Professional Documents
Culture Documents
LRN: 9241176
Revision Number: 9
Page 1 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Ship: LADY LINN Ship IMO: 9241176 Report Nr.: 140832 Rev.: 9 (2019)
Inspector: BAE - STH KOREA Insp. Date : 15-07-2022 Insp./Ship Type: Gas/Gas Port: Yeosu, Korea
Page 2 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Ship: LADY LINN Ship IMO: 9241176 Report Nr.: 140832 Rev.: 9 (2019)
Inspector: BAE - STH KOREA Insp. Date : 15-07-2022 Insp./Ship Type: Gas/Gas Port: Yeosu, Korea
Page 3 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
A.1.6 Dual class vessel. She was classed with VR and KR.
Comments:
(none)
Page 4 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Page 5 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Ship: LADY LINN Ship IMO: 9241176 Report Nr.: 140832 Rev.: 9 (2019)
Inspector: BAE - STH KOREA Insp. Date : 15-07-2022 Insp./Ship Type: Gas/Gas Port: Yeosu, Korea
Page 6 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Vietnam Register
1.1.31 Safety Management Certificate S Yes
1.1.32 Issued by:
Vietnam Register
1.1.33 ISSC Certificate S Yes
1.1.34 Continuous Synopsis Record (CSR) S Yes
1.1.35 IAPPC Certificate S Yes
1.1.36 IEE Certificate (IEEC) S Yes
1.1.37 EIAPP Certificates (EIAPPC), including NOx technical files when required S Yes
1.1.38 Anti-fouling Certificate, or a Statement of Compliance, has been issued S Yes
1.1.39 ISPP (International Sewage Pollution Prevention) Certificate S Yes
1.1.40 Maritime Labour Certificate or Statement of Compliance S Yes
Last Port State Control Inspection:
1.1.41 15-02-2022
Date:
1.1.42 Port:
Balingasag - Phillippines
1.1.43 All deficiencies from last Port State Control inspections have been closed out and if No, list the outstanding
deficiencies.
NS Yes
1.1.44 The vessel has not been detained as a result of Port State inspection in the last 36 months under the present
management, and if No, list detention details (port state authority, etc.) and deficiencies that led to detention.
D Yes
1.1.45 The on-line HVPQ appears up-to-date and accurately completed R Yes
1.1.46 13-07-2022
Date of HVPQ:
Remarks:
1.1.9 The vessel carries NLS certificate for Isoprene, Pentane (all isomers) and Pentene (all isomers).
Comments:
(none)
Page 7 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Page 8 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
1.3.6 There is sufficient manning to provide 2 personnel (one officer and one rating) on each Watch at all times,
including at sea and during cargo operations
S Yes
1.3.7 There is sufficient manning to provide 2 engine room personnel (one officer and one rating) on each Engine
Room Watch at all times, including at sea and during cargo operations
D Yes
1.3.8 All Officer's Certificate of Competency and endorsements are valid for the rank S Yes
1.3.9 The person designated to take charge of medical care on board is suitably qualified S Yes
1.3.10 Officers, as well as the Gas Engineer (if carried) with immediate responsibility for loading, discharging and
care in transit or handling of cargo shall have the advanced chemical, gas or petroleum specialized training R Yes
appropriate to the cargoes being carried.
1.3.11 Any other crewmember with immediate responsibility for loading, discharging and care in transit or handling
of cargo shall have the advanced chemical, gas or petroleum specialized training appropriate to the cargoes D Yes
being carried.
1.3.12 The required number of GMDSS licensed operators are carried S Yes
1.3.13 Additional officers possess appropriate certification S N/A
1.3.14 Ratings forming part of a navigational watch possess appropriate certification S Yes
1.3.15 Ratings forming part of an engine room watch possess appropriate certification S Yes
1.3.16 * The ship's personnel are able to communicate effectively in the working language of the vessel in the
S Yes
execution of their duties
1.3.17 Manuals should be written in the working language of the vessel. S Yes
1.3.18 * The working language is
ENGLISH & VIETNAMESE
1.3.19 All Watchkeeping Officers have attended Bridge Team Management/Resource Management course complying
with IMO 1.22 (IMO Model Course) within the past 5 years
D Yes
1.3.20 The company voluntarily has in place a testing program for officers to monitor continuous development in ship
board operating procedures and practices
D No
OBS: CBT training program for monitoring officers' continuous development was not provided on board.
COM:
Page 9 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Root Cause: Understanding the importance of training and assessment crews on board. The company has signed agreement with
Ocean Technology Group to deploy a program of training and evaluation officer on board. However, Some port still lockdown, the
Ocean Technology Group could not arrange technician on board to install a computer for the training program. (Please see attached
file for the agreement)
Corrective Action/ Prevention: The company and the service provider are still working together to check the information at the ports
that the ship calling to find a place where we arrange for technician on board of the vessel. ( please see email from Service provider at
attached file ).
1.3.21 Officers attend refresher courses for statutory training D Yes
1.3.22 Ratings attend refresher courses for statutory training D Yes
1.3.23 The Officers and Crew comply with the training program onboard the vessel. D Yes
1.3.24 Has the appointed safety officer received training specific to this role. R Yes
1.3.25 At least 2 officers onboard have been trained to conduct incident and accident investigations R Yes
1.3.26 All crew have received security awareness training and have a certificate of training S Yes
1.3.27 The SSO has received appropriate training and has a certificate of training S Yes
1.3.28 The current CDI online crew matrix is a true representation of the personnel onboard. R Yes
Remarks:
1.3.1 Min. Safe Manning requirements: 4 deck officers, 3 engineer officers and 4 ratings.
Actual manning level: 4 deck officers, 4 engineer officers and 8 ratings.
1.3.11 All 4 deck ratings held advanced gas tanker course certificates.
Comments:
(none)
Page 10 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
1.4.13 The ship has not been involved in a pollution incident during the past 12 months NS Yes
1.4.14 The ship has not been involved in a grounding incident during the past 12 months NS Yes
1.4.15 The ship has not been involved in a collision/allision during the past 12 months NS Yes
Remarks:
1.4.1 A LPG tanker.
The vessel participate in CAP programme.
Overall rating awarded by KR on 15/06/21 : 1.
