TANK DETAILS OPERATION CONDITIONS

LOCATION: INDOORS -
FLUID: LOADED ORGANIC -
DIMENSIONS: D: 2 100, H: 2 080 mm
QUANTITY: 1 - MAXIMUM S.G. IN OPERATION : 0.85 -
SELF SUPPORTED CONE ROOF
ROOF TYPE: - pH : TBD -
(REMOVABLE)
BOTTOM SLOPE TYPE: FLAT - FLUID DESIGN TEMPERATURE: 35 °C
FIELD ERECTED/SHOP FABRIC.: SHOP FABRICATED - SOLIDS PERCENTAGE: - wt %
AMBIENT TEMPERATURE: -10 TO 26 °C
DESIGN DATA DESIGN FLOW : 3.4 m ³/h
DESIGN CODE: API 650 - MAXIMUM DRAINAGE FLOW : 55.2 m ³/h
IMPORTANCE FACTOR (SEISMIC): 1.25 - NET WORKING CAPACITY: 3.5 m³
MINIMUM FILL LEVEL: 420 mm TOTAL CAPACITY (O/F LEVEL): 5.6 m³
NORMAL FILL LEVEL: 1 420 mm
DESIGN LIQUID LEVEL (BOTTOM O/F): 1 620 mm WIND LOAD DATA
TESTING: (D) - NOTE 10
INSPECTION: (D) - SEISMIC LOAD DATA
SHELL: 0 mm NOTE 10
CORROSION
ROOF PLATE: 0 mm
ALLOWANCE
BOTTOM PLATE: 0 mm
DESIGN JOINT EFFICIENCY: (D) -
DESIGN FILLING RATE: 3.4 m ³/hr OTHER DATA

DESIGN EMPTYING RATE: 55.2 m ³/hr


DESIGN SCALE THICKNESS ON INSULATION SHELL: - NO
0 mm
NOTES : WETTED SURFACES: (MINERAL WOOL) ROOF: - NO
1) DIMENSIONS IN mm (S.I.C.). DESIGN SCALE DENSITY: NA t/m 3 RADIOGRAPHY: (D) YES
2) DIAGRAM AND ACCESSORIES ARE NOT SCALED ONLY FOR REFERENCE. FOUNDATION TYPE (RING WALL /
TBD YES
3) SUPPLIER MUST DEVELOP DESIGN AND FABRICATION DRAWINGS ACCORDING TO THE INFORMATION INDICATED IN THIS DATASHEET AND THE ASSOCIATED TECHNICAL SLAB / STRUCTURE):

DOCUMENTATION. PAINT CLASS INTERIOR: - NO


4) LOCATION, ELEVATION AND POSITION OF NOZZLES AND MANHOLES MUST BE VERIFIED ACCORDING TO THE LAST DATASHEET REVISION. (NOTE 8) EXTERIOR: - NO
B
5) ALL ACCESSORIES WILL BE DESIGNED, SUPPLIED AND INSTALLED BY THE MANUFACTURER OF THE TANK, WITH THE EXCEPTION OF THOSE INDICATED "BY OTHERS". INTERIOR: - NO
LINING
6) NA: NOT APPLICABLE. TBD: INFORMATION TO BE DEFINED. TBC: INFORMATION TO BE CONFIRMED. EXTERIOR: - NO
7) FOR ANCHOR BOLTS LOCATION AND DIMENSIONS / OPENING LOCATIONS, THE SUPPLIER MUST ADJUST ACCORDING TO NOZZLES LOCATION.
BASED ON THE ABOVE, THE SUPPLIER MUST SPECIFY DIAMETER, STEEL TYPE AND ANCHORING SYSTEM DIMENSIONS REQUIRED ACCORDING TO ITS OWN CALCULATIONS. ACCESSORIES
ANCHORAGE SHALL BE DESIGNED FOR SEISMIC FORCES ACCORDING TO ICC IBC 2018 AND PERUVIAN SEISMIC CODE E.030 2018, EARTHQUAKE-RESTRAINT DESIGN. DISTRIBUTOR: - NO
8) FOR SHOP PRIMING AND PAINTING SPECIFICATION REFER TO DOCUMENT N° 26280-220-3GS-M000-00002 "GENERAL SPECIFICATION FOR SHOP PRIMING AND PAINTING" LEVEL SENSOR: (BY OTHERS) YES
9) FOR SERVICE PLATFORM DETAILS, THE SUPPLIER MUST CONSIDER THE DOCUMENT N° 26280-220-3DR-S01-00001 "STRUCTURAL DESIGN CRITERIA". AGITATOR: - NO

A
10) FOR GENERAL SITE CONDITIONS SPECIFICATION REFER TO DOCUMENT N° 26280-220-3GS-M000-00003 "GENERAL SPECIFICATION FOR CLIMATIC & SEISMIC CONDITIONS" AGITATOR SUPPORT: - NO
11) (D) INDICATES INFORMATION PROVIDED BY TANK SUPPLIER/DESIGNER. EL. +0,00 mm LADDER: (D), (NOTE 9) YES
12) NOZZLE FLANGES CONNECTIONS FROM ROOF MUST BE ABOVE ELEVATION OF THE SERVICE PLATFORM ALLOWING SUFFICIENT CLEARANCE FOR MAINTENANCE AND SERVICE PLATFORM: - NO
OPERATION ACTIVITIES. ELEVATION & PROJECTION DETAIL BAFFLE: - NO
TYP. FOR SHELL FITTINGS
13) FOR TANK DETAILS ABOUT NOZZLES, ANCHOR CHAIRS, MANHOLE, DIP PIPES, ETC. REFER TO DOCUMENT N° 26280-420-MT-1000-00001s01, s02 & s03 – STANDARD TANK DETAILS – API 650 TANKS – SHEET 1, 2 & 3. OVERFLOW BIN: - NO
14) NOZZLES INCLUDE DIP PIPES WHICH WILL BE SIZED AND DETAILED BY TANK DESIGNER. REFER TO DOCUMENT N° 26280-420-MT-1000-00001s03 - STANDARD TANK DETAILS - API 650 TANKS - SHEET 3. BOBCAT ACCESS: - NO
FLAME ARRESTOR: (BY OTHERS) YES
TANK WALL AND FLOOR ACCESSORIES ROOF ACCESSORIES HANDRAILS: - NO

