Ÿ Power Quality;
Ÿ Electrical Protection;
Ÿ Lightning Protection;
Ÿ Industrial Electrical
T Technical Data
Power supply Working temperature range Electrical Life
AC / DC 85 - 265V -10 ° c to 55°C 1x 105
(other voltages available on request) Storage temperature range Mechanical Life
Operating frequency -20 °C to 65 °C 5 x10 5
50/60HZ Relative humidity (IEC 60068-2-30) Optional interface
Earth fault setting 95% at+ 40°C
RS485 to Modbus RTU/Slave
2.0 - 50.0% in step of 0.1% Protection Class (IEC 60529)
IP54 (optional with IP65 front cover) LED status indication
Overcurrent setting Normal operation, fault current detected
20_-200% in step of 1% Overcurrent withstand ability
Time multiplier setting 20 x lrated for 3 sec (100A for 0/C, 20A for E/F) Safety feature
Mechanical Trip Button
0.03 -2.00 in step of 0.01 (IEC, 1.3/10) Power consumption (MTB) complying with ANSI 86
0.3 :_20.0 in step of 0.1 (ANSI, IAC) <6VA
Definite time delay setting (DTL) Housing material
Relay Output ABS resin complying with UL94VO
0.03 - 2.00 sec in step of 0.01 sec 1 x C/0 (Changeover)
Instantaneous Mode (High Set) 1 x N/0 (Normally Open) Net weight
2.0 - 10.0 times setting Approx. 390g
Contact Rating
current in step of 0.1 current 5A at 250VAC
Pick-up current
100-115% of the setting
current in step of 1%
Reset current value
<90% of the operating value
IDMTL OVERCURRENT & EARTH FAULT RELAY IDMTL OVERCURRENT & EARTH FAULT RELAY
T MTB:
- Protrude out when relay triggered RELAY STATUS
Trip Reset
T Features
Microprocessor-based with highest accuracy
ROA207n
IDMTL Overcurrent Relay
- Mechanical Trip Button (MTB) fault indication system
- No reqwrement for auxiliary power supply for fault indication
- Safeguard against automatic reset before fault rectification
- Curve selection in accordance with ANSI, /AC, /EC, 1.3110, Hong Kong Ultilities Curve
• Normally Inverse (NI)
• Very Inverse (VI)
• Extremely Inverse (El)
• Short Time Inverse (ST/)
• Moderate Inverse (Ml)
- Trip value recording (4-memory)
- Date and time stamping for tripping
- Integrated surge arrester against transient overvoltages
- High set mode is incorporated tor instantaneous protection
- Tamper-proof design for settings protection
- Serial interface RS485 for Modbus RTU communication (optional)
- Type tested tor EMC compliance in acc. with /EC 61000
- High immunity to electrical interference (tested to 2.5GHz)
- Type tested in acc. with /EC 60255
- Comply to ANSI 86, 51N/51G, 51, 50N/50G, 50
T Technical Data
Power supply Storage temperature range Contact Rating
AC / DC 85 - 265V - 20 ° c to 65 ° C 5 X 106
(other voltages available on request)
Relative humidity (IEC 60068-2-30) Optional interface
Operating frequency 95% at+ 40 °C RS485 to Modbus RTU/Slave
50/60HZ
Protection Class (IEC 60529) LED status indication
Overcurrent setting
IP54 (optional with IP65 front cover) Normal operation,
20-200% in step of 1%
fault current detected
Time multiplier setting Overcurrent withstand ability
0.3 - 20.0 in step of 0.1 (ANSI, IAC) 20 times 1 rated for 3 sec (1OOA) Safety feature
0.03 - 2.00 in step of 0.01 (IEC, 1.3/10) Mechanical Trip Button
Power consumption
(MTB) complying with ANSI 86
Definite time delay setting (DTL) <6VA
0.03 - 2.00 sec in step of 0.01 sec Relay Output Housing material
Instantaneous Mode (High-set) 1 x C/0 (Changeover), 1 x N/0 (Normally Open) ABS resin complying with UL94VO
2.0 - 10.0 times setting current in step on 0.1 Net weight
Contact Rating
Approx. 390g
Pick-up current 5A at 250VAC
100 - 115% of the setting current in step of 1% Electrical Life
Reset current value 1x105
<90% of the operating value
Working temperature range
- 10 ° C to 55 °C
T MTB:
- Protrude out when relay triggered
