 12 – 2016 Time : 10.00 PM
Product name /Code : NOVAPLATE 235 Batch No : XM0645 BF
Paint Consumption : Batch No :XM0325 UY
Thinner name /Code : Batch No : N/A
Thinner consumption : % consumption :
PAINTING APPLICATION
Application method : Tip Nozzle size :
Climatic Conditions Sunny Clear Rainy Fog W. Speed
Dry temperature : 300C - x - - N/A Knot/Hours
Wet temperature : 260C R.Humidity (RH) 78 % Dew Point :26 0
C
0
Steel Temperature : 30 C
NOMINAL DRY FILM THICKNESS ( DFT)
Measurement DFT –1
Reading In micron Average (
Product Name Area Comment
1 2 3 4 AVG)
NOVAPLATE 325 Floor 203 251 361 265 With trowel

Total Nominal Dry Film Thickness 265


Measurement DFT – 2 Average (
Product Name Area Comment
1 2 3 4 AVG)
NOVAPLATE 325 Internal

Total Nominal Dry Film Thickness Not YET

Page 4 of 9
Comment :

- Existing surface use Teflon


- During paint application all visual defect such as Run & sagging including if any found associated to
potential defect on the paint application has been repair according to paint manufacture recommendation.
- IF any defect while construction process shall repair with following the specification and /or according
paint specification.

Reported by Knowledge by Approved by

Dian Indiarto
Technical Service PT. PT. KPJB 3 & 4 PT. PLN
PT. National Energy STAHLINDO Tanjung Jati, Jepara
Solutions ENGINEERING

Page 5 of 9
Attachment

Existing condition of floor Dump Truck

Mixing process

Surface Preparation with SPPC SP3 or Power Tool

Page 6 of 9
Packing Novaplate 325 for Trial on Dump Truck

After application NOVAPLATE 325 with trowel

Page 7 of 9
Measurement of Dry Film Thickness (DFT)

Loading Dump Truck without Novaplate 325

Page 8 of 9
Loading Dump Truck with application Novaplate 325 on internal floor

-------------------------------- end of Report -------------------------