You are on page 1of 2

Calibration Group 30: Electrical system

N Start calibration mode


Idling

Main helm station


Preparations:
– Turn the main switches on.
– Check that the starter switch is in position 0 (off).
– Move the control lever(s) to neutral position /center
position (lever / levers “straight up”).

1
Single engine installation:
Press the neutral button N, and keep it depressed and
at the same time turn the starter key to position I
(driving position). Keep the neutral button depressed
until the yellow indication lamp by the diagnostic but-
ton gives constant light. Release the neutral button.

Twin engine installation:


Press the neutral button N, and keep it depressed and
at the same time turn both starter keys to position I
(driving position). Keep the neutral button depressed
until the yellow indication lamps by the diagnostic but-
tons give constant light. Release the neutral button.

2
The neutral button indication now flashes to confirm
that the EVC system is in calibration mode.

NOTE! The system returns from calibration mode af-


ter about 45 seconds if no other activities are done.

N Alternative helm station


Idling (without starter switch)
Preparations:
– Turn the main switches on.
– Move the control lever(s) to neutral position/ center
position (lever / levers “straight up”).
– Turn the starter key at the main helm station to
position I (driving position).

1
Press the neutral button N and the button on the
alternative helm station until the yellow indication
lamp by the diagnostic button gives constant light.
Release the buttons.

2
The indication lamp by the neutral button now flashes
to confirm that the EVC system is in calibration mode.

4
Repeat the calibration according to the instructions for
the lever configuration in question.

246
Group 30: Electrical system Calibration

Auto configuration
Auto-configuration is the system’s self-identification.
Auto-configuration should always be done when the
EVC system is started for the first time and before the
system is calibrated.

1
Start calibration mode according to instructions on
previous page.

2
Press the neutral button N and diagnostic button D at
the same time. Keep the buttons depressed until all
lamps on the control panel light up. This takes about 5
seconds.

3
Release the N and D buttons. The system responds
by switching off and then lighting up all the lamps
again.
Auto-configuration is now complete and the EVC sys-
tem has identified the components. This takes about
10 –20 seconds.

4
Turn the starter key to position 0.

247

You might also like