2015/06/25 Air Conditioning E13 - Fresh Air Sensor (Open Circuit) (RENR7298-37)
Diagnostics
PIP
1. Measure the value of the resistance in the fresh air sensor. See "Specifications". Proceed to step 2.
-
202 011 1
2. If the resistance value is incorrect see step 3. If the resistance value is correct see step 4.
8
3. Replace the fresh air sensor.
2
19: /08/2 791
4. Disconnect the connectors from the sensor and measure the voltage between the connectors OR/BU and GY/YL. See "Specifications".
Proceed to step 5.
5
RE :11- 7 3
5. If the voltage value is incorrect see step 6. If the voltage value is correct see step 7.
N
6. Check the harness and repair the harness between the connector and the control panel. Also, check the system power source.
©2 R 0 3
729 :00
7. Fit the sensor and measure the voltage between terminals 10 and 14 of the control panel. See "Specifications". Proceed to step 8.
0
8. If the voltage values are incorrect see step 9. If the voltage values are correct see step 10.
Cat 2 C2 8
9. Check the harness and repair the harness between the connector and the control panel.
Specifications
e r
Con pilla terpia
Resistance in the fresh air sensor
fide r: llar
25 °C (77 °F) ... 1700 Ω
ntia Inc
Voltage between connectors ... 5.0 V
lG .
Voltage between terminals
ree
10 °C (50 °F) ... 2.00 V
20 °C (68 °F) ... 1.49 V
PIP-10118791
2022/08/23
19:56:54-03:00
i02252443
Caterpillar:
Confidential Green