Comments:
(none)
Page 11 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Ship: LADY LINN Ship IMO: 9241176 Report Nr.: 140832 Rev.: 9 (2019)
Inspector: BAE - STH KOREA Insp. Date : 15-07-2022 Insp./Ship Type: Gas/Gas Port: Yeosu, Korea
Page 12 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
2.1.29 Junior officers and ratings are rotated on vessels of similar class within company fleet D Yes
2.1.30 Changes of the Master and Chief Officer, or of the Chief Engineer and Second Engineer are organised to avoid a
change of officers at same time (i.e. staggered relief system)
D No
OBS: Chief engineer and 2nd engineer joined the vessel at the same time on 10/02/22.
COM:
Root Cause: At the time of the crew change, which was a strong outbreak of the COVID-19 pandemic, almost areas where the vessel
arrived were locked down. Fearing that the situation might get worse, the Company made all efforts to change the crew as soon as it
was approved by the port authority.
Corrective Action: Because of force majeure, the company had to change 2 management officers of the engine department at the same
time and assessing the risks of this task, so the company has arranged to strengthen technical supervisions to closely follow all
activities of the ship from shore side and the Chief Engineer who has handed over is also in ready to provide remote support to the
Chief Engineer on board. Besides, the Chief Engineer has a lot of experience on this ship type ( Gas Carrier â please see
Crewmatrix).
Recurrence Prevention: Now the impact of the Covid-19 pandemic has decreased at some country, the Company will try the best to not
change the deck/engine management officers on board the ship at the same time.
Page 13 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Ship: LADY LINN Ship IMO: 9241176 Report Nr.: 140832 Rev.: 9 (2019)
Inspector: BAE - STH KOREA Insp. Date : 15-07-2022 Insp./Ship Type: Gas/Gas Port: Yeosu, Korea
Chapter: 3: Bridge
Section: 1: Navigation and Bridge Organization
Questions Cat Answer
3.1.1 There is a Company Manual detailing navigation procedures and bridge organization S Yes
3.1.2 There is evidence that the firmware and software of navigation and communication equipment have been updated to
the latest requirements.
S No
OBS: Shore-based maintenance was provided for GMDSS equipment only and did not include electronic navigation equipment such as
ECDIS.
COM: (I) The ship's PSM includes detailed checklists for onboard equipment combined with forms in the company's safety management
system, including forms for GMDSS & Navigation equipment.For GMDSS equipment we have annual service follow Shore-based
maintenance and with Navigation equipment such as Radar, Ecdis, Gyro... we also have service partners like MARITECH, DMT ...
quick support for us and we contact with maker for have a good support if necessary (please see some maintenance reports from them
for navigation equipment as attachment).
(II) DPA is still considering to have amendments to bring better efficiency in developing and implementing PMS on board of the vessel
include maintainence from shore. Therefore, the inclusion of navigation equipment into Shore based maintenance will be considered
for the next amendment of PMS in the near future.
3.1.3 The Master has established his own bridge standing orders R Yes
3.1.4 The duties of the watch officer are clearly defined in the bridge procedures S Yes
3.1.5 Officers countersign bridge procedures and standing orders D Yes
3.1.6 Basic watch conditions are defined S Yes
3.1.7 There is a watch handover procedure S Yes
3.1.8 Inspection rounds are undertaken after the watch and reported to the bridge D Yes
3.1.9 The occasions on which the Master is to be called to the bridge are clearly defined S Yes
3.1.10 A bridge order book is kept by the Master D Yes
3.1.11 Officers countersign the Master's orders. D Yes
3.1.12 The Bridge Logbook is correctly completed, including all appropriate activities to be recorded. S Yes
3.1.13 Passage planning is conducted from berth to berth S Yes
3.1.14 Passage planning is in accordance with industry recommendations and guidelines R Yes
3.1.15 Specialized charts relative to the trading area of the vessel are available onboard and appropriately used in passage
planning.
D Yes
3.1.16 ECDIS is installed on-board the vessel NS Yes
If Yes:
There is evidence that the ECDIS and the software is approved by flag administration. S Yes
3.1.17 Officers must have familiarization training for the equipment installed on-board S Yes
3.1.18 Officers have attended a manufacturer type-specific course or computer based training for the equipment installed
on-board
R Yes
3.1.19 The company has a procedure addressing the use of ECDIS/ECS and the correction process for the system. S Yes
3.1.20 The company has a clear policy regarding minimum acceptable parameters on alarm settings and layers for use with
ECDIS/ECS.
S Yes
3.1.21 The Master has established standing orders in alignment with the above, and they are being complied with. S Yes
3.1.22 ECDIS is not the primary means of navigation NS N/A
Page 14 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
If Yes:
3.1.23 The vessel must have paper charts onboard as the primary system of navigation. S N/A
3.1.24 Bridge watchkeeping officers are aware that the ECDIS and/or ECS cannot be used as the primary means for
navigation.
R N/A
3.1.25 The ECDIS charts must be the official approved charts S Yes
3.1.26 The full passage must be planned in the ECDIS S Yes
3.1.27 The full passage plan must be available in the ECDIS utilizing all necessary charts of the appropriate scale S Yes
3.1.28 The ENC license are valid for all passage charts S Yes
3.1.29 A procedure that is based upon a risk assessment that provides for continued safe navigation (even if only to reach
safe waters) in the event of complete ECDIS failure is available onboard
S Yes
3.1.30 Appropriate intervals of position fixing are clearly defined within the passage plan R Yes
3.1.31 Navigation warnings and T&P notices are taken into account in passage planning and during the voyage S Yes
3.1.32 The position is fixed at sufficiently frequent intervals to ensure that the ship follows the planned course S Yes
3.1.33 While at anchor, the position of the vessel must be monitored and recorded at sufficiently frequent intervals S Yes
3.1.34 More than one method of fixing position was used during deep sea passages S Yes
3.1.35 More than one method of fixing position was used in coastal waters S Yes
3.1.36 The watch officer has unrestricted access to navigation systems S Yes
3.1.37 The watch officer has unrestricted access to communication systems S Yes
3.1.38 The watch officer has unrestricted access to use of the engines S Yes
3.1.39 The depth finder is operated when making a landfall and in coastal waters R Yes
3.1.40 The Navtex is operating on the appropriate station(s) for the ship's location S Yes
3.1.41 The Navtex is programmed to receive navigation warnings and weather forecasts S Yes
3.1.42 Navtex navigation warnings are correctly managed and filed S Yes
3.1.43 There is evidence that the ship receives maritime weather forecasts appropriate for the vessel and trading area S Yes
3.1.44 Master / pilot information exchange procedures are in use S Yes
3.1.45 Ship maintains full navigation procedures when the pilot is on-board S Yes
3.1.46 Exchange procedures for the Master to assume control from the duty officer are clearly defined and recorded S Yes
3.1.47 A magnetic compass deviation card / table is available on the bridge S Yes
3.1.48 Magnetic and gyro compasses are compared at least each watch S Yes
3.1.49 Magnetic compass error is determined at least once per watch and, when possible, after any major alteration of course S Yes
3.1.50 Navigation equipment is checked before each voyage and before entering port S Yes
3.1.51 A record of navigation equipment checks and findings is made in the ship's Log Book S Yes
3.1.52 * Testing of astern propulsion before entering port is recorded R Yes
3.1.53 Testing of the steering gear before arrival and departure is recorded S Yes
3.1.54 Testing of the emergency steering at least every three months is recorded S Yes
3.1.55 Manoeuvring information is posted in the wheelhouse S Yes
3.1.56 Auto / manual steering changeover procedure is displayed on the bridge S Yes
3.1.57 Emergency steering changeover procedure is displayed on the bridge S Yes
3.1.58 The vessel utilizes approved charts that are up-to-date and appropriate for the voyage. S Yes
3.1.59 Corrections of Nautical Publications are up-to-date to latest appropriate Notices to Mariners S Yes
3.1.60 The ship subscribes to a chart and nautical publication update service (Paper or ENC, as applicable) D Yes
Page 15 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
3.1.61 There are Company procedures covering the correction and / or renewal of charts and nautical publications S Yes
3.1.62 The ship has guidelines / graphs regarding squat S Yes
3.1.63 The Master and bridge officers are aware of the conditions which create squat S Yes
3.1.64 The Company provides fully documented policy or procedure on minimum Under Keel Clearance (UKC) R Yes
3.1.65 * The operational condition of the appropriate equipment appears satisfactory: S Yes
3.1.66 * If No, how many items were not satisfactorily recorded?