- Hold on status without power supply I
- Push back in to reset I
1t . .� � "
�
Trip
T Features
Microprocessor-based with highest accuracy
REF 052n
IDMTL Earth Fault Relay
- Mechanical Trip Button (MTB) fault indication system
- No reqU/rement for auxiliary power supply for fault ind/cation
- Safeguard against automatic reset before fault rectification
- Curve selection In accordance with ANSI, /AC, /EC, 1.3110, Hong Kong Utilities Curve
• Normally Inverse (Nlj
• Very Inverse (VI)
• Extremely Inverse (El)
• Short Time Inverse (STlj
• Moderate Inverse (Ml)
- Trip value recording (4-memory)
- Date and time stamping for tripping
- Integrated surge arrester against transient overvoltages
- High set mode is Incorporated for instantaneous protection
- Tamper-proof design for settings protection
- Serial Interface RS485 for Modbus RTU communication (optionalj
- Type tested for EMC compliance In acc. with /EC 61000
- High immunity to electrical Interference (tested to 2.5GHz)
- Type tested In acc. with /EC 60255
- Comply to ANSI 86, ANSI 51N/51G, and ANSI 50N/50G
T Technical Data
Power supply Working temperature range Mechanical Life
AC / DC 85 - 265V - 10° c to 55° c 5 x10 8
(other voltages available on request) Storage temperature range
- 20° c to 65° C Optional interface
Operating frequency RS485 to Modbus RTU/Slave
50/60HZ Relative humidity (IEC 60068-2-30)
95% at+ 40° C LED status indication
Earth fault setting Normal operation, fault current detected
2.0- 50.0% in step of 0.1% Protection Class (IEC 60529)
IP54 (optional with IP65 front cover) Safety feature
Overcurrent setting Mechanical Trip Button
20 - 200% in step of 1% Overcurrent with stand ability
20A for 3 sec (MTB) complying with ANSI 86
Time multiplier setting Power consumption Housing material
0.03 - 2.00 in step of 0.01 (IEC, 1.3/1O) <6VA ABS resin complying with UL94VO
0.3 - 20.0 in step of 0.1 (ANSI, IAC)
Relay Output Net weight
Definite time delay setting (DTL) 1 x C/0 (Changeover),
0.03 - 2.00 sec in step of 0.01 sec Approx. 390g
1 x N/0 (Normally Open)
Instantaneous Mode (High Set)
2.0 - 10.0 times setting Contact Rating
current in step of 0.1 5A at 250VAC
Pick-up current Electrical Life
100-115% of the setting 1 X 105
current in step of 1%
Reset current value .,,---�� -
<90% of the operating value
ICJMTL EARTH FAULT RELAY IOMTL EARTH FAULT RELAY
Trip Reset
T Features
- Provides elementary protection functions
OA 703e
- Added security against nuisance trip handling
DTL Overcurrent relay
- Manual test button for relay operation checking
- ntegrated surge arrester against transient overvoltages
- Tamper-proof design for settings protection
- EMC type tested in accordance with /EC 60255-26 I /EC 61000-4 series
T Technical Data
Power supply Reset current value Output contact
AC110/240V � 90% of the operating value Mechanical > 5 x 1O operations
Voltage variation ±15% Operating and storage temperature range AC250V 2A
(other voltage available upon request) Operating-10 ° to 55 ° C Indication
Operating frequency Relative humidity Red LED (relay tripped)
50/60 z 95% at +40 ° C Green LED (aux. power)
Rated Current Degree of protection Housing material
5A (1A available upon request) IP51 (Front)/ IP20 (Rear) ABS resin complying with UL94VO
Current Setting Unit Weight
AC 2- 7A Approximately 500g
Delay Time Setting Power Consumtion
o- 1 sec �2VA
( * O to 1O sec available upon request)
Operation life expectancy
Electrical > 10,000 operations
LI L LI L
L2-------i---+-+-- 0 L2-------i----+-+-- 0 Panel cut-out
L3------------�
91.5 x 91.5 mm
mdg
L3
�
N------------------
A�"'/,'f,.,�Y
I I I
Ordering lnfomation
Model: Description
OA 703e DTL Overcurrent relay
T Features REL 10 / REL 30
