Fire and gas system very important in gas plant, oil plant, onshore, offshore,
petrochemical plant, refinery and etc
Fire and gas sys is monitor the complete plant by use of safety.
Type of fire
Class-A fire
Class A fire is paper, wood, cloth, rubber, plastic this type of material fire.
That is call class-A fire. Water is best solution for stop fire.
Class-B fire
If any electrical equipment fire that is call class-B fire. Do not use water for
stop fire. Use only following CO2 sys or FM200 or Inergen or DCP.
Class-C fire
If any oil or gas or chemical liquid fire that is call class-C fire. Do not use
water for stop fire. Use the following method only. DCP (dry chemical power) or
Foam system it will stop fire.
Class-D fire
Potassium, sodium, magnesium this type of chemical is fire. That is call class-
D fire. Do not use the above technique for class –D fire. Only use special
technique for particular chemical.
1. Smoke detector.
Smoke detector is install indoor purpose only. It will use to monitoring the
substation, control room, computer room, electrical room, office and etc. It
will install only inside the room. If any smokes come to the area, the smoke
detector will give signal to FACP panel. It will give alarm to the location.
2. Flame detector.
Flame detector is use to monitor the flammable area. It will install the maximum
flammable area. Inside the transformer room, generator room, inside the plant
and etc. types of dete. (a) IR-Infra Red
(b) UV-Ultra Violet.
3. Heat detector
Heat dete is installing in maximum flammable area. Two type of detector
available one is indoor type another one is outdoor type. Tea room, kitchen room,
transformer room, generator room, compressor pump, inside the plant maximum
flammable area, near the oil or chemical or gas storage tank or drum. Manuf
name is FELWEL, Detronic.
4. Gas detector
Hydrocarbon gas means mixer of hydrogen gas with carbon. Example of
hydrocarbon gas is methane, propane, butane, and pentane. Like L.P.G) it is
very important in gas plant and oil plant. Different types of hydrocarbon gas
detector available. It is use to monitor the gas leakage area. It will install near
the maximum gas leakage area like storage tank, compress room, blower or
compressor pump, this gas is easily fire (flame, combustion). If the gas leaked,
the plant will trip. It has two level of LEL. One is high level and another level is
high-high level.
5. Control sys
Control system is use to prevent the fire. Means stop the fire.
If any real fires come, automatic or manual relies the CO2, inergen and FM200.
It store in cylinder. This type of Inergen, CO2 and FM200 system is mostly used
for substation, electrical room, computer room and machinery room to prevent
fire. This system will call suppression sys.
6. Sprinkler sys
This system is used for stop the fire. This sys is used for warehouse, storage
room. If the temperature is reach 79c-96c degree the sprinkler glass will break.
Then the water will spray the fire area.
Pressurised water will stay in the pipe line. If the pressure if reduce 1bar shorten
time. Fire water pump will start. Water pressure will maintain by jacke pump.
9. PA –sys
It is public address system. It is used to give announcement for people for
attention purpose.
11. CCTV sys - It is used for monitor the total plant and security system.
12. Inergen sys
Inergen is a mixture of nitrogen, argon, & carbon dioxide, and has been specially
developed to provide fire protection for sensitive electrical and electronics
instrument and equipment,
(Nitrogen 52%, Argon 40%, Co2 8%)
Inergen extinguishes fire by reducing the oxygen level in room to below 15% the
point at which most combustible less will no longer burn.
Its offer excellent & equipment by providing a safe, clean & efficient fire
supervision agent the agent works by lowering oxygen content within the
protected environmental to a level below that witch combustion can take place.
Vesda is a laser based smoke detector, vesda having 4 alarms level, vesda
detect fire before burning stent, vesda only smoke connected with fire.
LHD sensor consist of a sensing element which respond to a specific temp. At any
point along there length. The inner conductors are coated with a polymer that the
melts at a predetermined temp. Which allow the conductors to make contact with
one another and there by signal and alarm condition
What is Maximo?
Computerised maintenance management system, to maintain the historical log
and perform the auto generation of PM and CM activity.