You are on page 1of 1

TANK DETAILS OPERATION CONDITIONS

LOCATION: OUTDOORS - HYDROGEN PEROXIDE


FLUID: -
DIMENSIONS: D: 4 600, H: 6 000 mm (REAGENT SOLUTION)
QUANTITY: 1 - MAXIMUM S.G. IN OPERATION : 1.70 -
ROOF TYPE: SELF-SUPPORTED CONE ROOF - pH : < 1.0 -
BOTTOM SLOPE TYPE: FLAT - FLUID DESIGN TEMPERATURE: 15 °C
FIELD ERECTED/SHOP FABRIC.: SHOP FABRICATED - SOLIDS PERCENTAGE: - wt %
AMBIENT TEMPERATURE: -10 TO 22 °C
DESIGN DATA DESIGN FLOW : 0.32 m³/h
DESIGN CODE: API 650 - MAXIMUM DRAINAGE FLOW : 11.3 m³/h
IMPORTANCE FACTOR (SEISMIC): 1.25 - NET WORKING CAPACITY: 81.1 m³
MINIMUM FILL LEVEL: 310 mm TOTAL CAPACITY (O/F LEVEL): 89.5 m³
NORMAL FILL LEVEL: 5 190 mm
DESIGN LIQUID LEVEL (BOTTOM O/F): 5 390 mm WIND LOAD DATA
TESTING: (D) - NOTE 10
INSPECTION: (D) - SEISMIC LOAD DATA
SHELL: 0 mm NOTE 10
CORROSION
ROOF PLATE: 0 mm
ALLOWANCE
BOTTOM PLATE: 0 mm
DESIGN JOINT EFFICIENCY: (D) - OTHER DATA
DESIGN FILLING RATE: 11.3 m3/hr
DESIGN EMPTYING RATE: 50 m3/hr INSULATION SHELL: - NO
DESIGN SCALE THICKNESS ON (MINERAL WOOL) ROOF: - NO
- mm
NOTES : WETTED SURFACES: RADIOGRAPHY: (D) YES
1) DIMENSIONS IN mm (S.I.C.). DESIGN SCALE DENSITY: NA t/m3 FOUNDATION TYPE (RING WALL
TBD YES
2) DIAGRAM AND ACCESSORIES ARE NOT SCALED ONLY FOR REFERENCE. / SLAB / STRUCTURE):

3) SUPPLIER MUST DEVELOP DESIGN AND FABRICATION DRAWINGS ACCORDING TO THE INFORMATION INDICATED IN THIS DATASHEET AND THE ASSOCIATED TECHNICAL B PAINT CLASS INTERIOR: - NO
DOCUMENTATION. (NOTE 8) EXTERIOR: - NO
4) LOCATION, ELEVATION AND POSITION OF NOZZLES AND ACCESSWAY MUST BE VERIFIED ACCORDING TO THE LAST DATASHEET REVISION. INTERIOR: NA mm
LINING
5) ALL ACCESORIES WILL BE DESIGNED, SUPPLIED AND INSTALLED BY THE MANUFACTURER OF THE TANK, WITH THE EXCEPTION OF THOSE INDICATED "BY OTHERS". EXTERIOR: NA mm
6) NA: NOT APPLICABLE. TBD: INFORMATION TO BE DEFINED. TBC: INFORMATION TO BE CONFIRMED.
7) FOR ANCHOR BOLTS LOCATION AND DIMENSIONS / OPENING LOCATIONS, THE SUPPLIER MUST ADJUST ACCORDING TO NOZZLES LOCATION. ACCESSORIES
BASED ON THE ABOVE, THE SUPPLIER MUST SPECIFY DIAMETER, STEEL TYPE AND ANCHORING SYSTEM DIMENSIONS REQUIRED ACCORDING TO ITS OWN CALCULATIONS. DISTRIBUTOR: - NO