3.1.67 The ECDIS is correctly displaying ENC Chart No. 1. S Yes
3.1.68 The company has a procedure for maintaining the ECDIS software, firmware and hardware up to date, and service
reports are available on board.
S Yes
3.1.69 The operational condition of the appropriate equipment (when fitted), appears satisfactory: R Yes
3.1.70 If No, how many items were not satisfactorily recorded?
Electronic Chart System (ECS)
3.1.71 The ECS is correctly displaying ENC Chart No. 1. S N/A
3.1.72 The company has a procedure for maintaining the ECS software, firmware and hardware up to date, and service
reports are available on board.
S N/A
3.1.73 The operational condition of all navigation, signal lights and alarms is satisfactory S Yes
3.1.74 Navigational shapes are readily available for hoisting and are in satisfactory condition S Yes
3.1.75 The operational condition of the Aldis signalling lamp is satisfactory S Yes
3.1.76 The operational condition of all communication links between Bridge and Engine Room is satisfactory S Yes
3.1.77 Input from the speed log to the anti collision system is speed through the water S Yes
3.1.78 VDR equipment is tested and, when possible the complete retention of data, is verified to insure operation of the
system
S Yes
3.1.79 The AIS display and keyboard should be available to the mariner at the position from which the ship is normally
operated
R Yes
3.1.80 AIS is switched off or operating at a low power setting of 1 watt or less when required R Yes
3.1.81 A Bridge Navigation Watch Alarm System (BNWAS) is fitted S Yes
3.1.82 Is there a Company procedure in place preventing distraction of personnel on the bridge while on duty. D Yes
Remarks:
3.1.16 ECDIS was approved by DNV. Manufacturer: Transas, Model: Navi-Sailor 4000.
3.1.29 Take-home charts were carried and cellphone-based back-up program was in use.
3.1.67 Presentation library was updated up to 4.0ed.
Page 16 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Chapter: 3: Bridge
Section: 2: Radio and Communications
Questions Cat Answer
3.2.1 A certificated operator is designated to have primary responsibility for radio communications during distress incidents S Yes
3.2.2 Portable intrinsically safe radio handsets are provided to deck watchkeepers R Yes
3.2.3 GMDSS Station (applicable to the area) is fitted and appears operational S Yes
3.2.4 A GMDSS Radio Log is maintained up to date S Yes
3.2.5 The main transmitting aerials are earthed / grounded during cargo operations R Yes
3.2.6 VHF/UHF radio equipment is operating at low power setting when required R Yes
3.2.7 Communication equipment is clearly marked with the call sign, ship station identity an other applicable codes S Yes
3.2.8 Operating guidance for distress situations is displayed in close proximity to the communications equipment S Yes
3.2.9 Compartments containing batteries comply with the regulations related to closing appliances, ventilation and posting of
warning notices.
S Yes
3.2.10 Batteries (and fittings) used as a reserve source of energy for the radio installation are in apparent good condition S Yes
3.2.11 Condition of the reserve source of energy for the radio installation is regularly recorded S Yes
3.2.12 There are at least two correctly located radar transponders (SARTs) S Yes
3.2.13 Corrections of Radio Lists are up to date to latest Notices to Mariners received S Yes
3.2.14 At least three two-way VHF radiotelephone apparatus are on board for use in the survival craft S Yes
3.2.15 Corrections of Radio Lists are up to date to latest Notices to Mariners received S Yes
Remarks:
(No remarks)
Comments:
(none)
Page 17 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Chapter: 3: Bridge
Section: 3: Crew Knowledge and Proficiency
Questions Cat Answer
3.3.1 Bridge watchkeeping officers are familiar with the international collision regulations S Yes
3.3.2 Bridge watchkeeping officers are familiar with buoyage systems S Yes
3.3.3 Bridge watchkeeping officers are familiar with procedures for handing over or taking charge and his duties when he is in
charge
S Yes
3.3.4 Bridge watchkeeping officers are familiar with the company procedures and Master's standing orders for being called to
the bridge
S Yes
3.3.5 Bridge watchkeeping officers are familiar with the operation and limitations of all bridge equipment S Yes
3.3.6 Bridge team personnel are familiar with the Bridge Procedures Guide, including when under pilotage S Yes
3.3.7 Personnel are familiar with the applicable emergency procedures as listed in the Guidance Notes for 7.1.2 S Yes
3.3.8 Personnel are aware of which equipment will switch over to battery or reserve power in case of a power outage D Yes
3.3.9 Bridge team personnel are familiar with other aspects of the bridge and navigational policies and procedures S Yes
Remarks:
(No remarks)
Comments:
(none)
Page 18 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Ship: LADY LINN Ship IMO: 9241176 Report Nr.: 140832 Rev.: 9 (2019)
Inspector: BAE - STH KOREA Insp. Date : 15-07-2022 Insp./Ship Type: Gas/Gas Port: Yeosu, Korea
Chapter: 4: Mooring
Section: 1: Mooring
Questions Cat Answer
4.1.1 * The Company has procedures on safe mooring which reflect industry standards R Yes
4.1.2 * The ship is moored in accordance with industry standards R Yes
4.1.3 While moored, ship's staff are maintaining a regular inspection of the moorings R Yes
4.1.4 * There are sufficient crew available to safely moor the ship R Yes
4.1.5 * While in port, deck machinery is ready for use at all times D Yes
4.1.6 * The ship has a maintenance programme for the mooring equipment S Yes
4.1.7 * The ship is fitted with self-storing mooring winches NS Yes
If Yes:
4.1.8 * There is a schedule for the testing of the winch brake rendering capacities R Yes
4.1.9 * There are records indicating the testing of winch brakes R Yes
If Yes:
4.1.10 Winch brakes are tested every _____ months 12
4.1.11 All mooring lines are correctly spooled on mooring drums R Yes
4.1.12 The mooring winches appear in good working condition R Yes
4.1.13 The windlass appears in good working condition with bearings greased etc. R Yes
4.1.14 * The anchors and anchor chains appear in good working condition S Yes
4.1.15 * The anchor cable stoppers appear in good condition D Yes
4.1.16 * Anchors are cleared for use when entering port R Yes
4.1.17 * Condition of mooring ropes, wires and lines (as fitted) appear satisfactory S Yes
4.1.18 * Synthetic mooring tails are fitted NS No
OBS: Synthetic mooring tails were not fitted.
