You are on page 1of 1

SCHEDULE OF RIGHTS

STAND NO. 3371


TOTAL AREA OF STAND - 240sqm
ZONED -RESIDENTIAL 1
HEIGHT ZONE -0.2 (STOREYS)
COVERAGE -45.75% = 109.81.67sqm
FLOOR AREA -0.5
PARKING -REMAINDER OF THE ERF

YADAH INOVATION
ARCHITECTURE
SCHEDULE OF AREAS
Mr THEOPHILUS MBEKWA
BEDROOM 5
AREA OF STAND 240sqm
Cell1: 065 865 5645
Plaster and Paint COVERAGE 45.75%
WhatsApp: 078 314 6810
EXISTING HOUSE A 42sqm Email: yadahprojectsexperts@yahoo.com
WASTE WATER: 50Ø uPVC AT MIN FALL 1:60 UNDERGROUND: 110Ø DAMP-PROOF COURSE Lufhereng
uPVC AT MIN FALL 1:60 DIRT WATER: 110Ø uPVC AT MIN FALL 1:60 The horizintal and vertical damp-proof course shall be of ALL NEW PROPOSED ALT B 67.81sqm Roodepoort
black polyethylene sheeting comply withSABS specification
952 Type B having embossed surfaces,0, 38mm thick (375 TOTAL GROUND FLOOR A+B = 109.81sqm 1724
Microns)in widths of less than 1000 mm. TOTAL GROUND COVERAGE 45.75%
North Elevation 1:100 GENERAL NOTES

KITCHEN LAYOUT AND FITTINGS BY SPECIALIST


CONCRETE ROOF TILES @ 20.0degree ANGLE ON MARLEY HIGH−QUALITY BUT TO THIS PREFERED LAYOUT.
UNDERTILE MEMBRANE (2 PLY 400 MICRON POLYPROPYLENE LAMINATE)
ON 38x38mm SA PINE PURLINS @ 345mm c/c ON ROOF TRUSSES @ 760mm FOUNDATION; COLUMNS; REINFORCED
c/c MAX ON 114x38mm TIMBER WALLPLATES PROPERLY SECURED WITH CONCRETE BEAMS AND SLABS AND STAIRS TO
ROOF WIRES TILE : DOUBLE ROMAN ’MARLEY’−STANDARD BROWN PASSAGE
(DRSTBR) TILE NAILS : 75mm x 3,35mm PITCH : 20.0.degree (75mm HEADLAP) APPOINTED ENGINEER'S DETAILS.
SIZE OF TILE : 420mm x 332mm
NEW PREMISES ARE NOT TO BE OCCUPIED UNTIL
SERVICES ARE TAKEN OVER BY LOCAL
1 300 150 1 300 150 AUTHORITY AND OCCUPANCY CERTIFICATE
ISSUED.

KITCHEN CONCRETE AND REINFORCEMENT THE ELECTRICAL LAYOUT AND SPECIFICATIONS


ARE TO BE AGREED UPON BEFORE ANY WORK
1. ALL REINFORCEMENT SHALL BE COMMENCES. GEYSER SIZES AND POSITION TO
SPECIALIST'S DETAILS. CONTRACTOR TO
SECURELY HELD IN PROPER POSITION PROVIDE WRITTEN CONFIRMATION BEFORE
2 000
WHILE POURING CONCRETE. CHAIRS, WORK COMMENCES

TIES, SPACERS, ADDITIONAL BARS AND THE CONTRACTOR SHALL BE HELD RESPONSIBLE
STIRRUPS SHALL BE PROVIDED BY THE

1 700
FOE ENSURING THE STRUCTURAL STABILITY OF
DINNING ROOM ALL COMPONENTS OF THE WORK AND MUST
Plaster and Paint CONTRACTOR TO FURNISH SUPPORT FOR ASCERTAIN THAT THE STRUCTURE IS CAPABLE OF
SUPPORTING ALL LOADS APPLIED THERETO.
ALL REINFORCEMENT.
DAMP-PROOF COURSE 2. CONSTRUCTION JOINTS SHALL BE THE CONTRACTOR MUST CHECK AND CONFIRM
ALL LEVELS AND DIMENSIONS WITHIN THOSE
The horizintal and vertical damp-proof course shall be of
black polyethylene sheeting comply withSABS specification DOWELED, KEYED AND THOROUGHLY PLANS BEFORE PREPARING THE SITE
LAYOUT,AND REPORT ANY DISCREPANCIES TO
952 Type B having embossed surfaces,0, 38mm thick (375
South Elevation CONCRETE ROOF TILES @ 20.0degree ANGLE ON MARLEY HIGH−QUALITY 1:100 CLEANED. AMOS.T FOR WRITTEN CONFIRMATION AND
Microns)in widths of less than 1000 mm.
UNDERTILE MEMBRANE (2 PLY 400 MICRON POLYPROPYLENE LAMINATE)
ON 38x38mm SA PINE PURLINS @ 345mm c/c ON ROOF TRUSSES @ 760mm
3. MINIMUM LAP OF WELDED WIRE CHANGES BEFORE ANY WORK COMMENCES.