Provide elementary leakage protection
Added security against nuisance trip handling
Earth Leakage panel type relay
Integrated surge arrester against transient overvoltages
Manual test button for relay operation checking
Real-time monitoring of leakage current(%)
Detection of "No-connection" to ZCT (Zero phase sequence current transformer)
Tamper-proof design for setting protection
T Technical Data
Auxiliary power supply Auxiliary supply Degree of protection (IEC 60529)
220V ±15% Green indicator Front: IP40; Back: IP20
(other voltages available upon request) Trip Assembly as per IEC 60999-1
Operating frequency Red indicator Front panel installation
50/60HZ Real-time leakage current Cable cross section
Power Consumption Green indicator; red indicator for above 75% Supply voltage 0.5 to 2.5mm2
Approximately 2.5VA ZCT connection error Output contact 0.5 to 2.5mm2
REL 1 O sensitivity current (A) Red indicator in Trip (blink) Temperature range
0.1 / 0.3 / 0.5 / 1 / 2 / 3/ 5 / 10 Outputs switching voltage Operation: -10° c to 55°C
REL 30 sensitivity current (A) Max. 250VAC Transport and storage: -20°C to 65°C
0.5 I 1 / 3/ 5 / 10 / 15 / 20 / 30 Outputs switching current Relative humidity
Delay time (sec) Max. 5A 95% at +40°C
Inst. / 0.1 / 0.15 / 0.2 / 0.25 / 0.3 / 0.4 / 0.5 Weight
T Connection Diagram
Approximately 0.3kg
TDimension
ZCT
l1 ____-/ l++---L
L2 ------1 �--0
L3 -------1 --++---A
o�0c2 c1(€v�
Ordering lnfomation
Model: Description
REL 10 Earth Leakage relay, panel type
sensitive range from 0.1 to 10A
REL 30 Earth Leakage relay, panel type
sensitive range from 0.5 to 30A
EL 03PP/10P/30
EL 03P/EL 10P/EL 30P
EL 03P
EL 03D
Setting range from 0.03 to 3A (step 0.01A)
OUV 400
Under voltage limit protection
Microprocessor controlled DTL operation
Backlit high contrast LCD display
Wide operating range AUX voltage
4 Trip event records
Sealable tamper proof front cover
The OUV400 is an over and under- voltage relay for industrial and
commercial applica on. It is used in a wide variety of voltage
sensi ve equipment such as 3-phase AC motor, pump and
ven la on fan require a balanced supply voltage to operate
efficiently.
ANSI 59 – Overvoltage
Protec on and Func onality Descrip on
ANSI 27 – Undervoltage
Maximum Delay Time 60 seconds (step of 0.01s)
System Voltage Se ng 60VAC to 480VAC (Line Voltage)
Pick Up Voltage Se ng:
• 100% to 130% of System Voltage (step of 1%)
• Over Voltage
• 70% to 100% of System Voltage (step of 1%)
• Under Voltage
Reset (Clear) Voltage Se ng:
• 100% to 130% of System Voltage (step of 1%)
• Over Voltage
• 70% to 100% of System Voltage (step of 1%)
• Under Voltage
Pick Up Accuracy ± 0.5% of full scale
Reset Accuracy ± 1% of full scale
± 3% of Trip Time or +/- 20ms whichever is higher
Time Accuracy
(at no delay se ing max 50ms)
Opera ng voltage AUX AC/DC 85-265V (other voltage available upon request)
Power consump on < 4VA
Overvoltage – NC/NO (250VAC 5A)
Tripping Output Relay Contacts
Undervoltage – NO (250VAC 5A)
Display type Backlit LCD high contrast display
Relay Status Indicator Tripped – Red Color LED
Opera ng temperature 0 – 60°C
Trip Event recording 4 event recording
Opera ng humidity < 95% RH (non-condensing)
Access control User configurable PIN password
Housing material ABS resin comply with UL94VO
Unit weight Approximately 330g
Unit dimension 96mm (width) x 96mm (height) x 86mm (depth)
OUV 400
User Interface Features
1. Real me system voltage reading
2. Func on indicators
3. Type of fault indicator
4. Trip status indicator
5. Func on bu ons
6. Test and Reset bu ons
7. Trip info display
VP 006
voltage/over voltage protection relays to
continuously monitor AC power supplies both
single phase and three phase.