If Yes:
4.1.19 * Synthetic mooring tails appear to comply with OCIMF guidelines R N/A
4.1.20 Synthetic mooring tails are connected with a non-friction connection when required R N/A
4.1.21 * Certificates are available for all mooring wires and ropes R Yes
4.1.22 * Emergency towing off wires (fire wires), appear in good condition R Yes
4.1.23 * When rigged, emergency towing off wires (fire wires) are properly rigged R Yes
4.1.24 * Fairleads and rollers are free and well greased S Yes
4.1.25 * Emergency towing procedures must be maintained on board the ship for ready use by the shipâ s crew in
S Yes
preparing their ship for towage in an emergency.
4.1.26 The emergency towing arrangement, if fitted, complies with SOLAS requirements and is in good condition S N/A
4.1.27 * Decks in the mooring areas have a non slip surface D Yes
4.1.28 * Snap-back areas have been identified via risk assessment R Yes
Remarks:
Page 19 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Page 20 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Chapter: 4: Mooring
Section: 2: Crew Knowledge and Proficiency
Questions Cat Answer
4.2.1 Personnel are aware of routine for tending of moorings S Yes
4.2.2 Personnel are aware of safety issues related to mooring S Yes
4.2.3 Personnel are aware of the purpose and proper rigging for towing off wires R Yes
4.2.4 Personnel are able to explain the principles behind testing of brakes, and can explain the difference between rendering
point and design brake holding capacity
R Yes
4.2.5 Personnel are familiar with the hazards and risks of moorings, including the location of snap-back areas S Yes
4.2.6 Personnel are familiar with other aspects of mooring equipment, policies and procedures S Yes
Remarks:
(No remarks)
Comments:
(none)
Page 21 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Ship: LADY LINN Ship IMO: 9241176 Report Nr.: 140832 Rev.: 9 (2019)
Inspector: BAE - STH KOREA Insp. Date : 15-07-2022 Insp./Ship Type: Gas/Gas Port: Yeosu, Korea
Page 22 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
5.1.25 A cross check is being carried out by a 2nd individual on the cargo line-up prior to commencement of cargo transfer,
and records maintained.
D No
OBS: Double checks on cargo line-up were reportedly carried out. However, documentary evidence was not sighted.
COM: I/C: Double checks on cargo line-up did not record by C/O & Officer in charge.
R/C: Cargo Log Book did not record although before cargo operation, C/O and other people relating to cargo operation also have a
short meeting .
C/A:Right after that the C/O record the double check for cargo line-up into Cargo Log Book. Please kindly find the attached cargo
Log Book was be record.
R/P: Safety meeting to remind C/O and all crew should maintain and proper record in cargo Log book.
5.1.26 * Are stability limitations included in the operational instructions R Yes
5.1.27 * Do these instructions reference the ship's loading and stability data R Yes
5.1.28 * The duty officer has signed the cargo operations plan and is operating in compliance with the plan R Yes
5.1.29 * If changes are required to the cargo operations plan, a system is in place for updating the plan and ensuring that
R Yes
officers and crewmembers involved in the cargo operations are aware of the changes
5.1.30 * A record of cargo activities is maintained in port S No
OBS: Port log was not maintained. Memo for entry of time sheet was kept.
COM: Immediate Cause / Root Cause: before cargo operation, C/O and other people relating to cargo operation also have a toolbox meeting
however, relative cargo operation just record with time sheet only he did not record more activities of cargo operation in cargo log
(port log).
Corrective Action: Right after that the C/O record into Cargo Log Book the C/O record the briefing on his order book each of cargo
operation. Please kindly find the attached Cargo Log book record at Yeosu-South Korea on 15 Jul. 2022.
Recurrence Prevention: Safety meeting to remind all crew should maintain record all activities on board during cargo operation and
control by C/O.
5.1.31 Records of cargo tank levels are maintained D Yes
5.1.32 Records of cargo pump performance are maintained D Yes
5.1.33 A deck watch is maintained throughout the cargo transfer operation D Yes
5.1.34 * When applicable, flame screens for specified cargoes are available, in good condition and used when appropriate S N/A
5.1.35 * When carried, there are records indicating the inspection and maintenance of flame screens S N/A
5.1.36 * Propylene Oxide and/or mixtures of ethylene oxide/propylene oxide are listed in the Certificate of Fitness. NS No
OBS: PO and EO/PO mixtures were not listed in the certificate of fitness.
If Yes:
5.1.37 * Cargo handling plan and drawings are available and approved by the administration. S N/A
5.1.38 * Before each initial loading and before every subsequent return to such service, the cargo system must be properly
segregated, each blank flange sealed with a wire and seal to avoid inadvertant removal, and certification of segregation S N/A
issued by a responsible person acceptable to the Administration.
