You are on page 1of 2

File: 06-fc2384b Page 1 of 2

Fault Code 2384 (ISB/QSB Automotive and Industrial Application)

VGT Actuator Driver Circuit - Voltage Below Normal, or Shorted to Low Source

CODES REASON EFFECT

Fault Code: 2384 VGT actuator driver circuit - Possible low power. Power removed from the
PID(P), SID(S): S027 voltage below normal, or shorted turbocharger actuator motor.
SPN: 641 to low source.
FMI: 4/4
Lamp: Amber
SRT:

Turbocharger Actuator Motor Circuit

Circuit Description:
The electronic control module (ECM) controls the turbocharger actuator motor, which changes the airflow of the
turbocharger based on various engine operating conditions. The sliding nozzle in the turbocharger is operated by the
turbocharger actuator motor. The actuator is a DC motor that receives voltage from the ECM.

Component Location:
The turbocharger actuator motor is part of the turbocharger actuator assembly, which is located on the exhaust side of
the engine and is mounted to the bearing housing of the turbocharger. Refer to Procedure 100-002 for a detailed
component location view.

Shop Talk:
A possible cause of this fault is the turbocharger actuator signal (+ or -) leads can be shorted to ground in the harness,
motor, or the ECM.
Do not supply voltage of any kind to the exhaust gas recirculation (EGR) valve motor. This circuit uses a pulse-width-
modulated signal and direct voltage can permanently damage the motor.

Refer to Troubleshooting Fault Code t05-2384

© 2008 Cummins Inc., Box 3005, Columbus, IN 47202-3005 U.S.A. Printed from QuickServe® Online.
All Rights Reserved. Last Modified: 08-Jul-2010
File: 06-fc2384b Page 2 of 2

© 2008 Cummins Inc., Box 3005, Columbus, IN 47202-3005 U.S.A. Printed from QuickServe® Online.
All Rights Reserved. Last Modified: 08-Jul-2010

You might also like