fischer epoxy mortar

FIS EM Plus
The powerful mortar for injection rebar connection and
cracked concrete

NEW
Concrete

Optimized formulation for even


more power in concrete.
Assessment for seismic applications.
Crack Concrete

Rebar Concrete

ETA-17/0979
ETA-17/1056 EAD 330499-00-0601
ETAG 001- 5
Option 1 for cracked concrete

by
Post-installed rebar connection
(TR23) Seismic performance category C1, C2

See ICC-ES
Evaluation Report
at www.icc-es.org

ESR-1990
fischer
Injection System FIS EM Plus
The powerful injection mortar for rebar connection and cracked concrete
Compatible anchor and connector

An epoxy based mortar

The epoxy resin based injection mortar has an extremely


high bonding strength and excellent adhesive properties.
FIS EM Plus 585 S For top performance, even at shallow embedment depth for cost-effective
Art. No. 544166
544165 fixing with maximum safety.
Suitable for hammer, pneumatic and diamond-drilled holes for maximum
flexibility on the construction site.
Can also be used under water for an optimal solution.
Ultra Mixer Red Static mixer
Exetended static mixer for safe mixture
of the mortar and simple filling of the hole,
improving efficiency

ADVANTAGES FUNCTIONING
High bond strengths and minor The injection system, comprising the
mortar shrinkage allow maximum epoxy resin mortar FIS EM Plus
load application in cracked and no- combined with the FIS A threaded
FIS AM
cracked concrete, even with large rod. is suitable for pre-positioned
threaded rod diameters and push-through installation.
Variable anchorage depths from 4x Resin and harder are stored in two
to 20x the threaded rod diameter separate chambers and are not
APPLICATIONS allow for ideal adaptation to the mixed and actived until extrusion
Approved for anchorings in : load to be applied, and ensure an through the injection capsule in the
optimised installation time and use static mixer.
Heavy steel constructions
of materials. The mortar isinjected bubble-free
Silo installations
FIS EM Plus is also approved for from the drill hole base.
Tall shelving
diamond-drilled and water-filled drill The mortar bonds the entire surface
Sound barriers
holes, thus ensuring more flexibility of the anchor rod with the drill hole
Jointers for concrete layers
on the construction site. wall and seals of the drill hole.
Rim beam anchorings
The wide range of approved steel The anchore rod is set manually by
Anchorings in diamond-drilled drill
types allows for use in all corrosion lightly rotating it until it reaches the
holes
resistance classes and offers the drill hole base
Fixings in waterfilled drill holes
best possible application safety. During push-through installation, the
Seismic Application
annular gap between the anchor rod
Processing and curing times and attachment is filled with FIS EM
Plus.
System temperature [°C] – 5 to –1 2) 0 to +4 +5 to + 9 + 10 to +19 + 20 to + 29 + 30 to + 40
Maximum processing time [minutes] 180 150 120 30 14 7
Minimum curing time 1) [hours] 200 90 40 18 10 5
In damp concrete and water-filled drill holes, the curing time is to be doubled.
BUILDING MATERIALS
1)
2) Not covered by ETA

Pre-positioned installation Approced for anchorings in :


1 2 3 4 5 6 Concrete C20/25 to C50/60,
cracked and non-cracked
Also suitable for :
Natural stone with dense structure

Push-through installation

1 2 3 4 5 6
fischer
Injection System FIS EM Plus
The powerful injection mortar for rebar connection and cracked concrete
Compatible anchor and connector

Your advantages at a glance Injection Mortar


FIS EM Plus 390 S
The optimised formulation of the epoxy mortar FIS EM Plus
leads to improved load values in cracked and non-cracked
concrete
The mortar can be used for rebar connections from diameter
8 to 40 mm
With the threaded rod FIS A the loads to be introduced can
be designed variably by selecting the anchorage depth.
Temporary and detachable fixing points are possible with the
internal threaded anchor RG M I
FIS EM Plus is to be processed for use on site even at low
0
temperatures down to 0 C ( outside of the evaluation even
0
down to -5 C )
The mortar is approved for diamond-drilled and water-filed drill
holes as well as seismic applications in performance categories
C1, C2 and thus offer safety under extreme conditions.

FTR S FTR
Reinforcement bar

Rebar connections Structural strengthening / connection Water-filled drill holes

Diamond-drilled drill holes Extreme loads Steel structure anchor


Injection mortar FIS EM Plus with Threaded rod FIS A / FTR-S
zinc plated steel 5.8 / zinc plated steel 8.8

Permissible loads of single anchor in normal concrete of strength class C20/25 (~B25) 1) 3) 4)

Non-Cracked Concrete Cracked Concrete


Type Material Min Effective Installation Permissible Permissible Required edge distance Permissible Permissible Required edge distance
fixing member anchorage Torgue tension shear load (with one edge) for Required Minimum spacing while tension shear load (with one edge) for Required Minimum spacing while
element thickness depth load Spacing for reducing the load load Spacing for reducing the load
Max. Max.
Max. shear Min. Min. edge Max. shear Min. Min. edge
tension Max. Load tension Max. Load
load spacing distance load spacing distance
load load