c/c MAX ON 114x38mm TIMBER WALLPLATES PROPERLY SECURED WITH


ROOF WIRES TILE : DOUBLE ROMAN ’MARLEY’−STANDARD BROWN
675
FABRIC SHALL BE 150 mm (6") OR ONE ALL WORK AND NEW DRAINAGE TO LOCAL
AUTHORITY STANDARD AND REQUIREMENTS
FULL MESH, WHICHEVER IS GREATER.

1 136
0,5mm THICK, KLIP LOK 700 GALVANISED STEEL ROOF COVERING (DRSTBR) TILE NAILS : 75mm x 3,35mm PITCH : 20.0.degree (75mm HEADLAP)
SIZE OF TILE : 420mm x 332mm
WITH CHROMADEK COATING Z200 SPELTER ISQ550 FINISH TOP COAT
AND GREY BACKING COAT, FIXED TO STEEL CHANNEL PURLINS @ 1 321 4. COORDINATE AND INSTALL ALL WORK TO STRICTLY ADHERE TO RELEVENT SABS
REQUIREMENTS.
MAX 1700mm CENTRES. (COLOUR: TRAFFIC GREEN) REQUIRED EMBEDDED ITEMS, INSETS
AMOS.T RESERVES COPYRIGHT OF THIS DESIGN
SLEEVES, POCKETS, ETC. AS REQUIRED AND DRAWIGS.WRITTEN PERMISSION MUST BE
PRIOR TO PLACEMENT OF CONCRETE. OBTAINED FROM AMOS.T BEFORE ANY
CCOPYRIGHT OR USE (OTHER THAN FOR THIS
5. EPOXY COATED BARS MAY BE SPECIFIED STAND) IS MADE OF THIS DRAWING OR
THE INHERENT INFORMATION CONTAINED HERE-
SUBSTITUTED FOR GALVANIZED REBAR. IN.

FOUNDATION NOTES

CONCRETE STRIP FOUNDATION WITH MINIMUM


WIDTH OF 600mm AND MINIMUM HEIGHT OF
Plaster and Paint 230mm AT MINIMUM DEPHT 400mm BELOW
NATURAL GROUND LEVEL UNLESS OTHERWISE
INDICATED BY THE APPOITED ENGINEER.

WASTE WATER: 50Ø uPVC AT MIN FALL 1:60 UNDERGROUND: 110Ø


uPVC AT MIN FALL 1:60 DIRT WATER: 110Ø uPVC AT MIN FALL 1:60
Ground Floor 1:136,06 FLOOR SLAB NOTES

THEORETICAL ANNUL ENERGY CONSUMPTION CALCULATION 30mm SCREED ON 85mm CONCRETE SURFACE
BED ON WELL COMPACTED FILL. DAMP PROOF
MEMBRANE WHERE REQUIRED.
LIGHTING:50 LIGHTS
East Elevation 1:100 ENERGY COMMAND (OCCUPANCY= H4) WALL NOTES
CONCRETE ROOF TILES @ 20.0degree ANGLE ON MARLEY HIGH−QUALITY MAXIMUM ALLOWED :5W/SQM
UNDERTILE MEMBRANE (2 PLY 400 MICRON POLYPROPYLENE LAMINATE) TOTAL FLOOR AREA : UNLESS OTHERWISE SPECIFICALLY MENTIONED,
ON 38x38mm SA PINE PURLINS @ 345mm c/c ON ROOF TRUSSES @ 760mm PERMISSIBLE ON THIS HOUSE: ALL SCREEN WALLS,BOUNDARY WALLS AND
c/c MAX ON 114x38mm TIMBER WALLPLATES PROPERLY SECURED WITH GARDEN WALLS TO BE 220mm WALLS WITH MAX.
ROOF WIRES TILE : DOUBLE ROMAN ’MARLEY’−STANDARD BROWN ACTUAL USAGE :
EXTERNAL WALL CALCULATION HEIGHT OF 1800mm WITH EXPANSION JOINTS AT
(DRSTBR) TILE NAILS : 75mm x 3,35mm PITCH : 20.0.degree (75mm HEADLAP)
3500mm.NO FOUNDATIONS TO ENCROACH
SIZE OF TILE : 420mm x 332mm 0,5mm THICK, KLIP LOK 700 GALVANISED STEEL ROOF COVERING REQUIRED CR-VALUE: 8 CR/h
WITH CHROMADEK COATING Z200 SPELTER ISQ550 FINISH TOP COAT
BOUNDARIES.THE FINISH IS TO BE RENDERED IN 1
DOUBLE SKIN MASONRY : 40 CR/h COAT WOOD FLOATED PLASTER, PAINT AS