●Knob-adjustable separately for over voltage
and under voltage. If voltage is over or under
than the setting voltage for over 0.1-10 sec
(adjustable), then the output relay will be
released.
●Indicators
Power supply ON (Un) Green indicator
Output ON Red indicator
Under voltage limit (U<) Red indicator
Over voltage limit (U>) Red indicator
Operation Chart
T Productselection guide
• /EC 61869-2 for performance of Instrument transformer
• /EC 60044-1 for manufacturing and testing method used
• IP 20 Degree of Protection for indoor application Metering CT
Class 0.5 For kWh revenue meter application where accurate recording of energy
Customized CT consumption is required. 0.5% Current (Ratio) Error at 100% Rated
• MH CT is available in custom built specification such as PX type requirement Current.
• We have over 20 years' experience in making CT Class 1 For general metering of feeder 1 % Current (Ratio) Error at 100% Rated
Current.
with precise tolerance & special performance
Class 3 For industrial load status indication purpose. 3% Current (Ratio) Error at
100% Rated Current.
°T'Productdescnption Protection CT
5P For stringent time graded coordination protection scheme. 5% composite
error at rated Accuracy Limit Factor.
MH Current Transformer (MH CT) is used in energy metering and feeder protection application.
Designed for use in low voltage 50/60Hz network, the CT is installed in electrical switch board, 1OP For general time coordination and instantaneous over current scheme.
control panel and motor control centre. High grade annealed grain-oriented silicon steel is 10% composite error at rated Accuracy Limit Factor.
used in the CT core to provide improved accuracy and linearity of measurement.
PX Special application where protection scheme requires precise parameter
The CT can be directly installed onto bare copper busbar up to 720VAC rating. Available in a defined for Knee Point Voltage, Turn Ratio, Maximum Excitation Current at
Knee Point, CT Secondary Resistance. (Customized built item).
wide variety of dimensions and current ratio rating. Connection to the Secondary winding is
made via 2 bolt terminal. Customized model can be manufactured to customer specification. Examples of CT Specification
Metering CT e.g. 400/5, CL1 10VA
400A Primary Full Load, 5A Secondary Output,
MH CT is manufactured to comply with /EC 60044-1 standard and /EC 61869-2. This ensures
10VA Burden, Class 1
that each CT will provide measurement at its rated accuracy when operating at fluctuating
temperature, humidity, surge impulses and radio interference. Additional requirement for Protection CT e.g. 1600/5, 5P10 15VA
1600A Primary Full Load, 5A Secondary Output,
protective CT is applied to ensure its reliable operation in the event of heavy fault condition.
15VA Burden, 5P10 Stringent Time Coordination
with 10x Accuracy Limit Factor.
v
/
18
/
16
14 I/ l/
v
/
12
v
--
10 v
l/ --------
-
-- - -- -
8 /v /
__,,,..,..
;v
6 /
-v-
4 / __,,,..,...,..
2 / �
i..--
c-
,t p
-
T Mun H ean A C Current Transformer
Model Type Rate Burden (VA) ID(mm) OD(mm) H(mm)
Myanmar Philippines
MH POWER MYANMAR CO LTD MH POLY-ELECTROMECHS, INC
No. 96 Yadanar Myaing Street 11th Floor, CyberOne Building
Off Yangon-lnsein Road (West Side) Eastwood Cyberpark, Brgy. Bagumbayan
Kamaryut Township, Yangon, Myanmar Quezon City 1110, Philippines
Tel: +95 1-505 364 Tel: +63-2 8366 8381 / +63-2 8366 8341
Fax: +95 1-505 364 Fax: +63-2 8366 8451
Email: mhmyanmar@munhean.com Email: mhpoly@munhean.com.ph