hmin hef5) Tinst Nperm6) V perm6) c c scr smin7) cmin7) Nperm6) V perm6) c c s smin7) cmin7)
[mm] [mm] [Nm] [kN] [kN] [mm] [mm] [mm] [mm] [mm] [kN] [kN] [mm] [mm] [mm] [mm] [mm]
100 60 75 180 5.4 90 105 180
70
5.8 110 80 9.0 5.1 55 240 7.2 5.1 120 95 240
FIS A / 190 160 40 60 480 9.0 65 80 480
10 40 40 40 40
FTR/S M8 100 60 11.2 100 130 180 5.4 90 185 180
8.8 110 80 8.6 130 117 240 7.2 8.6 170 240
13.8 120
190 160 40 90 480 13.8 115 480
100 60 11.2 100 125 180 6.7 90 185 180
5.8 120 90 8.6 110 105 270 10.1 8.6 135 155 270
13.8
FIS A / 230 200 45 85 600 13.8 75 110 600
20 45 45 45 45
FTR/S M10 100 60 11.2 100 200 180 6.7 90 295 180
8.8 120 90 20.5 13.3 200 170 270 10.1 13.1 135 250 270
230 200 22.4 45 115 600 22.4 150 150 600
100 70 14.1 145 175 210 10 105 255 210
5.8 140 110 12.0 165 130 330 17.8 12.0 165 195 330
20.5
FIS A / 270 240 45 100 720 20.5 60 135 720
40 55 55 55 55
FTR/S M12 100 70 14.1 145 295 210 10 105 435 210
8.8 140 110 27.7 19.4 250 230 330 17.8 19.4 165 340 330
270 240 32.4 45 150 720 32.4 145 200 720
120 80 17.2 160 305 240 12.3 120 445 240
5.8 170 125 33.6 22.3 285 235 375 24.0 22.3 190 350 375
FIS A / 360 320 37.6 50 175 960 37.6 95 195 960
60 65 65 65 65
FTR/S M16 120 80 17.2 34.4 160 495 240 12.3 24.5 120 495 240
8.8 170 125 33.6 285 405 375 24 190 600 375
36 36
360 320 60 120 220 960 60 225 320 960
140 90 20.5 170 435 270 14.6 29.3 135 530 270
5.8 220 170 53.3 34.9 385 300 510 30.5 255 455 510
39.4
FIS A / 450 400 58.6 55 230 1200 58.6 115 260 1200
120 85 85 85 85
FTR/S M20 140 90 20.5 41.1 170 525 270 14.6 29.3 135 530 270
8.8 220 170 53.3 385 525 510 38 255 780 510
56.0 56
450 400 93.3 230 290 1200 93.3 340 435 1200
160 96 22.6 45.2 170 540 290 16.1 32.2 145 545 290
5.8 270 210 73.2 475 390 630 52.2 315 590 630
50.9 50.9
FIS A / 540 480 84.3 60 250 1440 84.3 160 330 1440
150 105 105 105 105
FTR/S M24 160 96 22.6 45.2 170 540 290 16.1 32.2 145 545 290
8.8 270 210 73.2 475 675 630 52.1 315 1005 630
80.6 80.6
540 480 134.3 360 365 1440 134.3 475 570 1440
170 108 27.0 54 195 605 325 19.2 38.5 165 610 325
5.8 310 250 95.1 565 460 750 67.8 375 695 750
65.7 65.7
FIS A / 600 540 109.5 75 295 1620 109.5 240 390 1620
200 120 120 120 120
FTR/S M27 170 108 27.0 54 195 605 325 19.2 38.5 165 610 325
8.8 310 250 95.1 565 805 750 67.8 375 1200 750
105.1 105.1
600 540 175.2 505 450 1620 175.2 615 700 1620
190 120 31.6 63.2 210 660 360 22.5 45.1 180 665 360
5.8 350 280 112.7 635 525 840 80.3 420 820 840
80.6 80.6
FIS A / 670 600 133.8 80 330 1800 133.8 300 555 1800
300 140 140 140 140
FRS/S M30 190 120 31.6 63.2 210 660 360 22.5 45.1 180 665 360
8.8 350 280 112.7 635 920 840 80.3 420 1400 840
128.6 128.6
670 600 213.8 610 515 1800 213.8 725 965 1800

For the design the complete assessment ETA-17/0979 has to be considered.7)


1) The partial safety factory for material resistance as regulated in the ETA-17/0979 as well as a partial safety for load actions of L = 1.4 are considered.
As a single anchor counts e.g. an anchor with a spacing s > _ 3 h ef and an edge distance c >
_1,5 h ef Accurate data see ETA-17/0979
2) Also valid for anchor rod RG M in the same property class
3) For higher concrete strenght classes up to C50/60 higher permissible loads may be possible
4) Drill method hammer drilling resp. hollow drilling. For futher allowable drill methods and application
5) For combinations of tensile loads and shear for shear loads with lever arm (bending moments)
6) Minimum possible axial spacings resp. edge distance while reducing the permissible load
7)The given loads refer to the European Technical Assessment ETA-17/0979, issue date 06/04/2018
Design of the loads accroding to FprEN 1992-4:2017 and TR 055 (for static resp quasi-static loads)
8) A reinforcement in the concrete to prevent splitting is required. The width of the cracks has to be limited under consideration of the splitting forces at
wk~ 0.3 mm

Call us NOW PT. Bersama Bangun Persada to place your order

HEAD OFFICE BRANCH OFFICE


Ruko Rungkut Makmur Blok D55
Jl. Raya Kelapa Nias GN 11- 12 Email : info@mrsafetygroup.com Website : www.mrsafetygroup.com
Jl. Raya Kali Rungkut No.27
Kel. Kelapa Gading Barat, Kec. Kelapa Gading inovative.building.solution.system Surabaya 60293
Jakarta Utara 14250 @Mr_SafetyGroup Telp : ( 031 ) 878 3761, 878 3762
Telp. (021) 2245 9009 Fax. (021) 2245 7985 Mr. Safety Group Fax : ( 031 ) 878 3763