BEDROOM 5
AND GREY BACKING COAT, FIXED TO STEEL CHANNEL PURLINS @ PLASTERED AND RENDERED INTERNALLY: 20 CR/h
MAX 1700mm CENTRES. (COLOUR: TRAFFIC GREEN) SPECIFIED.
PLASTERED AND RENDERED EXTERNALLY : 20
CR/h TOTAL: :80 CR/h

LIGHTING & POWER CONSUMPTION


OWNER SIGNATURE
AS PER SANS 10114-4 & 10400-0

POWER QUANTITY WATTS

PASSAGE
Ceilling lights 21 (5W LIGHTS) 105 WATTS

Flourecen 1 (30W FLOURECENT) 30 WATTS CHIEF ARCHITECT SIGNATURE


Plaster and Paint
Total watts 135 WATTS
Per SQM

WASTE WATER: 50Ø uPVC AT MIN FALL 1:60 UNDERGROUND: 110Ø


uPVC AT MIN FALL 1:60 DIRT WATER: 110Ø uPVC AT MIN FALL 1:60
KITCHEN ENGINEER SIGNATURE

HOT WATER SERVICES


West Elevation 1:100 4.5.2.1. A MINIMUM OF 50% BY VOLUME
DINNING ROOM
0,528

Revision History
OF THE AVERAGE HOT WATER HEATING RevID ChID Change Name Date
0,268

STRUCTURAL TIMBER
TRUSS BY SPECIALIST
REQUIREMENTS SHALL BE PROVIDED BY
0,090
MEANS OTHER THAN ELECTRICITY
1,810

RESISTANCE HEATING , INCLUDED BUT


NOT LIMITED TO SOLAR , HEAT PUMPS,
HEAT RECOVERY FROM OTHER SYSTEM
OR PROCESSES. THE OWNER WILL
Proposed OUT BUILDING/ALT
INSTALL ONE OR BOTH OF THE
MAIN BEDROOM

for
IES-02 Window Schedule Site 1:177,79 FOLLOWING IN ORDER TO ARCHIVE MRS MASULUKE
Quantity 1 1 1 1 6 7 9 20
Floor construction to provide floor finish on 25mm screed on 85mm
surface bed on gunplas usb green dpc on well compacted fill
Sill height 0 400 1 600 2 500 400 1 200 400 400
COMPLIANCE: -INTEGRATED SOLAR AND on
sparayed with insect poison before dpc is layed and to be confirmed
Head height 2 100 2 100 2 100 4 000 2 100 2 100 2 100 2 100 ERF GIYANI
HEAT TANK SYSTEM TO SPECIFICATION.
by the engineer

Raft or Strip Raft or Strip Raft or Strip

AND OR -HEAT PUMP TO SPECIFICATION


Foundations according Foundations according Foundations according
to engineers details & to engineers details & to engineers details &
geotech report geotech report geotech report
Drawing Name
View from Side 4.5.2.2. THE SOLAR SYSTEM WILL Ground Floor, North Elevation,
Opposite to Opening
FLOOR TILING
400 x 400 x 9,50mm Matt porcelain floor tiles fixed with
Side COMPLY WITH THE FOLLOWING East Elevation, South
150mm SOLID WALLS WITH CRIMPED GALVANISED TIES
& BRICK FORCE EVERY 5th COURSE;CONTINUOS IN
Ceresit Tylon adhesive to screeds (screeds elsewhere)
with straight joints in both direction flush pointed with
REGULATIONS: THERMAL Elevation, West Elevation,
THE FIRST 6 COURSE OVER ALL DOOR AND WINDOW
OPENINGS.DITTO FOR 110mm WALLS.2 COAT PLASTER
Ceresit Tylon 33 tinted jointing compound PERFORMANCE SANS 1307 AND SANS Section AA, Roof Layout,
Fire Resistance
AA1 TO INTERNAL WALLS AS PER SAMPLE,AND PAINT Building Section 1:100 Rating
20 minutes 20 minutes 20 minutes 20 minutes 20 minutes 20 minutes 20 minutes 20 minutes
10106 INSTALLATION SANS 10254 Window Schedule, Building
Sound Transmission
Class
25 25 25 25 25 25 25 25 Section, Site
Nominal W x H Size 1 500×2 100 1 800×1 700 1 500×500 1 300×1 500 1 000×1 700 900×900 2 000×1 700 600×1 700