N1 PRODUCT OUTPUT - ORGANIC FILTRATE 2 SS ASTM A182 Gr F 316L 80S CL150 (D) (D) 200 180° 220 N4 FEED - CLAY TREATMENT FILTER (Note 14), DP. 2" (D) SS ASTM A182 Gr F 316L 80S CL150 (D) (D) 200 270° (D) LIFTING ACCESORIES: (D) YES

N2 OVERFLOW 3 SS ASTM A182 Gr F 316L 80S CL150 (D) (D) 300 330° 1 660 N5 LEVEL TRANSMITTER TBD SS ASTM A182 Gr F 316L 80S CL150 (D) (D) (D) 90° (D) SHEAR KEY / STOPPER: - NO
N3 DRAINAGE 3 SS ASTM A182 Gr F 316L 80S CL150 (D) (D) 200 310° (D) N6 FIRE SUPPRESSION TBD SS ASTM A182 Gr F 316L TBD TBD (D) (D) TBD 150° (D) TANK WALL: SS ASME SA240 316/ 316L, (D) (D)
MATERIAL AND
MH MANHOLE 30 SS ASME SA240 316/ 316L (D) (D) (D) (D) 200 45° 900 N7 SPARE FEED 4 SS ASTM A182 Gr F 316L 80S CL150 (D) (D) 300 120° (D) FLOOR: SS ASME SA240 316/ 316L, (D) (D)
THICKNESS
V VENT (D) SS ASTM A182 Gr F 316L (D) CL150 (D) (D) - - (D) ROOF: SS ASME SA240 316/ 316L, (D) (D)
nd
2 BOTTOM MATERIAL - NO
PLATE: THICKNESS - mm
DIAM. FLANGE LENGTH NOZZLE ELEVAT.
REFER. SERVICE SCH RATING TYPE FACING
(INCH) DESCRIPTION "B" (mm) ORIENT. "A" (mm) DOCUMENTS ASSOCIATED
P&ID 26280-120-M6-1710-00013
PFD 26280-120-M5-1700-00003

DIAM. FLANGE LENGTH NOZZLE ELEVAT.


REFER. SERVICE SCH RATING TYPE FACING
(INCH) DESCRIPTION "B" (mm) ORIENT. "A" (mm)

Fuica Garcia,
Nicolas
Digitally signed by: Nicolas
Penaloza
Digitally signed by: Penaloza
Valenzuela, Ricardo(RRNICOLA) Arraya, Gustavo(GAPENALO)
Claudio
Ceron
Digitally Digitally signed by: Ceron
Valenzuela,
DN: CN = Nicolas Valenzuela, Arraya, Gustavo Gustavo(GAPENALO)
DN: CN = Penaloza Arraya,

YANACOCHA SULFIDES
signed by:

CLIENT Nº:
C = US Manriquez, Francisco
Ricardo(RRNICOLA) C = US O = (CEFUICAG)
(GAPENALO) ODate: = Bechtel Global Corporation Mardones,
DN: CN = Ceron Manriquez,
Ricardo
Bechtel Global Corporation Digitally signed by: Fuica Garcia,
2021.07.07 17:54:46 - Pablo

Manriquez,
Date: 2021.07.07 18:30:56 -04'00' Claudio(CEFUICAG)
Francisco email =

REV
05'00' DN: CN = Fuica Garcia, Claudio Date: 2021.
(RRNICOLA) (CEFUICAG) email =
cefuicag@bechtel.com OU =
07.08 19:02:
00 -04'00'
fjceronm@bechtel.com OU =
01_Users, AMERS, STO

11-Jul-2021 Francisco
01_Users, AMERS, STO

DEFINITIVE FEASIBILITY STUDY


Date: 2021.07.08 08:39:56 -04'00'
Date: 2021.07.11 23:05:58 -

C ISSUED FOR QUOTE RN GP CF / PMR AS / FC


04'00'

B 22-06-2021 ISSUED FOR APPROVAL RN GP CF / PMR AS / FC ORGANIC FILTRATE TANK BECHTEL Nº:
A 29-04-2021 ISSUED FOR REVIEW PZ GP CF / PMR AS / FC DATA SHEET 26280-220-MTD-MTSS-01007 C
REV. Nº DATE REASON FOR ISSUE BY CHECK EGS/PE AM / PEM CLIENT Equipment TAG: 1710-TK-021 Sheet: 1 of 1

Electronic documents, once printed, are uncontrolled and may become outdated.
Refer to electronic documents in MM Yanacocha on Aconex for current revisions.
Confidential. © 2021 Bechtel Chile Ltda. All rights reserved.