Signalling lamp circuit:

These lamps are provided to indicate the normal and abnormal working of
important equipment in the Loco. The signal lamps are controlled by signal relays.
Glowing of signal lamp indicates the abnormal condition of the apparatus and
extinguishing of lamp indicates the normal working of apparatus. The Pilot Lamp LSOL
and LS group are intended for MU operation of Locomotives. The circuit gets energised
if HBA is placed on ‗1‘ position and BL key is unlocked, provided fuse CCLS and
CCLSA are in good condition. The following Pilot Lamps are provided on the WAG-5
Locomotive.
1. LSDJ : It is Red in color and controlled by relay QV60.
2. LSCHBA : It is Green color and controlled by relay QCVAR & QV61
3. LSGR : It is Blue in color and controlled by relay QV62
4. LSRSI : It is White in color and controlled by relay QV63
5. LSB : It is Yellow in color and controlled by relay QV64
6. LSP : It is Red in color and controlled by relay Q48
7. LSAFR : It is Yellow in color and controlled by relay RGAF
8. LSOL : It is Amber in color and controlled by relay QVLSOL of other
Loco
9. LS group : It is Red in color and controlled by a group of SIGNALLING
relay inter-locks namely QV60, QV61, QV63 and QV64.
10. LSDBR : It is Red in color and controlled by relay QVRF.