A
ANCHORAGE SHALL BE DESIGNED FOR SEISMIC FORCES ACCORDING TO ICC IBC 2018 AND PERUVIAN SEISMIC CODE E.030 2018, EARTHQUAKE-RESTRAINT DESIGN. LEVEL SENSOR: (BY OTHERS) YES
8) FOR SHOP PRIMING AND PAINTING SPECIFICATION REFER TO DOCUMENT N° 26280-220-3GS-M000-00002 "GENERAL SPECIFICATION FOR SHOP PRIMING AND PAINTING" AGITATOR: - NO
EL. +0,00 mm -
9) FOR SERVICE PLATFORM DETAILS, THE SUPPLIER MUST CONSIDER THE DOCUMENT N° 26280-220-3DR-S01-00001 "STRUCTURAL DESIGN CRITERIA". AGITATOR SUPPORT: NO
10) FOR GENERAL SITE CONDITIONS SPECIFICATION REFER TO DOCUMENT N° 26280-220-3GS-M000-00003 "GENERAL SPECIFICATION FOR CLIMATIC & SEISMIC CONDITIONS" LADDER: (D), (NOTE 9) YES
ELEVATION & PROJECTION DETAIL
11) (D) INDICATES INFORMATION PROVIDED BY TANK SUPPLIER/DESIGNER. TYP. FOR SHELL FITTINGS SERVICE PLATFORM: (D), (NOTE 9) YES
12) NOZZLE FLANGES CONNECTIONS FROM ROOF MUST BE ABOVE ELEVATION OF THE SERVICE PLATFORM ALLOWING SUFFICIENT CLEARANCE FOR MAINTENANCE AND BAFFLE: - NO
OPERATION ACTIVITIES. OVERFLOW BIN: - NO
13) FOR TANK DETAILS ABOUT NOZZLES, ANCHOR CHAIRS, ACCESSWAY, DIP PIPES, ETC. REFER TO DOCUMENT N° "26280-420-MT-1000-00001s01, s02 & s03 – STANDARD This Datasheet supersedes Datasheet BOBCAT ACCESS: - NO
TANK DETAILS – API 650 TANKS – SHEET 1, 2 & 3". FLAME ARRESTOR: - NO
26280-220-MLD-MTSS-01001 HANDRAILS: (D), (NOTE 9) YES
LIFTING ACCESORIES: (D) YES
TANK WALL AND FLOOR ACCESSORIES ROOF ACCESSORIES SHEAR KEY / STOPPER: - NO
N1 DRAINAGE 2 A182 - F316L 80S CL150 (D) (D) 200 14° (D) N4 LEVEL SENSOR CONNECTION TBD A182 - F316L 80S CL150 (D) (D) TBD 284° TBD WALL: SS 316L / 316, (D) mm
MATERIAL AND
N2 LEVEL OBSERVATION GLASS 2 A182 - F316L 80S CL150 (D) (D) 200 14° TBD N5 FEED 2 A182 - F316L 80S CL150 (D) (D) 200 14° TBD FLOOR: SS 316L / 316, (D) mm
THICKNESS
N3 LEVEL OBSERVATION GLASS 2 A182 - F316L 80S CL150 (D) (D) 200 14° TBD N8 SPARE 2 A182 - F316L 80S CL150 (D) (D) 200 104° TBD ROOF: SS 316L / 316, (D) mm
N6 OVERFLOW 3 A182 - F316L 80S CL150 (D) (D) 300 14° 5 420 N9 SPARE (LEVEL TRANSMITTER) 4 A182 - F316L 80S CL150 (D) (D) 300 104° TBD 2nd BOTTOM MATERIAL - NO
N7 PRODUCT OUTPUT 1/2 A182 - F316L 80S CL150 (D) (D) 200 104° 210 - VENT 3 A182 - F316L 80S CL150 (D) (D) TBD TBD TBD PLATE: THICKNESS - mm
MH1 ACCESSWAY 30 SS 316L / 316 - (D) (D) (D) 200 270° 900 MH2 ACCESSWAY 30 SS 316L / 316 - (D) (D) (D) 250 194° TBD
DOCUMENTS ASSOCIATED
P&ID 26280-220-M6-1820-00001
PFD 26280-120-M5-1800-00009
DIAM. FLANGE LENGTH NOZZLE ELEVAT
REFER. SERVICE SCH RATING TYPE FACING
(INCH) DESCRIPTION (mm) ORIENT. (mm)

DIAM. FLANGE LENGTH NOZZLE ELEVAT.


REFER. SERVICE SCH RATING TYPE FACING
(INCH) DESCRIPTION "B" (mm) ORIENT. "A" (mm)

YANACOCHA SULFIDES CLIENT Nº:


REV
rrnicola@b
Digitally signed by:
rrnicola@bechtel.com
DEFINITIVE FEASIBILITY STUDY
Guerra Zurita,
Digitally signed by: Guerra Zurita, Yordan
Fuica Garcia,
Digitally signed by: Fuica Garcia,
DN: CN = rrnicola@bechtel.
Ceron
Digitally signed by: Ceron
Melende
Digitally signed by:
(YOGUERRA) Claudio(CEFUICAG)

HYDROGEN PEROXIDE STORAGE TANK BECHTEL Nº:


Melendez, Paula

echtel.com
DN: CN = Guerra Zurita, Yordan com DN: CN = Fuica Garcia, Claudio Manriquez, Francisco
Yordan (YOGUERRA) email = yoguerra@bechtel.
Date: 2021.09.21 18:53:37 - Claudio (CEFUICAG) C = US O = Bechtel
DN: CN = Melendez,
Paula C = US O = Bechtel DN: CN = Ceron Manriquez,

(YOGUERRA)
com OU = 01_Users, AMERS, LIM
Date: 2021.09.20 15:37:17 -05'00' 03'00' (CEFUICAG)
Global Corporation
Date: 2021.09.27 12:10:53 -03'00' z, Paula Global Corporation
Date: 2021.09.29 15:32: Manriquez, Francisco email =
fjceronm@bechtel.com OU =
33 -03'00'
01_Users, AMERS, STO

Francisco
29-SET-2021
Date: 2021.09.30 18:00:45 -

B ISSUED FOR QUOTE YG RN CF PM / FC


03'00'

DATA SHEET 26280-220-MTD-MTSS-01001 B


REV. Nº DATE REASON FOR ISSUE BY CHECK EGS PE / PEM CLIENT Equipment TAG: 1820-TK-001 Sheet: 1 of 1

Electronic documents, once printed, are uncontrolled and may become outdated.
Refer to electronic documents in MM Yanacocha on Aconex for current revisions.
Confidential. © 2021 Bechtel Chile Ltda. All rights reserved.

You might also like