CONCRETE SPECIFICATIONS:
CONCRETE CYLINDER STRENGTH @ 28 DAYS, fc' : 35 MPa
CONCRETE CUBE STRENGTH @ STRIPPING, fcu : 15 MPa
REINFORCING BARS SPECIFICATIONS:
ASTM A615 : 420 MPa
ASTM A1064 (WIREMESH) : 485 MPa (min)
CONCRETE COVER : 30 ± 5 mm
This drawing is only allowed to be used for its intended purpose. Handing out this drawing to a third person is not permitted nor is its usage for other purposes permitted without our special permission.
EMBEDDED ITEMS
CODE PURPOSE DESCRIPTION NO/PC
A LIFTING 5.0T CAPACITY 2 HOLE ANCHOR 04
B FIXING
C LIFTING HOR.
NOTES:
. All Dimensions are in mm.
. Bina Will Consider The Drawing Dimensions As Final and Fit for Production.
. Finishes As Per Approved Sample.
. All Reinforcements should be black steel.
. Refer to Reinf. DWG. 487-KHB-PR-EIP-00-001R
OWNER:
SECTION A-A
SIDE-1 CONTRACTOR :
al fanar construction
PROJECT:
khobar boys elementary
SECTION B-B khbe01 school boy's elementary
(pump room)
PRECAST SUB CONTRACTOR:
BINA Advanced
Concrete Products Factory
Dammam, 2nd Industrial Area Saudi Arabia
P.O Box 1594 - Al Khobar 31952
Tel: +9663 8125555
487-KHB-PR-EIP-00-001 4