You are on page 1of 6

STR2601 Major Test 1 2023

UNIVERSITY OF SOUTH AFRICA


SCHOOL OF ENGINEERING
CONTINUOUS ASSESSMENT

TEST NO: MAJOR TEST 1

Semester Course

STR2601

STRUCTURAL STEEL DESIGN

Examiner: Mr. M Ngonyama Moderator: Mrs. M Mulaudzi


Marks: 45 External Moderator: Ms. Sole
Weight of Assessment: 35% Duration: 2 hours
Open Book Test
This test consists of 6 pages, 1 cover pages, 2 content pages and 3 appendix
pages.

YOUR SCRIPT MUST BE SAVED WITH STUDENT NO, SUBJECT CODE AND
UPLOADED ON ASSESSMENT 6 PLATFORM. EXAMPLE 72111985QAS401I
• Honesty Declaration must be completed
• The module is IRIS invigilated
Additional student instructions
1. Students must upload their answer scripts in a single PDF file (answer scripts must
not be password protected or uploaded as “read only” files)
2. NO emailed scripts will be accepted.
3. Students are advised to preview submissions (answer scripts) to ensure legibility
and that the correct answer script file has been uploaded.
4. Students are permitted to resubmit their answer scripts should their initial
submission be unsatisfactory.
5. Incorrect file format and uncollated answer scripts will not be considered.
6. Incorrect answer scripts and/or submissions made on unofficial examinations
platforms (including the invigilator cell phone application) will not be marked and no
opportunity will be granted for resubmission.
7. Mark awarded for incomplete submission will be the student’s final mark. No
opportunity for resubmission will be granted.
8. Mark awarded for illegible scanned submission will be the student’s final mark. No
opportunity for resubmission will be granted.
9. Submissions will only be accepted from registered student accounts.
10. Students who have not utilised invigilation or proctoring tools will be subjected to
disciplinary processes.
11. Students suspected of dishonest conduct during the examinations will be
subjected to disciplinary processes. UNISA has a zero tolerance for plagiarism and/or any
other forms of academic dishonesty.
12. Students are provided one hour to submit their answer scripts after the official
examination time. Submissions made after the official examination time will be rejected.
To proceed with the writing of the examination, click on the link below:
STR2601 Major Test 1 2023

Question 1
A Tapper flange channel C100 x 50 shown in Figure 1 is connected to a gusset plate
with a E70XX 8 mm weld. Calculate the design tensile resistance of the angle. Use
S355JR steel grade.

Note: Check all possible failure modes

Figure 1: Gusset Plate Connection

[16 Marks]

2
STR2601 Major Test 1 2023

Question 2

A T-section cut from 229 x 191 x 34 kg/m is made from 457 x 191 x 90 kg/m I-section,
used as a column is subjected to axial compression due to the position of the member
on the structure. If the column of 4500 mm length is fixed on one end and pinned on
the other end. Determine the compressive resistance of the section.

[29 Marks]

TOTAL MARKS [45]


©
UNISA 2022

3
STR2601 Major Test 1 2023

Figure 2: Southern Steel Construction Handbook

4
STR2601 Major Test 1 2023

Figure 3:Southern Steel Construction Handbook

5
STR2601 Major Test 1 2023

Figure 4:Southern Steel Construction Handbook

You might also like