5.1.39 * Testing of relief valves is carried out by a competent authority at regular intervals and tests recorded S Yes
5.1.40 There are records to indicate the regular testing of air lock alarms and interlocks R N/A
5.1.41 There are records to indicate the regular testing of high level alarms R Yes
5.1.42 * There are records to indicate the testing/function of independent high level shutdown system R Yes
5.1.43 * There are records indicating that the cargo tank filling valves are tested at intervals not exceeding one week D Yes
5.1.44 * There are records indicating the regular testing of high and low pressure alarms R Yes
5.1.45 * There are records indicating the inspection / checking of inert gas system non-return valves R Yes
5.1.46 * Procedures are in place to fully segregate the inert gas piping from hold spaces when the system is connected to the
D Yes
cargo system.
5.1.47 * There are records indicating that calibration checks have been carried out on cargo plant instrumentation S Yes
Page 23 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Page 24 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
5.1.83 * If yes, the minimum permitted cargo temperature is displayed at or near the control position and at the manifold D Yes
5.1.84 * A cargo compressor room/ space is fitted NS Yes
If Yes:
5.1.85 * Bulkhead seals appear in good condition S Yes
5.1.86 * The arrangements of the cargo compressor room/ space are in compliance with the requirements. R Yes
5.1.87 * The ventilation system appears to be operating correctly R Yes
5.1.88 * All protective devices appear operational S Yes
5.1.89 * Compressors and associated equipment in the cargo system appear fully operational S Yes
5.1.90 * Procedures are available detailing when freezing point depressants may be used when a means of hydrate control is
R N/A
provided
5.1.91 When applicable, a Certificate of Protection (Inhibitor Certificate) is available S Yes
Remarks:
5.1.40 No air lock alarm was fitted. The entrance to motor room was located in safe zone on foc'sle deck.
5.1.71 The vessel has 1 grade cargo capability.
Comments:
(none)
Page 25 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Page 26 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Page 27 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
If Yes:
5.3.25 Local and remote vapour space pressure readings coincide D Yes
5.3.26 There are records indicating that calibration checks are carried out between the ship's vapour space pressure gauges
and any remote readouts
D Yes
If Yes:
5.3.27 Records indicating satisfactory completion of calibration checks within the last 12 months are available for the remote
tank pressure gauge
D Yes
5.3.28 * Pressure relief valves with variable settings are fitted to the cargo tanks NS Yes
If Yes:
5.3.29 * The high pressure alarm for each cargo tank is correctly set for the safety valve setting in use S Yes
5.3.30 * The correct setting is displayed at the location of each pressure relief valve S Yes
5.3.31 * The correct setting is displayed in the cargo control station / room (if provided) S Yes
5.3.32 * Changes to the set pressure of the pressure relief valves is recorded in the ship's log book S Yes
5.3.33 * Where fitted, each pilot operated pressure relief valves has the a pilot valve serial number corresponding to the
R Yes
safety valve serial number
5.3.34 * The atmosphere in the hold spaces is controlled using dry inert gas or dry air, when applicable, and maintained
S N/A
above atmospheric pressure
5.3.35 The medium used for controlling the atmosphere in hold spaces is dry air NS N/A
5.3.36 The medium used for controlling the atmosphere in hold spaces is dry inert gas NS No
OBS: Dry inert gas was not used for hold spaces.
5.3.37 The same density or reduction tables for cargo calculations are used at both loading and discharging ports D Yes
5.3.38 If Bill of Lading is based on shore measurements instructions are provided in the event of cargo measurement
discrepancy
D N/A
5.3.39 Pressure/temperature requirements at receiving terminals are available on board D Yes
5.3.40 Cargo heater(s), if fitted, utilizes a cascade system such that seawater is not in direct contact with the cargo to be
heated
NS N/A
5.3.41 There is a method in place to monitor cargo heaters for gas leakages when in use D N/A
5.3.42 There is a written instruction for cargo conditioning at sea D Yes
5.3.43 A Company manual contains procedures for reporting any cargo non compliance D Yes
5.3.44 The Master has received operational instructions for the execution of the voyage D Yes
5.3.45 In the event of cargo pump failure, an emergency discharge method is available S Yes
Remarks:
5.3.15 To be NA. Local temperature readouts only were available.
Comments:
(none)
Page 28 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Page 29 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Page 30 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Ship: LADY LINN Ship IMO: 9241176 Report Nr.: 140832 Rev.: 9 (2019)
Inspector: BAE - STH KOREA Insp. Date : 15-07-2022 Insp./Ship Type: Gas/Gas Port: Yeosu, Korea
Page 31 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
(none)
Page 32 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Page 33 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Page 34 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Remarks:
Machinery spaces were maintained clean and tidy. Considering her age of 21, machinery spaces were well maintained.
Comments:
(none)
Page 35 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Page 36 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
procedures.
6.5.15 Personnel are familiar with other aspects
of the engine department policies, R Yes
procedures and hazards
Remarks:
(No remarks)
Comments:
(none)
Page 37 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Ship: LADY LINN Ship IMO: 9241176 Report Nr.: 140832 Rev.: 9 (2019)
Inspector: BAE - STH KOREA Insp. Date : 15-07-2022 Insp./Ship Type: Gas/Gas Port: Yeosu, Korea
7.1.7 07-06-2022
__________
7.1.8 Enclosed space entry and rescue drills should be held every 2 months S Yes
7.1.9 Company emergency response procedures on-board the vessel provide details of reporting to: Authorities S Yes
7.1.10 Company emergency response procedures on-board the vessel provide details of reporting to: Company S Yes
7.1.11 Company emergency response procedures on-board the vessel provide details of reporting to: Charterer D Yes
7.1.12 * Safety signs and / or notices are displayed on deck and in the accommodation R Yes
7.1.13 * Smoking areas are clearly marked, procedures clearly displayed, and procedures are being complied with by
R Yes
personnel
7.1.14 There is a Company procedure to prohibit the use of portable non-intrinsically safe equipment in hazardous areas,
and personnel are complying with the procedure and safe operating practices
R Yes
7.1.15 * When in use, metallic portable pumps are properly grounded D Yes
7.1.16 * Lighting on deck is adequate and in an operational condition R Yes
7.1.17 * Lighting in and around accommodation, in machinery spaces and all other working areas is adequate and in an
R Yes
operational condition
7.1.18 The company has procedures for conducting risk assessment S Yes
7.1.19 Risk assessments are being carried out S Yes
7.1.20 Company procedures and permits are in use and adequately/appropriately completed for: Entry into enclosed
spaces
S Yes
7.1.21 * Company procedures and permits are in use and adequately/appropriately completed for: Hot work S Yes
7.1.22 * Company procedures and permits are in use and adequately/appropriately completed for: Work on pipelines and
R Yes
pressure vessels
7.1.23 * Company procedures and permits are in use and adequately/appropriately completed for: Pressure testing of
R Yes
piping and hoses
Page 38 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
7.1.24 Company procedures and permits are in use and adequately/appropriately completed for: Working aloft or
outboard
R Yes
7.1.25 Company procedures and permits are in use and adequately/appropriately completed for: Working on electrical
circuits
R Yes
7.1.26 * Controls are in place for small craft alongside R Yes
7.1.27 Up to date and complete Muster Lists and Emergency Instructions are displayed in required locations S Yes
7.1.28 Lifejacket donning instructions are displayed S Yes
7.1.29 A procedure is available on the bridge for use during helicopter operations R Yes
7.1.30 The condition of all cranes, derricks and other lifting devices, including loose lifting equipment, is satisfactory. R Yes
7.1.31 There are records indicating the regular inspection of cranes, derricks and other lifting devices. S Yes
7.1.32 There are records indicating the regular inspection of all loose lifting gear, including chains, blocks and tackles,
hooks and swivels, etc., as carried.
