N
A A
B EXISTING TIMBER PILES (SHADED) C B CRANE RAIL TO COMMENCE AT CH 55.00m A NEW STEEL PILES B
CL EXIST S009 S008 S007
TO BE FITTED WITH STEEL CASING. REFER TO S070 AND S080 SERIES DRGS REFER TO S020 SERIES DRGS
SHEET PILES
REFER TO S040 AND S050 SERIES DRGS. AND DRGS S113 TO S115
4
10 EXISTING DECK STRENGTHENING
30a 40a 50a
REFER TO DRG S131 FOR DETAILS
EXISTING SHEET PILE WALL
C C
IJ
CL CRANE
RAIL
D 1 D
(E) CJ
CL EXIST
SHEET PILES
NEW CONCRETE PLINTH TO
SUPPORT NEW ICCP CABINETS.
REFER TO DRG S099 FOR DETAILS
E CL CRANE E
PROJECT SETOUT POINT EDGE OF BEAM RAIL
E +0.000 m
(2'0")
EDGE OF FENDER
610
N +0.000 m
ED
GE
(N +5812289.418m)
ED
OF
GE
(E +316236.627m)
BE
OF
INTERPRETED FROM
AM
10 20 30 40 50 55
FE
SURVEY BY MADIGAN 4
NDE
SURVEYING RECEIVED
R
CH 56.418m
0
( 2'
CH 55.00m
CH 66.00m
F F
SpiRe SYSTEM TO END AT FENDER BEAM REMEDIATION NEW LADDERS SHOWN, BOLLARDS SOUTH OF CH 30.00m REINSTATED ARCH FENDERS
CH. 60.00m. FOR SpiRe SYSTEM AND ICCP WORKS TO EXISTING LADDERS TO BE MAINTAINED (NO REMEDIATION). (NORTH OF CH 66.00m ONLY)
REFER TO S170 SERIES DRGS COMMENCE AT CH 66.00m TO BE REMOVED BOLLARDS NORTH OF CH 30.00m TO BE REFER TO MA020
REFER TO CP SERIES DRGS REPLACED UNLESS NOTED OTHERWISE. SERIES DRGS KEY
REFER TO S090 SERIES DRGS.
CRANE RAILS, CRANE RAIL SLOTS NO WHARF DECK OR PILE REMEDIATION WORKS TO
AND CABLE RECESSES TO COMMENCE SUPERCONE FENDER ASSEMBLIES BE UNDERTAKEN
AT CH 55.00m. NORTH OF CH 60.00m TO BE
REMEDIATED AND NEW CONES INSTALLED. EXISTING ELECTRICAL SERVICES
REFER TO S070 AND S080 SERIES DRGS
NOTES: AND DRGS S113 TO S115 FOR DETAILS REFER TO S090 SERIES DRGS EXISTING STORMWATER PIPE
G
1. FOR GENERAL NOTES REFER TO DRAWINGS P1359-SWA-G003 TO P1359-SWA-G005. SWANSON DOCK WEST - GENERAL ARRANGEMENT - BERTH 1 PROPOSED STORMWATER PIPE. REFER C200 SERIES DRGS
G
2. EXISTING ELECTRICAL SERVICES, STORMWATER OUTFALL PIPE POSITIONS AND WATER MAINS
1 : 250 EXISTING WATER MAIN.
SHOWN INDICATIVE ONLY. THE CONTRACTOR SHALL CHECK LOCATIONS ON SITE PRIOR TO ANY
WORKS AND PROVIDE THE REQUIRED PROTECTIONS. PROPOSED WATERMAIN. REFER C300 SERIES DRGS
3. LOCATION OF PILES ON GRIDS ADJACENT TO SERVICES SHALL BE ADJUSTED SUBJECT TO REVIEW AND
CONSENT OF THE DESIGN ENGINEER TO AVOID CLASHES WITH EXISTING SERVICES AND TO PROVIDE EXISTING SEWER
THE REQUIRED CLEARANCES DETAILED ON THE CIVIL DRAWING SET.
EXISTING COMMS
4. THE CONTRACTOR SHALL UNDERTAKE AN INDEPENDENT INVESTIGATION OF ALL RELEVANT SERVICES
INCLUDING ANY OTHER NOT SHOWN ON THIS DRAWING AND PROVIDE REQUIRED PROTECTION.
5. REFER TO DRAWINGS S021 TO S024 FOR GRID LINE DETAILS AND SPACINGS. ISSUED FOR CONSTRUCTION
CLIENT DRAWING STATUS
REV DATE DESCRIPTION DRAWN APPROVED
PORT OF MELBOURNE FOR CONSTRUCTION
PROJECT DRAWING TITLE
REVISIONS