You are on page 1of 50

WCDMA Access Problems Analysis

Review

Access is associated with the call setup


success rate of the network. This KPI can be
optimized by means of “Call setup test” and the
consequent trouble-shooting based on access
failure analysis.
Objectives

When finished this course,you will be able to:

 Be familiar with the access


procedure in UMTS

 Do analysis on access problems


independently
Course Contents

Definition of access failure

Access problem analysis process

Common reasons for access problems

Case study
Definition of access failure

General originating call setup signaling flow:


Definition of access failure

General terminating call setup signaling flow:


Definition of access failure

Call setup succeeds when the call setup


phase is completed (when CC Connect is
received). If the call fails to reach the CC
Connect stage, it should be pegged as an
access failure .
Course Contents

Definition of access failure

Access problem analysis process

Common reasons for access problems

Case study
Access problem analysis process

 Preparation before Analysis

 Access problem analysis

methods
Preparation before analysis
Be familiar with the planning information which can be obtained from planning

reports;

Be familiar with history records of optimization;

Get the latest reliable summary sheet of the engineering parameters;

Get the latest configuration of radio parameters;

Obtain the network traffic statistics and the subscriber complaint information of

access.
Access problem analysis process

 Preparation before Analysis

 Access problem analysis

methods
Access problem analysis methods
General methods of access problem analysis:

Traffic statistics data analysis


Custom complaint collection

Call setup test in specific area

Coverage analysis

Signaling analysis
Access problem analysis methods

Traffic statistics data and custom complaint


collection reveal problems exactly, further
trouble-shooting can be carried out by call setup
test. While for a pre-commercial or trial network,
call setup test is the effective way.
Course Contents

Definition of access failure

Access problem analysis process

Common reasons for access problems

Case study
Common reasons for access problems

 RF reasons

 Radio Parameter Settings

 Other reasons
RF reasons

Poor coverage

Strong Uplink or downlink Interference


Common reasons for access problems

 RF reasons

 Radio Parameter Settings

 Other reasons
Radio parameter settings

Improper threshold of Qqualmin and Qrxlevmin

Improper settings of access threshold

Inappropriate settings of preamble power ramp step and retransmission times

Inappropriate setting of adjacent cells

Inappropriate setting of synchronization parameters

Unsuitable power allocation rate for common channel

Unsuitable initial power of uplink and downlink dedicated channel

Unsuitable setting of uplink Initial SIR target value of dedicated channel


Common reasons for access problems

 RF reasons

 Radio Parameter Settings

 Other reasons
Other reasons

Data configuration problems

Access problems caused by cell load


Course Contents

Definition of access failure

Access problem analysis process

Common reasons for access problems

Case study
Case study

 Access failure due to synchroni-za


tion failure

 Access failure during RB setup

 Access failure during handover pr


ocess

 Access failure due to terminating


UE
Access failure due to synchronization failure

Access failure location:


Access failure due to synchronization failure

UE Txpower reaches maximum value 21 dBm during VP call setup. So this call
setup failure may be caused by Uplink synchronization failure:
Access failure due to synchronization failure
UE does not send RRC Connection Setup Complete to RNC after receiving RRC

Connection Setup message from RNC :


Case study

 Access failure due to synchroni-za


tion failure

 Access failure during RB setup

 Access failure during handover pr


ocess

 Access failure due to terminating


UE
Access failure during RB setup
Access failure location:
Access failure during RB setup
UE Tx power is very low and downlink pilot Ec is high before access failure,but
Ec/Io is not very good :
Access failure during RB setup
The cause of call setup failure is Requested circuit/channel not available:
Access failure during RB setup
RNC didn’t receive RB
Setup Complete message
after it has sent RB Setup
message to UE. Timeout of

RNC is reached after 1.5s:


Case study

 Access failure due to synchroni-za


tion failure

 Access failure during RB setup

 Access failure during handover pr


ocess

 Access failure due to terminating


UE
Access failure during handover process
Access failure location (Scanner Rscp ):
Access failure during handover process
ScannerEc/I0 :
Access failure during handover process
Scanner BestServer :
Access failure during handover process

During access process, UE Txpower is rising rapidly :


Access failure during handover process

And the downlink Bler reaches 100%:


Access failure during handover process

UE report the measurement of cell Sc508 which request the active set update:
Access failure during handover process
The report was
received properly and
“RRC_ACTIVE_UPDATE”
was sent as response
while UE didn’t received it
which results in the
access failure:
Access failure during handover process
Let’s turn to the performance of the terminating UE. During the access process,
the measurements from the terminating UE were not satisfactory either:
Access failure during handover process
Access failure during handover process
While the radio links
hold on till successful
handover is completed:
Access failure during handover process

Then the originating UE loses connection to the network and access released
where the cause is “destination out of order” from the signal traced by the
terminating UE:
Case study

 Access failure due to synchroni-za


tion failure

 Access failure during RB setup

 Access failure during handover pr


ocess

 Access failure due to terminating


UE
Access failure due to terminating UE
Access failure location (UE Ec/I0 ):
Access failure due to terminating UE

The coverage is not bad where the UE originates the VP access:


Access failure due to terminating UE

CN send “disconnect” message with the cause “bearer capability not authorized”
before access failure:
Access failure due to terminating UE
setup signaling procedure for RRC and RAB have already finished. The cause of
disconnect is the same:
Access failure due to terminating UE
The reason is: we use two mobile to test video phone, for the originating call
mobile camped in 3G network, but the terminating call mobile camped in 2G network
that moment, so video call setup failed, the missing signaling of terminating UE can
also explain it:
Summary

Access process is complicated since different devices are


involved and scenario varies. Careful study from signal
distribution to signaling procedure makes things easy.
Examples above are derived from tests carried out before,
which give general idea of trouble shooting, advanced
researches will be supplemented. .