S Yes
Remarks:
(No remarks)
Comments:
(none)
Page 39 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Page 40 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Ship: LADY LINN Ship IMO: 9241176 Report Nr.: 140832 Rev.: 9 (2019)
Inspector: BAE - STH KOREA Insp. Date : 15-07-2022 Insp./Ship Type: Gas/Gas Port: Yeosu, Korea
Page 41 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
8.1.32 * There are Company safety procedures covering the following operations: Transferring flammable / toxic
S Yes
cargoes
8.1.33 * There are Company safety procedures covering the following operations: Working with power tools R Yes
8.1.34 * There are Company safety procedures covering the following operations: Working with burning torches and / or
R Yes
welding equipment
8.1.35 * There are Company safety procedures covering the following operations: Dealing with static electricity R Yes
8.1.36 * There are Company safety procedures covering the following operations: Use of deck cranes D Yes
8.1.37 * There are Company safety procedures covering the following operations: Avoiding slips and falls D Yes
8.1.38 * There are Company safety procedures covering the following operations: Securing walkways D Yes
8.1.39 * The pilot ladder(s) appears in good condition S Yes
8.1.40 The pilot ladder(s) are in compliance with IMPA recommendations. R Yes
8.1.41 * The gangway / accommodation ladder is available and maintained in accordance with appropriate requirements. S Yes
8.1.42 * A gangway / accommodation ladder is safely and appropriately rigged when in use R Yes
8.1.43 * The Company has a written policy on drug and alcohol abuse that is displayed on-board in a public location R Yes
8.1.44 * There are Company procedures detailing the testing of officers and crew for drugs and alcohol, including
R Yes
unannounced testing and testing after an incident on-board
8.1.45 * Required testing frequency for drugs is _____ months 12
8.1.46 * Required testing frequency for alcohol is _____ months 1
8.1.47 * Company procedures detail the maximum acceptable alcohol level for any crew member R Yes
8.1.48 If Yes:
8.1.49 * The maximum level is _________(units) 2
8.1.50 * Company procedures detail the required period of abstinence before watchkeeping R Yes
If Yes:
8.1.51 * The required period is ______ hours 4
8.1.52 Company procedures prohibit the misuse of legitimate drugs as well as the use, possession, distribution or sale of
illicit / un-prescribed controlled drugs
R Yes
8.1.53 Company procedures detail on board alcohol distribution and consumption R Yes
If Yes:
8.1.54 The procedures are displayed in a public location D Yes
8.1.55 Company procedures detail the conduct of on board tests for alcohol D Yes
8.1.56 Alcohol test equipment is available on board D Yes
If Yes:
8.1.57 Senior officers have been trained in the use of the alcohol test equipment D Yes
8.1.58 There are records indicating that unannounced testing for drugs and alcohol are carried out D Yes
If Yes:
8.1.59 Records indicate that the Master and all crew were tested for alcohol NS Yes
8.1.60 Dates of last two alcohol tests: 15-06-2022
8.1.61 __________ 15-05-2022
8.1.62 Records indicate that the Master and all crew were tested for drugs NS Yes
8.1.63 Dates of last two drug tests: 15-06-2022
8.1.64 __________ 16-03-2022
Page 42 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
8.1.65 The company has procedures in place for handling substances hazardous to health R Yes
8.1.66 If the vessel has asbestos onboard, there is an up-to-date inventory, and detailed procedures for handling the
material.
S Yes
8.1.67 Substances hazardous to health, including engine room chemicals are safely stowed in a well ventilated area S Yes
8.1.68 If obtainable, an MSDS is available to all personnel for each substances that may be hazardous to health, including
paints, solvents, tank cleaning chemicals and engine room chemicals
S Yes
Remarks:
(No remarks)
Comments:
(none)
Page 43 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
17-08-2020
__________
8.2.14 When carrying toxic cargoes, suitable personal toxic gas detectors are available and in use when in the cargo area. D Yes
8.2.15 An oxygen resuscitator is available on board, ready for immediate use, and appears in good operating condition S Yes
8.2.16 There are at least two oxygen analyzers available on board S Yes
8.2.17 When the nitrogen generator is installed outside the engine room or a nitrogen receiver or buffer tank is installed in
a dedicated compartment, the space of the compartment should be installed with an independent mechanical R Yes
extraction ventilation system, and a low oxygen alarm shall be fitted for the space.
8.2.18 All oxygen analyzers are calibrated as per manufacturer's instructions, calibration checks recorded, and appear in
good operating condition
S Yes
8.2.19 There are on board at least two portable sets of gas detection equipment suitable for the products carried. S Yes
8.2.20 Number of portable instruments: 2
8.2.21 * All portable gas detection equipment appears in good operating condition S Yes
8.2.22 Calibration checks of all portable gas detection equipment are recorded S Yes
8.2.23 * Designated crew members are familiar with the use and calibration of portable gas detection instruments S Yes
8.2.24 A permanently installed system of gas detection is fitted NS Yes
If Yes:
8.2.25 Regular testing of the gas detection equipment is recorded S Yes
8.2.26 Calibration checks of the gas detection equipment are recorded S Yes
8.2.27 A supply of suitable span gas is available on board S Yes
Page 44 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
8.2.28 Gas detection equipment, including audible and visual alarms, appears to be in good operating condition S Yes
8.2.29 The gas detection equipment alarm is audible and visible from the deck area D Yes
8.2.30 The gas detection system is fitted with high and low sampling heads / sensors NS No
OBS: Low sampling heads only were fitted.
