You are on page 1of 5

Totally Integrated

Automation Portal

test / PLC_1 [CPU 1214C DC/DC/DC] / Program blocks


Main [OB1]
Main Properties
General
Name Main Number 1 Type OB Language LAD
Numbering Automatic
Information
Title "Main Program Sweep (Cy‐ Author Comment Family
cle)"
Version 0.1 User-defined ID

Main
Name Data type Default value Comment
Input
Initial_Call Bool Initial call of this OB
Remanence Bool =True, if remanent data are available
Temp
Constant

Network 1:

%M0.0 %M0.1 %M10.0


"ON" "OFF" "TG_ON"

%M10.0
"TG_ON"

Network 2:
Totally Integrated
Automation Portal

%M0.2
%M10.0 "CAR ENTRY_ %M1.0
"TG_ON" SENSOR" "TG_CONVEYOR"

%M1.0
"TG_CONVEYOR"

Network 3:

%M0.7
%M10.0 %M1.0 %Q0.2 %Q0.1 %Q0.3 %Q0.4 "CAR EXIT_ %Q0.0
"TG_ON" "TG_CONVEYOR" "WASH" "SOAP" "CLEAN" "DRYER" SENSOR" "CONVEYOR"

"T_1".Q "T_0".Q "T_2".Q "T_3".Q

Network 4:

%M0.3
%M10.0 "SOAP STAGE_ %M1.1
"TG_ON" SENSOR" "TG_SOAP"

%M1.1
"TG_SOAP"

Network 5:
Totally Integrated
Automation Portal

%M10.0 %M1.1 %Q0.1


"TG_ON" "TG_SOAP" "T_0".Q "SOAP"

%DB1
"T_0"
TON
Time
IN Q
T#10S PT ET T#0ms

Network 6:

%M0.4
%M10.0 "WASH STAGE_ %M1.2
"TG_ON" "T_0".Q SENSOR" "TG_WASH"

%M1.2
"TG_WASH"

Network 7:

%M10.0 %M1.2 %Q0.2


"TG_ON" "TG_WASH" "T_1".Q "WASH"

%DB2
"T_1"
TON
Time
IN Q
T#10S PT ET T#0ms
Totally Integrated
Automation Portal

Network 8:

%M0.5
%M10.0 "CLEAN STAGE- %M1.3
"TG_ON" "T_1".Q SENSOR" "TG_CLEAN"

%Q0.3
"CLEAN"

Network 9:

%M10.0 %M1.3 %Q0.3


"TG_ON" "TG_CLEAN" "T_2".Q "CLEAN"

%DB3
"T_2"
TON
Time
IN Q
T#10S PT ET T#0ms

Network 10:
Totally Integrated
Automation Portal

%M0.6
%M10.0 "DRYER TAGE_ %M1.4
"TG_ON" "T_2".Q SENSOR" "TG_DRYER"

%M1.4
"TG_DRYER"

Network 11:

%M10.0 %M1.4 %Q0.4


"TG_ON" "TG_DRYER" "T_3".Q "DRYER"

%DB4
"T_3"
TON
Time
IN Q
T#10S PT ET T#0ms

Network 12:

%M0.7
%M10.0 %M1.4 "CAR EXIT_ %Q0.5
"TG_ON" "TG_DRYER" SENSOR" "DONE"