Window Schedule 1:1 HOT WATER SUPPLY CALCULATIONS Drawing Status


VOLUME OF ANNUAL HOT WATER HEATING REQUIREMENTS
POPULATION CALCULATIONS
Fenestration Calculations glazing elements (Ground floor) CONCRETE AND REINFORCEMENT
1. ALL REINFORCEMENT SHALL BE SECURELY HELD IN PROPER POSITION WHILE POURING CONCRETE. CHAIRS,
BEDROOMS: PEOPLE PER BEDROOM TOTAL BUILDING PLAN
WINDOW no #OF WINDOWS SIZE (WxH) AREA (sqm) U-VALUE TIES, SPACERS, ADDITIONAL BARS AND STIRRUPS SHALL BE PROVIDED BY THE CONTRACTOR TO FURNISH SUPPORT 5 2 10
FOR ALL REINFORCEMENT. Modified by
W1 8 1.8x 1.7 11,06sqm 3.40 2. CONSTRUCTION JOINTS SHALL BE DOWELED, KEYED AND THOROUGHLY CLEANED. HOT WATER HEATING CALCULATION
3. MINIMUM LAP OF WELDED WIRE FABRIC SHALL BE 150 mm (6") OR ONE FULL MESH, WHICHEVER IS GREATER.
MR THEOPHILUS MBEKWA
ALL WORK TO COMPLY WITH S.A.B.S. 0.400 N.B.R. AND LOCAL Everite Nutec 4mm thick plain ceiling boards, manufactured in ALL LINTELS PLACED ABOVE W2 5 0.9 x 0.9 5.81sqm 3.40 4. COORDINATE AND INSTALL ALL REQUIRED EMBEDDED ITEMS, INSETS SLEEVES, POCKETS, ETC. AS REQUIRED
PRIOR TO PLACEMENT OF CONCRETE.
DEMAND: STORAGE VALUME: HEALER POWER: Date
MUNICIPAL BYELAWS. WORKMANSHIP TO BE IN ACCORDANCE accordance with SANS 9001:2000 carrying SANS 803:2005
WINDOWS AND DOORS TO BE 5. EPOXY COATED BARS MAY BE SUBSTITUTED FOR GALVANIZED REBAR. 20L PER PERSON PER DAY UNIT/150 3KW/UNIT Checked by
WITH STANDARD CODE OF PRACTICE AND QUALITY TO
mark, fixed over timber joists at 600mm centres with 38 x W3 6 1.0 x 1.7 10.2sqm 3.40 20 x 10 = 200L a day 200L / 150 = 1.33 UNITS
38mm counter battens using 32 x 2,5mm serrated ceiling nails 3 x 1.33 = 3.9KW/DAY Yadah Projects Experts (Pty) Ltd.
ARCHITECTS APPROVAL. at 150mm centres, minimum of 12mm from edge of board, PLACED AT A HEIGHT OF 2100 W4 1 1.2 x 0.9 1.08sqm 3.40 THUS : 1423.5kw/YEAR BUT USE SOLAR PANELS = 50% SAVINGS Date
including SANS approved waterproofing membrane fixed over
counter battens. All joints to be covered using H-profile steel ABOVE T.O.C. OF FLOOR LEVEL W5 1 1.5 x 0.5 0.75sqm 3.40 Drawing Scale
jointing strips, all in accordance with the manufacturer's THUS : 1423.5kw/YEAR
recommendations. UNLESS OTHERWISE STATED W6 1 1.3 x 1.5 1.95 3.40 THUS : 1423.5kw/YEAR HOT WATER HEATING REQUIREMENTS 1:136,06, 1:100, 1:50, 1:146,09,
TOTAL AREA OF GLAZING 30.85sqm 1:1, 1:177,79
SOLAR WATER HEATING SYSTEMS WILL COMPLY WITH SANS307 SANS
NET FLOOR AREA 109.81sqm 10100. SANS 0254 AND 0252-1 STANDARD WATER INSTALLATION WILL
COMPLY WITH SANS 0252 AND SANS 10254 DATE DRAWING NUMBER
% OF FENESTRATION OF NET FLOOR AREA 14.99% 18 DEC 2020 18DEC2020
GSPublisherVersion 0.2.100.100

CONCRETE ROOF TILES @ 20.0degree ANGLE ON MARLEY HIGH−QUALITY UNDERTILE MEMBRANE (2 PLY 400
MICRON POLYPROPYLENE LAMINATE) ON 38x38mm SA PINE PURLINS @ 345mm c/c ON ROOF TRUSSES @ 760mm c/c