If Yes:
8.2.31 The fittings used for switching between high and low sample heads / sensors appear in good operating condition S N/A
8.2.32 Hold spaces are provided with a gas sampling connection point D No
OBS: Gas sampling connection points were not installed for hold spaces.
COM: Immediate Cause/ Root Cause: The vessel was built in 2001 and there is no fixed gas sampling point connection was provided for the
vessel.
Corrective Action: Taking gas sampling is carried out safely under the safety procedure for gas sampling in the Companyâ s Safety
Management System. The hold spaces are always ventilated before open the body hatch of theirs for taking gas sampling.
Recurrence Prevention: The Company will consider to provide the vessel with fixed gas sampling points for hold spaces.
8.2.33 There are on board, instruments designed for the testing of toxic vapours S Yes
If Yes:
8.2.34 Number of portable instruments: 2
8.2.35 Number of fixed instruments: 0
8.2.36 All instruments designed for the testing of toxic vapours appear in good operating condition S Yes
8.2.37 Instruments designed for the testing of toxic vapours are suitable for the present voyage cargoes S Yes
8.2.38 All toxic gas detector tubes (when carried) are within their expiry date S Yes
8.2.39 When applicable, calibration checks of all instruments designed for the testing of toxic vapours are recorded S Yes
8.2.40 An instrument suitable for the testing of flammable vapours in an oxygen deficient atmosphere is available on
board
S Yes
If Yes:
8.2.41 All instruments for the testing of flammable vapours in an oxygen deficient atmosphere appear in good working
order
S Yes
8.2.42 Calibration checks of all instruments designed for the testing of flammable vapours in an oxygen deficient
atmosphere are recorded
S Yes
8.2.43 Decontamination showers and eyewashes are available on deck NS Yes
8.2.44 Decontamination showers and eyewashes will be able to operate in all ambient conditions S Yes
8.2.45 Decontamination showers and eyewashes appear in good operating condition S Yes
8.2.46 The locations of the decontamination showers and eyewashes are clearly marked R Yes
8.2.47 When appropriate, the manifold area and other key elevated working areas are protected by an appropriate handrail
of at least 1 m and including a midrail
D Yes
8.2.48 Oxygen detectors for personal use are carried on board R Yes
If Yes:
8.2.49 How many? 2
8.2.50 There are procedures covering the use of oxygen detectors for personal use R Yes
8.2.51 Gas detectors for personal use are carried on board R Yes
If Yes:
8.2.52 How many? 3
8.2.53 There are procedures covering the use of gas detection equipment for personal use R Yes
Page 45 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Remarks:
(No remarks)
Comments:
(none)
Page 46 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Page 47 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Ship: LADY LINN Ship IMO: 9241176 Report Nr.: 140832 Rev.: 9 (2019)
Inspector: BAE - STH KOREA Insp. Date : 15-07-2022 Insp./Ship Type: Gas/Gas Port: Yeosu, Korea
Chapter: 9: Firefighting
Section: 1: Firefighting Equipment
Questions Cat Answer
9.1.1 * The fire control plan(s) is permanently displayed OR a copy of the fire control plan(s) is supplied to all officers
S Yes
and one copy is available on board in an accessible position
9.1.2 * All fire control plans are up to date S Yes
9.1.3 * Fire control plan(s) is available in the language required by the Flag State, as well as in either English or French S Yes
9.1.4 * All fire control plans are clearly legible D Yes
9.1.5 * Fire control plan(s) is permanently stored in a weathertight enclosure outside the deckhouse and is prominently
S Yes
marked
9.1.6 * A copy of the fire control plan is located at the gangway while the vessel is berthed. D Yes
9.1.7 * The total cargo carrying capacity of the ship is 5000m3 OR LESS NS Yes
If Yes:
9.1.8 * There are at least four fireman's outfits on board S Yes
If No:
9.1.9 * There are at least five fireman's outfits on board S N/A
9.1.10 * All fireman's outfits are accessible, complete, ready for use, and in good condition S Yes
9.1.11 * Spare charges (air bottles) are available for the breathing apparatus S Yes
9.1.12 * Breathing apparatus air bottles are stamped to indicate they have been pressure tested within the previous five
S Yes
years
9.1.13 * When fitted, the breathing apparatus air cylinder compressor is available for use, and operating instructions are
S Yes
available for use
9.1.14 * When fitted with a breathing apparatus air cylinder compressor, the compressor appears to be in good order and
S Yes
there are maintenance records available
9.1.15 * There are sufficient Emergency Escape Breathing Devices (EEBD) in good condition, ready for use, and as
S Yes
indicated on the Fire Control Plan
9.1.16 * The main fire pump is in good order and available for use S Yes
9.1.17 * The ship is certified for Unattended Machinery Space Operation NS No
OBS: Non-UMS vessel.
If Yes:
9.1.18 * A remote start for the fire pump is located on the bridge, or the fire main is pressurized S N/A
9.1.19 * Emergency fire pump is in good order and available for use S Yes
9.1.20 * Starting instructions for the emergency fire pump are displayed at the starting location D Yes
9.1.21 * Fire/foam main is in good order and ready for use S Yes
9.1.22 * Fire/foam hydrants are in good order and ready for use S Yes
9.1.23 * Isolation valves in the fire / foam main are in good order and ready for use S Yes
9.1.24 * Fire hoses are in good order and ready for use S Yes
9.1.25 * Fire hoses of similar diameter have compatible couplings S Yes
9.1.26 * Fire nozzles are of a dual purpose type (i.e. jet / spray) incorporating a shutoff S Yes
Page 48 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
9.1.27 * Fire nozzles are in good order and ready for use S Yes
9.1.28 * International shore connection is in good order and ready for use S Yes
9.1.29 * Location of the international shore connection is clearly marked D Yes
9.1.30 * Fire stations are complete, in good condition and clearly marked S Yes
9.1.31 * Machinery space fixed fire fighting system appears in good condition S Yes
9.1.32 A Hyper-mist fire fighting system for the machinery space is fitted NS No
OBS: Hyper-mist fire fighting system was not fitted.
