You are on page 1of 3

1.

  What does PEC stand for? 
2.  What is the purpose of PEC? 
3.  What are six covers of article 110-Requirement for electrical installation. 
4.   Define “Equipment” based in the PEC. 
5.  What are the 8 considerations in evaluating equipment.  
6.   Why listed or labeled equipment shall be installed and used in accordance with any instructions 
included in the listing or labeling. 
7.  What do you mean by this statement in PEC "The voltage rating of electrical equipment shall not 
be less than the nominal voltage of a circuit to which it is connected"  
8.  What article number saying this statement "Where the conductor material is not specified, the 
material and the sizes given in this Code shall apply to copper conductors" 
9.  Conductor sizes are expressed in ____________ for stranded or in ___________ for solid. 
10. In your OWN WORDS explain "Insulation Integrity" 
11. What wiring method shall be used for two story building? 
12. Explain this statement "equipment intended to interrupt current at fault levels shall have an 
interrupting rating sufficient for the nominal circuit voltage and the current that is available at 
the line terminals of the equipment" 
13. What article stating "Listed products applied in accordance with their listing shall be considered 
to meet the requirements of this section" 
14. Why no conductors or equipment shall be located in damp or wet locations; where exposed to 
gases, fumes, vapors, liquids, or other agents that have a deteriorating effect on the conductors 
or equipment; or where exposed to excessive temperatures. Explain in Tagalog. 
15. What identification of equipment shall be protected against permanent damage from the 
weather during building construction. 
16. Give all the examples of Unused Openings. 
17. Explain in Tagalog “Where metallic plugs or plates are used with nonmetallic enclosures, they 
shall be recessed at least 6 mm from the outer surface of the enclosure” 
18. What do you mean by this statement "Conductors shall be racked to provide ready and safe 
access in underground and subsurface enclosures into which persons enter for installation and 
maintenance" 
19. What are the foreign materials that may damaged or contaminate internal parts of electrical 
equipment. 
20. What should not driven into holes in masonry, concrete, plaster, or similar materials shall not be 
used.  
21. Why Electrical equipment should be provided with ventilating openings  
22. Conductors of dissimilar metals shall not be intermixed in a terminal or splicing connector.  
23. Give examples of connection by means of pressure.  
24. Connection by means of wire-binding screws or studs and nuts that have upturned lugs or the 
equivalent shall be permitted for ___________ or smaller conductors.  
a.   5.5 mm2 (2.6 mm dia.) 
25. Explain this statement in tagalog "all splices and joints and the free ends of conductors shall be 
covered with an insulation equivalent to that of the conductors or with an insulating device 
identified for the purpose" 
26. What is the requirement of 1.10.2.2(a)(2) or 1.10.3.2(b)(1) about Guarding? 
27. Where should the ventilation must be provided wherever practicable? 
28. What do you mean by this statement "if applicable, access openings for pers
onnel shall be 
arranged? Explain in Tagalog. 
29. Where is the good location of Access openings for personnel? 
30. What is the dimension of rectangular access openings? 
31. What are the considerations in Bending Space for Conductors? 
32. Where electric equipment with live parts that is likely to require examination
, adjustment, 
servicing, or maintenance while energized is installed in a manhole, vault, or oth
er enclosure 
designed for personnel access, the work space and associated requirements in 1.
10.2.1. True or 
False? 
33. What is "A clear work space"?  
34. What shall be shall be installed within sight of each transformer or motor loc
ation for 
disconnecting the transformer or motor? 
35. What will you do in the Energized Parts? 
36. What shall be shall be permitted to be insulated or bare?  
37. What will you do all all non–current-carrying metal parts of electric equipme
nt and all metal 
raceways and cable sheaths? 
38. What shall be hall be installed in metal conduit or other metal raceway, Type 
MC cable, or other 
approved multiconductor cable? 
39. What shall be hall be supported in a manner designed to prevent physical da
mage to the braid 
or sheath? 
40. What is the elevation of unguarded live parts having a voltage rating of 7,501
–35,000 V? 
41. What shall not be located in the vicinity of the service equipment, metal-
enclosed power 
switchgear, or industrial control assemblies.  
42. What is the importance of Illumination? 
43. Explain the different conditions in minimum depth of clear Working space at 
electrical 
equipment.  
44. What should be provided to give safe access to the working space around ele
ctric equipment 
installed on platforms, balconies, or mezzanine floors or in attic or roof rooms or 
spaces.  
45. Explain "Enclosed Equipment Accessible to Unqualified Person" 
46. Discuss this statement " In Places Accessible to Unqualified Persons. Outdoor 
electrical 
installations that are open to unqualified persons shall comply with Parts 2.25.1, 
2.25.2, and 
2.25.3." 
47. Justify this statement "Entrances to rooms and other guarded locations that 
contain exposed 
live parts shall be marked with conspicuous warning signs forbidding unqualified 
persons to 
enter" 
48. Explain why live parts of electrical equipment operating at 50 volts or more s
hall be guarded 
against accidental contact by approved enclosures? 
49. Suspended ceilings with removable panels shall be permitted within the ___
___ zone.  