You are on page 1of 1

1 2 3 4 5 6

You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com)
CAPACITY :- Raw Natural Gas 6000 kg/hr
A A
CONTROL
PAN EL
PG04 PT01 PT

GAS ANALYZEER
SV
PG02 SV SV PG03
PSV02
Product Natural Gas
BPC01 CV09
CV06 CV07

MBV07
B SV
B
FCV01
S U R GE

NRV02
CV08 T A NK

Natural Flowtrans
GAS ANALYZEER NRV01

meter

MBV08
MBV06
Raw
Natural Gas O2A

TO
CONTROL PANEL
SV SV

FCV02
PG06
CV03 CV04
SV SV

INSTRUMENT HEADER
P RE
F I L TER
CV01 CV02
MBV05
MBV02
A CT I V. MBV03 P R E S S U R E SW I NG P R E S S U R E SW I NG
C A R BON A D S O R P TI ON A D S O R P TI ON
ADV01 CV05
F I L TER T O W E R-1 T O W E R-2
C MBV04
C
MBV10
TO INST. HEADER OPTIONAL INSTRUMENTS
AIR
CAPACITY :- Raw Natural Gas 6000kg/hr
BOSCO INDIA
P.O. No. :- SAMPLE. P.O. DATE : SAMPLE
CLIENT :- OFFER DRAWING
D D
TITLE :- P&I DIAGRAM FOR N2 PLANT
D S N DNV JOB NO. :- 1129
SCALE :- N.T.S.
D R N BAZ DRG.NO. :- AP/KIT/1129/P&I/001
C H D DNV REV.NO 00 01 02 03 SHEET NO.
DATE 02 May 2013 DATE 02-05-12 1 OF 1
NOTE :- ALL DIMENSIONS ARE IN MM. UNLESS OTHERWISE SPECIFIED.
1 2 3 4 5 6