If Yes:
9.1.33 A system is in place to ensure a sufficient quantity of water is available for the system S N/A
9.1.34 * Fire extinguishers, as fitted, appear in good condition S Yes
9.1.35 * Servicing of fire extinguishers, fixed firefighting systems and CO2 systems are up to date S Yes
9.1.36 * Spare charges for fire extinguishers are available S Yes
9.1.37 * The machinery space fire alarm system appears in good condition S Yes
9.1.38 * The machinery space fire detection system (when fitted) appears in good condition S Yes
9.1.39 * The cargo compressor room fire alarm system (when fitted) appears in good condition S N/A
9.1.40 * The cargo compressor room fire detection system (when fitted) appears in good condition S N/A
9.1.41 * The accommodation fire alarm system (when fitted) appears in good condition S Yes
9.1.42 * The accommodation fire detection system (when fitted) appears in good condition S Yes
9.1.43 * Fire alarm and detection systems are tested in accordance with manufacturer's instructions S Yes
9.1.44 * A water spray system is installed for the cargo area NS Yes
If Yes:
9.1.45 * Water spray system protects all relevant areas and surfaces S Yes
9.1.46 * Water spray system appears in good condition S Yes
9.1.47 * Water spray nozzles do not appear to be blocked S Yes
9.1.48 * Water spray system activation points are clearly marked D Yes
9.1.49 * Water spray system test records are available S Yes
9.1.50 Date of last two tests: 29-06-2022
9.1.51 __________ 27-05-2022
9.1.52 * A dry powder system is installed for the cargo area NS Yes
If Yes:
9.1.53 * Dry powder hoses and nozzles appear in good condition S Yes
9.1.54 * Dry powder storage and activation system appears in good condition S Yes
9.1.55 * Nitrogen cylinders for dry powder system activation appear to be fully charged D Yes
9.1.56 * Operating instructions for the dry powder system are posted at all operating positions D Yes
9.1.57 A fixed foam firefighting system is installed NS No
OBS: Fixed foam fire fighting system was not installed.
If Yes:
9.1.58 A fixed foam firefighting system is installed for the cargo area NS N/A
9.1.59 A fixed foam firefighting system is installed for the machinery spaces NS N/A
9.1.60 * The foam storage tank and associated equipment appears in good condition S N/A
Page 49 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Page 50 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Chapter: 9: Firefighting
Section: 2: Crew Knowledge and Proficiency
Questions Cat Answer
9.2.1 * Officers are familiar with the operation of the machinery space fixed firefighting system S Yes
9.2.2 * Officers are familiar with the operation of the cargo area fixed fire fighting system(s) S Yes
9.2.3 * When fitted with a breathing apparatus air cylinder compressor for firefighting BA sets, personnel responsible for
filling breathing air cylinders are familiar with the use of the equipment, and ensuring proper air quality when using the S Yes
equipment
9.2.4 * Personnel are familiar with the use of the other firefighting equipment carried S Yes
9.2.5 Personnel are familiar with the steps to be taken to respond to a vent mast fire, including: - stopping the venting of
cargo/gas - injecting inert gas into the vent if possible - spraying the mast head with water
R Yes
Remarks:
(No remarks)
Comments:
(none)
Page 51 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Ship: LADY LINN Ship IMO: 9241176 Report Nr.: 140832 Rev.: 9 (2019)
Inspector: BAE - STH KOREA Insp. Date : 15-07-2022 Insp./Ship Type: Gas/Gas Port: Yeosu, Korea
Page 52 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
10.1.30 * There are at least four line throwing appliance projectiles and lines on board S Yes
10.1.31 * All projectiles (and any ignitors) are within their expiry date S Yes
10.1.32 * There are at least 12 parachute flares stowed on or near the navigating bridge S Yes
10.1.33 * Parachute flares are within their expiry date S Yes
10.1.34 * Emergency escape routes and exits, including those to lifesaving appliances, are clearly marked, unobstructed, and
S Yes
adequately illuminated
10.1.35 * A record of inspections and maintenance of each life-saving appliance is available S Yes
10.1.36 * A report of a monthly inspection of the life-saving appliances is recorded in the log-book (SOLAS III 20.6
S Yes
(weekly)
10.1.37 * A stretcher of suitable design is readily available on board and appears in good condition S Yes
10.1.38 * The actual number of personnel sailing on board is within the limits of the Safety Equipment Certificate
S Yes
(Attachment Form E)
10.1.39 There is a suitable ship-specific plan for the recovery of persons from the water S Yes
Remarks:
(No remarks)
Comments:
(none)
Page 53 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Page 54 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Ship: LADY LINN Ship IMO: 9241176 Report Nr.: 140832 Rev.: 9 (2019)
Inspector: BAE - STH KOREA Insp. Date : 15-07-2022 Insp./Ship Type: Gas/Gas Port: Yeosu, Korea
Page 55 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
11.1.26 * Suitable and permanent spill containment is fitted around all hydraulic deck machinery and in good condition R Yes
11.1.27 * The ship has in place a ship-specific Ballast Water Management Plan, approved by the Administration and/or
S Yes
Class
11.1.28 When required, ballast water treatment equipment is installed S Yes
11.1.29 If ballast water treatment equipment is installed, the equipment appears to be in working order S Yes
11.1.30 A Company manual contains a policy on energy conservation R Yes
11.1.31 The ship is fitted with an exhaust gas or waste heat boiler NS No
OBS: Exhaust gas boiler was not fitted.
11.1.32 Cargo cooling / heating procedures are available R N/A
11.1.33 The Company has procedures for monitoring the performance of main and auxiliary machinery R Yes
11.1.34 The Company provides energy conservation training to all crew R Yes
11.1.35 The company has procedures for operating machinery/equipment in a safe and efficient manner R Yes
Remarks:
(No remarks)
Comments:
(none)
Page 56 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Page 57 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Ship: LADY LINN Ship IMO: 9241176 Report Nr.: 140832 Rev.: 9 (2019)
Inspector: BAE - STH KOREA Insp. Date : 15-07-2022 Insp./Ship Type: Gas/Gas Port: Yeosu, Korea
Page 58 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Ship: LADY LINN Ship IMO: 9241176 Report Nr.: 140832 Rev.: 9 (2019)
Inspector: BAE - STH KOREA Insp. Date : 15-07-2022 Insp./Ship Type: Gas/Gas Port: Yeosu, Korea
Page 59 of 60
CDI-Marine Inspection Report 16-8-2022 06:07:02
Ship: LADY LINN Ship IMO: 9241176 Report Nr.: 140832 Rev.: 9 (2019)
Inspector: BAE - STH KOREA Insp. Date : 15-07-2022 Insp./Ship Type: Gas/Gas Port: Yeosu, Korea
Page 60 of 60